Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    WAVEGUIDE GASKETS Search Results

    WAVEGUIDE GASKETS Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    MRJ258A21BP Amphenol Communications Solutions MRJ Series, Panel Gasket Visit Amphenol Communications Solutions
    FLA2N04BP Amphenol Communications Solutions FLA Panel Gasket NEMA ANSI C136.41, Silicone Rubber, Black Visit Amphenol Communications Solutions
    FLA2N01BP Amphenol Communications Solutions FLA Panel Gasket NEMA ANSI C136.41, EPDM Rubber, Black Visit Amphenol Communications Solutions
    MRJ258A41BP Amphenol Communications Solutions Rugged Modular Jack Accessory, Input Output Connector, Panel Gasket, Conductive, Black Color Visit Amphenol Communications Solutions
    FLA014130R1 Amphenol Communications Solutions FLA Receptacle NEMA ANSI C136.41, 3 Power, No Signal, 14AWG, 105C, with Panel Gasket Silicone Rubber Visit Amphenol Communications Solutions

    WAVEGUIDE GASKETS Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    M83528

    Abstract: WR340 flange dimensions OSD-6411A wr 2300 flange waveguide Waveguide Gaskets 20-03-3731-1212 CMR-137 WR137 gasket dimensions RG-106 wr 2300 waveguide flange
    Text: CONDUCTIVE ELASTOMERS Waveguide Gaskets Waveguide Gaskets CHO-SEAL CHO-SEAL 1212 1239 SPECIFICATIONS Type Ref: MIL-G-83528 Volume Resistivity (ohm-cm, max) as supplied (without pressure-sensitive adhesive) K G 0.005 0.007 Hardness (Shore A ±5) 80 80 Specific Gravity (±0.25)


    Original
    PDF MIL-G-83528) M83528 WR340 flange dimensions OSD-6411A wr 2300 flange waveguide Waveguide Gaskets 20-03-3731-1212 CMR-137 WR137 gasket dimensions RG-106 wr 2300 waveguide flange

    GLW1500

    Abstract: GLW-1350 waveguide transition ELBOW WR1500 GLW1750 GLW1700 wr -34 flange waveguide
    Text: GUIDELine Circular Waveguide GUIDELine low attenuation waveguide is the premier transmission line for use in UHF television transmitting antenna systems. It offers highest possible efficiency, handles maximum power and has lower windload than rectangular waveguides. The unique design offers superior polarization stability and eliminates the need for on-site


    Original
    PDF GLW1350, GLW1500, GLW1700, GLW1750 GLW1500 GLW-1350 waveguide transition ELBOW WR1500 GLW1750 GLW1700 wr -34 flange waveguide

    MIL-W-85

    Abstract: WR340 half height flange wr 2300 flange waveguide GSK90-1-S GASKET Waveguide Gaskets WR340 waveguide directional coupler wr 90 directional coupler wr 2300 waveguide RCC42 wr 90 x band flange waveguide
    Text: • RECTANGULAR WAVEGUIDE SECTION CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS-101 DS-102 DS-103 DS-104 DS-105 DS-106 DS-107 DS-108 DS-109 DS-110 DS-111 Directional Couplers . .


    Original
    PDF DS-101 DS-102 DS-103 DS-104 DS-105 DS-106 DS-107 DS-108 DS-109 DS-110 MIL-W-85 WR340 half height flange wr 2300 flange waveguide GSK90-1-S GASKET Waveguide Gaskets WR340 waveguide directional coupler wr 90 directional coupler wr 2300 waveguide RCC42 wr 90 x band flange waveguide

    TP116

    Abstract: WR975 waveguide AJ2194 circuit diagram of door interlock system magnetron 10 kw CPR975 BURLE-AJ2192 AJ2136V2 AJ2135 magnetron
    Text: Return To Product Page S94600E Magnetron Large Power Magnetron For Industrial Applications • • • • Ceramic-Metal Construction 50 kW CW at 915MHz All Magnetron Support Equipment Available Full Operating Guidance The BURLE S94600E is a fixed-tuned, magnetically


    Original
    PDF S94600E 915MHz S94600E AJ2192 TP116 WR975 waveguide AJ2194 circuit diagram of door interlock system magnetron 10 kw CPR975 BURLE-AJ2192 AJ2136V2 AJ2135 magnetron

    TP116

    Abstract: AJ2194 AJ2135 WR975 waveguide AJ2136V2 AJ-2194 power supply magnetron power supply for magnetron BURLE-AJ2137V1 CPR975F
    Text: Return To Product Page 8684 Magnetron Large Power MagnetronFor Industrial Applications • • • • Ceramic-Metal Construction 30 kW CW at 915 MHz All Magnetron Support Equipment Available Full Operating Guidance The BURLE 8684 is a fixed-tuned, magnetically


    Original
    PDF

    WR975 waveguide

    Abstract: power supply for magnetron magnetron 10 kw AJ2135 AJ2136V2 LS-5148 WR975 stub tuner waveguide AJ2192 LS51
    Text: RETURN TO MENU TP-116 Large Power Magnetrons Application Note Application Guide For BURLE Large Power Magnetrons BURLE magnetrons are built to generate tens increases, operating procedures and tube pro- of kilowatts of cw power at 915 MHz 896 MHz tection techniques become increasingly critical. Close attention to the installation, operation


    Original
    PDF TP-116 AN-4985 AJ2192 92LS-5131 CPR975F 92LS-5130 AJ2194 LS-5148 WR975 waveguide power supply for magnetron magnetron 10 kw AJ2135 AJ2136V2 LS-5148 WR975 stub tuner waveguide LS51

    177DZ

    Abstract: elliptical waveguide EWP63S EW37 waveguide elliptical EW77 EW64 waveguide ew64 143Z EWP43
    Text: Accessories A Splice. B Hoisting Grip used at 200 ft 60 m intervals to raise waveguide on tower. C Bending Tool Kit for elliptical waveguide installation. One each E- and H-plane form included. D Connector Reattachment Kit includes rubber gasket parts (except flange gaskets) which may need


    OCR Scan
    PDF EWP34 EWP37, EWP43 EWP52, EWP63S EWP64 128AZ 134DZ 137DZ 152DZ 177DZ elliptical waveguide EW37 waveguide elliptical EW77 EW64 waveguide ew64 143Z

    WS108

    Abstract: WC166 WC281 Waveguide Gaskets CPR159G CPR-137 circular waveguide
    Text: Circular-to-Rectangular Waveguide Transitions A Term ination Load for unused rectangular waveguide port of dual-polarized transitions. Maximum VSWR is 1.02 within the operating bands specified for transitions. Pressurizable. F la n g e Type Lo ad Type No.


    OCR Scan
    PDF CPR90G CPR112G CPR137G CPR159G CPR229G WR112 WR137 WC281 WC166 WC109 WS108 Waveguide Gaskets CPR-137 circular waveguide

    waveguide transition

    Abstract: Wc waveguide ELBOW WR1500 wr -34 flange waveguide
    Text: GU IDELin e Circular Waveguide li rüculüiiiit Aiiteiuis. Systems GUIDELine low attenuation waveguide is the premier transmission line for use in UHF television transmitting antenna systems. It offers highest possible efficiency, handles maximum power and has lower windload than


    OCR Scan
    PDF GLW1350, GLW1500, GLW1700, GLW1750 waveguide transition Wc waveguide ELBOW WR1500 wr -34 flange waveguide

    WC166

    Abstract: WC281 WC109 elliptical waveguide flexible waveguide 4 port combiner sliding
    Text: A Alignment Shorting Plate. A brass plate used during initial alignment. It is installed at the top of the run while the axial ratio compensator is adjusted. See table below. B Pulling Head. Attaches to top waveguide section flange. Waveguide sections can be assembled at


    OCR Scan
    PDF WC281 WC166 WC109 elliptical waveguide flexible waveguide 4 port combiner sliding

    WC281

    Abstract: No abstract text available
    Text: M ic ro w a v e T ra n s m is s io n Lin es Circular W aveguide Low est Attenuation Circular waveguide offers substantially lower attenuation than elliptical or rectangular waveguide. This can result in the use of smaller antennas, reducing tower loading and saving antenna cost.


    OCR Scan
    PDF 8600A-1- 8600A-2- 8613A-150- 8613A-96- 8613A- WC281

    wr1500 55

    Abstract: GLW1500
    Text: B ro a d c a s t A n te n n a S y s te m s GUIDELine Circular Waveguide GUIDELine low attenuation waveguide is the premier transmission line for use in UHF television transmitting antenna systems. It offers highest possible efficiency, handles maximum power and has lower windload than


    OCR Scan
    PDF GLW1750 GLW1700 GLW1500 GLW1350 wr1500 55

    andrew ew 90

    Abstract: EW17 33586 1127D EW 90 EWP63 EW20 P127A EWP34 EW77
    Text: Accessories A S p lic e . B H o is tin g G rip used at 200 ft 60 m intervals to raise waveguide on tower. C B e n ding Tool Kit for elliptical waveguide installation. One each E- and H-plane form included. D C on n e cto r R e a tta c h m e n t Kit includes rubber gasket


    OCR Scan
    PDF 1127D GB4-43 GB4-52 GB4-63 GB4-64 GB5-43 GB5-52 GB5-63 GB5-64 P127A andrew ew 90 EW17 33586 EW 90 EWP63 EW20 EWP34 EW77

    WC281

    Abstract: No abstract text available
    Text: Circular W aveguide Straight Sections Andrew circular waveguide is made of heavy-wail high conductivity copper tubing, specially coated to prevent corrosion and deterioration of attenuation characteristics. Stainless steel hardware and flange gaskets are included.


    OCR Scan
    PDF

    WC281

    Abstract: WC166 WC109 WC269 WR75 waveguide WC212 3642 CPR159G rectangular waveguide transition CPR-159G
    Text: A Termination Load for unused rectangular waveguide port of dual-polarized transitions. Maximum VSWR is 1.02 within the operating bands specified for transitions. Pressurizable. Flange Type Load Type No CPR90G CPR112G CPR137G CPR159G CPR229G WR75 Cover/Gasket


    OCR Scan
    PDF CPR90G CPR112G CPR137G CPR159G CPR229G WR112 WC281. WC281 WC281ransitions WC166 WC109 WC269 WR75 waveguide WC212 3642 rectangular waveguide transition CPR-159G

    WC281

    Abstract: CPR229G elliptical waveguide UG-595U WC166
    Text: M icrow ave Transm ission Lines Single Polarized Without Mode Filter Single Polarized With Mode Filter Circular-to-Rectangular Waveguide Transitions These transitions convert from circular to rectangular waveguides at one or both ends of the vertical run.


    OCR Scan
    PDF PDR100 PDR120 UG-596A/U, UG-595U CBR220, UBR220, PBR220 WC281 CPR229G elliptical waveguide UG-595U WC166

    R-137

    Abstract: WR90 round flange CMR159 UAR70 CMR-187 CMR229 UBR100 UER100 flange dimensions CMR-229 CMR90
    Text: Rectangular Waveguide Flanges A majority of Andrew standard flanges utilized in North America are based on EIA Electronic Industry Association or U. S. Military (MIL) standards. IEC (International Electrotechnical Commission) standards are utilized throughout other parts of the world. EIA,


    OCR Scan
    PDF

    WR137 gasket dimensions

    Abstract: PAR32 CBR84 gasket flanges UBR100 flange PBR120 UBR-120 CBR140 PBR-220
    Text: Choke, Cover and Cover/Gasket Flanges Choke, cover and cover/gasket flanges are square or round, depending on waveguide size. U. S. MIL and IEC versions are interchangeable. The flanges are pressurizable and require gaskets to ensure proper sealing. The flanges mate as explained below and as specified in the


    OCR Scan
    PDF UG-595/U UG-419/U UB-39/U UG-51/U UG-344/U UG-149A/U UG-53/U UBR220 UBR140 UBR120 WR137 gasket dimensions PAR32 CBR84 gasket flanges UBR100 flange PBR120 UBR-120 CBR140 PBR-220

    UER70

    Abstract: UER84 WR137 flange dimensions UER100 flange dimensions CMR-187 rectangular waveguide CMR159 flanges CMR90
    Text: Rectangular Waveguide Flanges A majority of Andrew standard flanges utilized in North America are based on EIA Electronic Industry Association or U. S. Military (MIL) standards. IEC (International Electrotechnical Com m ission) standards are utilized throughout other parts of the world. EIA, MIL and IEC


    OCR Scan
    PDF WR137 UER100 UER84 UER70 UER58 UER48 UER40 WR137 flange dimensions UER100 flange dimensions CMR-187 rectangular waveguide CMR159 flanges CMR90

    Untitled

    Abstract: No abstract text available
    Text: PBtttt G E C P L E S S E Y DS3541-1.1 F1052-57 HIGH POWER WAVEGUIDE DIFFERENTIAL PHASE SHIFT CIRCULATORS * FREQUENCY COVERAGE 2.7 to 37.0GHz * HIGH-POWER CAPABILITY This data sheet describes a range of 4-port differential phase shift circulators that may also be


    OCR Scan
    PDF DS3541-1 F1052-57 F1052 F1054 F1056 F1057 F1053 UBR84

    WC281

    Abstract: No abstract text available
    Text: M ic ro w a v e T ra n s m is s io n L in es Accessories A Alignment Shorting Plate. A brass plate used during initial alignment. It is installed at the top of the run while the axial ratio compensator is adjusted. See table below. B Pulling Head. Attaches to top waveguide section


    OCR Scan
    PDF WC281 3555A

    WR137 gasket dimensions

    Abstract: WR340 flange dimensions Waveguide Gaskets WR187 PDR120 CPR-340F UG-1352 pdr84 to pdr70 PDR48 Waveguide Gaskets Waveguide Gaskets wr90
    Text: Pressurizable Contact Flanges CPR and PDR series contact flanges are rectangular in shape and have clear holes secured with bolts and nuts. The flanges are pressurizable and require gaskets to ensure proper sealing. The flanges mate as explained below and as specified in the Mating Information table.


    OCR Scan
    PDF CPR90F CPR112F CPR137F CPR159F CPR187F CPR229F CPR284F CPR340F CPR430F UG-1736/U WR137 gasket dimensions WR340 flange dimensions Waveguide Gaskets WR187 PDR120 CPR-340F UG-1352 pdr84 to pdr70 PDR48 Waveguide Gaskets Waveguide Gaskets wr90

    cmr137 flange

    Abstract: IEC154 WR51 CPR112G IEC154-2 WR90 waveguide transition CMR-187 pressure inlet andrew CPR229G CMR-137
    Text: M ic ro w a v e T ra n s m is s io n Lin es Common F lange A d a p ters Flange Type UG-51/U UG-52B/U UG Cover / Gasket CMR90 CMR112 CMR137 Transition to Type N Female Flange Adapters are available in many commonly used configurations, and when used with standard components,


    OCR Scan
    PDF UG-51/U UG-52B/U CMR90 CMR112 CMR137 CMR159 CMR187 CMR229 CPR112G cmr137 flange IEC154 WR51 IEC154-2 WR90 waveguide transition CMR-187 pressure inlet andrew CPR229G CMR-137

    stainless steel s130

    Abstract: st 212 coaxial cable RS625 circular waveguide
    Text: A lp habetical Ind ex Description Page Description Page Special A p p lica tio n . 717, 718 ValuLine . 127-149 ACE Bidirectional A m p lifie rs .678-681 W ireless T ele p h o n e .439


    OCR Scan
    PDF WC281 stainless steel s130 st 212 coaxial cable RS625 circular waveguide