PANDUIT DIE P87 Search Results
PANDUIT DIE P87 Result Highlights (5)
Part | ECAD Model | Manufacturer | Description | Download | Buy |
---|---|---|---|---|---|
TLC555TDF1 |
![]() |
DIE LinCMOS Timer 0- |
![]() |
||
TLC555TDF2 |
![]() |
DIE LinCMOS Timer 0- |
![]() |
||
MSP430F5510CY |
![]() |
16-BIT, FLASH, 25MHz, RISC MICROCONTROLLER, UUC, GREEN, DIE |
![]() |
||
UC1825VTD1 |
![]() |
High-Speed PWM Controller, UC1825-DIE 0- |
![]() |
||
UC1843AVTD1 |
![]() |
Current-Mode PWM Controller, UC1843A-DIE 0- |
![]() |
PANDUIT DIE P87 Datasheets Context Search
Catalog Datasheet | Type | Document Tags | |
---|---|---|---|
Contextual Info: THIS COPY IS PROVIDED ON A RESTRICTED BASIS AND IS NOT TO BE USED IN ANY WAY DETRIMENTAL TO THE INTERESTS OF PANDUIT CORP. ALL DIMENSIONS ARE IN mm Panduit Die Class 2R Wire Strip Current Index No. for l ±2.76 Wire Size Length Rating Class 2R Wire 2 16.50 |
Original |
SCMS10-C SCMS16-C SCMS25-L SCMS35-L SCMS50-L SCMS70-L SCMS95-Q SCMS120-Q SCMS150-X SCMS185-X | |
LCA2-14-Q
Abstract: LCA10-10-L LCA400-12-6 burndy crimping tool
|
Original |
B1-56-X LCA300-38-X LCA300-12-X LCA300-58-X LCA300-78-X LCA350-38-X LCA350-12-X LCA350-58-X LCA350-78-X LCA400-38-6 LCA2-14-Q LCA10-10-L LCA400-12-6 burndy crimping tool | |
LCD10
Abstract: LCD1-56C-E LCD6-10B-L LCD6-14A-L
|
Original |
LCD4/0-12-X LCD250-38D-X LCD250-12-X LCD300-38D-X LCD300-12-X LCD350-14B-X LCD350-38D-X LCD350-12E-X LCD350-12-X LCD400-38D-6 LCD10 LCD1-56C-E LCD6-10B-L LCD6-14A-L | |
Contextual Info: ELECTRICAL SOLUTIONS A. System Overview Code Conductor, Short Blank Tongue, Standard Barrel with Window Lug For Use with Stranded Copper Conductors B1. Cable Ties Type LCA-00 • Color-coded barrels marked with Panduit and specified competitor die index numbers for proper crimp die selection |
Original |
LCA-00 | |
LCD4-10AF-LContextual Info: ELECTRICAL SOLUTIONS A. System Overview Code Conductor, Two-Hole, Standard Barrel with Window Lug, 90° Angle For Use with Stranded Copper Conductors B1. Cable Ties Type LCD-F • Color-coded barrels marked with Panduit and specified competitor die index numbers for proper crimp die selection |
Original |
LCD4/0-38DF-X LCD4/0-12F-X LCD250-38DF-X LCD250-12F-X LCD300-38DF-X LCD300-12F-X LCD350-14BF-X LCD350-38DF-X LCD350-12EF-X LCD350-12F-X LCD4-10AF-L | |
500kcmil
Abstract: LCA6-10F-L P87 103 LCA8-56F-L AWG38 58FX
|
Original |
LCA250-12F-X LCA300-56F-X LCA300-38F-X LCA300-12F-X LCA300-58F-X LCA300-78F-X LCA350-38F-X LCA350-12F-X LCA350-58F-X LCA350-78F-X 500kcmil LCA6-10F-L P87 103 LCA8-56F-L AWG38 58FX | |
burndy 8Contextual Info: ELECTRICAL SOLUTIONS A. System Overview Code Conductor, One-Hole, Standard Barrel with Window Lug, 45° Angle For Use with Stranded Copper Conductors B1. Cable Ties Type LCA-H • Color-coded barrels marked with Panduit and specified competitor die index numbers for proper crimp die selection |
Original |
LCA250-12H-X LCA300-56H-X LCA300-38H-X LCA300-12H-X LCA300-58H-X LCA300-78H-X LCA350-38H-X LCA350-12H-X LCA350-58H-X LCA350-78H-X burndy 8 | |
LCD400
Abstract: LCD4/0-00-X
|
Original |
LCD3/0-12H-X LCD4/0-14BH-X LCD4/0-38DH-X LCD4/0-12H-X LCD250-38DH-X LCD250-12H-X LCD300-38DH-X LCD300-12H-X LCD350-14BH-X LCD350-38DH-X LCD400 LCD4/0-00-X | |
Contextual Info: 450 STR/FLEX Stranded Copper: Class G, H, I, K, M, Locomotive 2-3/4 in. 1/2 in. Yes, for applications up to 35kv. Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 volts. 90 C Yes BROWN P87 20 Wire Size |
Original |
LCCXN450-12 LCCXN450-12-6 LCCXN450-12-CUST | |
486A-486B
Abstract: Panduit dies CT-2931 Panduit physical infrastructure systems LCMD25-00-Q CT-600 panduit CT-600 T 955 200-12 panduit
|
Original |
630mm2 PCCB09 WW-PCCB09 486A-486B Panduit dies CT-2931 Panduit physical infrastructure systems LCMD25-00-Q CT-600 panduit CT-600 T 955 200-12 panduit | |
panduitContextual Info: Terminals PANDUIT Termination Solutions Success Depends on the Crimp. A proper crimp is the key element of an overall wire termination assembly that unfortunately is all too often overlooked. Proper terminal selection, application and crimping are critical factors to |
Original |
SA-ELCB03 SA-NCCB34 panduit | |
SA-NCCB51
Abstract: "Power over Ethernet"
|
Original |
J-STD-607-A ba0-38DW-6 LCC750-12W-6 LCC750-38DW-6 SA-NCCB51 "Power over Ethernet" | |
Contextual Info: ELECTRICAL SOLUTIONS A. System Overview Code Conductor, Two-Hole, Long Barrel with Window Lug, 90° Angle For Use with Stranded Copper Conductors B1. Cable Ties Type LCC-WF • Long barrel maximizes number of crimps and provides premium wire pull-out strength and electrical performance |
Original |
LCCN750-38DW-6 LCCN750-12W-6 | |
L9924
Abstract: LCCX2-14AF-E Burndy 19 burndy GROUNDING CONNECTORS
|
Original |
||
|
|||
D362
Abstract: 1/Nec d362
|
Original |
LCB400-78F-6 LCB500-12F-6 LCB500-58F-6 LCB500-78F-6 LCB600-12F-6 LCB600-58F-6 D362 1/Nec d362 | |
STR 456Contextual Info: ELECTRICAL SOLUTIONS A. System Overview B1. Cable Ties B2. Cable Accessories B3. Stainless Steel Ties Code Conductor, One-Hole, Long Barrel Lug, 45° Angle For Use with Stranded Copper Conductors Type LCB-H • Long barrel maximizes number of crimps and provides premium |
Original |
LCB400-58H-6 LCB400-78H-6 LCB500-12H-6 LCB500-58H-6 LCB500-78H-6 LCB600-12H-6 LCB600-58H-6 STR 456 | |
burndy Y35
Abstract: TBM151 TBM14 Y750HS BPLT14BSCR 13642M BAT35 TBM-14M TBM20S burndy bat750
|
Original |
CT-920, CT-920CH, CT-930, CT-930LPCH, CT-2920, CT-2930, CT-2931, CT-940CH, CT-2940 CD-920-8 burndy Y35 TBM151 TBM14 Y750HS BPLT14BSCR 13642M BAT35 TBM-14M TBM20S burndy bat750 | |
Burndy tool
Abstract: LCAN350-38-X LCAN500-38-6 LCAN400-38-6 D361 LCAN350-12-X LCAN2-14-Q D358
|
Original |
LCAN300-14-X LCAN300-38-X LCAN350-38-X LCAN350-12-X LCAN400-38-6 LCAN400-12-6 LCAN500-38-6 LCAN500-12-6 LCAN600-38-6 LCAN600-12-6 Burndy tool LCAN500-38-6 D361 LCAN350-12-X LCAN2-14-Q D358 | |
CT-2930
Abstract: J-STD-607-A
|
Original |
J-STD-607-A LCCX500-38D-6 LCCX650-12-6 SA-NCCB51 CT-2930 | |
Burndy lphY46
Abstract: STR 20012 burndy Y35 crimping tool manual Burndy Y46 PARTS
|
Original |
CT-2001 CD-2001-6 SCSSTCT250-250 CD-930H-250 CD-920H CD-930H CT-940CH CT-2940 Burndy lphY46 STR 20012 burndy Y35 crimping tool manual Burndy Y46 PARTS | |
SAE-20Contextual Info: CT-720 Compression Connector Installation Tool Maintenance & Inspection Sheet Maintenance and Inspection procedures should be performed at least once a month, whenever damage has occurred, or as often as operating conditions warrant. VISUAL INSPECTION 1. Visually inspect tool for missing or loose pins |
Original |
CT-720 CD-720-1 CD-720-3 CD-720-4 SAE20 CD-720-5 CD-720-6 CD-720-7 CD-720PV8-2 PA22182A01 SAE-20 | |
LCB600-12-6
Abstract: burndy connectors LCB1-12-E
|
Original |
T0-58-6 LCB500-78-6 LCB600-12-6 LCB600-58-6 LCB750-58-6 LCB750-78-6 LCB800-58-6 LCB1000-58-3 burndy connectors LCB1-12-E | |
R-63Contextual Info: THIS COPY IS PROVIDED ON A RESTRICTED BASIS AND IS NOT TO BE USED IN ANY WAY DETRIMENTAL TO THE INTERESTS OF PANDUIT CORP. Material High Conductivity Seamless Copper Tube Plating Electro-Tin Wire Size 450 STR/FLEX Wire Type Stranded Copper: Class G, H, I, K, M, |
Original |
LCCX450-12 LCCX450-12-6 LCCX450-12-CUST R-63 | |
Contextual Info: THIS COPY IS PROVIDED ON A RESTRICTED BASIS AND IS NOT TO BE USED IN ANY WAY DETRIMENTAL TO THE INTERESTS OF PANDUIT CORP. Plating Electro-Tin Wire Size 450 STR/FLEX Wire Type Stranded Copper: Class G, H, I, K, M, Locomotive Wire Strip Length 2-3/4 in. Stud Size |
Original |
LCBX450-38F LCBX450-38F-6 LCBX450-38F-CUST |