The recommended operating voltage range for the 74ACT11074DBR is 4.5V to 5.5V, although it can operate down to 3.5V with reduced performance.
It is recommended to power up the VCC pin before the input signals, and power down the VCC pin after the input signals have been removed. This helps prevent unwanted output states during power-up and power-down.
The maximum frequency of operation for the 74ACT11074DBR is typically around 100 MHz, although this can vary depending on the specific application and operating conditions.
The 74ACT11074DBR requires proper termination to prevent signal reflections. This can be achieved by using a series terminator at the end of the transmission line, or by using a parallel terminator at the receiver end.
The maximum output current that the 74ACT11074DBR can sink or source is typically around 24 mA, although this can vary depending on the specific application and operating conditions.