PXF-10
Abstract: 24VAC to 24VDC converter PXU-20 input output npn 547 transistor diagram Converter 230v to 24v Transistor z1 Current to voltage Converter 4-20mA to 0-10v 0-30V ac dc converters adjustable 0-30v power supply
Text: Signal Converters & Isolators Process Signal To Frequency Converter PXF-10 DESCRIPTION WIRING DIAGRAM Signal converter for the conversion of an analogue process signal to a pulsating 50% duty cycle transistor output. A typical application would be to convert an analogue signal from a probe to a pulsating
|
Original
|
PXF-10
8/10kHz
40/50Hz
0V/-10-
10VDC/0
EN61010.
IEC414
EN50081-1.
EN50082-2.
IEC68-2-3;
PXF-10
24VAC to 24VDC converter
PXU-20
input output npn 547 transistor
diagram Converter 230v to 24v
Transistor z1
Current to voltage Converter 4-20mA to 0-10v
0-30V
ac dc converters adjustable
0-30v power supply
|
PDF
|
PXU-20
Abstract: PXU-20.924
Text: Signal Converters & Isolators Process Signal Converter PXU-20 r: DESCRIPTION WIRING DIAGRAM Signal converter fo r the conversion of an analogue process signal to another type and /o r to provide galvanic isolation. A typical a pplica tion would be to convert a signal from a probe, not directly com pat
|
OCR Scan
|
PXU-20
VDE0609-1)
75kVAC
UL94V0.
PXU-20
PXU-20.924
|
PDF
|
PXU-20
Abstract: 4-20ma to 0-10v converter Voltage to Current Converter dual 4-20mA 0-10V to 0-20mA converter EN60204-1 "Current to Voltage Converter" 4-20ma Current to voltage Converter 4-20mA to 0-10v 100KOHM
Text: Signal Converters & Isolators Process Signal Converter PXU-20 DESCRIPTION WIRING DIAGRAM Signal converter for the conversion of an analogue process signal to another type and /or to provide galvanic isolation. A typical application would be to convert a signal from a probe, not directly compatible with an analogue input of a PLC and/or provide galvanic isolation
|
Original
|
PXU-20
VDE0609-1)
75kVAC
UL94V1.
UL94V0.
PXF-20
PXU-20
4-20ma to 0-10v converter
Voltage to Current Converter dual 4-20mA
0-10V to 0-20mA converter
EN60204-1
"Current to Voltage Converter" 4-20ma
Current to voltage Converter 4-20mA to 0-10v
100KOHM
|
PDF
|
5v dc relay connection
Abstract: No abstract text available
Text: DATA SHEET D-805 SIVFR SIGNAL ISOLATOR with RUN/FAULT RELAY For all KBVF Models Signal Isolator Provides isolation between non-isolated signal sources and the Drive. Run/Fault Relay Used to turn on or off equipment or signal a warning if a fault occurs. SIVFR Part No. 9597
|
Original
|
D-805
A42098)
5v dc relay connection
|
PDF
|
Untitled
Abstract: No abstract text available
Text: CPT PC-Programmable Temperature Transmitter and Signal Isolator/Converter January 2014 Description The universal CPT PC-Programmable Temperature Transmitter and Signal Isolator/Converter accepts a direct signal input from a wide array of sensors and analog devices:
|
Original
|
0-20mA
|
PDF
|
931S-A2A5N-OP
Abstract: pt100/signal conditioning circuit for pt100 931H-C2C2D-DC 931S-F1C2D-DC E10314 931H-P2A2N-OP 931S-T9C2D-DC 931S-A2A2N-DC pt100 signal conditioner 931S-B1C6D-DC
Text: Bulletin 931 Signal Conditioners Technical Data Bulletin 931 Signal Conditioners Table Of Contents Introduction to Signal Conditioners Page 4 Catalog Number Explanation Page 7 Product Selection • High-Density Signal Conditioners Page 8 • Standard Signal Conditioners
|
Original
|
931-TD001A-EN-P
931S-A3C2D-DC
931S-C3C3J-DC
931U-C9A2C-OP
931U-C9C7C-BC
931S-A2A5N-OP
pt100/signal conditioning circuit for pt100
931H-C2C2D-DC
931S-F1C2D-DC
E10314
931H-P2A2N-OP
931S-T9C2D-DC
931S-A2A2N-DC
pt100 signal conditioner
931S-B1C6D-DC
|
PDF
|
was5
Abstract: 4.20 mA 0-5 ma output 8581160000 8581170000 was5 ccc
Text: Product catalogue | Electronics | Analogue signal conditioning | DC/DC passive isolator | Signal multiplexer General ordering data Order No. Part designation Version EAN Qty. 8581160000 WAS5 CCC 2OLP Signal distributor, 2 x 4.20 mA current loop , Screw connection
|
Original
|
|
PDF
|
GCM232
Abstract: Transformer - 12-0-12, 1 mA VFC20000 OPEN PUSH BUTTON SWITCH 6 pin PRA13021 delta RS-485 gateway driver circuit to drive electromagnetic relay using microprocessor inverse-parallel scr drive circuit 12-0-12 transformer CFC10000
Text: Signal Conversion Isolation Power Supplies Communication Modules DIN-Rail Relays ITMS IRMA ITMA APMR VFC/ CFC IAMS AAMA IAMA Models 191 187 183 181 179 173 169 167 Page Signal Conditioner Signal Conditioner Signal Conditioner 3 Phase Fault Detector Signal Conditioner
|
Original
|
AVMR0037
AVMR4037
GCM232
Transformer - 12-0-12, 1 mA
VFC20000
OPEN PUSH BUTTON SWITCH 6 pin
PRA13021
delta RS-485 gateway
driver circuit to drive electromagnetic relay using microprocessor
inverse-parallel scr drive circuit
12-0-12 transformer
CFC10000
|
PDF
|
was5 ccc
Abstract: 4.20 mA 0-5 ma output 8581170000 8581160000
Text: Product catalogue | Electronics | Analogue signal conditioning | DC/DC passive isolator | Signal multiplexer General ordering data Order No. Part designation Version EAN Qty. 8581170000 WAZ5 CCC 2OLP Signal distributor, 2 x 4.20 mA current loop , Tension clamp connection
|
Original
|
|
PDF
|
relay TB1 225
Abstract: No abstract text available
Text: DATA SHEET D-815 SIAC SIGNAL ISOLATOR For all KBAC Series Inverters Signal Isolator Provides isolation between non-isolated signal sources and the Drive. Isolated +5V Power Supply Used to power a transducer or to supply voltage for potentiometer operation.
|
Original
|
D-815
KBAC-24D
A42108)
relay TB1 225
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Isolated DIN Rail Signal Conditioner DRSL-DC2 U Isolation and Conversion of Process Voltage or Current Signals U Power Supply and Signal Isolator for 2-Wire Transmitter U Slimline Housing— Only 6 mm 0.24" Wide U Multiple Signal Ranges (DIP-Switch Selectable)
|
Original
|
|
PDF
|
SEM-1000
Abstract: SEM1000 ground loop isolator SEM-1200 SEM100 SEM1200 pt100 4-20 ma SEM1500 signal path designer
Text: ISOLATORS HIGH ACCURACY / 0.05% SMALL SIZE / HIGH PACKING DENSITY INPUT AND OUTPUT POWER VERSION VERY LOW COST VERSION SIGNAL SPLITTING VERSION LOOP BOOSTERS FROM A SINGLE SUPPLY PROCESS SIGNAL ISOLATORS SEM1000 Series DESCRIPTION SPECIFICATION @ 20°C The SEM1000 series of loop powered analogue signal
|
Original
|
SEM1000
SE-20
SEM100
SEM101
SEM1100
SEM1401/2
SEM1300
90-240VAC
SEM1500
SEM-1000
ground loop isolator
SEM-1200
SEM100
SEM1200
pt100 4-20 ma
signal path designer
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Analog signal isolator 1-channel IM31-12-I Standard active voltage or current signals are galvanically separated and transferred via the 1-channel analog signal isolator IM31-12-I. The signal is duplicated and provided at both outputs. • Transfer of standard analog signals
|
Original
|
IM31-12-I
IM31-12-I.
2013-07-13T20
D-45472
|
PDF
|
EN50035
Abstract: chopper transformer DSCL21-01 loop powered 4-20ma signal isolator 4-20MA DSCL21-02 0-10v to 4-20ma 4-20ma isolation lexan 940
Text: DSCL21 Loop Powered Isolator DIN Mount FEATURES DESCRIPTION Á NO POWER SUPPLY REQUIRED, SIGNAL POWERED Each DSCL21 loop powered isolator provides a single channel of analog signal protection by electrically isolating its input from output for any DC process signal in the range of 0-20mA
|
Original
|
DSCL21
DSCL21
0-20mA
4-20mA)
DSCL21-01,
EN50035
chopper transformer
DSCL21-01
loop powered 4-20ma signal isolator
4-20MA
DSCL21-02
0-10v to 4-20ma
4-20ma isolation
lexan 940
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Analog signal isolator 1-channel IM31-12EX-I Standard active voltage or current signals are galvanically separated and transferred via the 1-channel analog signal isolator IM31-12EX-I from the Ex area to the non-Ex area. The signal is duplicated and provided at both outputs.
|
Original
|
IM31-12EX-I
2013-07-13T20
D-45472
|
PDF
|
dc chopper circuit
Abstract: chopper transformer 4-20mA circuit 4-20ma isolation 2929 D 92 M 4-20MA DSCL20-01 DSCL20-02 loop powered 4-20ma signal isolator
Text: DSCL20 Loop Powered Isolator "Component Module" FEATURES DESCRIPTION Á NO POWER SUPPLY REQUIRED, SIGNAL POWERED Each DSCL20 loop powered isolator provides a single channel of analog signal protection by electrically isolating its input from output for any DC process signal in the range of 0-20mA
|
Original
|
DSCL20
DSCL20
0-20mA
4-20mA)
DSCL20-02
DSCL20-01
dc chopper circuit
chopper transformer
4-20mA circuit
4-20ma isolation
2929
D 92 M
4-20MA
DSCL20-01
DSCL20-02
loop powered 4-20ma signal isolator
|
PDF
|
NJM2507RB1
Abstract: NJM2504 SW Receiver 20khz NJM2507
Text: NJM2507 VIDEO DIFFERENTIAL INPUT RECEIVER •GENERAL DESCRIPTION The NJM2507 is video differential input receiver. The differential signal is converted to the single-end signal. The single-end signal can be transmitted by the differential signal by the connection with
|
Original
|
NJM2507
NJM2507
NJM2504.
NJM2507.
NJM2507RB1
75ohm
NJM2507RB1
NJM2504
SW Receiver 20khz
|
PDF
|
Untitled
Abstract: No abstract text available
Text: NJM2507 VIDEO DIFFERENTIAL INPUT RECEIVER pGENERAL DESCRIPTION The NJM2507 is video differential input receiver. The differential signal is converted to the single-end signal. The single-end signal can be transmitted by the differential signal by the connection with
|
Original
|
NJM2507
NJM2507
NJM2504.
NJM2507.
NJM2507RB1
75ohm
|
PDF
|
NJM2507
Abstract: No abstract text available
Text: NJM2507 VIDEO DIFFERENTIAL INPUT RECEIVER QGENERAL DESCRIPTION The NJM2507 is video differential input receiver. The differential signal is converted to the single-end signal. The single-end signal can be transmitted by the differential signal by the connection with
|
Original
|
NJM2507
NJM2507
NJM2504.
NJM2507.
NJM2507RB1
75ohm
|
PDF
|
SMBJ15A
Abstract: SMBJ28A
Text: Signal conditioning modules TxxxxP Series FEATURES Active high precision signal conditioning module z Four-terminal isolation signal input, signal output, power supply and output of power supply are mutually isolated z High precision grade (0.1% F.S.) z High linearity (0.1% F.S.)
|
Original
|
5KVDC/60s)
50PPM/Â
30mVp-p
IEC/EN61000
SMBJ15A
SMBJ28A
|
PDF
|
0-10V signal isolator
Abstract: dc chopper circuit 4-20MA DSCL22-01 4-20mA circuit voltage to current 4-20mA 4.20MA 0-10V DSCL22-02 DSCL22-11 EN50022
Text: DSCL22 Loop Powered Isolator DIN or Panel Mount FEATURES DESCRIPTION Á NO POWER SUPPLY REQUIRED, SIGNAL POWERED Each DSCL22 loop powered isolator provides 1, 2, or 3 channels of analog signal protection by electrically isolating its input from output for any DC process signal in the range of 0-20mA
|
Original
|
DSCL22
DSCL22
0-20mA
4-20mA)
DSCL22-01
0-10V signal isolator
dc chopper circuit
4-20MA
DSCL22-01
4-20mA circuit
voltage to current 4-20mA
4.20MA 0-10V
DSCL22-02
DSCL22-11
EN50022
|
PDF
|
RTD PT1000 conversion
Abstract: Signal Converters R2300 R0700 rtd PT10 abb rtd pt100 1SVR 011 755 R2200 1SVR 040 011 R2500 R2700 PT10
Text: 2CDC 285 001 F0005 Analog signal converters CC range The signal converter range for every application 2CDC 115 002 B0x04.pmd 1 1.3.2006, 10:25 The universal signal converters – multifunctional, flexible and precise T he product range of universal signal converters CC-U is
|
Original
|
F0005
B0x04
R0100
R0200
R1300
R1400
B0204
RTD PT1000 conversion
Signal Converters
R2300
R0700
rtd PT10
abb rtd pt100
1SVR 011 755 R2200
1SVR 040 011 R2500
R2700
PT10
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Si86xxIsoLin-UG Si86 XX I S O L I N E A R U SER ’ S G UIDE 1. Introduction The ISOlinear reference design modulates the incoming analog signal, transmits the resulting digital signal through the Si86xx digital isolator, and filters the resulting output-side data to reconstruct the analog input signal. Key
|
Original
|
Si86xxIsoLin-UG
Si86xx
|
PDF
|
namur standard
Abstract: 8581180000 4...20 mA 0-5 converter namur galvanic isolator
Text: Product catalogue | Electronics | Analogue signal conditioning | Frequency signal isolator/converter | f/DC isolating transformer General ordering data Order No. Part designation Version EAN Qty. Input Max. voltage Rated input level Input frequency Sensor
|
Original
|
|
PDF
|