Part | ECAD Model | Manufacturer | Description | Download | Buy |
---|---|---|---|---|---|
LMH2120UMX/NOPB |
![]() |
6 GHz Linear RMS Power Detector with 40 dB Dynamic Range 6-DSBGA -40 to 85 |
![]() |
![]() |
|
LMH2110TMX/NOPB |
![]() |
8 GHz Logarithmic RMS Power Detector With 45 dB Dynamic Range 6-DSBGA -40 to 85 |
![]() |
![]() |
|
LMH2120UM/NOPB |
![]() |
6 GHz Linear RMS Power Detector with 40 dB Dynamic Range 6-DSBGA -40 to 85 |
![]() |
![]() |
|
LMH2110TM/NOPB |
![]() |
8 GHz Logarithmic RMS Power Detector With 45 dB Dynamic Range 6-DSBGA -40 to 85 |
![]() |
![]() |
RMS DETECTOR Datasheets Context Search
Catalog Datasheet | Type | Document Tags | |
---|---|---|---|
Contextual Info: LMH2110 LMH2110 8 GHz Logarithmic RMS Power Detector with 45 dB dynamic range Literature Number: SNWS022B LMH2110 8 GHz Logarithmic RMS Power Detector with 45 dB dynamic range General Description Features The LMH2110 is a 45 dB Logarithmic RMS power detector |
Original |
LMH2110 LMH2110 SNWS022B | |
Contextual Info: HMC1120LP4E v00.0814 POWER DETECTORS - SMT RMS POWER DETECTOR & ENVELOPE TRACKER, DC - 3.9 GHz Typical Applications Features The HMC1120LP4E is ideal for: Broadband Single-Ended RF Input • Log –> Root-Mean-Square RMS Conversion RMS Detector with ±1 dB Detection |
Original |
HMC1120LP4E HMC1120LP4E 150MHz | |
13600D
Abstract: hmc698 HMC700 hmc700lp4 microwave transceiver 13707RZ hmc621 HMC688 Gbps HMC668LP3E
|
Original |
||
RRMS
Abstract: SSM2131
|
OCR Scan |
SSM-2110 100dB SSM-2110 FIGURE11: SSM-2013 SSM-2134 OP-215 AN-116. RRMS SSM2131 | |
Logarithmic Amplifier detector 18GHz
Abstract: LTC5587IDD 04025C102KAT2A AVX LTC5587 2033J LTC5598 04023C103KAT2A 5587 tetra modulation block diagram ofdm modulator
|
Original |
LTC5587 10MHz 12-bit 14GHz 34dBm 12-bit LTC5587 CDMA2000, CDMA2000 850MHz Logarithmic Amplifier detector 18GHz LTC5587IDD 04025C102KAT2A AVX 2033J LTC5598 04023C103KAT2A 5587 tetra modulation block diagram ofdm modulator | |
Contextual Info: LMH2120 LMH2120 6 GHz Linear RMS Power Detector with 40 dB Dynamic Range Literature Number: SNWS021B LMH2120 6 GHz Linear RMS Power Detector with 40 dB Dynamic Range General Description Features The LMH2120 is a 40 dB Linear RMS power detector particularly suited for accurate power measurement of modulated |
Original |
LMH2120 LMH2120 SNWS021B | |
Contextual Info: TRF1600 www.ti.com SPAS094 – FEBRUARY 2010 TRUE RMS RF POWER DETECTOR Check for Samples: TRF1600 FEATURES • • • • • 1 • • • • • RF True RMS Power Detector RMS to DC Conversion Up to 2 GHz Waveform and Modulation Independent CW, GSM, WCDMA, TDMA, HSUPA |
Original |
TRF1600 SPAS094 TRF1600 28-dB | |
LT5581
Abstract: LTC5508 06033A101KAT2A 06033C102KAT2A 06033C103KAT2A 06033C104KAT2A LT5581IDDB LT5560 LT5570 LT5557
|
Original |
LT5581 10MHz 34dBm 14GHz) LT5581 CDMA2000, 2600MHz, 3600MHz, 10dBm 850MHz, LTC5508 06033A101KAT2A 06033C102KAT2A 06033C103KAT2A 06033C104KAT2A LT5581IDDB LT5560 LT5570 LT5557 | |
CATV MODULATOR
Abstract: LT5575 LT5581IDDB LT5570 40A Adjustable Power Supply Schematic Diagram catv DISTRIBUTION NETWORK diagram 06033A101KAT2A 06033C102KAT2A LT5568 06033C104KAT2A
|
Original |
LT5581 10MHz 34dBm 14GHz) LT5581 CDMA2000, 14GHz 2600MHz, 3600MHz, 10dBm CATV MODULATOR LT5575 LT5581IDDB LT5570 40A Adjustable Power Supply Schematic Diagram catv DISTRIBUTION NETWORK diagram 06033A101KAT2A 06033C102KAT2A LT5568 06033C104KAT2A | |
Contextual Info: TRF1600 SPAS094A – FEBRUARY 2010 – REVISED MAY 2011 www.ti.com TRUE RMS RF POWER DETECTOR Check for Samples: TRF1600 FEATURES • • • • • 1 • • • • • RF True RMS Power Detector RMS to DC Conversion Up to 2 GHz Waveform and Modulation Independent |
Original |
TRF1600 SPAS094A TRF1600 28-dB | |
Contextual Info: TRF1600 SPAS094A – FEBRUARY 2010 – REVISED MAY 2011 www.ti.com TRUE RMS RF POWER DETECTOR Check for Samples: TRF1600 FEATURES • • • • • 1 • • • • • RF True RMS Power Detector RMS to DC Conversion Up to 2 GHz Waveform and Modulation Independent |
Original |
TRF1600 SPAS094A TRF1600 28-dB | |
Contextual Info: TRF1600 SPAS094A – FEBRUARY 2010 – REVISED MAY 2011 www.ti.com TRUE RMS RF POWER DETECTOR Check for Samples: TRF1600 FEATURES • • • • • 1 • • • • • RF True RMS Power Detector RMS to DC Conversion Up to 2 GHz Waveform and Modulation Independent |
Original |
TRF1600 SPAS094A | |
Contextual Info: TRF1600 www.ti.com SPAS094 – FEBRUARY 2010 TRUE RMS RF POWER DETECTOR Check for Samples: TRF1600 FEATURES • • • • • 1 • • • • • RF True RMS Power Detector RMS to DC Conversion Up to 2 GHz Waveform and Modulation Independent CW, GSM, WCDMA, TDMA, HSUPA |
Original |
TRF1600 SPAS094 TRF1600 28-dB | |
Contextual Info: TRF1600 SPAS094A – FEBRUARY 2010 – REVISED MAY 2011 www.ti.com TRUE RMS RF POWER DETECTOR Check for Samples: TRF1600 FEATURES • • • • • 1 • • • • • RF True RMS Power Detector RMS to DC Conversion Up to 2 GHz Waveform and Modulation Independent |
Original |
TRF1600 SPAS094A TRF1600 28-dB | |
|
|||
RRUS 01
Abstract: SSM2110P 7107 meters SSM2131 SSM2110 agc amplifier RRUS SSM-2134 18-PIN SSM-2110
|
OCR Scan |
SSM-2110 100dB SSM-2110 liGURE11: SSM-2013 SSM-2134 OP-215 AN-116. RRUS 01 SSM2110P 7107 meters SSM2131 SSM2110 agc amplifier RRUS 18-PIN | |
LTC5587
Abstract: LT5579 LT5568
|
Original |
LTC5587 10MHz 12-bit 14GHz 34dBm 12-bit LTC5587 CDMA2000 850MHz 14GHz LT5579 LT5568 | |
Contextual Info: SpeciÀcation VI13800 Voltage Indicator Electrical Nominal voltage range: 50 - 600V DC/AC rms Nominal voltage threshold indications: 50, 100, 200, 400 V DC/AC rms Voltage threshold tolerance: Conforms to BS EN 61243-3:2010 Polarity & voltage indication: t 12V DC/AC rms |
Original |
VI13800 400Hz 2000m LIT13800 | |
SSM-2013
Abstract: SSM21 ssm2013 ptc rm5 SSM2131 lt 2110 SSM2110
|
OCR Scan |
SSM-2110 100dB F1QURE11 SSM-2110 SSM-2134 OP-215 AN-116. SSM-2013 SSM21 ssm2013 ptc rm5 SSM2131 lt 2110 SSM2110 | |
input buffer amplifier requirementsContextual Info: FEATURES FUNCTIONAL BLOCK DIAGRAM True rms-to-dc conversion 200 mV full scale Laser-trimmed to high accuracy 0.5% maximum error AD636K 1.0% maximum error (AD636J) Wide response capability Computes rms of ac and dc signals 1 MHz, −3 dB bandwidth: V rms > 100 mV |
Original |
AD636K) AD636J) AD636 AD636 O-100] AD636JDZ AD636KDZ AD636JH AD636JHZ input buffer amplifier requirements | |
Contextual Info: Dual PLL Precision Synthesizer AD9578 Data Sheet FEATURES GENERAL DESCRIPTION Any output frequency precision synthesis 11.8 MHz to 919 MHz Better than 0.1 ppb frequency resolution Ultralow rms jitter 12 kHz to 20 MHz <300 fs rms using integer synthesis <405 fs rms using fractional synthesis |
Original |
AD9578 larO-220-WKKD-2 05-10-2012-C 48-Lead CP-48-13) AD9578BCPZ AD9578BCPZ-REEL7 AD9578/PCBZ | |
Contextual Info: Product Brochure/Technical Data Sheet Microwave USB Power Sensors MA24108A, True-RMS, 10 MHz to 8 GHz MA24118A, True-RMS, 10 MHz to 18 GHz MA24126A, True-RMS, 10 MHz to 26 GHz Low Cost, Compact, and Highly Accurate Power Sensors for RF and Microwave Applications |
Original |
MA24108A, MA24118A, MA24126A, MA24108A MA24118A | |
Contextual Info: HMC1021LP4E v02.0511 RMS POWER DETECTOR & ENVELOPE TRACKER, DC - 3.9 GHz Typical Applications Features the HMc1021LP4e is ideal for: Broadband single-ended rF Input • Log –> Root-Mean-Square RMS Conversion • Tx/Rx Signal Strength Indication (TSSI/RSSI) |
Original |
HMC1021LP4E HMC1021LP4E 150MHz | |
high Frequency envelope detector
Abstract: envelope detector
|
Original |
HMC1021LP4E 150MHz HMC1021LP4E high Frequency envelope detector envelope detector | |
Contextual Info: HMC1021LP4E v02.0511 RMS POWER DETECTOR & ENVELOPE TRACKER, DC - 3.9 GHz Typical Applications Features The HMC1021LP4E is ideal for: Broadband Single-Ended RF Input • Log –> Root-Mean-Square RMS Conversion • Tx/Rx Signal Strength Indication (TSSI/RSSI) |
Original |
HMC1021LP4E 150MHz HMC1021LP4E |