The recommended operating temperature range for the 3650HG is -40°C to 85°C, although it can tolerate storage temperatures from -55°C to 150°C.
To ensure proper operation, power the 3650HG in the following sequence: VCC, then VDD, and finally the input signals. Power down in the reverse order.
The 3650HG can tolerate input voltages up to 5.5V, but it's recommended to keep input voltages within the specified operating range (VCC or VDD) to ensure reliable operation.
To prevent electrostatic discharge (ESD) damage, use ESD protection devices, such as TVS diodes or ESD arrays, on the input lines. Follow proper handling and storage procedures to minimize ESD exposure.
To minimize noise and ensure signal integrity, use a solid ground plane, keep input and output traces short and separate, and avoid running signals near the device's power pins.