Wurth Elektronik provides a recommended PCB layout and land pattern in their application notes and layout recommendations documents, which can be found on their website. It's essential to follow these guidelines to ensure optimal performance and minimize signal integrity issues.
The 687710200002 component has a maximum operating temperature of 125°C. To ensure proper thermal management, it's recommended to provide a thermal pad on the PCB, use thermal vias, and consider heat sinks or thermal interface materials if necessary. Additionally, ensure good airflow around the component and avoid blocking air vents or heat sinks.
Wurth Elektronik recommends following the IPC-J-STD-020D standard for soldering and rework conditions. The component is compatible with lead-free soldering processes, and the recommended peak reflow temperature is 260°C. It's essential to follow these guidelines to avoid damaging the component during assembly or rework.
To ensure EMC and reduce EMI, it's recommended to follow proper PCB design and layout practices, such as using ground planes, shielding, and filtering. Additionally, consider using EMI-absorbing materials and following Wurth Elektronik's application notes on EMC and EMI reduction.
The 687710200002 component has an MSL rating of 3, which means it can be exposed to a maximum of 168 hours at 30°C and 60% relative humidity before assembly. If the component is stored for an extended period, it may require baking according to the IPC/JEDEC J-STD-033C standard to prevent moisture-related issues.