Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    WATER BALL VALVE Search Results

    WATER BALL VALVE Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    Water-Quality-Tester Renesas Electronics Corporation Water Quality Tester Reference Design Visit Renesas Electronics Corporation
    CTSU2-WATERPROOF-BUTTON Renesas Electronics Corporation Self-Capacitance Waterproof Button Solution Visit Renesas Electronics Corporation
    D6417750RBP240DV Renesas Electronics Corporation 32-bit Microcontrollers, BGA, / Visit Renesas Electronics Corporation
    HD6417750RBP240 Renesas Electronics Corporation 32-bit Microcontrollers, BGA, / Visit Renesas Electronics Corporation
    HD6417750RBP200V Renesas Electronics Corporation 32-bit Microcontrollers, BGA, / Visit Renesas Electronics Corporation

    WATER BALL VALVE Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    Untitled

    Abstract: No abstract text available
    Text: MANUAL AND AUTOMATED PLASTIC VALVES Ball and Diaphragm Versions From $ 19 MADE IN USA OMEGA offers a wide selection of plastic valves suitable for liquid service not for use in compressed air service . SPECIFICATIONS Fluid Temperature/Pressure Range: NOTE: All pressure/temperature ratings


    Original
    FVL5305-CLC FVL5307-CLC FVL5310-CLC FVL5312-CLC FVL5315-CLC FVL5320-CLC FVL5312-CLC, PDF

    Untitled

    Abstract: No abstract text available
    Text: 新製品紹介 高速電動式セグメントボールバルブ High Speed Electric Motor Drive of Segment Ball Valve Automatic stainless valve:MTBU1FW7-300 下水処理場で砂などを含む流水配 が,バルブ開閉時間がエアシリン ボールバルブの断面図でバルブ内部


    Original
    MTBU1FW7-300 PDF

    NORGREN -HERION

    Abstract: EXHAUST olympian T15-600-E2AD T15-800-100 b2ad Norgren T15-800-E2AD t15-600-b2ad water BALL VALVE DATA SHEET
    Text: T15 Olympian Shut-off & Lockout Valves 3/4", 1", 1 1/4", 1 1/2" Port Sizes ● Olympian plug in design ● Quick action 1/4 turn from full flow to exhaust ● T15 3-port/2-position shut-off valves with exhaust ● Valves can be locked in open or closed position


    Original
    PDF

    water BALL VALVE

    Abstract: BALL VALVE 6021121C8 602113148EX 602113128EX 601812128 ISO228-1 f4444 6021121B8 6021121F8
    Text: Brass Ball Valves 60 Series 1⁄ 8" – 4" BSP ● Ideally suited for most industrial applications ● Easy installation, simple operation and maintenance free ● Full bore passage giving minimum flow resistance Technical Data Ordering Information Medium:


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: UNDERSTANDING CHEMICAL FEED PUMPS hemical feed pumps have fitting. Cut the tubing at the length many names. Whether needed to hold the foot valve strainer they're called chlorinators, about two inches above the bottom of feeders, injectors or positive the chemical tank. Connect the tubing


    Original
    PDF

    V4073A

    Abstract: wiring diagram for water pump motor operated valve honeywell v4073a 40002737-003 BALL VALVE DATA SHEET 272742A 40003916-003 THERMOSTAT for boiler 42002116-001
    Text: I N S TA L L AT I O N INSTRUCTIONS V4073A Motorised Mid-Position Valve Application The V4073A valve has been designed to control the flow of water in a small bore domestic central heating system where both radiator and hot water cylinder circulation are pumped.


    Original
    V4073A 30-240V 95C-10820-1 wiring diagram for water pump motor operated valve honeywell v4073a 40002737-003 BALL VALVE DATA SHEET 272742A 40003916-003 THERMOSTAT for boiler 42002116-001 PDF

    Untitled

    Abstract: No abstract text available
    Text: OMEGA-FLO 2-WAY BALL VALVES WITH ELECTRICAL ACTUATOR SV-800 Series 940 $ Basic Unit ߜ Ideal for Corrosive or Difficult Fluids ߜ Motor Brake Standard for Precise Position Cutoff ߜ NEMA-4X IP65 Rating The SV-800 Series electrically actuated ball valves feature a PVC


    Original
    SV-800 Actua10 SV-801 SV-802 SV-803 SV-804 SV-805 SV-803 PDF

    Untitled

    Abstract: No abstract text available
    Text: PRESSURE AND FLOW TEST VALVE ASSEMBLY For Hydraulic Systems $ 295 Basic Unit MADE IN USA Model FL-KIT Test Valve Assembly KIT Shown smaller than actual size ߜ Combine Pressure and Flow Measurement ߜ Diagnose Hydraulic Systems in the Field–Avoid Costly


    Original
    FL-6000, FL-7000, FL-8000 1-800-TC-OMEGAÂ FL-6000 FL-7000 FL-8000 PDF

    AMG350C

    Abstract: AMG250C AMg-EL BALL VALVE AMG550C AMG650 AM-BM102 AMG150C AMG450C AMG-EL450
    Text: Water Separator Series AMG Can remove water droplets in compressed air. Use this product in cases where “water must be avoided, but not so dry as when an air dryer is used”. Through the adoption of an element that is exclusively used for removing water droplets and the ample housing interior space, a 99%∗ water removal rate∗∗ has been achieved.


    Original
    AMG650 AMG850 AMG350C AMG250C AMg-EL BALL VALVE AMG550C AMG650 AM-BM102 AMG150C AMG450C AMG-EL450 PDF

    water BALL VALVE

    Abstract: bs 970 AE30CV 10H155 AE30c BALL VALVE
    Text: Issued September 2000 314-2034 Data Pack G AE30 Automatic Air Vent for Water Systems Data Sheet RS stock number 365-6836 365-6842 Description The AE30 range of automatic air vents are designed for use on hot and cold water installations. The body and cap are of a special


    Original
    AE30B AE30C AE30C. AE30C water BALL VALVE bs 970 AE30CV 10H155 BALL VALVE PDF

    SV2002

    Abstract: No abstract text available
    Text: OMEGA-FLO TM “BLACK MUSHROOM” ANGLE SEAT VALVES 2-Way Piston-Operated Valves for Liquids, Gases and Steam, 1⁄2" to 2" NPT SV-2000 Series 142 $ Basic Unit ߜ Ideal Alternative to Complex Actuated Ball Valves ߜ Ideal for All Neutral and Some Aggressive Fluids


    Original
    SV-2000 SV-2025, SV2002 PDF

    Untitled

    Abstract: No abstract text available
    Text: Magnetic Float Level Switch visit our website INTRODUCTION PRINCIPLE The single unit or multiple reed switch units are housed tightly in stainless steel or engineering plastic stem, and the permanent magnet is sealed into the middle of the specified float


    Original
    D-65428 08-FD-B0-EP, PDF

    PH 41113

    Abstract: MYS 99 725 ABB inverter motor fault code MYS 99 003
    Text: ProMinent Product Catalog S e c t i o n Ta b R e f e r e n c e Table of Contents. II SECTION TABS PA G E 1 PA G E 2 7 PA G E 6 7  Solenoid & motor pump overview


    Original
    60x2-0 180x2-0 180x2-1 300x2-2 300x2-3 PH 41113 MYS 99 725 ABB inverter motor fault code MYS 99 003 PDF

    siemens modem gsm tc35

    Abstract: siemens tc35 abb aquamaster tc35 gsm GSM based remote water pump control system program BS1042 aquaMaster S tc35 siemens vodafone flow measurement as per BS1042
    Text: Data Sheet SS/AQUAP2 Insertion-Type Electromagnetic Probe Flowmeter Issue 9 AquaProbe 2 „ Now available for use with CheckMaster, Explorer and MagMaster – an innovative, portable validation resource „ Excellent accuracy over wide operating flow range in both forward and reverse flow directions


    Original
    PDF

    SS-43GS4

    Abstract: Swagelok 3way CROSSOVER SS-43GS6MM
    Text: www.swagelok.com O ne -Pie ce Instr ume ntation Ball Valve s 40 G Se r ie s a nd 40 Se r ie s • On-off, switching, and crossover flow paths ■ Working pressures up to 3000 psig 206 bar ■ Temperatures from –65 to 300°F (–53 to 148°C) ■ Environmental and heated-process applications


    Original
    -WV4T49-2, -WV6MT10-50M -SC11 MS-02-331 SS-43GS4 Swagelok 3way CROSSOVER SS-43GS6MM PDF

    Untitled

    Abstract: No abstract text available
    Text: TURBINE AND PADDLEWHEEL FLOWMETERS Flow Reference Section INTRODUCTION Operation Turbine flowmeters continue to be the most popular way to measure flow electronically in a wide range of industries. A review of the advantages turbine flowmeters have to offer provides insight into


    Original
    FP-5000 PDF

    Untitled

    Abstract: No abstract text available
    Text: HOW TO SELECT YOUR ROTAMETER This article is intended to help the user to select the best rotameter/variable area meter for a particular application. For general information on these flowmeters, please refer to the “Variable Area Flowmeters” flow reference section.


    Original
    PDF

    Telemecanique LIMIT SWITCH XCK-J

    Abstract: Telemecanique LIMIT SWITCH XCK-S telemecanique limit switch catalogue telemecanique manual nautilus Telemecanique LIMIT SWITCH XCK-M XURK0955D XUB0APSNM12 telemecanique osiswitch Telemecanique LIMIT SWITCH XCK-J 59 Telemecanique XSC
    Text: Detection The essential guide Detection A complete range of innovative and much more simple to use sensors Benefit from Telemecanique’s major innovation: A worldwide detection first for improving productivity. A complete offer for resolving your most commonly


    Original
    DIA4ED2041203EN Telemecanique LIMIT SWITCH XCK-J Telemecanique LIMIT SWITCH XCK-S telemecanique limit switch catalogue telemecanique manual nautilus Telemecanique LIMIT SWITCH XCK-M XURK0955D XUB0APSNM12 telemecanique osiswitch Telemecanique LIMIT SWITCH XCK-J 59 Telemecanique XSC PDF

    MLO-8515

    Abstract: BSPP fittings torque nitrogen coupling material safety for nitrile rubber parker valves hydraulic rubber hose BSPp torque A-200 MIL H 5606 hose and hose fittings
    Text: Issued July 1995 019-969 Data Pack G Quick action couplings Data Sheet Technical specification Body material –––––––––––– Mild steel with zinc plated and yellow passivated finish Seals –––––––––––––––––––––––––––––– Nitrile rubber


    Original
    PDF

    BALL VALVE for hot water

    Abstract: A-200 BSPP fittings torque Petrolatum Lubricant nitrogen coupling benzene octane nbr brake fluid parker connect fitting pydraul A200 dow corning silicone compound
    Text: Issued March 1997 232-5474 Data Pack G Quick action couplings Data Sheet Technical specification Body material –––––––––––– Mild steel with zinc plated and yellow passivated finish Seals –––––––––––––––––––––––––––––– Nitrile rubber


    Original
    PDF

    lubricant

    Abstract: eml05p EML05L contact cleaner electrical solvent cleaner RG10 EML400D silica sand electrical solvent cleaner safety water BALL VALVE
    Text: PAGE: SAFETY DATA SHEET PRINT DATE: REF: 1 of 3 05/08/1997 EML05P / EML05L 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND THE COMPANY/UNDERTAKING Product name: CONTACT CLEANER LUBRICANT Product code: EML05P / EML05L Supplier: ELECTROLUBE H.K. Wentworth Ltd.,


    Original
    EML05P EML05L 200ml 400ml EML200F EML400D EML05P lubricant EML05L contact cleaner electrical solvent cleaner RG10 EML400D silica sand electrical solvent cleaner safety water BALL VALVE PDF

    descaler

    Abstract: boiler chemicals x100 sentinel water BALL VALVE
    Text: Issued March 1997 232-3901 Data Pack K Sentinel inhibitors and cleansers Data Sheet Product selection Application instructions A range of Sentinel products which is safe to use in all systems including those containing aluminium. The appropriate product may be selected from the following table:


    Original
    PDF

    Honeywell C7195A2001B

    Abstract: ML7421A1032-E ML7420A6033-E T6861H2WB CN7510A2001 honeywell damper actuator manual C7195A2001B ML7421B1023-E CN7510A2001 CN7505A2001 UEC24014M262
    Text: ECC products Product Catalogue - Pacific ISSUED MARCH 2008 Contact Us ECC products & Combustion Controls Environmental Phone Fax AUS 02 9353 7400 7500 (NZ) 0800 20 20 88 (NZ) 0800 20 20 88 (AUS) 1300 360 470 (NZ) 0800 20 20 86 Email eccproducts@honeywell.com


    Original
    PDF

    ETP08

    Abstract: water BALL VALVE ABB pressure transmitter etp08 ABB sensor absolute pressure ETP08-XXXX "Pressure transmitter" type 501 ISO2852 Varivent P1093 DIN11851
    Text: ETP08 Electronic Transmitter for Pressure and Level The ETP08 is a series of pressure transmitters with a wide range of connections to suit most applications. The transmitters can measure liquids, gases, vapours and can be used for hydrostatic level measurements in open


    Original
    ETP08 ETP08 0945en0209 water BALL VALVE ABB pressure transmitter etp08 ABB sensor absolute pressure ETP08-XXXX "Pressure transmitter" type 501 ISO2852 Varivent P1093 DIN11851 PDF