Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    SPLIT WINDING Search Results

    SPLIT WINDING Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    10135739-005LF Amphenol Communications Solutions OCTIS™ - SPLIT RUBBER GLAND 8MM Visit Amphenol Communications Solutions
    10135739-003LF Amphenol Communications Solutions OCTIS™ - SPLIT RUBBER GLAND 9MM Visit Amphenol Communications Solutions
    10135739-004LF Amphenol Communications Solutions OCTIS™ - SPLIT RUBBER GLAND 6MM Visit Amphenol Communications Solutions
    10135739-002LF Amphenol Communications Solutions OCTIS™ - SPLIT RUBBER GLAND 7MM Visit Amphenol Communications Solutions
    10135739-001LF Amphenol Communications Solutions OCTIS™ - SPLIT RUBBER GLAND 10MM Visit Amphenol Communications Solutions

    SPLIT WINDING Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    F24-500

    Abstract: FS24-250 F56-045 f28-200 F20-600 fs1020 FS24-045 F28-700 F16-070 F20-055
    Text: Triad Magnetics Product Details Triad Transformer Catalog PC MOUNT - SPLIT PACK Description: The Triad Split Pack split bobbin transformer from Triad Magnetics is an extremely versatile tool for PC board applications. Split Pack transformers are concentrically wound


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Data Sheet CTSA024 Split-Core Current Transformer Miniature Split Core Current Transformer The CTSA024 Series of low cost miniature split-core current transformers are designed for fast and easy installation. The split-core design permits non-contact current measurements through


    Original
    PDF CTSA024 CTSA010 CTSA016

    FP-120-50

    Abstract: FS120-02 360Amps FS24-250 triad FS28-200 FP30-200
    Text: 1032-2012:QuarkCatalogTempNew 8/28/12 2:15 PM Page 1032 TEST & MEASUREMENT 11 Low Clearance, Split Bobbin PC Transformers Power Transformers PC Mount: Split Pack , Split Bobbin L H INTERCONNECT L Split Pack™ transformers are nonconcentrically wound — with primaries and secondaries side-by-side. Unlike the secondary


    Original
    PDF

    FS10 TM

    Abstract: F28-700 Transistor FS10 f28-200 F10-110 f10360 FS16-400 TRANSFORMER CT 1A TRANSFORMER CT 2A F12-500
    Text: Class B UL Recognized PC Mount: Split Pack UL File E53148 : D e s c r i p t i o n The Triad Split Pack split bobbin transformer is an extremely versatile tool for PC board applications. Split Pack transformers are nonconcentrically wound - with primaries and secondaries side-by-side. Unlike the


    Original
    PDF E53148 Primar/16 FS10 TM F28-700 Transistor FS10 f28-200 F10-110 f10360 FS16-400 TRANSFORMER CT 1A TRANSFORMER CT 2A F12-500

    Triad F-269U

    Abstract: No abstract text available
    Text: Text Photo Video Catalog Next-Gen UL Class 2/3 PC Mount Split PackTM Transformers Combine Innovative Design With Price-Performance TUV Approved For Applications Worldwide Corona, CA-With its advanced flexible split pack, improved split bobbin design, Class F


    Original
    PDF UL5085 Triad F-269U

    f103600

    Abstract: F48-023 F24-045 f28-200 F20-120 TRANSFORMER CT 1A TRANSFORMER CT 2A F12-090 F16-070 F20-055
    Text: POWER TRANSFORMERS PC MOUNT 80032 rev D DESCRIPTION : The TRIAD Split Pack bobbin transformer from Triad is an extremely versatile tool for PC board applications. Split Pack transformers are nonconcentrically wound - with primaries and secondaries side-by-side. Unlike the secondary-on-top-ofprimary designs of standard PC board transformers, the split bobbin winding and low


    Original
    PDF 115v/230v 50/60Hz. F10-110 FS10-110 F12-090 FS12-090 F16-070 FS16-0 E53148 f103600 F48-023 F24-045 f28-200 F20-120 TRANSFORMER CT 1A TRANSFORMER CT 2A F12-090 F16-070 F20-055

    neutral missing current transformer

    Abstract: Distribution transformer tap transformer mva 10 mva transformer 3 phase transformer 230vac voltage sag detection using rms 1 MVA transformer 100 MVA transformer transformer 2 mva Split System Air Conditioner
    Text: Energy Measurement in Split-Phase Systems Using 78M6612 A Maxim Integrated Products Brand APPLICATION NOTE AN_6612_032 September 2010 Introduction A split-phase electricity distribution system is a 3-wire single-phase distribution system, commonly used in


    Original
    PDF 78M6612 78M6612 neutral missing current transformer Distribution transformer tap transformer mva 10 mva transformer 3 phase transformer 230vac voltage sag detection using rms 1 MVA transformer 100 MVA transformer transformer 2 mva Split System Air Conditioner

    CT020P2A

    Abstract: MAX13430 ft232rl-reel 78M66xx 10-WFDFN VBT1-S5-S5-SMT 154-2442-E 768-1007-1-nd 78M6613-SP-1 sot23-123
    Text: 78M6613 Split-Phase Evaluation Board User Manual December 2011 Rev. 2 UM_6613_069 78M6613 Split-Phase Evaluation Board User Manual UM_6613_069 Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit


    Original
    PDF 78M6613 78M6613, 78M66xx CT020P2A MAX13430 ft232rl-reel 10-WFDFN VBT1-S5-S5-SMT 154-2442-E 768-1007-1-nd 78M6613-SP-1 sot23-123

    TTPC-13

    Abstract: PCT-77 lb1234 c4115 SW-424 ttpc-2 sidewinder TTPC-8 SW-312 SW-528
    Text: 1024-2012:QuarkCatalogTempNew 8/28/12 2:05 PM Page 1024 TEST & MEASUREMENT 11 Telephone Coupling, Low Profile PC and Split Bobbin PC Transformers Low Profile PC Mount Transformers — Low Boy Series Split Bobbin PC Mount Transformers — Side Winder Series


    Original
    PDF MIL-T-27 PCT-33 PCT-78 PCT-27 PCT-77 PCT-76 TTPC-13 TTPC-13 lb1234 c4115 SW-424 ttpc-2 sidewinder TTPC-8 SW-312 SW-528

    SW-520

    Abstract: 928-9012 DSW-620 928-0612 lb1240 928-0121 SW-628 928-0123
    Text: Stancor Telephone Coupling, Low Profile PC and Split Bobbin PC Transformers Visti StancorÕs Website at www.stancor.com Split Bobbin PC Mount Transformers Side Winder Series Telephone Coupling/Impedance Matching Transformers Features c c c c Small and Lightweight, All Items Weigh Under 1 Oz.


    Original
    PDF LB1224 DSW-236 LB1234 DSW-436 LB1240 DSW-536 LB12230 DSW-636 SW-520 928-9012 DSW-620 928-0612 928-0121 SW-628 928-0123

    Untitled

    Abstract: No abstract text available
    Text: EMI Core ESD-FPD Series Split Cores with Metal Clamp for Flat Cables Overview Benefits The KEMET ESD-FPD Series split cores are designed for use on flat cable. The series features a stainless steel clamp and is available in a variety of sizes. Applications


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: EMI Core ESD-FPD-1 Series Split Cores with Plastic Clamp for Flat Cables Overview Benefits The KEMET ESD-FPD-1 Series split cores are designed for use on flat cable. The series features a nylon clamp and is available in a variety of sizes. Applications EMI Cores


    Original
    PDF

    ROHM BP5045

    Abstract: qfn68 CR8349-1000 tyco 12v relay spdt V07E275P 12vdc tyco relay FT232RQ MS 610-CMPTA63 rg1608p RN732BTTD1004B25
    Text: 19-5642; Rev 11/10 A Maxim Integrated Products Brand 78M6612 Split Phase Evaluation Board User Manual November 8, 2010 Rev. 1.0 UM_6612_044 78M6612 Split Phase Evaluation Board User Manual UM_6612_044 Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit


    Original
    PDF 78M6612 78M6612SP-EVM-1 78M6612, ROHM BP5045 qfn68 CR8349-1000 tyco 12v relay spdt V07E275P 12vdc tyco relay FT232RQ MS 610-CMPTA63 rg1608p RN732BTTD1004B25

    FT232QFN32

    Abstract: ADUM3201ARZ-ND ROHM BP5045 895-FT232RQ QFN-68 CT SENSOR 78M6613 6612S ZNR1 78M6612-68QFP
    Text: 19-5642; Rev 1.1; 5/11 A Maxim Integrated Products Brand 78M6612 Split-Phase Evaluation Board User Manual May 24, 2011 Rev. 1.1 UM_6612_044 78M6612 Split-Phase Evaluation Board User Manual UM_6612_044 Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit


    Original
    PDF 78M6612 78M6612, FT232QFN32 ADUM3201ARZ-ND ROHM BP5045 895-FT232RQ QFN-68 CT SENSOR 78M6613 6612S ZNR1 78M6612-68QFP

    SLVA369

    Abstract: MSD1260 SLVC225 TPS54160 SLVS795 206033 LPD4012 MSD724
    Text: Application Report SLVA369 – October 2009 Creating a Split-Rail Power Supply With a Wide Input Voltage Buck Regulator David G. Daniels . PMP - DC/DC Converters - Swift ABSTRACT


    Original
    PDF SLVA369 SLVA369 MSD1260 SLVC225 TPS54160 SLVS795 206033 LPD4012 MSD724

    60 hz magnetic core

    Abstract: 115v to 230v transformer Lamination transformer from 230V to 5V transformer 230v to 5v split core toroidal transformer transformer 230v TSB-Series TSB-12
    Text: 86 NEW PRODUCT LOW PROFILE SPLIT BOBBIN POWER TRANSFORMER SERIES TSB FEATURES - DIMENSIONS IN INCHES Very low profile design allows low PCB clearance Semi toroidal construction reduces radiated magnetic fields Non concentric winding, lower inter-winding capacitance


    Original
    PDF 200mA 400mA 600mA TSB-12 100mA 60 hz magnetic core 115v to 230v transformer Lamination transformer from 230V to 5V transformer 230v to 5v split core toroidal transformer transformer 230v TSB-Series TSB-12

    T-60144

    Abstract: T-60129 T-60256 60100 T-60148 T-60200 T-60254 T-60223 T-60115 T-60100
    Text: Standard EI PC Power Transformers B Split Bobbin Construction, Non-Concentric Winding Eliminates the need for Electrostatic Sheilding. C G Center Flange Insulation Barrier provides High Insulation and low capacitive coupling, thereby minimizing line noise and false triggering.


    Original
    PDF 115/230V T-60100 T-60101 T-60102 T-60103 T-60104 T-60105 T-60106 T-60144 T-60129 T-60256 60100 T-60148 T-60200 T-60254 T-60223 T-60115 T-60100

    motor winding data

    Abstract: winding Electronic Film Capacitors ADS406A-R03-070108 AVM406A
    Text: AVM406A Automatic Winding Machine for Metallized Film Capacitors MAIN FEATURES • Possibility of winding 2 capacitors each cycle. • Two winding stations independently motor driven. • Split mandrels. • A constant staggering is assured by using air guides.


    Original
    PDF AVM406A ADS406A-R03-070108 motor winding data winding Electronic Film Capacitors ADS406A-R03-070108 AVM406A

    Untitled

    Abstract: No abstract text available
    Text: SAFETY RLD-2240 UL RECOGNIZED E132629 50/60 HZ TRANSFORMERS DUAL/TRAN DESCRIPTION FEATURES & APPLICATIONS • Dual Transformer • Advanced design and manufacturing techniques of using split bobbins and nonconcentric winding of the primary and second ary


    Original
    PDF RLD-2240 E132629 RLD-2240-4-120 RLD-2240-5-120 RLD-2240-6-120 RLD-2240-7-120 RLD-2240-2 RLD-2240-3 RLD-2240-4 RLD-2240-5

    F24-045

    Abstract: No abstract text available
    Text: POWER P C TRANSFORMERS M O U N T S P L I T M P A C K M M M M U DESCRIPTION: The TRIAD Split Pack split bobbin transformer from MagneTek is an extremely versatile tool for PC board applications. Split Pack transformers are nonconcentrically wound - with primaries and secondaries side-by-side. Unlike the


    OCR Scan
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Split Bobbin PC Board Transformers IfH transform er The use of a Split Bobbin allows winding to be nonconcentric side-by-side , consequently high isolation is achieved at low cost. • Eietter insulation — 2500 VRMS hipot is standard. • Lower capacitance — no need for electro-static shield.


    OCR Scan
    PDF IH-120 DH-10 DH-12 DH-16 DH-20 DH-24 DH-32 DH-40 DH-48 DH-80

    Untitled

    Abstract: No abstract text available
    Text: jm Split Bobbin T ransformers U M transformer YOUR PRIMARY SOURCE The use of a Split Bobbin allows winding to be nonconcentric side-by-side , consequently high isolation is achieved at low cost. • Better insulation — 2500 VRMS hipot is standard. • Lower capacitance — no need for electro-static


    OCR Scan
    PDF 30V/115V 15V/230V 50/60HZ 400VA 100VA 600VA 150VA 1000VA 200VA 1500VA

    xl56

    Abstract: No abstract text available
    Text: jm •S Low Profile Split Bobbin PC Board Transformers transform er YOUR PRIMARY SOURCE ^ • Only 1.13" high XL Series transformers offer a particularly low profile for 18VA, allowing for 1.25" card spacing. The: use of a split bobbin allows winding to be nori-concentric side-by-side , consequently high isolation is achieved


    OCR Scan
    PDF 115/230V 44VCT 48VCT 56VCT 72VCT 88VCT 120VCT xl56

    Untitled

    Abstract: No abstract text available
    Text: REV. S t a t u s REVISION REVISED AND REDRAWN ON CAD /CAM 8 / 2 0 / 9 2 TS REVISION A TEMECULA WAS CARSON 0 5 / 2 8 / 9 8 TS TELECOMMUNICATION TRANSFORMER 600 : 600 SPLIT A. Electrical Specifications 25° C 1. Pri Source Impedance; 600 Q 2. Sec Load Impedance; 600 Q SPLIT


    OCR Scan
    PDF 310mH 110mH DC90mA 300Hz,