EPCOS CS 230
Abstract: spark gap CAS02X-067
Text: Switching Spark Gap CAS02X-067 Ordering code: B88069X0670T502 DC spark-over voltage 1 2) 200 . 250 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage
|
Original
|
PDF
|
CAS02X-067
B88069X0670T502
EPCOS CS 230
spark gap
CAS02X-067
|
spark gap
Abstract: EPCOS CS 230 Spark CAS02X-091
Text: Switching Spark Gap CAS02X-091 Ordering code: B88069X0910T502 DC spark-over voltage 1 2) 190 . 220 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage
|
Original
|
PDF
|
CAS02X-091
B88069X0910T502
spark gap
EPCOS CS 230
Spark
CAS02X-091
|
spark gap
Abstract: CAS02X-047
Text: Switching Spark Gap CAS02X-047 Ordering code: B88069X0470T502 DC spark-over voltage 1 2) 215 . 240 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage
|
Original
|
PDF
|
CAS02X-047
B88069X0470T502
spark gap
CAS02X-047
|
spark gap
Abstract: B88069X0680 CAS02X-068 EPCOS CS 230 B88069X0680T502
Text: Switching Spark Gap CAS02X-068 Ordering code: B88069X0680T502 DC spark-over voltage 1 2) 200 . 255 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage
|
Original
|
PDF
|
CAS02X-068
B88069X0680T502
spark gap
B88069X0680
CAS02X-068
EPCOS CS 230
B88069X0680T502
|
EPCOS 230 06 O
Abstract: spark gap CAS02X-069 EPCOS CS 230
Text: Switching Spark Gap CAS02X-069 Ordering code: B88069X0690T502 DC spark-over voltage 1 2) 205 . 230 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage
|
Original
|
PDF
|
CAS02X-069
B88069X0690T502
EPCOS 230 06 O
spark gap
CAS02X-069
EPCOS CS 230
|
EPCOS CS 230
Abstract: spark gap CAS02X-087
Text: Switching Spark Gap CAS02X-087 Ordering code: B88069X0870T502 DC spark-over voltage 1 2) 180 . 230 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage
|
Original
|
PDF
|
CAS02X-087
B88069X0870T502
EPCOS CS 230
spark gap
CAS02X-087
|
ignition spark
Abstract: spark gap cas02xg Spark EPCOS CS 230
Text: Switching Spark Gap CAS02XG Ordering code: B88069X0680T502 DC spark-over voltage 1 2) 200 . 255 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage
|
Original
|
PDF
|
CAS02XG
B88069X0680T502
ignition spark
spark gap
cas02xg
Spark
EPCOS CS 230
|
spark gap
Abstract: CAS02X-093 EPCOS CS 230
Text: Switching Spark Gap CAS02X-093 Ordering code: B88069X0930T502 DC spark-over voltage 1 2) 180 . 220 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time Maximum increase of DC spark-over voltage
|
Original
|
PDF
|
CAS02X-093
B88069X0930T502
spark gap
CAS02X-093
EPCOS CS 230
|
EPCOS 230 03 O
Abstract: spark gap EPCOS CS 230 B88069X4290T502 CAS02X-429
Text: Switching Spark Gap CAS02X-429 Ordering code: B88069X4290T502 DC spark-over voltage 1 2) 235 . 260 V Initial values Ignition time tI after 150 hours in darkness 3) at –20 °C at +25; 125 °C Electrical life time A Maximum increase of DC spark-over voltage
|
Original
|
PDF
|
CAS02X-429
B88069X4290T502
EPCOS 230 03 O
spark gap
EPCOS CS 230
B88069X4290T502
CAS02X-429
|
crank angle position sensors
Abstract: Triggered spark gap cop ignition driver crank positioning sensor motorola transistor ignition spark plugs MPC555
Text: S PA R K A Motorola Low-Level Driver Component Overview The Spark driver, one of the low-level driver components, is designed to generate spark timing output pulses, which are used to charge an ignition coil and ignite a spark plug. The timing of these output pulses is dependent upon engine
|
Original
|
PDF
|
OE-39
crank angle position sensors
Triggered spark gap
cop ignition driver
crank positioning sensor
motorola transistor ignition
spark plugs
MPC555
|
cop ignition driver
Abstract: Triggered spark gap pulse IGNITION Motorola ignition coil driver motorola dis ignition driver spark plugs driver ignition coil motorola transistor ignition spark ignition drivers
Text: S PA R K A Motorola Low-Level Driver Component Overview The Spark driver, one of the low-level driver components, is designed to generate spark timing output pulses, which are used to charge an ignition coil and ignite a spark plug. The timing of these output pulses is
|
Original
|
PDF
|
OE-39
cop ignition driver
Triggered spark gap
pulse IGNITION
Motorola ignition coil driver
motorola dis ignition driver
spark plugs
driver ignition coil
motorola transistor ignition
spark
ignition drivers
|
EPCOS 230 09 O
Abstract: capacitor discharge ignition B88069X0710 EPCOS CS 230 spark gap CAS02X-071 B88069X0710T502
Text: Switching Spark Gap CAS02X-071 Ordering code: B88069X0710T502 DC spark-over voltage 1 2) 215 . 255 V Initial values Ignition time tI after 150 hours in darkness 3) 95 99.9 ≤4 ≤2 at –20 °C at +25; 125 °C Electrical life time A Maximum increase of DC spark-over voltage
|
Original
|
PDF
|
CAS02X-071
B88069X0710T502
EPCOS 230 09 O
capacitor discharge ignition
B88069X0710
EPCOS CS 230
spark gap
CAS02X-071
B88069X0710T502
|
EPCOS CS 230
Abstract: EPCOS 230 01 O spark gap CAS02X-4731 EPCOS 230 01 capacitor 0.1 uF 25 v
Text: Switching Spark Gap CAS02X-4731 Ordering code: B88069X4731T502 DC spark-over voltage 1 2) 190 . 240 V Initial values Ignition time tI after 150 hours in darkness 3) 95 99.9 ≤4 ≤2 at –20 °C at +25; 125 °C Electrical life time A Maximum increase of DC spark-over voltage
|
Original
|
PDF
|
CAS02X-4731
B88069X4731T502
EPCOS CS 230
EPCOS 230 01 O
spark gap
CAS02X-4731
EPCOS 230 01
capacitor 0.1 uF 25 v
|
B88069X
Abstract: SURGE ARRESTER EPCOS 230 07 0 SURGE ARRESTER EPCOS 350 07 0 E163070 diode T87A B88069X FREE SHIPPING On May-14-13 at 01:17:47 PDT, seller added the following information: F health data sheet egypt
Text: EPCOS Product Profile 2015 Surge Arresters and Switching Spark Gaps Überspannungsableiter und Schaltfunkenstrecken www.epcos.com Surge Arresters and Switching Spark Gaps Überspannungsableiter und Schaltfunkenstrecken Contents Inhalt Important notes Wichtige Hinweise
|
Original
|
PDF
|
|
|
igniter transformer
Abstract: xenon hid ballast xenon lamp igniter gas cooker circuit ignitor Ignition Transformer xenon igniter xenon ballast pulse IGNITION Epcos spark gap spark gap ignitor
Text: Switching Spark Gaps Schaltfunkenstrecken Basic circuit pulse igniter Prinzipschaltkreis Impulszündgerät R C General Switching spark gap Schaltfunkenstrecke Load Last RAB0223-W Fig. / Bild 1 General technical information It is increasingly common practice to
|
Original
|
PDF
|
RAB0223-W
igniter transformer
xenon hid ballast
xenon lamp igniter
gas cooker circuit ignitor
Ignition Transformer
xenon igniter
xenon ballast
pulse IGNITION
Epcos spark gap
spark gap ignitor
|
epcos EC 90 11 O
Abstract: EPCOS 470 11 O em epcos 3000 Epcos 5000 11 O epcos EC 90 14 O EPCOS 1400 14 O epcos SURGE ARRESTERS gas discharge epcos 260 11 EPCOS ec 600 10 O EPCOS 350 10 O
Text: Arresters Surge Arresters Switching Spark Gaps Überspannungsableiter Surge Arresters 2-Elektroden-Ableiter 2-electrode surge arresters Nennansprechgleichspannung DC spark-over voltage V Light duty EM M5 EC Medium duty N8 A7 L7 4500 Heavy duty A8 A83 2,5/2,5
|
Original
|
PDF
|
|
EPCOS 230
Abstract: cm 230 spark gap CAM02X Epcos spark gap EPCOS 230 03 O
Text: Switching Spark Gap CAM02X Ordering code: B88069X5410T502 DC spark-over voltage 1 2) 230 ± 15 V % Initial values Ignition time tI after 24 hours in darkness 3) 95 ≤4 ≤2 at –20 °C at +25; 125 °C Electrical life time Switching operations at +25; 125 °C
|
Original
|
PDF
|
CAM02X
B88069X5410T502
EPCOS 230
cm 230
spark gap
CAM02X
Epcos spark gap
EPCOS 230 03 O
|
Untitled
Abstract: No abstract text available
Text: TX Series Triggered Spark Gaps Features • Rugged ceramic-metal construction • Short delay times • Miniature size • High reliability Description The TX is a series of miniature triggered spark gaps designed for high reliability switching with Main Static
|
Original
|
PDF
|
|
MPC55xx
Abstract: AN2864 AN3771
Text: Freescale Semiconductor Application Note Using the eTPU Spark Function by: Bill Terry MSG 32-bit Automotive Applications Engineering USA, Austin 1 Introduction This application note is intended to accompany the simple C interface functions for the eTPU SPARK
|
Original
|
PDF
|
32-bit
MPC55xx
MPC563xM
AN2864--General
AN3768
MPC55xx,
AN2864
AN3771
|
Untitled
Abstract: No abstract text available
Text: BX Series Spark Gaps Description The BX series of miniature two electrode spark gaps 2.0-20.0kV has been designed for applications that have severe environment and high reliability requirements. These gaps are made with high alumina (Al2O3) ceramic cylinders and metal
|
Original
|
PDF
|
|
spark gap switch
Abstract: Triggered spark gap
Text: Mini-Triggered Spark Gaps & Transformers Key Features • • • • • High reliability Extremely low jitter Environmentally durable Small size Matching trigger transformers Applications • • • • Excelitas’ Mini-Triggered Spark Gaps are designed for high reliabilty switching up to 4 kV
|
Original
|
PDF
|
|
AN3771
Abstract: spark AN2864
Text: Freescale Semiconductor Application Note Document Number: AN3771 Rev. 0, 07/2009 Using the eTPU Spark Function by: Bill Terry MSG 32-bit Automotive Applications Engineering USA, Austin 1 Introduction This application note is intended to accompany the simple C interface functions for the eTPU SPARK
|
Original
|
PDF
|
AN3771
32-bit
MPC55xx
MPC563xM
AN2864--General
AN3768
AN3771
spark
AN2864
|
Untitled
Abstract: No abstract text available
Text: 2460 ELECTRONIC SPARK TIMING The ULQ2460A, ULQ2460C, and ULQ2460LW electronic spark timing circuits are intended to interface between conventional electro magnetic pick-ups, a computer-controlled electronic spark timing EST computer, and a high-efficiency ignition coil.
|
OCR Scan
|
PDF
|
ULQ2460A,
ULQ2460C,
ULQ2460LW
PS-014
|
crankshaft position
Abstract: electronic circuit diagram UPS
Text: 2460 E LE C TR O N IC SPARK TIM IN G The ULQ2460A and ULQ 2460LW electronic spark timing circuits are intended to interface between conventional electrom agnetic pick ups, a com puter-controlled electronic spark timing EST computer, and a high-efficiency ignition coil.
|
OCR Scan
|
PDF
|
ULQ2460A
ULQ2460A
2460LW
460A/LW
crankshaft position
electronic circuit diagram UPS
|