Untitled
Abstract: No abstract text available
Text: DRA Series Contactors PART NUMBER NOMENCLATURE DC Motor Reversing Contactors DRA series DC Motor Reversing Contactors utilize Crydom’s advanced solid state DC switching technology to provide an integrated “H Bridge” type DC switching contactor for DC motor reversing applications. These
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Solid State Motor Contactor 3 Phase Motor Reversing Types REC2R AC electronic motor Reversing Relay Instantaneous Switching Three phase with two pole switching Control status LED indication Two control input ranges: 24 VAC/DC, 90-253 VAC Motor rating up to 3kW 3.0 HP
|
Original
|
PDF
|
3RU11
TA25DU-8
3RU1126-1FB0
|
phoenix contact 24v 8 channel Relay board with contact details
Abstract: BOSCH CONNECTOR CATALOG SEB1 5121B015 bosch PTC siemens PTC thermistor relay bosch MA 3.1 0 260 bosch IBS 24 BK IO
Text: IBS IP 500 ELR W-6A DI4/4 Data Sheet INTERBUS Reversing Motor Starter with Integrated Motor Protection Relay Data Sheet Revision C 02/1998 Product Description The reversing motor starter with an integrated motor protection relay switches three-phase asynchronous
|
Original
|
PDF
|
3X32/10AT
5121C
phoenix contact 24v 8 channel Relay board with contact details
BOSCH CONNECTOR CATALOG
SEB1
5121B015
bosch PTC
siemens PTC thermistor relay
bosch MA 3.1
0 260 bosch
IBS 24 BK IO
|
MOTOR control SOFT STARTER reference design schematic
Abstract: phoenix contact 24v 8 channel Relay board with contact details 3 phase motor soft starter diagram 3 phase motor soft starter circuit diagram bosch PTC bosch relay siemens motor starter wiring schematic bosch acceleration sensor 24v dc soft start motor control diagram Siemens Phoenix IEC 60364
Text: IBS IP 500 ELR WS-12A DI4/4 Data Sheet INTERBUS Reversing Motor Starter with Integrated Motor Protection Relay and Soft-Starting Function Data Sheet Revision C 12/1998 Product Description The reversing motor starter with an integrated motor protection relay
|
Original
|
PDF
|
WS-12A
WS-12A
5371C
MOTOR control SOFT STARTER reference design schematic
phoenix contact 24v 8 channel Relay board with contact details
3 phase motor soft starter diagram
3 phase motor soft starter circuit diagram
bosch PTC
bosch relay
siemens motor starter wiring schematic
bosch acceleration sensor
24v dc soft start motor control diagram Siemens
Phoenix IEC 60364
|
LC1-DT40
Abstract: LC1D80004 LADN10 Schneider LC1DT20 LC1-D65 LADS2 LC1-D38 WIRING LC1-D09 lad-s2 LC1-D80004
Text: References TeSys contactors Component parts for assembling reversing contactors for motor control or low speed - high speed starters For 3-pole motor reversing contactors using 2 identical contactors 810373 Contactors with screw clamp terminals or connectors
|
Original
|
PDF
|
LC1-D09.
LA9-D6569
LA9-D4002
LA9-D8069
LA9-D8002
LA9-D92
LA9-D93
LC1-DT40
LC1D80004
LADN10
Schneider LC1DT20
LC1-D65
LADS2
LC1-D38
WIRING LC1-D09
lad-s2
LC1-D80004
|
Untitled
Abstract: No abstract text available
Text: IBS IP 400 ME-ELR R-3A DI4F Module Electronics for an Electronic Reversing-Load Motor Starter With Electronic Motor Protection Data Sheet 6008AC01 09/2000 Product Description Application The reversing-load motor starter with electronic motor protection switches three-phase
|
Original
|
PDF
|
6008AC01
|
6013B
Abstract: universal motor braking IBS IP 400 ME-ELR R-3A DI4
Text: IBS IP 400 ME-ELR R-3A DI4 Module Electronics for a Reversing-Load Motor Starter With Electronic Motor Protection Data Sheet 6013BC01 09/2000 Product Description Application The reversing-load motor starter with electronic motor protection switches three-phase
|
Original
|
PDF
|
6013BC01
HVO/M12
6013B
universal motor braking
IBS IP 400 ME-ELR R-3A DI4
|
6010B
Abstract: No abstract text available
Text: IBS IP 400 ME-MLR R-8A DI4F Module Electronics of an Electromechanical Reversing-Load Motor Starter With Electronic Motor Protection Data Sheet 6010B January 2002 Product Description Application The reversing-load motor starter with electronic motor protection switches three-phase asynchronous motors via the INTERBUS network.
|
Original
|
PDF
|
6010B
6010B
|
Untitled
Abstract: No abstract text available
Text: Introducing the 645RT Solid State Relay The Next Generation of Motor Reversing Contactors The 645RT SSR Series is designed as the replacement for our very successful 275 Motor Reversing Series Relay. The 645RT Series of solid state relay uses triacs for reversing phases on three phase loads. The most typical application use is motor
|
Original
|
PDF
|
645RT
480VAC.
4000Vrms
to100
4-32VDC
480VAC
|
1 HP SINGLE PHASE induction motor wiring diagram
Abstract: RR2A40HA150 AC53a 2.2 kW motors TRS20R20A RR2A48D550 RR2A40HA400 RR2A48D220 RR2A48LA550 ha 80 Ferraz
Text: Motor Controllers Industrial, 2-Phase Motor Reversing Type RR2A • Motor reversing for 3-phase induction motors up to 5.5 kW • Rated operational voltage: Up to 480 VACrms • Built-in interlock function • DC or AC control voltage • Built-in voltage transient protection
|
Original
|
PDF
|
|
single phase electronic motor starter
Abstract: No abstract text available
Text: IBS IP 400 ME-ELR R-3A FO Module Electronics of an Electronic Reversing-Load Motor Starter With Fiber Optic Connection Data Sheet 6550A 11/2002 Product Description Application The reversing-load motor starter with electronic motor monitoring switches three-phase
|
Original
|
PDF
|
HVO/M12
TNR90
single phase electronic motor starter
|
1 HP SINGLE PHASE induction motor wiring diagram
Abstract: AC53a RR2A40D150 RR2A48D550 RR2A48D220 5,5 KW asynchronous HP-550 Ferraz Shawmut 4A 14 x 51 mm 5.5KW induction motor TRS20R20A
Text: Motor Controllers Industrial, 2-Phase Motor Reversing Type RR2A • Motor reversing for 3-phase induction motors up to 5.5 kW • Rated operational voltage: Up to 480 VACrms • Built-in interlock function • DC control voltage • Built-in voltage transient protection
|
Original
|
PDF
|
|
ferraz protistor
Abstract: ferraz protistor 6.621 cp urgb 14 25 optocoupler 621 Protistor FORWARD REVERSE 3 PHASE MOTOR wiring diagram K 4005 AC51 KW ac motor 6.621 URGB 6621CPURGB
Text: Motor Controllers Industrial, 2-Phase IO Reversing Types RR2 I . HAP, RR2 I . LAP, RR2 I . HDP • Motor reversing Solid State Relays for 3-phase induction motors up to 3 kW • Rated operational voltage: Up to 480 VACrms • Built-in interlock function
|
Original
|
PDF
|
same2005)
ferraz protistor
ferraz protistor 6.621 cp urgb 14 25
optocoupler 621
Protistor
FORWARD REVERSE 3 PHASE MOTOR wiring diagram
K 4005
AC51
KW ac motor
6.621 URGB
6621CPURGB
|
PLUGGING BRAKING DIAGRAM
Abstract: IBS IP 400 ELR 2-3A thermostatic switch tree phase motor control DIP switch 8-POS 2L12L22L3 LD4A
Text: PB IP 400 ME-ELR R-3A Module Electronics of an Electronic Reversing-Load Motor Starter With PROFIBUS-DP Connection Data Sheet 6558A 12/2002 Product Description The reversing-load motor starter with electronic motor monitoring switches three-phase asynchronous motors via PROFIBUS-DP.
|
Original
|
PDF
|
HVO/M12
PLUGGING BRAKING DIAGRAM
IBS IP 400 ELR 2-3A
thermostatic switch
tree phase motor control
DIP switch 8-POS
2L12L22L3
LD4A
|
|
Untitled
Abstract: No abstract text available
Text: THE GLOBAL EXPERT IN SOLID STATE RELAY TECHNOLOGY 3 Phase AC Contactors AC Motor Reversing Contactors DC Motor Reversing Contactors DRA Series Contactors ABOUT US DRA SERIES CONTACTORS Crydom, a brand of Custom Sensors & Technologies CST and global DIN Rail Mounted Solid State Contactors
|
Original
|
PDF
|
|
DRA Series Contactors
Abstract: No abstract text available
Text: THE GLOBAL EXPERT IN SOLID STATE RELAY TECHNOLOGY 3 Phase AC Contactors AC Motor Reversing Contactors DC Motor Reversing Contactors DRA Series Contactors ABOUT US DRA SERIES CONTACTORS Crydom, a brand of Custom Sensors & Technologies CST and global DIN Rail Mounted Solid State Contactors
|
Original
|
PDF
|
|
100A TRIAC
Abstract: No abstract text available
Text: 645RT Series - Solid State Reversing 10 - 40 Amp $ E52197 The 645RT series of solid state relays uses triacs for reversing phases on three phase loads. The 64 most typical use is motor reversing. Inputs are DC operated. Load currents can range from 10 to 40
|
Original
|
PDF
|
645RT
E52197
480VAC.
440VAC
4-32VDC
480VAC
100A TRIAC
|
three phase triac
Abstract: No abstract text available
Text: 645RT Series - Solid State Reversing 10 - 40 Amp $ E52197 The 645RT series of solid state relays uses triacs for reversing phases on three phase loads. The 64 most typical use is motor reversing. Inputs are DC operated. Load currents can range from 10 to 40
|
Original
|
PDF
|
645RT
E52197
480VAC.
440VAC
4-32VDC
480VAC
three phase triac
|
E52197
Abstract: 480VAC
Text: 645RT Series - Solid State Reversing 10 - 40 Amp $ E52197 The 645RT series of solid state relays uses triacs for reversing phases on three phase loads. The 64 most typical use is motor reversing. Inputs are DC operated. Load currents can range from 10 to 40
|
Original
|
PDF
|
645RT
E52197
480VAC.
32VDC
480VAC
4-32VDC
E52197
|
IEC 60439-1
Abstract: IP657 schneider thermal overload relay LE2D09V7 schneider motor starter electric motor starter 3 Kw ac motor control
Text: Product data sheet Characteristics LE2D09V7 enclosed DOL reversing starter - TeSys LE2-D - 9 A - coil 400 V AC Range of product TeSys Device short name LE2D Product or component type Enclosed DOL starter Motor starter type Reversing Motor power kW 4 kW at 380/400 V AC 50/60 Hz
|
Original
|
PDF
|
LE2D09V7
IP657
IEC 60439-1
schneider thermal overload relay
LE2D09V7
schneider motor starter
electric motor starter
3 Kw ac motor control
|
LC1 D09 10
Abstract: LC1D40A tesys d contactors LC1 D12 P7 D65A LC1 D09 BD LC2-D12 LC1-D40A LC1 D38 LC2-D09
Text: TeSys contactors References 526172 TeSys D, 3-pole reversing contactors for motor control up to 75 kW at 400 V, in category AC-3 Horizontally mounted, pre-assembled 3-pole reversing contactors for connection by screw clamp terminals Pre-wired power connections.
|
Original
|
PDF
|
D12pp
kW/400
24503-EN
LC1 D09 10
LC1D40A
tesys d contactors
LC1 D12 P7
D65A
LC1 D09 BD
LC2-D12
LC1-D40A
LC1 D38
LC2-D09
|
LC2 contactor
Abstract: LC2-D12 LC2-D09 contactor d09 pp d115 D09P7V D115 D150 LC2-D40 LC2-D150
Text: References TeSys contactors 5 5 Reversing contactors for motor control up to 75 kW at 400 V, in category AC-3 Horizontally mounted, pre-assembled Control circuit: a.c., d.c. or low consumption 810369 3-pole reversing contactors for connection by screw clamp terminals or connectors
|
Original
|
PDF
|
24503-EN
LC2 contactor
LC2-D12
LC2-D09
contactor d09
pp d115
D09P7V
D115
D150
LC2-D40
LC2-D150
|
three phase triac
Abstract: POLARITY REVERSING RELAY 100A250A
Text: Introducing the 645R T Solid State Relay The Next Generation of Motor Reversing Contactors The 645RT SSR Series is designed as the replacement for our very successful 275 Motor Reversing Series Relay. The 645RT Series of solid state relay uses triacs for reversing phases on three phase loads. The most typical application use is motor
|
OCR Scan
|
PDF
|
645RT
480VAC.
4000Vrms
to100
480VAC
C------------------------24,
90-280VAC
4-32VDC
three phase triac
POLARITY REVERSING RELAY
100A250A
|
dc shunt motor starting reversing
Abstract: 2602S24 potentiometer 4k7 2602S12 2602B12 12v DC MOTOR SPEED CONTROLLER dc motor soft start motor forward reverse 24v 2602B24
Text: 2602 Reversing PWM Motor Speed Controller For low voltage dc motors Available for 12 & 24 volt applications 2602S12 Skeleton 2602S24 Skeleton 2602B12 Boxed 2602B24 Boxed Features: Suitable for PM and Shunt motors Reversing Soft Start 0 - 100% Speed Control
|
OCR Scan
|
PDF
|
2602S12
2602S24
2602B12
2602B24
0-12Vdc
0-24Vdc
dc shunt motor starting reversing
potentiometer 4k7
12v DC MOTOR SPEED CONTROLLER
dc motor soft start
motor forward reverse 24v
|