Text: 8798_AA's Vectron 05/30/02 3:11 PM Page 62 Temperature Compensated Crystal Oscillators TCXO’s Additional TCXO’s P-5 Features • Standard-TCXO • Up to 35MHz • -40 to +85°C, -20 to +70°C, 0 to +50°C • HCMOS; Sinewave • 36 x 27 x 10 mm Pin 1
|
Original
|
PDF
|
35MHz
1-88-VECTRON-1
|
C2260A1-0108
Abstract: DIN IEC 68 Vectron TCXO to 70 MHz din IEC 68 150
Text: VECTRON INTERNATIONAL TCXO C2260A1-0108 Nominal frequency f0 20 MHz Frequency stabilities Parameter Frequency stability Operating temp. range vs. operating temp. range (df/f@25 °C) -0.28 to 0.28 ppm -0.28 to 0.28 ppm 0 . 70 °C 10 . 40 °C Parameter
|
Original
|
PDF
|
C2260A1-0108
D-74924
C2260A1-0108
DIN IEC 68
Vectron TCXO to 70 MHz
din IEC 68 150
|
Untitled
Abstract: No abstract text available
Text: VECTRON INTERNATIONAL TCXO C2260A1-0021 Revision : 5 Nominal frequency f0 20 MHz Frequency stabilities Parameter Frequency stability Operating temp. range Over all (df/f0) vs. operating temp. range (df/f@25 °C) -4.6 to 4.6 ppm -0.28 to 0.28 ppm -20 . 70 °C
|
Original
|
PDF
|
C2260A1-0021
GR-1244-CORE:
D-74924
|
C2260A1-0028
Abstract: GR-1244-CORE 12M800 Vectron TCXO to 70 MHz
Text: VECTRON INTERNATIONAL TCXO C2260A1-0028 Nominal frequency f0 12.8 MHz Frequency stabilities Parameter Frequency stability Operating temp. range Over all (df/f0) vs. operating temp. range (df/f@25 °C) -4.6 to 4.6 ppm -0.28 to 0.28 ppm -20 . 70 °C Value
|
Original
|
PDF
|
C2260A1-0028
GR-1244-CORE:
D-74924
C2260A1-0028
GR-1244-CORE
12M800
Vectron TCXO to 70 MHz
|
G287
Abstract: ocxo tcxo VECTRON CO-251A57-V
Text: TCXO C2261 Typical Applications Features PCS Base Stations Land Mobile Radio Cellular Telephony Radio in the Local Loop EFC Standard Low Profile Small Size 100 % RoHS compliant Available standart frequencies 10; 12; 12.8; 20; 25.6; 26 MHz Frequency stabilities1 [ Stratum 3 TCXO]
|
Original
|
PDF
|
C2261
D-74924
G287
ocxo tcxo
VECTRON CO-251A57-V
|
b507
Abstract: No abstract text available
Text: TCXO TX-702 Typical Applications Features PCS Base Stations Land Mobile Radio Cellular Telephony Radio in the Local Loop EFC Standard Low Profile Small Size 100 % RoHS compliant Frequency range 50 MHz – 1 GHz Standard frequencies 100; 122,88; 155,52; 311,04; 622,08MHz
|
Original
|
PDF
|
TX-702
08MHz
D-74924
b507
|
F287
Abstract: 2F P marking G204 B507 g287 C2260A1-0032 vectron tcxo 16,384 B106 VECTRON INTERNATIONAL PART MARKING C2260
Text: TCXO C2260 Typical Applications Features PCS Base Stations Land Mobile Radio Cellular Telephony Radio in the Local Loop EFC Standard Low Profile Small Size 100 % RoHS compliant Frequency range 6.4 MHz – 52 MHz Standard frequencies 10; 12.8; 16.384; 19.44; 20; 20.48MHz
|
Original
|
PDF
|
C2260
48MHz
D-74924
F287
2F P marking
G204
B507
g287
C2260A1-0032
vectron tcxo 16,384
B106
VECTRON INTERNATIONAL PART MARKING
C2260
|
C2261
Abstract: G287 ocxo tcxo D807 F287
Text: TCXO C2261 Typical Applications Features PCS Base Stations Land Mobile Radio Cellular Telephony Radio in the Local Loop EFC Standard Low Profile Small Size 100 % RoHS compliant Available standart frequencies 10; 12; 12.8; 20; 25.6; 26 MHz Frequency stabilities1 [ Stratum 3 TCXO]
|
Original
|
PDF
|
C2261
D-74924
C2261
G287
ocxo tcxo
D807
F287
|
C2260
Abstract: No abstract text available
Text: TCXO C2260 Typical Applications Features PCS Base Stations Land Mobile Radio Cellular Telephony Radio in the Local Loop EFC Standard Low Profile Small Size 100 % RoHS compliant Frequency range 6.4 MHz – 52 MHz Standard frequencies 10; 12.8; 16.384; 19.44; 20; 20.48MHz
|
Original
|
PDF
|
C2260
48MHz
D-74924
C2260
|
C2530
Abstract: D206 b507 Corning Frequency Control B106 B287 D106 D287 D807
Text: TCXO C2530 Typical Applications Features PCS Base Stations Land Mobile Radio Cellular Telephony Radio in the Local Loop Wide Frequency range EFC Standard Standard Surface Mount Package Meets Stratum 3 Previous Corning Model Numbers STO200 Frequency range 30 MHz – 900 MHz
|
Original
|
PDF
|
C2530
STO200
D-74924
C2530
D206
b507
Corning Frequency Control
B106
B287
D106
D287
D807
|
corning
Abstract: D-206
Text: TCXO C2530 Typical Applications Features PCS Base Stations Land Mobile Radio Cellular Telephony Radio in the Local Loop Wide Frequency range EFC Standard Standard Surface Mount Package Meets Stratum 3 Previous Corning Model Numbers STO200 Frequency range 30 MHz – 900 MHz
|
Original
|
PDF
|
C2530
STO200
D-74924
corning
D-206
|
F287
Abstract: VECTRON INTERNATIONAL PART MARKING HG211
Text: TCXO C2260 Typical Applications Features PCS Base Stations Land Mobile Radio Cellular Telephony Radio in the Local Loop EFC Standard Low Profile Small Size 100 % RoHS compliant Frequency range 6.4 MHz – 52 MHz Standard frequencies 10; 12.8; 19.44; 20MHz, 20.48MHz
|
Original
|
PDF
|
C2260
20MHz,
48MHz
D-74924
F287
VECTRON INTERNATIONAL PART MARKING
HG211
|
32-MHz
Abstract: VECTRON INTERNATIONAL PART MARKING
Text: TCXO C2260 Typical Applications Features PCS Base Stations Land Mobile Radio Cellular Telephony Radio in the Local Loop EFC Standard Low Profile Small Size 100 % RoHS compliant Frequency range 6.4 MHz – 52 MHz Standard frequencies 10; 12.8; 19.44; 20MHz, 20.48MHz
|
Original
|
PDF
|
C2260
20MHz,
48MHz
D-74924
32-MHz
VECTRON INTERNATIONAL PART MARKING
|
B287
Abstract: B106 B507 C2530 D106 D206 D287 D807 D206 PIN
Text: TCXO C2530 Typical Applications Features PCS Base Stations Land Mobile Radio Cellular Telephony Radio in the Local Loop Wide Frequency range EFC Standard Standard Surface Mount Package Meets Stratum 3 Previous Corning Model Numbers STO200 Frequency range 30 MHz – 900 MHz
|
Original
|
PDF
|
C2530
STO200
D-74924
B287
B106
B507
C2530
D106
D206
D287
D807
D206 PIN
|
|
D206
Abstract: C2530 Vectron TCXO to 70 MHz datasheets STO200 B106 B287 B507 D106 D287 D807
Text: TCXO C2530 Typical Applications Features PCS Base Stations Land Mobile Radio Cellular Telephony Radio in the Local Loop Wide Frequency range EFC Standard Standard Surface Mount Package Meets Stratum 3 Previous Corning Model Numbers STO200 Frequency range 30 MHz – 900 MHz
|
Original
|
PDF
|
C2530
STO200
D-74924
D206
C2530
Vectron TCXO to 70 MHz datasheets
STO200
B106
B287
B507
D106
D287
D807
|
Untitled
Abstract: No abstract text available
Text: TCXO C2260 Typical Applications Features PCS Base Stations Land Mobile Radio Cellular Telephony Radio in the Local Loop EFC Standard Standard Surface Mount Package Small Size Low Profile Frequency range 6.4 MHz – 52 MHz Standard frequencies 12.8; 19.44; 20MHz, 20.48MHz
|
Original
|
PDF
|
C2260
20MHz,
48MHz
D-74924
|
B507
Abstract: c2260 B106 B287 D106 D256 D287 D807 F287 VECTRON INTERNATIONAL PART MARKING
Text: TCXO C2260 Typical Applications Features PCS Base Stations Land Mobile Radio Cellular Telephony Radio in the Local Loop EFC Standard Low Profile Small Size 100 % RoHS compliant Frequency range 6.4 MHz – 52 MHz Standard frequencies 10; 12.8; 19.44; 20MHz, 20.48MHz
|
Original
|
PDF
|
C2260
20MHz,
48MHz
D-74924
B507
c2260
B106
B287
D106
D256
D287
D807
F287
VECTRON INTERNATIONAL PART MARKING
|
D206
Abstract: vectron tcxo 16,384 gr 801 C2560 MC1200 Vectron TCXO 68 MHz 12.8 tcxo B287 D287 D807
Text: TCXO C2560 Typical Applications Features SONET/SDH Synthesizers Optimized for Semtech SONET / SDH Synchronization Sets Stratum 3 Compliant Tight Stability Low Aging Previous Vectron Model Numbers MC1200; TC-210 Frequency Range 10 MHz – 200 MHz Standard Frequencies
|
Original
|
PDF
|
C2560
MC1200;
TC-210
D-74924
D206
vectron tcxo 16,384
gr 801
C2560
MC1200
Vectron TCXO 68 MHz
12.8 tcxo
B287
D287
D807
|
Untitled
Abstract: No abstract text available
Text: TCXO C2260 Typical Applications Features PCS Base Stations Land Mobile Radio Cellular Telephony Radio in the Local Loop EFC Standard Low Profile Small Size 100 % RoHS compliant Frequency range 6.4 MHz – 52 MHz Standard frequencies 10; 12.8; 19.44; 20MHz, 20.48MHz
|
Original
|
PDF
|
C2260
20MHz,
48MHz
D-74924
|
Untitled
Abstract: No abstract text available
Text: TCXO C2260 Typical Applications Features PCS Base Stations Land Mobile Radio Cellular Telephony Radio in the Local Loop EFC Standard Standard Surface Mount Package Small Size Low Profile Frequency range 6.4 MHz – 52 MHz Standard frequencies 12.8; 19.44; 20MHz, 20.48MHz
|
Original
|
PDF
|
C2260
20MHz,
48MHz
D-74924
|
m883
Abstract: vectron tcxo MIL-PRF-55310 crystals 160* Mhz
Text: 930 Series ELECTRICAL CHARACTERISTICS Nominal Frequency TCXO 10 to 75 MHz Input Voltage +5Vdc ± 5% 25 mA max 10 to 75 MHz Range RF Output Output Power +3 dbm minimum Harmonics 20 dbc Subharmonics N/A Spurious 70 dbc Load 50 Temperature Stability including ±10% Load
|
Original
|
PDF
|
10-9/second
m883
vectron tcxo
MIL-PRF-55310
crystals 160* Mhz
|
C2560
Abstract: vectron tcxo 16,384 Vectron TCXO 68 MHz D807 D206 D287 GR-1244-CORE TC-210 B287 f807 SMD
Text: C2560 TCXO Typical Applications Features SONET/SDH Synthesizers Optimized for Semtech SONET / SDH Synchronization Sets Stratum 3 Compliant Tight Stability Low Aging Previous Vectron Model Numbers MC1200; TC-210 Frequency Range 10 MHz – 200 MHz Standard Frequencies
|
Original
|
PDF
|
C2560
MC1200;
TC-210
135se
D-74924
C2560
vectron tcxo 16,384
Vectron TCXO 68 MHz
D807
D206
D287
GR-1244-CORE
TC-210
B287
f807 SMD
|
C2400
Abstract: b507 D206 VDXXXX 2F P marking g175 tcxo 10mhz dbc hcmos B106 D106 F106
Text: TCXO C2400 Typical Applications Features PCS Base Stations Land Mobile Radio Cellular Telephony Radio in the Local Loop EFC Standard Hermetic Wide Frequency Range Previous Vectron Model Numbers TQDILTC; 979; 979W, 959; 959W, TC-400 Frequency Range 10 MHz – 200 MHz
|
Original
|
PDF
|
C2400
TC-400
76MHz;
D-74924
C2400
b507
D206
VDXXXX
2F P marking
g175
tcxo 10mhz dbc hcmos
B106
D106
F106
|
c2260
Abstract: TCXO SMD 8MHZ B106 B287 B507 D106 D256 D287 D807 GR-1244-CORE
Text: TCXO C2260 Typical Applications Features PCS Base Stations Land Mobile Radio Cellular Telephony Radio in the Local Loop EFC Standard Standard Surface Mount Package Small Size Low Profile Frequency range 6.4 MHz – 52 MHz Standard frequencies 12.8; 19.44; 20MHz, 20.48MHz
|
Original
|
PDF
|
C2260
20MHz,
48MHz
D-74924
c2260
TCXO SMD 8MHZ
B106
B287
B507
D106
D256
D287
D807
GR-1244-CORE
|