    S2 Switch Normally close

    Abstract: 6A mcb S13-S14
    Text: S2NT030 Safety relays - S2 series Base device for Emergency Stop and Safety Gate applications Equivalent or non-equivalent activation selectable Two-channel activation including cross monitoring and synchronous time check Automatic or Manual Star 3 enabling current paths


    Original
    PDF S2NT030 S13/S14) S23/S24) S14/S35) S2 Switch Normally close 6A mcb S13-S14

    s34 diode

    Abstract: S11-S12
    Text: Emergency Stop and Safety Gate Modules MA1B • • • • • • • • • • Safety Category 2 according to EN 954-1 Category 0 Emergency Stop 2 NO safety outputs 1 NO optocoupled NPN auxiliary outputs 24 VCA / VCC power supply Self monitoring Automatic or manual reset


    Original
    PDF SMS-03 S11S12 S21S22 24Vac S11-S12 S33-S34 s34 diode S11-S12

    MSR126.1T

    Abstract: MSR126T MSR126 440RN23114 440R-N23117 440R-N23120 GuardMaster MSR126R MSR126R msr126.1r 440R-N23114
    Text: Safety Relays Monitoring Safety Relays Minotaur MSR126R/T Specifications Description The Allen-Bradley Guardmaster Minotaur MSR126R/T is a safety monitoring relay that provides the very basics for safety control systems in a 22.5mm package. The MSR126R/T is designed for connection to a single channel


    Original
    PDF MSR126R/T EN954-1, ISO13849-1, EN60204-1, IEC60947-4-1, IEC60947-5-1, AS4024 EN954-1 42/115/230V 50/60Hz MSR126.1T MSR126T MSR126 440RN23114 440R-N23117 440R-N23120 GuardMaster MSR126R MSR126R msr126.1r 440R-N23114

    telemecanique XCS-E

    Abstract: Telemecanique XPS Preventa xps-ac XPSAT5110 XPSAF5130 xpsav11113 XPS-AT3410 telemecanique xps-ak XPS-AC XPSAC5121P
    Text: Machine Safeguarding Products PREVENTA XPS Safety Relays Supplement Catalog 03 File 9007 CONTENTS Description Page Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10 General Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-12


    Original
    PDF 1-888-SquareD 9007CT0203 telemecanique XCS-E Telemecanique XPS Preventa xps-ac XPSAT5110 XPSAF5130 xpsav11113 XPS-AT3410 telemecanique xps-ak XPS-AC XPSAC5121P

    cours electrotechnique

    Abstract: PSR-SCP-24 3-pin power conector IEC 60947-5-1 abb alta velocidad IN234 IEC 60947-5-1 limit switch ex d codeur incremental LED block diagramme abiertos
    Text: PHOENIX CONTACT GmbH & Co. KG D-32823 Blomberg, Germany Fax +49- 0 5235-341200, Phone +49-(0)5235-300 www.interface.phoenixcontact.com MNR 9026297 / 12.2008 DE Drehzahlwächter EN Speed monitor FR Relais tachymétrique IT Modulo di monitoraggio velocità di rotazione


    Original
    PDF D-32823 PSR-SCP-24DC/RSM4/4X1 PSR-SPP-24DC/RSM4/4X1 cours electrotechnique PSR-SCP-24 3-pin power conector IEC 60947-5-1 abb alta velocidad IN234 IEC 60947-5-1 limit switch ex d codeur incremental LED block diagramme abiertos

    6075111009_EN

    Abstract: Bernstein SCR 3-W22-3.6-D
    Text: Technical Data Safety Relay Combination Series SCR SCR 4-W22-3.5-D Description Article number 6075111009 Assembly and function function circuit diagram A1 A2 (+) (-) S33 S34 S11S12 S21 S22 13 23 33 41 14 24 34 42 Electr. Fuse Transformer ~ ~ K1 ~ Monitoring Logic


    Original
    PDF 4-W22-3 S33-S34 S11-S12, S21-S22 D-32457 6075111009_EN Bernstein SCR 3-W22-3.6-D

    lg5925

    Abstract: safemaster lg5925 lg s12 m8552 M2028 121 PTC iec 947.5 iec 60 204-1 M8553 M8582
    Text: Sicherheitstechnik Not-Aus-Modul LG 5925 safemaster 0243284 • • • • • • • • • • • • Funktionsdiagramm nach der EG-Richtlinie für Maschinen 98/37/EG nach IEC/EN 60 204-1, EN 954-1 Sicherheitskategorie 4 nach EN 954-1 Ausgang: max. 4 Schließer, siehe Kontaktbestückung


    Original
    PDF 98/37/EG LG5925 M8581 M8582 D-78114 lg5925 safemaster lg5925 lg s12 m8552 M2028 121 PTC iec 947.5 iec 60 204-1 M8553 M8582

    ossd output

    Abstract: 24v 8 channel Relay driving 24V ac relays S2NG021 DSAE00636 24v relays s34 diode S34-S35 S11-S12 S1232
    Text: S2NG021 Safety relays - S2 series Base device for Emergency Stop and Safety Gate applications Two-channel activation including Cross Monitoring and Synchronous Time Check Automatic or Manual Star Activation via semiconductor output OSSD possible 2 enabling current paths


    Original
    PDF S2NG021 S12-S35) S11/S33 ossd output 24v 8 channel Relay driving 24V ac relays S2NG021 DSAE00636 24v relays s34 diode S34-S35 S11-S12 S1232

    pnoz x5

    Abstract: pilz pnoz x5 PILZ PNOZ cat 3 Pilz safety relay pnoz 19480
    Text: E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ X5 Unit features ` Positive-guided relay outputs: – 2 safety contacts N/O , instantaneous ` Connection options for: – E-STOP pushbutton – Safety gate limit switch – Reset button


    Original
    PDF NSG-D-2-035-2010-08 pnoz x5 pilz pnoz x5 PILZ PNOZ cat 3 Pilz safety relay pnoz 19480

    Pilz safety relay

    Abstract: Pilz PNOZ/X2 PNOZ x2 Pilz PILZ pnoz 10 S11-S12 pnoz 2 NSG-D-2-348-2010-08 IEC 60947-5-1 limit switch KM A1
    Text: E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ X2.2 Unit features ` Positive-guided relay outputs: – 2 safety contacts N/O , instantaneous ` Connection options for: – E-STOP pushbutton – Safety gate limit switch – Reset button


    Original
    PDF NSG-D-2-348-2010-08 Pilz safety relay Pilz PNOZ/X2 PNOZ x2 Pilz PILZ pnoz 10 S11-S12 pnoz 2 NSG-D-2-348-2010-08 IEC 60947-5-1 limit switch KM A1

    PILZ pnoz x3

    Abstract: PILZ PNOZ X3 safety relay pnoz x3 Pilz safety relay pnoz x4 PILZ pnoz x4 PILZ PNOZ X3.10P Pilz safety relay x3 IEC 60947-5-1 limit switch KM A1 Pilz safety relay pnoz x3 s PILZ pnoz s11
    Text: E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ X3.10P Unit features Safety features ` Positive-guided relay outputs: – 3 safety contacts N/O , instantaneous – 1 auxiliary contact (N/C), instantaneous ` 1 semiconductor output ` Connection options for:


    Original
    PDF NSG-D-2-322-2010-01 PILZ pnoz x3 PILZ PNOZ X3 safety relay pnoz x3 Pilz safety relay pnoz x4 PILZ pnoz x4 PILZ PNOZ X3.10P Pilz safety relay x3 IEC 60947-5-1 limit switch KM A1 Pilz safety relay pnoz x3 s PILZ pnoz s11

    xps-ak

    Abstract: schema XPS Ar xpsAK schema led table xps-ak xps ak schema XPS AC K4 24V xps ak safety relay schema led table schema XPS
    Text: XPS-AK Module de surveillance pour circuits d'ARRET D'URGENCE et de sécurité selon EN 418 / EN 60204-1 Safety relay for monitoring EMERGENCY STOP and safety circuits according to EN 418 / EN 60204-1 XPS-AK.P Überwachungsbaustein für NOT-AUS und Sicherheitskreise


    Original
    PDF

    DOLD BH5928

    Abstract: BH5928 bh 5928.92 m8509 K1T1 M7279 M6646 M8080A BI5928 M6651
    Text: Sicherheitstechnik Not-Aus-Modul BH 5928, BI 5928 mit Zeitverzögerung safemaster 0221625 • • • • • • • • • • • BH 5928 Funktionsdiagramm • • Taster Ein Not-Aus Aus nach der EG-Richtlinie für Maschinen 98/37/EG nach IEC/EN 60 204, EN 954-1


    Original
    PDF 98/37/EG BH5928, BI5928 D-78114 DOLD BH5928 BH5928 bh 5928.92 m8509 K1T1 M7279 M6646 M8080A BI5928 M6651

    S33-S34

    Abstract: S11-S12 DIN 50016 S33-S35 DC-13 debouncing relay contact normally closed normally open operation of relay insulation monitoring device S11S12
    Text: S2NGR120 Safety relays - S2 series Base device with settable delay time for Emergency Stop and Safety Gate applications Two-channel activation with Cross Monitoring and Synchronous Time Check Automatic or Manual Star 2 non-delayed enabling current paths stop category 0


    Original
    PDF S2NGR120 S11/S12) S21-S22) S33-S35) S33-S34 S11-S12 DIN 50016 S33-S35 DC-13 debouncing relay contact normally closed normally open operation of relay insulation monitoring device S11S12

    XPS-ASf

    Abstract: XPS-ASF5142 XPS-AS XPS-ASF3442 XPS-Apf xpsasf5142 XPS-ASF3742 Y33-Y34 xps-bc S41-S42
    Text: Components for safety applications Preventa safety modules for emergency stop, limit switch, two-hand control, safety mat and edge monitoring Operating principle, characteristics Operating principle see page 1/12 1 Characteristics Type XPS-ASF Product designed for use in safety


    Original
    PDF S11-S12, S21-S22 S11-B1 S21-S22 S11-S12) S33-S34 S21-S22) Y33/43 XPS-ASf XPS-ASF5142 XPS-AS XPS-ASF3442 XPS-Apf xpsasf5142 XPS-ASF3742 Y33-Y34 xps-bc S41-S42

    Pilz safety relay

    Abstract: pnoz 11 PILZ pnoz PILZ pnoz 11 relay 1210 S33S3 S11-S12 two-hand PILZ PNOZ S11 Safety relay PILZ
    Text: E-STOP relay, safety gate monitor Up to Category 4, EN 954-1 PNOZ 11 Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals PNOZ 11 Unit features Safety features ` Positive-guided relay outputs: – 7 safety contacts N/O , instantaneous


    Original
    PDF NSG-D-2-058-12/04 Pilz safety relay pnoz 11 PILZ pnoz PILZ pnoz 11 relay 1210 S33S3 S11-S12 two-hand PILZ PNOZ S11 Safety relay PILZ

    xps-af

    Abstract: XPS-AF safety 9541A schema XPS schema XPS AC A2S21 xpsaf S11-S12 S1234 W91408385011
    Text: XPS-AF Module de surveillance pour circuits d'ARRET D'URGENCE selon EN 418 / EN 60204-1 Safety relay for monitoring EMERGENCY STOP circuits according to EN 418 / EN 60204-1 Überwachungsbaustein für NOT AUS Kreise gemäß EN 418 / EN 60204-1 99 mm 3.89 in


    Original
    PDF S11/S21 xps-af XPS-AF safety 9541A schema XPS schema XPS AC A2S21 xpsaf S11-S12 S1234 W91408385011

    XPS-afl

    Abstract: S11-S52 xps-af safety circuit relay XPS AL schema XPS transistor S52 xps ak Y1-S37 transistor marking s52 EN61496-1
    Text: XPS-AR FR GB DE Module de surveillance pour circuits d'ARRET D'URGENCE et de sécurité selon EN 418 / EN 60204-1 XPS-AR.P Safety relay for monitoring EMERGENCY STOP and safety circuits according to EN 418 / EN 60204-1 Überwachungsbaustein für NOT AUS und Sicherheitskreise


    Original
    PDF

    777602

    Abstract: pnoz-xv1p PILZ pnoz s11 S11-S12 XV1P Y39-Y40 PILZ PNOZ xv1p
    Text: E-STOP relays, safety gate monitors Up to Category 4, EN 954-1 PNOZ XV1P ` Safety gates ` Light barriers Unit features ` Positive-guided relay outputs: – 2 safety contacts N/O , instantaneous – 1 safety contact (N/O), delay-on de-energisation ` Connection options for:


    Original
    PDF NSG-D-2-308-2007-02 777602 pnoz-xv1p PILZ pnoz s11 S11-S12 XV1P Y39-Y40 PILZ PNOZ xv1p

    24v relays phoenix

    Abstract: DC15V
    Text: PSR-SCP- 24DC/URD3/4X1/2X2/3 PSR-SPP- 24DC/URD3/4X1/2X2/3 Safety Relay as a Contact Extension Block With Off-Delay Contacts INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-.- 24DC/URD3/4X1/2X2/3 safety relay can be used as a contact extension block in safety circuits


    Original
    PDF 24DC/URD3/4X1/2X2/3 24DC/URD3/4X1/2X2/3 60204-1/VDE S33S34 24v relays phoenix DC15V

    Pilz safety relay

    Abstract: pnoz xv3p PILZ pnoz xv3p PILZ pnoz e XV3P pilz xv3p S25000 PILZ pnoz 10 safety monitor S11-S12
    Text: E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ XV3P Unit features ` Positive-guided relay outputs: – 3 safety contacts N/O , instantaneous – 2 safety contacts (N/O), delay-on de-energisation ` Connection options for: – E-STOP pushbutton


    Original
    PDF NSG-D-2-313-2009-09 Pilz safety relay pnoz xv3p PILZ pnoz xv3p PILZ pnoz e XV3P pilz xv3p S25000 PILZ pnoz 10 safety monitor S11-S12

    440R-N23118

    Abstract: 440R-N23119 MSR126T 440R-N23114 sr1-26 440RN23114
    Text: specifications Safety Monitoring Relay Standards IE C 6 0 2 0 4 -I, IS O T R 12100 Safety Category Cat. 4 per E N 9 5 4 -I Approvals C E marked for all applicable directives, BG, and cU L u s except 4 2 V A C units Pow er Supply 24V A C / D C , 42/1 15/230V A C


    OCR Scan
    PDF 15/230V 50/60Hz A/250V A/24V 300ms 100ms MinotaurMSR126440R-N23I16 440R-N23115 440R-N23114 440R-N23113 440R-N23118 440R-N23119 MSR126T sr1-26 440RN23114

    atic 139

    Abstract: No abstract text available
    Text: Safety Monitoring Relay specifications Standards IE C / E N 6 0 2 0 4 -1, IS O T R I2 IO O , IS O 13849-1 E N 954-1 Safety Category Cat. 4 per E N 954-1 Approvals C E marked for all applicable directives P ow er Supply 24V A C / D C , 115 V A C o r 2 30V A C


    OCR Scan
    PDF 50/60Hz MinotaurMSR131RTP A/250V 151230V atic 139

    440R-M23088

    Abstract: 440R-M23147 440R-M 440R-M23092 M23145 440r 440R-M23084 m23088 440R-M23089 440R-M23145
    Text: Safety Monitoring Relay with Delayed Outputs c_ Q_ I C€ MinotaurMSR138DP specifications Standards IEC/EN60204-I, ISOTRI2IOO, ISO 13849-1 EN 954-1 Safety Category Cat. 4 per EN 954-1 Approvals C E marked for all applicable directives Power Supply 24V A C /D C , 115V A C or 230V A C


    OCR Scan
    PDF IEC/EN60204-I, 50/60Hz SRI38DP) AC-15, /250V A/24V 100ms 151230V 440R-M23088 440R-M23147 440R-M 440R-M23092 M23145 440r 440R-M23084 m23088 440R-M23089 440R-M23145