Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    X-RAY THICKNESS Search Results

    X-RAY THICKNESS Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    923-2M1C-70H Amphenol Communications Solutions XCede HD, Backplane Connectors, Vertical Header, 2-pair, 6-column, Right End Wall, Thick Sidewall. Visit Amphenol Communications Solutions
    923-211G-70H Amphenol Communications Solutions XCede HD, Backplane Connectors, Vertical Header, 2-pair, 10-column, Double End Wall, Thick Sidewall. Visit Amphenol Communications Solutions
    923-311J-70H Amphenol Communications Solutions XCede HD, Backplane Connectors, Vertical Header, 3-pair, 4-column, Double End Wall, Thick Sidewall. Visit Amphenol Communications Solutions
    923-3Y1C-70H Amphenol Communications Solutions XCede HD, Backplane Connectors, Vertical Header, 3-pair, 6-column, Right Polarized Guide, Thick Sidewall. Visit Amphenol Communications Solutions
    9234M1J70H Amphenol Communications Solutions XCede HD, Backplane Connectors, Vertical Header, 4-pair, 4-column, Right End Wall, Thick Sidewall. Visit Amphenol Communications Solutions

    X-RAY THICKNESS Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    L9191

    Abstract: L9181 L9181-02 HAMAMATSU L9191 X-RAY INSPECTION AC Photonics C7336 C7716 C7876-10 l919
    Text: X-RAY I.I. CAMERA UNIT SERIES X-RAY C7336-50/-51, C7876/-10, C7716/-10 IMAGING X-ray Image Intensifier X-ray I.I. + CCD Camera High-quality X-ray images. Both low energy and high magnification are available. ▲Flower (C7876, X-ray tube voltage: 10 kV) ▲BGA


    Original
    PDF C7336-50/-51, C7876/-10, C7716/-10 C7876, C7716, C7876/-10) C7336-50/-51 C7716/-10) LC7336-50/-51, L9191 L9181 L9181-02 HAMAMATSU L9191 X-RAY INSPECTION AC Photonics C7336 C7716 C7876-10 l919

    Untitled

    Abstract: No abstract text available
    Text: X-RAY I.I. CAMERA UNIT C7716, C7716-10 NEW 3”/1.8” Dual Mode X-ray Image Intensifier X-Ray I. I. Efficiently Coupled to CCD Camera Captures sharp, clear X-ray images even from light element materials ! The C7716 series X-ray image intensifier (I. I.) camera


    Original
    PDF C7716, C7716-10 C7716 SE-171-41 1043E04

    VICTOREEN model 500

    Abstract: intensifier phosphor p20 VICTOREEN V3732P image intensifier -X-ray image intensifiers cesium iodide iodide V3733P
    Text: X-RAY IMAGE INTENSIFIERS High DQE • Excellent Image Quality • High Contrast An X-ray image intensifier is a large image tube that converts a low intensity X-ray image into a visible image. It is used for medical X-ray TV systems, X-ray nondestructive inspection systems,


    Original
    PDF S-164 1004E03 VICTOREEN model 500 intensifier phosphor p20 VICTOREEN V3732P image intensifier -X-ray image intensifiers cesium iodide iodide V3733P

    x-ray tube

    Abstract: TLSOB0102EA IEC61326 L10321 xray microfocus x-ray X-RAY INSPECTION x-ray tube datasheet C7716 C7716-10
    Text: 100 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L10321 TLSOF0185 FEATURES APPLICATIONS ●Wide X-ray Beam Angle: 118 ° ●Short FOD Focus to Object Distance : 7.3 mm ●Non-destructive Inspection ●X-ray CT ●In-line X-ray Inspection ●Focal Spot Size: 5 µm (at 4 W)


    Original
    PDF L10321 TLSOF0185 SE-171-41 TLSO1058E03 x-ray tube TLSOB0102EA IEC61326 L10321 xray microfocus x-ray X-RAY INSPECTION x-ray tube datasheet C7716 C7716-10

    x-ray tube

    Abstract: intensifier microfocus x-ray C7716 C7716-10 x-ray view box CCD MARKING Image intensifier tube
    Text: X-RAY I.I. CAMERA UNIT C7716, C7716-10 NEW 3-inch/1.8-inch Dual Mode X-ray Image Intensifier X-Ray I. I. Efficiently Coupled to CCD Camera Captures sharp, clear X-ray images even from light element materials ! The C7716 series X-ray image intensifier (I. I.) camera


    Original
    PDF C7716, C7716-10 C7716 SE-171-41 1043E05 x-ray tube intensifier microfocus x-ray C7716-10 x-ray view box CCD MARKING Image intensifier tube

    Untitled

    Abstract: No abstract text available
    Text: 100 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L10321 TLSOF0185 FEATURES APPLICATIONS ●Wide X-ray Beam Angle: 118 ° ●Short FOD Focus to Object Distance : 7.3 mm ●Non-destructive Inspection ●X-ray CT ●In-line X-ray Inspection ●Focal Spot Size: 5 µm (at 4 W)


    Original
    PDF L10321 TLSOF0185 SE-171-41 TXPR1013E01

    x-ray

    Abstract: 3 ccd progressive scan C7336-03 AC Photonics interline sharp CCD Camera C7716 "frame grabber"
    Text: X-RAY I.I. DIGITAL CAMERA X-RAY UNIT SERIES IMAGING C7336-03/-04 OVERVIEW The C7336-03/04 consist of a high resolution, high contrast 4-inch X-ray image intensifier X-ray I.I. and a 1.45 megapixel digital CCD camera. The X-ray I.I. used has a fixed field-of-view of 100


    Original
    PDF C7336-03/-04 C7336-03/04 SE-171-41 1053E02 x-ray 3 ccd progressive scan C7336-03 AC Photonics interline sharp CCD Camera C7716 "frame grabber"

    Untitled

    Abstract: No abstract text available
    Text: X-RAY I.I. DIGITAL CAMERA X-RAY UNIT SERIES IMAGING C7336-05/-52 •BGA ●Digital type C7336-05 Clear, Sharp Image X-ray tube voltage: 80 kV ●Analog type OVERVIEW The C7336 series consist of a high resolution, high contrast 4inch X-ray image intensifier (X-ray I.I.) and a 2.8 megapixel


    Original
    PDF C7336-05/-52 C7336-05) C7336 IEEE1394b. SE-164 TXPR1017E04 B1201

    car front camera

    Abstract: x-ray x-ray tube 20kv solid relay x-ray tube datasheet C7077 C7716 C7716-10 C7876-10 X-RAY thickness
    Text: X-RAY I.I. CAMERA UNIT C7876, C7876-10 NEW 4” X-ray Image Intensifier with Beryllium Window Efficiently Coupled to CCD Camera Captures low-energy X-ray images in real time! The C7876 series X-ray image intensifier X-ray I. I. camera units are ideal for non-destructive inspection of light-element


    Original
    PDF C7876, C7876-10 C7876 SE-171-41 1047E01 car front camera x-ray x-ray tube 20kv solid relay x-ray tube datasheet C7077 C7716 C7716-10 C7876-10 X-RAY thickness

    Untitled

    Abstract: No abstract text available
    Text: High Resolution X-ray Imaging System High Resolution X-ray Imaging System R ▲ M11427-42 Camera: ORCA-Flash4.0V2 The high resolution X-ray imaging system is designed for the application of X-ray beam alignment. Adopting unique mechanism, it enables to combine


    Original
    PDF M11427-42 B1201 SCAS0011E13 OCT/2014

    Untitled

    Abstract: No abstract text available
    Text: High Resolution X-ray Imaging System High Resolution X-ray Imaging System R ▲ M11427-42 Camera: ORCA-Flash4.0 The high resolution X-ray imaging system is designed for the application of X-ray beam alignment. Adopting unique mechanism, it enables to combine


    Original
    PDF M11427-42 SE-164 SCAS0011E11 DEC/2012

    Untitled

    Abstract: No abstract text available
    Text: 110 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L9631 Optimum for In-line X-ray Inspection System FEATURES ●High Output: 800 µA 50 W It allows continuous maximum output. ●High Stability ●Serial Port Control (RS-232C) One package of a sealed type X-ray tube, a high-voltage power


    Original
    PDF L9631 RS-232C) SE-171-41 TXPR1014E01

    Untitled

    Abstract: No abstract text available
    Text: 130 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L9181-02 FEATURES ● Focal Spot Size: 5 µm at 4 W Sealed type X-ray tube with 5 µm focal spot allows clear X-ray images even at a high magnification. ●Easy Handling Fully operable from external PC. ●Serial Port Control (RS-232C)


    Original
    PDF L9181-02 RS-232C) SE-171-41 TXPR1015E01

    BICRON surveyor 2000

    Abstract: BICRON surveyor M BICRON 1M preset, horizontal microfocus x-ray L6731-01 VICTOREEN dispenser cathode ion chamber X-RAY INSPECTION
    Text: 80kV TYPE : L6731-01 / 130kV 8 µm MICROFOCUS X-RAY SOURCE TYPE : L6622-01 300 µm CONVENTIONAL X-RAY SOURCE X-RAY FOCAL SPOT D1 OBJECT D2 CLEAR IMAGE Target Voltage:45kV x10 Target Voltage:70kV ×100 INDISTINCT IMAGE Target Voltage:70kV ×6 In X-ray imaging, the magnification and resolution are


    Original
    PDF L6731-01 130kV L6622-01 SE-171-41 1026E02 BICRON surveyor 2000 BICRON surveyor M BICRON 1M preset, horizontal microfocus x-ray VICTOREEN dispenser cathode ion chamber X-RAY INSPECTION

    image sensor x-ray

    Abstract: x-ray tube csi fop SERVICE MANUAL tv sony scintillator H8480-03 x-ray sensor H8481-06 sony tv service manual H8480
    Text: X-CUBE NEW COMPACT X-RAY CCD CAMERAS H8480 Series SAMPLE X-RAY IMAGES Sample: Digital camera memory media X-ray tube voltage: 80 kV p X-ray tube current: 100 µA H8481 H8480 High Resolution Type Effective area: 25 mm Min. Resolution : 8 Lp/mm Effective area: 8.8 mm x 6.6 mm


    Original
    PDF H8480 H8481 H8480 H8481. SE-171-41 TMCP1029E02 image sensor x-ray x-ray tube csi fop SERVICE MANUAL tv sony scintillator H8480-03 x-ray sensor H8481-06 sony tv service manual

    L9421-02

    Abstract: L9421 x-ray tube datasheet sharp ccd x-ray C7716 C7716-10 C7876-10 H8480 H8953
    Text: 90 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L9421-02 FEATURES ● Focal Spot Size: 5 µm at 4 W The focal spot of 5 µm of the sealed type X-ray tube enables sharp and clear X-ray images even at a high magnification. ●Easy Handling Fully operable from an external PC.


    Original
    PDF L9421-02 RS-232C) SE-171-41 TLSO1055E03 L9421-02 L9421 x-ray tube datasheet sharp ccd x-ray C7716 C7716-10 C7876-10 H8480 H8953

    Untitled

    Abstract: No abstract text available
    Text: 90 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L9421-02 FEATURES ● Focal Spot Size: 5 µm at 4 W The focal spot of 5 µm of the sealed type X-ray tube enables sharp and clear X-ray images even at a high magnification. ●Easy Handling Fully operable from an external PC.


    Original
    PDF L9421-02 RS-232C) SE-171-41 TXPR1011E01

    HAMAMATSU L9181

    Abstract: L9181-02 intensifier x-ray tube L9181 X-RAY thickness IEC61326 L9181 x-ray x-ray tube datasheet C7716
    Text: 130 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L9181-02 FEATURES ●Focal Spot Size: 5 µm at 4 W Sealed type X-ray tube with 5 µm focal spot allows clear X-ray images even at a high magnification. ●Easy Handling Fully operable from external PC. ●Serial Port Control (RS-232C)


    Original
    PDF L9181-02 RS-232C) SE-171-41 TLSO1061E01 HAMAMATSU L9181 L9181-02 intensifier x-ray tube L9181 X-RAY thickness IEC61326 L9181 x-ray x-ray tube datasheet C7716

    Untitled

    Abstract: No abstract text available
    Text: IMAGE SENSOR CCD area image sensor S7361 Front-illuminated FFT-CCDs for X-ray imaging S7361 is a family of FFT-CCD image sensors specifically designed for X-ray imaging. FOS Fiber Optic plate with Scintillator that converts X-ray into visible-light is mounted on a CCD chip, which enables S7361 to do the X-ray imaging.


    Original
    PDF S7361 S7361 S7361, SE-171 KMPD1046E01

    LEMO

    Abstract: LEMO FGG.2B bio-chemical sensor x-ray cmos image sensor LEMO 5 pin out TX20A-36PH1-D2P1-D1E TX20A-36R-D2GF1 C7942CK-12 LEMO 7 pin ecg replacement guide
    Text: IMAGE SENSOR Flat panel sensor C7942CK-12 Acquire digital X-ray image in real time and 170 mm diagonal size Flat panel sensors C7942CK-12 is a digital X-ray image sensor newly developed as a key device for biochemical imaging, X-ray microscopy and other real-time X-ray imaging applications requiring high resolution and high image quality.


    Original
    PDF C7942CK-12 C7942CK-12 12-bit) SE-171 KACC1114E05 LEMO LEMO FGG.2B bio-chemical sensor x-ray cmos image sensor LEMO 5 pin out TX20A-36PH1-D2P1-D1E TX20A-36R-D2GF1 LEMO 7 pin ecg replacement guide

    s603

    Abstract: S604 Kvp 57 mosfet 20020 scintillator sensor x-ray 7361 ccd diode datasheet CCD FIBER OPTIC S599
    Text: IMAGE SENSOR CCD area image sensor S7361 Front-illuminated FFT-CCDs for X-ray imaging S7361 is a family of FFT-CCD image sensors specifically designed for X-ray imaging. FOS Fiber Optic plate with Scintillator that converts X-ray into visible-light is mounted on a CCD chip, which enables S7361 to do the X-ray imaging.


    Original
    PDF S7361 S7361 S7361, SE-171 KMPD1046E01 s603 S604 Kvp 57 mosfet 20020 scintillator sensor x-ray 7361 ccd diode datasheet CCD FIBER OPTIC S599

    Untitled

    Abstract: No abstract text available
    Text: 100 kV X-RAY MICROFOCUS X-RAY SOURCE SOURCE L10101 Short FOD: 6.8 mm TLSOF0185 FEATURES ●Short FOD Focus to Object Distance : 6.8 mm X-ray image with Higher Magnification ratio ●High Power: Maximum Output 20 W ●Focal Spot Size: 5 µm (at 4 W) The focal spot of 5 µm of the sealed type X-ray tube enables


    Original
    PDF L10101 TLSOF0185 SE-171-41 TXPR1012E01

    Kvp 57

    Abstract: No abstract text available
    Text: IMAGE SENSOR Flat panel sensor C7942CK-12 Acquire digital X-ray image in real time and 170 mm diagonal size Flat panel sensors C7942CK-12 is a digital X-ray image sensor newly developed as a key device for biochemical imaging, X-ray microscopy and other real-time X-ray imaging applications requiring high resolution and high image quality.


    Original
    PDF C7942CK-12 C7942CK-12 12-bit) SE-171 KACC1114E06 Kvp 57

    a5 gnd

    Abstract: LEMO DB-C4-J11-F db-c4-j11 purple photodiode PCI-1424 C7930DP DIGITAL FRAME image sensor x-ray PCS-E80LKPA
    Text: IMAGE SENSOR Flat panel sensor C7930DP Large area soft X-ray imaging, high resolution Flat panel sensor C7930DP is a digital X-ray image sensor newly developed as a key device for X-ray radiography, etc. This flat panel sensor utilizes our advanced process technology and 12-inch single crystal wafers to acquire high resolution and high quality digital X-ray


    Original
    PDF C7930DP C7930DP 12-inch 14-bit SE-171 KACC1093E04 a5 gnd LEMO DB-C4-J11-F db-c4-j11 purple photodiode PCI-1424 DIGITAL FRAME image sensor x-ray PCS-E80LKPA