Untitled
Abstract: No abstract text available
Text: Agilent V/W281C,D mm-Wave-to Coax Adapters 50 to 110 GHz Product Overview Increased measurement versatility • Excellent repeatability • Measurement versatility • WR-15, WR-10 V,W band waveguide • Precision 1-mm coax connectors V281D V281C 23.33 (.919)
|
Original
|
PDF
|
/W281C
WR-15,
WR-10
V281D
V281C
W281D
W281C
5966-2007E
|
R281A
Abstract: WR22 U281 WR19 R-281-A
Text: Agilent R/Q/U/V281A,B mm-Wave-to-Coax Adapters 26.5 to 65 GHz Technical Overview Dimensions in millimeters A = R281: 19.3 Q281: 28.7 U281: 28.7 • Excellent repeatability • Measurement versatility • WR-28, WR-22, WR-l9, WR-15 R, Q, U, V band waveguide
|
Original
|
PDF
|
R/Q/U/V281A
WR-28,
WR-22,
WR-15
5965-1225E
R281A
WR22
U281
WR19
R-281-A
|
Untitled
Abstract: No abstract text available
Text: WR-15 Instrumentation Grade Waveguide H-Bend with UG-385/U Flange Operating from 50 GHz to 75 GHz TECHNICAL DATA SHEET PE-W15B002 Pasternack’s instrumentation grade waveguide bends are constructed of a high quality oxygen free hard copper with high precision mechanical tolerances as tight as ±0.001” that ensures repeatable and consistent RF performance. Our commercial
|
Original
|
PDF
|
WR-15
UG-385/U
PE-W15B002
WR-12
WR-137
|
Untitled
Abstract: No abstract text available
Text: WR-15 Instrumentation Grade Waveguide E-Bend with UG-385/U Flange Operating from 50 GHz to 75 GHz TECHNICAL DATA SHEET PE-W15B001 Pasternack’s instrumentation grade waveguide bends are constructed of a high quality oxygen free hard copper with high precision mechanical tolerances as tight as ±0.001” that ensures repeatable and consistent RF performance. Our commercial
|
Original
|
PDF
|
WR-15
UG-385/U
PE-W15B001
WR-12
WR-137
|
Untitled
Abstract: No abstract text available
Text: WR-15 Instrumentation Grade Straight Waveguide Section 3 Inch Length with UG-385/U Flange Operating from 50 GHz to 75 GHz TECHNICAL DATA SHEET PE-W15S001-3 Pasternack’s instrumentation grade waveguide sections are constructed of a high quality oxygen free hard copper with high
|
Original
|
PDF
|
WR-15
UG-385/U
PE-W15S001-3
WR-12
WR-137
e-section-ug-385-50-75-ghz-pe-w15s001-3-p
|
Untitled
Abstract: No abstract text available
Text: WR-15 Instrumentation Grade Straight Waveguide Section 12 Inch Length with UG-385/U Flange Operating from 50 GHz to 75 GHz TECHNICAL DATA SHEET PE-W15S001-12 Pasternack’s instrumentation grade waveguide sections are constructed of a high quality oxygen free hard copper with high
|
Original
|
PDF
|
WR-15
UG-385/U
PE-W15S001-12
WR-12
WR-137
UG-385/U
-section-ug-385-50-75-ghz-pe-w15s001-12-p
|
Untitled
Abstract: No abstract text available
Text: WR-15 Instrumentation Grade Straight Waveguide Section 6 Inch Length with UG-385/U Flange Operating from 50 GHz to 75 GHz TECHNICAL DATA SHEET PE-W15S001-6 Pasternack’s instrumentation grade waveguide sections are constructed of a high quality oxygen free hard copper with high
|
Original
|
PDF
|
WR-15
UG-385/U
PE-W15S001-6
WR-12
WR-137
e-section-ug-385-50-75-ghz-pe-w15s001-6-p
|
Untitled
Abstract: No abstract text available
Text: WR-15 Instrumentation Grade Straight Waveguide Section 9 Inch Length with UG-385/U Flange Operating from 50 GHz to 75 GHz TECHNICAL DATA SHEET PE-W15S001-9 Pasternack’s instrumentation grade waveguide sections are constructed of a high quality oxygen free hard copper with high
|
Original
|
PDF
|
WR-15
UG-385/U
PE-W15S001-9
WR-12
WR-137
e-section-ug-385-50-75-ghz-pe-w15s001-9-p
|
Untitled
Abstract: No abstract text available
Text: Agilent V8486A V-Band Power Sensor Profile Your New Choice for Accurate Power Measurements from 50 to 75 GHz Compatible with Your Current Agilent Power Meter The Agilent Technologies V8486A V-band power sensor is fully compatible with Agilent 435B, 436A, 437B, 438A, 70100A, E1416A, E4418A/B, and
|
Original
|
PDF
|
V8486A
V8486A
0100A,
E1416A,
E4418A/B,
E4419A/B
5968-2589E
|
SL242
Abstract: SL242-30 spacek
Text: COMPONENT BROCHURE A SELECTED SAMPLING OF OUR COMPREHENSIVE LINE OF MICROWAVE AND MILLIMETER-WAVE COMPONENTS AND SUBASSEMBLIES FROM 10 TO 110 GHz: Mixers, Up/Down Converters Block Converters Mixer-Preamplifiers Planar Mixers Power Amplifiers Low-Noise Amplifiers
|
Original
|
PDF
|
C14-1
SL242
SL242-30 spacek
|
d8693
Abstract: RYT Circulators amf-3d-008019.1 miteq amf-3f x-band waveguide isolators ps223 TS0303W3 JSD00114 H-BEND
Text: AST Lagerliste 2010 solange r u n f u a Verk icht! Vorrat re Hohlleiter- und Koaxialbauteile, vom Diplexer bis zu Leistungsverstärker, passive Bauteile wie z.B. Leistungswiderständen oder Dämpfungsglieder, und Kabel bis zu 65 GHz werden mit weit über 50% Preisnachlass angeboten.
|
Original
|
PDF
|
AM-1598-11166
AM-1607-10231
AM-1013-0
D-86932
d8693
RYT Circulators
amf-3d-008019.1
miteq
amf-3f
x-band waveguide isolators
ps223
TS0303W3
JSD00114
H-BEND
|
3739C
Abstract: No abstract text available
Text: Technical Data Sheet & Configuration Guide High Performance, Broadband Network Analysis Solutions ME7838D Series Vector Network Analyzers The VectorStar ME7838D 145 GHz Broadband system is the world’s first VNA combining RF, microwave, and two mm-wave bands in a single coaxial output.
|
Original
|
PDF
|
ME7838D
bey3-400
3739C
|
104-330-LC
Abstract: E8361 N5256AW12 N5256AW15 N5256AW10 N5256AX12 N5256AW N5260AC06 16494A WR15 waveguide coax adapt
Text: Agilent Millimeter-Wave Network Analyzers 10 MHz to 110 GHz, with Extensions to 0.5 THz Technical Overview High Performance Bench-Top Network Analyzers • Maximize your frequency coverage with a single sweep from 10 MHz to 110 GHz, and realize measurements to 0.5 THz with frequency extensions
|
Original
|
PDF
|
founda375
5989-7620EN
104-330-LC
E8361
N5256AW12
N5256AW15
N5256AW10
N5256AX12
N5256AW
N5260AC06
16494A
WR15 waveguide coax adapt
|
Untitled
Abstract: No abstract text available
Text: Agilent 8510C Network Analyzer Data Sheet 45 MHz to 110 GHz Discontinued Product Information — For Support Reference Only — Information herein, may refer to products/services no longer supported. We regret any inconvenience caused by obsolete information. For the
|
Original
|
PDF
|
8510C
Analy00
5091-8484E
|
|
8563a
Abstract: 8120-2582 e4407b 71210C 8560A E4440A 8561A 2007A 8562A AGILENT 8563A
Text: Agilent 11974 Series Preselected Millimeter Mixers RF Sections Available in Four Bands from 26.5 to 75 GHz Data Sheet For the first time, preselected signal analysis is available to 75 GHz. With preselection, you can quickly and easily characterize all signals of interest. No images or
|
Original
|
PDF
|
|
8120-2582
Abstract: preselector
Text: Agilent 11974 Series Preselected Millimeter Mixers RF Sections Available in Four Bands from 26.5 to 75 GHz Data Sheet For the first time, preselected signal analysis is available to 75 GHz. With preselection, you can quickly and easily characterize all signals of interest. No images or
|
Original
|
PDF
|
|
APC-7 Calibration Kit
Abstract: BENDIX TEE CONNECTORS
Text: Agilent’s test accessories eliminate the weak links in your measurement system. • Guarantee accurate and repeatable results • Reduce cost of test Online Resources • Locate product and support information with simple navigation to technical overviews, manuals, news releases, education
|
Original
|
PDF
|
5990-8661EN
APC-7 Calibration Kit
BENDIX TEE CONNECTORS
|
N5249A PNA-X Microwave Network Analyzer
Abstract: No abstract text available
Text: Agilent PNA Family Microwave Network Analyzers Configuration Guide This configuration guide describes standard configurations, options, accessories, upgrade kits and compatible peripherals for the PNA Family microwave network analyzers. This guide should be used with the Agilent PNA Family data sheets for
|
Original
|
PDF
|
N5249A
N5241A
N5242A
N5244A
N5245A
N5247A
N5221A
N5222A
N5224A
N5225A
N5249A PNA-X Microwave Network Analyzer
|
Untitled
Abstract: No abstract text available
Text: Agilent 8757D Scalar Network Analyzer Data Sheet Accurate measurement of transmission and reflection characteristics is a key requirement in your selection of a scalar network analyzer. To help you achieve these goals, Agilent Technologies offers you a choice of microwave scalar measurement solutions which provide an excellent balance
|
Original
|
PDF
|
8757D
8757D
5091-2471E
|
8757D
Abstract: 85025CK-K57 11667A 8757A EPM-4418B 9122C HP 11636B IEC-625 11667C 8757 a network
Text: Agilent 8757D Scalar Network Analyzer Data Sheet Accurate measurement of transmission and reflection characteristics is a key requirement in your selection of a scalar network analyzer. To help you achieve these goals, Agilent Technologies offers you a choice of microwave scalar measurement solutions which provide an excellent balance
|
Original
|
PDF
|
8757D
8757D
5091-2471E
85025CK-K57
11667A
8757A
EPM-4418B
9122C
HP 11636B
IEC-625
11667C
8757 a network
|
transistor SI 6823A
Abstract: transistor SI 6822 SI 6822 transistor 6823a SI 6823a c5487 cts ocxo 10MHz 6823A dot matrix printer circuit diagram datasheet Si 6823
Text: Contents RF & MICROWAVE SCALAR ANALYZERS 6820A SERIES and RF & MICROWAVE SYSTEM ANALYZERS 6840A SERIES Operating Manual Document part no. 46892/920 OPERATING MANUAL RF & MICROWAVE SCALAR ANALYZERS 6820A SERIES and RF & MICROWAVE SYSTEM ANALYZERS 6840A SERIES
|
Original
|
PDF
|
|
CRT - TCL COLOUR TV SCHEMATIC DIAGRAM
Abstract: MATSUA compressor catalogue Riyadh Cables Catalogue PD 18N50 equivalent MATSUSHITA compressor catalogue CRT TCL COLOUR TV SCHEMATIC DIAGRAM Anritsu ML524B operation manual ML2430 CRT - tcl 29" COLOUR TV SCHEMATIC DIAGRAM Anritsu MG442A
Text: CONTENTS Outline of Anritsu Corporation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 How to Use This Catalog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Sales, Shipping, and Service Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
|
Original
|
PDF
|
|
LN 9499 03 075
Abstract: AFS4 LN 9499 miteq c-22 AFS2 Miteq
Text: Back to Amplifier Home Page AFS/JS AMPLIFIERS Table Of Contents Introduction Amplifier Models • Amplifiers By Frequency • Amplifiers By Category • Specialized Amplifiers • Typical JS Series Amplifier Performance Outline Drawings Amplifier Accessories
|
Original
|
PDF
|
2002/96/EC
LN 9499 03 075
AFS4
LN 9499
miteq c-22
AFS2 Miteq
|
AGILENT A 1610 OPTICAL MOUSE SENSOR
Abstract: siemens transistor manual COTS high-accuracy clock sources Delay linear sweep generator using 555 timer
Text: Agilent PNA Series Network Analyzer Printed Version of PNA Help User’s and Programming Guide Supports Firmware A.08.00 March 12, 2008 Warranty Statement THE MATERIAL CONTAINED IN THIS DOCUMENT IS PROVIDED “AS IS,” AND IS SUBJECT TO BEING CHANGED, WITHOUT NOTICE, IN FUTURE EDITIONS. FURTHER, TO THE
|
Original
|
PDF
|
Z5326A
AGILENT A 1610 OPTICAL MOUSE SENSOR
siemens transistor manual
COTS high-accuracy clock sources
Delay linear sweep generator using 555 timer
|