RADOX POWER CABLE
Abstract: RADOX 125 1.5 MM2 radox 125 current
Text: Railway products Edition 2013 Bridging our technologies Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical interconnectivity components and systems. Our main markets are communication, transport and industry. Under one roof, we combine
|
Original
|
PDF
|
|
RADOX CABLE 125
Abstract: RADOX 125 1.5 MM2 siemens standard bogie RADOX 125 1.5 MM SMA-50-3-55/199 11_SMA-50-3-55/199_NE RADOX CABLE
Text: Railway products Edition 2014 Bridging our technologies Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical interconnectivity components and systems. Our main markets are communication, transport and industry. Under one roof, we combine
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Data sheet Multifunctional three-phase monitoring relays CM-MPS CM-MPS.21 and CM-MPS.41 Characteristics –– Monitoring of three-phase mains for phase sequence can be switched off , phase failure, over- and undervoltage as well as phase unbalance –– TRMS measuring principle
|
Original
|
PDF
|
|
3 phase monitoring relays
Abstract: No abstract text available
Text: Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. Characteristics –– Monitoring of three-phase mains for phase sequence and
|
Original
|
PDF
|
V0012
3 phase monitoring relays
|
Untitled
Abstract: No abstract text available
Text: Data sheet Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages The CM-ESS.1 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of phase loss. Characteristics –– Monitoring of DC and AC voltages 3-600 V
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of phase loss. Characteristics –– Monitoring of DC and AC voltages 3-600 V
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Data sheet Current monitoring relays CM-SRS.2 For single-phase AC/DC currents The CM-SRS.2 is an electronic current monitoring relay that monitors single-phase mains DC or AC for over- and undercurrent from 3 mA to 15 A. Characteristics –– Monitoring of DC and AC currents (3 mA to 15 A)
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: www.martekpower.com MPF 3K0 1I01 DC/AC INVERTER >Description The 3kVA railway application inverter provides 230 VAC power to train passengers. It has an input of 110 VDC and an output of 230 VAC 50Hz. It is fan cooled and complies with railway standards EN 50155 and EN 50121-3-2. Its standard size facilitates its integration
|
Original
|
PDF
|
|
ABB STOTZ-KONTAKT S 211
Abstract: HC-49/ABB STOTZ-KONTAKT S 211
Text: Data sheet Three-phase monitoring relays CM-PVS CM-PVS.31 and CM-PVS.41 The three-phase monitoring relays CM-PVS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage. Characteristics –– Monitoring of three-phase mains for phase sequence
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: IBX15 Series Data Sheet Boost Converters Features 54.9 2.16" 54.9 2.16" • • • • • • • • • • 11.5 0.45" RoHS compliant for all 6 substances Wide input voltage range 8 to 160 VDC Output: 30 to 80 VDC Class III equipment no isolation input/output
|
Original
|
PDF
|
IBX15
02-Dec-2013
|
microcontroller based substation monitoring using
Abstract: microcontroller based overvoltage and under voltage relays microcontroller based overcurrent relay RTXP 24 microcontroller based substation monitoring and c railway DC feeder protection relay 614AA SUBSTATION CONTROL SYSTEM directional static overcurrent relay 2 pc 506
Text: REL 517 Line protection terminal for railway systems 1MRK 506 017-BEN Page 1 Issued August 1998 Changed since July 1998 Data subject to change without notice SE970142 Features • Complete line protection terminal for railway systems • Intended for both catenary- and line
|
Original
|
PDF
|
017-BEN
SE970142)
003-BEN
017-USV
017-REN
014-BEN
034-BEN
S-721
microcontroller based substation monitoring using
microcontroller based overvoltage and under voltage relays
microcontroller based overcurrent relay
RTXP 24
microcontroller based substation monitoring and c
railway DC feeder protection relay
614AA
SUBSTATION CONTROL SYSTEM
directional static overcurrent relay
2 pc 506
|
QwikConnect October 2007
Abstract: No abstract text available
Text: Qwik Connect G L E N A I R OCTOBER 2007 V O L U M E 11 N U M B E R Take The “A” Train! Glenair Has the Connectors, the Cables and the Expertise to Solve Even the Toughest Rail Industry Interconnect Challenges 4 QwikConnect Take the “A” Train: Connectors, Cables and World-Class Interconnect
|
Original
|
PDF
|
|
LWN2880-6
Abstract: No abstract text available
Text: W Series Data Sheet 125, 250 Watt AC-DC and DC-DC DIN-Rail Converters Features • RoHS lead-free-solder and lead-solder-exempted products are available • Rugged 35 mm DIN-rail snap-fit design • Class I equipment • Universal AC-input or DC-input 66 – 150 or 90 – 350 VDC
|
Original
|
PDF
|
overl35-2
S-KSMH48-2
S-KSMH48-2-27-35-2
BCD20020-G
31-Jan-2013
LWN2880-6
|
LWN1740-6EM1
Abstract: LWR1240-6EM1 SOC NT3 LWR1801-6E 501-2132 UL508-listed uhalp chloride systems 48v charger LWR1701-6E HZZ00618
Text: W Series Data Sheet 125, 250 Watt AC-DC and DC-DC DIN-Rail Converters Features • RoHS lead-free-solder and lead-solder-exempted products are available • Rugged 35 mm DIN-rail snap-fit design • Class I equipment • Universal AC-input with single stage conversion AC to
|
Original
|
PDF
|
PCB24-2
S-KSMH48-2
S-KSMH48-2-27-35-2
BCD20020-G
17-Nov-09
LWN1740-6EM1
LWR1240-6EM1
SOC NT3
LWR1801-6E
501-2132
UL508-listed
uhalp
chloride systems 48v charger
LWR1701-6E
HZZ00618
|
|
Technical Data
Abstract: No abstract text available
Text: Level Switch LFFS Special Features Wetted parts in acid-proof, stainless steel and PEEK Compact, food compatible, hygienic design Hygienic connections conform to 3-A standards, FDA demands and EHEDG guidelines Precise switching point without
|
Original
|
PDF
|
EN/2014-08-26
Technical Data
|
model railway signal project
Abstract: EN 61373 Category 1 Class B SOC NT3 battery charger for mobile 3.7 VDC ac-dc converter full wave type schematic diagram schematic diagram ac-dc converter full wave drossel capacitor LWN1801-6 drossel capacitor 16A HZZ00618
Text: W Series Data Sheet 125, 250 Watt AC-DC and DC-DC DIN-Rail Mount Converters Features Rugged 35 mm DIN-rail snap-fit design Class I equipment Single or double-outputs for 24, 36, or 48 V • RoHS lead-solder-exemption compliant • Universal AC-input with single stage conversion
|
Original
|
PDF
|
|
relay railway
Abstract: LWR-1601-6 NF railway standards switch LWN1601-6 48V AC-DC POWER CONVERTERS APPLICATION NOTES powerone 48v rectifier LWN1740-6EM1
Text: W Series Data Sheet 125, 250 Watt AC-DC and DC-DC DIN-Rail Converters Features • RoHS lead-free-solder and lead-solder-exempted products are available • Rugged 35 mm DIN-rail snap-fit design • Class I equipment • Universal AC-input with single stage conversion AC to
|
Original
|
PDF
|
BCD20020-G
relay railway
LWR-1601-6
NF railway standards switch
LWN1601-6
48V AC-DC POWER CONVERTERS APPLICATION NOTES
powerone 48v rectifier
LWN1740-6EM1
|
EN 61373 Category 1 Class B
Abstract: No abstract text available
Text: IMX4 Series Data Sheet 4 Watt DC-DC Converters Features • RoHS lead-free-solder and lead-solder-exempted products are available. • Input voltage ranges up to 121 VDC • 1 or 2 isolated outputs up to 48 V 20 0.8" • Extremely wide input voltage ranges
|
Original
|
PDF
|
BCD20006-G
15-Dec-2011
EN 61373 Category 1 Class B
|
EN 61373 Category 1 Class B
Abstract: 5imx4-05 20IMX4-1515-8 40imx4-05-8 40IMX4-2424-8ZG 20IMX4-1212-8 5IMX4-15-8
Text: IMX4 Series Data Sheet 4 Watt DC-DC Converters Features • RoHS lead-free-solder and lead-solder-exempted products are available. • Input voltage ranges up to 121 VDC • 1 or 2 isolated outputs up to 48 V 20 0.8" • Extremely wide input voltage ranges
|
Original
|
PDF
|
70IMX4
BCD20006-G
06-Jul-2012
EN 61373 Category 1 Class B
5imx4-05
20IMX4-1515-8
40imx4-05-8
40IMX4-2424-8ZG
20IMX4-1212-8
5IMX4-15-8
|
Untitled
Abstract: No abstract text available
Text: IMX4 Series Data Sheet 4 Watt DC-DC Converters Features • RoHS lead-free-solder and lead-solder-exempted products are available. • Input voltage ranges up to 121 VDC • 1 or 2 isolated outputs up to 48 V 20 0.8" • Extremely wide input voltage ranges
|
Original
|
PDF
|
BCD20006-G
06-Jul-2012
|
40IMX4-15-8
Abstract: 40imx4-05-8 40IMX4-1212-8 40IMX4-05 20IMX4-12-8 40IMX4-2424-8 70IMX4-15-8 CI 3060 elsys Transient Voltage Suppressors 340 V 20IMX4-0505-8
Text: IMX4 DC-DC Series Data Sheet 4-Watt DC-DC Converters Features Input voltage ranges up to 121 VDC 1 or 2 outputs up to 48 VDC Up to 2000 VDC I/O electric strength test • RoHS lead solder exemption compliant • Extremely wide input voltage ranges • Rated to Basic isolation
|
Original
|
PDF
|
70IMX4
89/336/EEC
40IMX4-15-8
40imx4-05-8
40IMX4-1212-8
40IMX4-05
20IMX4-12-8
40IMX4-2424-8
70IMX4-15-8
CI 3060 elsys
Transient Voltage Suppressors 340 V
20IMX4-0505-8
|
EN 61373 Category 1 Class B
Abstract: Antenna-10 20IMX4-05-8 40IMX4-05 40IMX4-05-8 40IMX4-15-8 20IMX4-03-8 h-890 diode 70IMX4-12-8
Text: IMX4 DC-DC Series Data Sheet 4-Watt DC-DC Converters Features • RoHS lead-free-solder and lead-solder-exempted products are available. • Input voltage ranges up to 121 VDC • 1 or 2 isolated outputs up to 48 V • Extremely wide input voltage ranges
|
Original
|
PDF
|
89/336/EEC
BCD20006-G
8-Apr-09
EN 61373 Category 1 Class B
Antenna-10
20IMX4-05-8
40IMX4-05
40IMX4-05-8
40IMX4-15-8
20IMX4-03-8
h-890 diode
70IMX4-12-8
|
Untitled
Abstract: No abstract text available
Text: Features ICE Technology* Description ● ● ● ● ● ● ● ● ● ● ● ● Tx Temperature Range without Derating 120°C Maximum Case Temperature -45°C Minimum Temp. EN 50155 Compliant EN 50121-3-2 Compliant CE Marked 24, 48 and 110VDC Input Ranges
|
Original
|
PDF
|
110VDC
RPR50
24VDC
110VDC,
RPR-39
RPR-40
|
Untitled
Abstract: No abstract text available
Text: Features ICE Technology* Description ● ● ● ● ● ● ● ● ● ● ● ● Tx Temperature Range without Derating 120°C Maximum Case Temperature -45°C Minimum Operating Temperature EN 50155 Compliant EN 50121-3-2 Compliant CE Marked 24, 48 and 110VDC Input Ranges
|
Original
|
PDF
|
110VDC
RPR30
24VDC