The recommended operating voltage range for the 74AHCT1G07GV,125 is 4.5V to 5.5V, with a typical voltage of 5V.
To ensure proper power and decoupling, connect the VCC pin to a 5V power supply, and add a 0.1uF ceramic capacitor between VCC and GND as close to the device as possible.
The maximum frequency of operation for the 74AHCT1G07GV,125 is 100 MHz, but this can vary depending on the specific application and operating conditions.
During power-up and power-down, ensure that all input pins are held at a valid logic level (either high or low) to prevent unwanted switching. Output pins should be isolated or terminated to prevent back-powering the device.
The 74AHCT1G07GV,125 has an ESD protection rating of 2kV according to the Human Body Model (HBM) and 200V according to the Machine Model (MM).