Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    XPS PREVENTA Search Results

    XPS PREVENTA Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    AM1-DP200

    Abstract: XPS-ot XPS-AS preventa safety GNKL AM1DP200 XPS-AT XPS-ASf xps-ecp Preventa xps-al
    Text: Components for safety applications Preventa safety modules Dimensions, mounting XPS-AL, XPS-AX AM1-DP200 rail mounting 78 78 1 120 22,5 78 78 XPS-AT, XPS-FB, XPS-AM, XPS-AMF, XPS-AP, XPS-APF, XPS-ECM, XPS-ECP, XPS-NS, XPS-VN AM1-DP200 rail mounting 120 90


    Original
    PDF AM1-DP200 M1-DP200 XPS-ot XPS-AS preventa safety GNKL AM1DP200 XPS-AT XPS-ASf xps-ecp Preventa xps-al

    XPS-AF

    Abstract: XPSAF5130 XPS-AS XPS-AS5140 XPS-AF5130 XPS-AF safety XPS-AS3740 XPS-AS3440 xpsas3740 XPS-AS5140 cross reference
    Text: Product Substitution Details - Safety Modules XPS-AS Replaced by XPS-AF Differentiation n n n n n XPS-AF has one extra N/O safety output XPS-AF has choice of removable plug terminals XPS-AF has 22.5mm width XPS-AS has larger range of voltage selection XPS-AS can be be used for Type III A two-hand


    Original
    PDF 24VAC/DC XPS-AS5140 XPS-AF5130 48VAC/DC XPS-AS5340 120VAC XPS-AS3440 230VAC XPS-AS3740 XPS-AF XPSAF5130 XPS-AS XPS-AS5140 XPS-AF5130 XPS-AF safety XPS-AS3740 XPS-AS3440 xpsas3740 XPS-AS5140 cross reference

    XPS-BC1110

    Abstract: XPSBC1110 XPSBF1132 xps-bc XPS-BF1132 XPSBC3110 XPSBC3710 XPS-BC3410 XPS-BC3110 XPSBC3410
    Text: Product Substitution Details - Safety Modules XPS-BC Replaced by XPS-BF Differentiation n n n n XPS-BF has 2 solid state outputs for PLC signalling XPS-BF has choice of removable plug terminals XPS-BC has 1 N/C additional output XPS-BC has larger range of voltage supply selection


    Original
    PDF EN574) 24VDC XPS-BC1110 XPS-BF1132 24VAC XPS-BC3110 120VAC XPS-BC3410 230VAC XPS-BC1110 XPSBC1110 XPSBF1132 xps-bc XPS-BF1132 XPSBC3110 XPSBC3710 XPS-BC3410 XPS-BC3110 XPSBC3410

    XPS-AM5140

    Abstract: XPS-AK xps* preventa XPS-AM3440 XPSAM5140 XPS-AK311144 xpsak311144 XPS-AM3740 XPSAK351144 XPS-AM5340
    Text: Product Substitution Details - Safety Modules XPS-AM Replaced by XPS-AK Differentiation n n n n XPS-AK has 4 solid state output for PLC signalling XPS-AK has choice of removable plug terminals XPS-AK has 45mm width XPS-AM can be be used for Type III A two-hand


    Original
    PDF 24VDC 24VDC( 24VAC/DC XPS-AM5140 XPS-AK311144 48VAC/DC XPS-AM5340 120VAC XPS-AM5140 XPS-AK xps* preventa XPS-AM3440 XPSAM5140 XPS-AK311144 xpsak311144 XPS-AM3740 XPSAK351144 XPS-AM5340

    XPS-AS5140

    Abstract: xps-ak XPS-AS XPS-AS3740 XPS-AK371144 XPS-AS3440 XPSAK371144 xpsak311144 XPS-AK311144 xpsAK
    Text: Product Substitution Details - Safety Modules XPS-AS Replaced by XPS-AK Differentiation n n n n n XPS-AK has 1 extra N/O safety output XPS-AK has 1 extra additional N/C output XPS-AK has 4 solid state output for PLC signalling XPS-AK has choice of removable plug terminals


    Original
    PDF 24VDC 24VDC( S31XPS-AS 24VAC/DC XPS-AS5140 XPS-AK311144 48VAC/DC XPS-AS5340 XPS-AS5140 xps-ak XPS-AS XPS-AS3740 XPS-AK371144 XPS-AS3440 XPSAK371144 xpsak311144 XPS-AK311144 xpsAK

    xps-ak

    Abstract: XPS-ASF5142 XPS-ASf xpsak311144 XPSAK371144 XPS-AK311144 xpsAK XPSAK351144 xpsasf5142 XPS-AK371144
    Text: Product Substitution Details - Safety Modules XPS-ASF Replaced by XPS-AK Differentiation n n n n n XPS-AK has one extra N/O safety output XPS-AK has one extra additional N/C output XPS-AK has 2 extra solid state output for PLC signalling XPS-AK has choice of removable plug terminals


    Original
    PDF 24VDC 24VDC( S21/S31 24VAC/DC XPS-ASF5142 XPS-AK311144 48VAC/DC XPS-ASF5342 120VAC xps-ak XPS-ASF5142 XPS-ASf xpsak311144 XPSAK371144 XPS-AK311144 xpsAK XPSAK351144 xpsasf5142 XPS-AK371144

    AV11113P

    Abstract: xpsav11113 XPS-ATE3410 ATE3710 xps* preventa xpsate5110p en iso 13850 XPSAV11113P variable speed drive plc wiring diagram for synchronisation
    Text: Operating principle, characteristics Safety automation system solutions Preventa safety modules types XPS AV, XPS ATE For Emergency stop and switch monitoring Operating principle Safety modules XPS AV and XPS ATE are used for monitoring Emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1 and also meet


    Original
    PDF 1088/ISO 38783-EN AV11113P xpsav11113 XPS-ATE3410 ATE3710 xps* preventa xpsate5110p en iso 13850 XPSAV11113P variable speed drive plc wiring diagram for synchronisation

    XPSAC5121

    Abstract: XPS-AC5121 XPS-AC XPS-AX5120 XPSAC3721 XPS-AC3721 XPSAX5120 XPSAC3421 Preventa xps-ac XPS-AX
    Text: Product Substitution Details - Safety Modules XPS-AX Replaced by XPS-AC Differentiation n n n n XPS-AC has a solid state output for PLC signalling XPS-AX has one additional N/C output XPS-AC has choice of removable plug terminals XPS-AC has larger range of supply voltage selection


    Original
    PDF 24VDC 24VAC/DC XPS-AX5120 XPS-AC5121 48VAC XPS-AC1321 120VAC XPS-AC3421 230VAC XPSAC5121 XPS-AC5121 XPS-AC XPS-AX5120 XPSAC3721 XPS-AC3721 XPSAX5120 XPSAC3421 Preventa xps-ac XPS-AX

    XPS-AP5140

    Abstract: XPSAp3440 XPSAR311144 preventa safety xps* preventa xps-ar xps-ar311144 S11-S52 XPS-AP3740 XPSAR371144
    Text: Product Substitution Details - Safety Modules XPS-AP Replaced by XPS-AR Differentiation n n n n n XPS-AR has one extra N/O safety output XPS-AR has one extra additional N/C output XPS-AR has 4 solid state output for PLC signalling XPS-AR has choice of removable plug terminals


    Original
    PDF 24VDC 24VDC( 24VAC/DC XPS-AP5140 XPS-AR311144 48VAC/DC XPS-AP5340 120VAC XPS-AP5140 XPSAp3440 XPSAR311144 preventa safety xps* preventa xps-ar xps-ar311144 S11-S52 XPS-AP3740 XPSAR371144

    XPSAR311144

    Abstract: XPSAR371144 XPS-AR351144 XPS-APF5142 XPS-AR311144 XPS-APF3742 XPS-AR371144 XPSAR351144 preventa safety XPS-APF3442
    Text: Product Substitution Details - Safety Modules XPS-APF Replaced by XPS-AR Differentiation n n n n n XPS-AR has 2 extra solid state outputs for PLC signalling XPS-AR has choice of removable plug terminals XPS-AR has 1 extra N/O satety outputs XPS-AR cannot monitor safety mats or edges


    Original
    PDF 24VDC S41S42 24VDC( S11S12 24VAC/DC XPS-APF5142 XPS-AR311144 48VAC/DC XPS-APF5342 120VAC XPSAR311144 XPSAR371144 XPS-AR351144 XPS-APF5142 XPS-AR311144 XPS-APF3742 XPS-AR371144 XPSAR351144 preventa safety XPS-APF3442

    xpsak311144

    Abstract: XPS-AK311144 XPSAK371144 XPS-AK371144 XPS-AK XPSAK351144 XPS-AK351144 XPS-AK-351144 preventa safety b1s21
    Text: Product Substitution Details - Safety Modules XPS-AMF Replaced by XPS-AK Differentiation n XPS-AK has 2 extra solid state output for PLC signalling n XPS-AK has choice of removable plug terminals n XPS-AMF can be be used for Type III A two-hand control monitoring


    Original
    PDF 24VDC 24VDC( 24VAC/DC XPS-AMF5142 XPS-AK311144 48VAC/DC XPS-AMF5342 120VAC XPS-AMF3442 xpsak311144 XPS-AK311144 XPSAK371144 XPS-AK371144 XPS-AK XPSAK351144 XPS-AK351144 XPS-AK-351144 preventa safety b1s21

    bc 574

    Abstract: BA3720 limit switch VDE 0660 XPS-BA5120 XPSBF1132 XPS-BC1110 13851 XPS-BF1132 BF1132 T11-T12
    Text: Operating principle Safety automation system solutions Preventa safety modules types XPS BA, XPS BC, XPS BF For electrical monitoring of two-hand control stations Operating principle Two-hand control stations are designed to provide protection against hand injury.


    Original
    PDF 574/ISO 38790-EN Ver11 bc 574 BA3720 limit switch VDE 0660 XPS-BA5120 XPSBF1132 XPS-BC1110 13851 XPS-BF1132 BF1132 T11-T12

    XPSAL5110

    Abstract: XPS-AC5121 XPSAC5121 XPS-AC XPS-AL XPS-AL5110 XPSAC3721 xpsal3710 XPSAC3421 XPS-AC3721
    Text: Product Substitution Details - Safety Modules XPS-AL Replaced by XPS-AC Differentiation n XPS-AC has one extra N/O safety output n XPS-AC has a solid state output for PLC signalling n XPS-AC has choice of removable plug terminals Schematic Comparison Monitoring of E-stop with 2N/C contacts


    Original
    PDF 24VDC 24VDCK1 24VAC/DC XPS-AL5110 XPS-AC5121 48VAC XPS-AC1321 120VAC XPS-AL3410 XPSAL5110 XPS-AC5121 XPSAC5121 XPS-AC XPS-AL XPS-AL5110 XPSAC3721 xpsal3710 XPSAC3421 XPS-AC3721

    XPS ar

    Abstract: AR351144P iso 14119 diagnost XPSAR371144 XPSar311144p xps-ar311144 XPSAR311144 en iso 13850 DC-13 emergency leds
    Text: Safety automation system solutions Operating principle, characteristics Preventa safety modules type XPS AR For Emergency stop, switch or safety light curtain monitoring Operating principle Safety modules XPS AR meet the requirements of category 4 of the standard


    Original
    PDF 954-1/EN/ISO 1088/ISO category34 S33-S34 Y31/Y32 Y31/Y35 Y31/Y64 Y31/Y74 XPS ar AR351144P iso 14119 diagnost XPSAR371144 XPSar311144p xps-ar311144 XPSAR311144 en iso 13850 DC-13 emergency leds

    xps-ecp

    Abstract: XPS-ECP5131 XPS-ECM5131 preventa xps IEC 947-5-1 VDE 0660 preventa safety XPS-ECM3431 IEC 947-5-1 VDE 0660 LIMIT SWITCH IEC-947-5-1 AC15 B300 B300
    Text: Components for safety applications Preventa safety modules for increasing the number of safety contacts Operating principle, characteristics Operating principle 1 XPS-ECi safety modules, for increasing the number of safety contacts, are available as attachments for Preventa XPS


    Original
    PDF U1-13 U1-23. xps-ecp XPS-ECP5131 XPS-ECM5131 preventa xps IEC 947-5-1 VDE 0660 preventa safety XPS-ECM3431 IEC 947-5-1 VDE 0660 LIMIT SWITCH IEC-947-5-1 AC15 B300 B300

    PLC tsx SCY 21601

    Abstract: CUSB485 8RPS24100 ABL8RPS24100 CANCA50 MC16ZC CANCA100 R30 1130 tsx micro ATV71
    Text: Safety automation system solutions Presentation Preventa configurable safety controllers type XPS MC Presentation 105739 Configurable safety controllers XPS MCppZp are designed to provide a solution for safety applications requiring conformity to category 4 of standard EN 954-1/EN/


    Original
    PDF 954-1/EN/ MC16ZC MC16ZP MC32Z MC32ZC CA100 CUSB485 CA400 8RPS24100 CUSB485 PLC tsx SCY 21601 8RPS24100 ABL8RPS24100 CANCA50 MC16ZC CANCA100 R30 1130 tsx micro ATV71

    star delta wiring diagram motor start y

    Abstract: wiring diagram STAR DELTA motor starter wiring diagram, variable speed drives XPSVNE1142P wiring diagram motor start y XPSVNE3742P star delta starter diagram xps ak VNE1142P star delta connection LOGIC wiring circuit diagram
    Text: Operating principle Safety automation system solutions Preventa safety modules type XPS VNE For zero speed detection Operating principle Preventa safety modules XPS VNE for zero speed detection are used to detect the stop condition of electric motors. Their most common applications include: providing


    Original
    PDF Y33/Y43 38777-EN/2 38777-EN 38777-EN/3 38730-EN/2 star delta wiring diagram motor start y wiring diagram STAR DELTA motor starter wiring diagram, variable speed drives XPSVNE1142P wiring diagram motor start y XPSVNE3742P star delta starter diagram xps ak VNE1142P star delta connection LOGIC wiring circuit diagram

    telemecanique XCS-E

    Abstract: Telemecanique XPS Preventa xps-ac XPSAT5110 XPSAF5130 xpsav11113 XPS-AT3410 telemecanique xps-ak XPS-AC XPSAC5121P
    Text: Machine Safeguarding Products PREVENTA XPS Safety Relays Supplement Catalog 03 File 9007 CONTENTS Description Page Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10 General Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-12


    Original
    PDF 1-888-SquareD 9007CT0203 telemecanique XCS-E Telemecanique XPS Preventa xps-ac XPSAT5110 XPSAF5130 xpsav11113 XPS-AT3410 telemecanique xps-ak XPS-AC XPSAC5121P

    Untitled

    Abstract: No abstract text available
    Text: Product data sheet Characteristics XPSMC32ZC safety controller XPS-MC - 24 V DC - 32 input 48 LEDs signalling Commercial Status Commercialised Range of product Preventa Safety automation Product or component type Configurable safety controller Safety module name


    Original
    PDF XPSMC32ZC 954-1/EN/ 1760-1/ISO 574/ISO 954-1/EN/ISO

    Untitled

    Abstract: No abstract text available
    Text: Product data sheet Characteristics XPSMC16ZP safety controller XPS-MC - 24 V DC - 16 input 32 LEDs signalling Commercial Status Commercialised Range of product Preventa Safety automation Product or component type Configurable safety controller Safety module name


    Original
    PDF XPSMC16ZP 954-1/EN/ 1760-1/ISO 574/ISO 954-1/EN/ISO

    Untitled

    Abstract: No abstract text available
    Text: Product data sheet Characteristics XPSMC32Z safety controller XPS-MC - 24 V DC - 32 input 46 LEDs signalling Commercial Status Commercialised Range of product Preventa Safety automation Product or component type Configurable safety controller Safety module name


    Original
    PDF XPSMC32Z 954-1/EN/ 1760-1/ISO 574/ISO 954-1/EN/ISO

    XPS-AS5140

    Abstract: XPS-AS XPS-AM5140 XPS-AP5140 XPS-AM3440 XPSAp3440 XPS-Am S34 ST XPS-AS3740 S12-S34
    Text: Components for safety applications Preventa safety modules for emergency stop, limit switch and two-hand control monitoring Operating principle, characteristics Operating principle see page 1/12 1 Characteristics Type XPS-AS Product designed for use in safety


    Original
    PDF

    XPS-ASf

    Abstract: XPS-ASF5142 XPS-AS XPS-ASF3442 XPS-Apf xpsasf5142 XPS-ASF3742 Y33-Y34 xps-bc S41-S42
    Text: Components for safety applications Preventa safety modules for emergency stop, limit switch, two-hand control, safety mat and edge monitoring Operating principle, characteristics Operating principle see page 1/12 1 Characteristics Type XPS-ASF Product designed for use in safety


    Original
    PDF S11-S12, S21-S22 S11-B1 S21-S22 S11-S12) S33-S34 S21-S22) Y33/43 XPS-ASf XPS-ASF5142 XPS-AS XPS-ASF3442 XPS-Apf xpsasf5142 XPS-ASF3742 Y33-Y34 xps-bc S41-S42

    EN1050

    Abstract: IEC 947-5-1 VDE 0660 LIMIT SWITCH XPS-FB5111 xps* preventa xps-fb XPSFB3711 Electronic fuse linked state machines electromagnetic lock Y4 S4
    Text: Components for safety applications Preventa safety modules for electrical monitoring of limit switches combined in pairs Operating principle Operating principle 1 Preventa safety module XPS-FB meets the safety requirements for monitoring the operation of 2 limit switches used on


    Original
    PDF