    PFD2015-103 Coilcraft Inc Dual wound coil, SMT, RoHS, halogen-free Visit Coilcraft Inc
    PFD2015-472 Coilcraft Inc Dual wound coil, SMT, RoHS, halogen-free Visit Coilcraft Inc
    PFD3215-103ME Coilcraft Inc Dual wound coil, SMT, RoHS, halogen-free Visit Coilcraft Inc
    PFD3215-472ME Coilcraft Inc Dual wound coil, SMT, RoHS, halogen-free Visit Coilcraft Inc
    PFD2015-103ME Coilcraft Inc Dual wound coil, SMT, RoHS, halogen-free Visit Coilcraft Inc

    MTE COIL Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    E180243

    Abstract: No abstract text available
    Text: dV/dT Filter Series A 380 - 600 VAC USER MANUAL PART NO. INSTR - 019 REL. 110726 REV. 006 2011 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation dV/dT Filter is designed to reduce dv/dt and peak voltages to motors fed from a wide variety of PWM inverters. The suitability of this filter for a


    Original
    INSTR-019 E180243 PDF

    IEC 158-1 VDE 0660

    Abstract: mte thermal overload relay bs5424 auto relay 12v 100A mte relay IEC 158-1 mte max0 axt1 overload VDE 0660 iec 158-1 axc1
    Text: Issued November 1994 B18433 The MTE range of overload relays, control relays, contactors and accessories A comprehensive range of four and three pole control relays and contactors with associated accessories including overload relays, replacement coils and


    Original
    B18433 BS5424, VDE0660 660Vac 600Vac IEC 158-1 VDE 0660 mte thermal overload relay bs5424 auto relay 12v 100A mte relay IEC 158-1 mte max0 axt1 overload VDE 0660 iec 158-1 axc1 PDF

    IEC 158-1 VDE 0660

    Abstract: IEC 158-1 bs5424 mte relay mte max04 mte thermal overload relay axt1 overload mte max0 660VAC BS5424 IEC 158-1 VDE 0660
    Text: Issued November 1994 018-433 Data Pack B The MTE range of overload relays, control relays, contactors and accessories Data Sheet A comprehensive range of four and three pole control relays and contactors with associated accessories including overload relays, replacement coils and


    Original
    220/240V 24Vdc 415/440V IEC 158-1 VDE 0660 IEC 158-1 bs5424 mte relay mte max04 mte thermal overload relay axt1 overload mte max0 660VAC BS5424 IEC 158-1 VDE 0660 PDF

    IEC 158-1

    Abstract: bs5424 IEC 158-1 VDE 0660 axc1 axc3 mte max0 mte relay BS5424 IEC 158-1 VDE 0660 mte thermal overload relay VDE 0660 iec 158-1
    Text: Issued March 1997 232-4831 Data Pack B The MTE range of overload relays, control relays, contactors and accessories Data Sheet A comprehensive range of four and three pole control relays and contactors with associated accessories including overload relays, replacement coils and


    Original
    220/240V 24Vdc 415/440V IEC 158-1 bs5424 IEC 158-1 VDE 0660 axc1 axc3 mte max0 mte relay BS5424 IEC 158-1 VDE 0660 mte thermal overload relay VDE 0660 iec 158-1 PDF

    MTE Contactor

    Abstract: CAP-348TP CAP-347TP CAP-346TP MAPP0021D MAPP0034C MAPP0786D capacitor 400v wiring diagram contactor 40 amp 3 phase MAPP0128D
    Text: Matrix AP 400V – 690V TECHNICAL REFERENCE MANUAL FORM: MAP-TRM-E REL. October 2014 REV. 018 2014 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. WARNING Quick Reference ❶ Selection Guide


    Original
    CAB-26APD CAB-42AP CAB-48AP MTE Contactor CAP-348TP CAP-347TP CAP-346TP MAPP0021D MAPP0034C MAPP0786D capacitor 400v wiring diagram contactor 40 amp 3 phase MAPP0128D PDF

    MAPP0786D

    Abstract: MAPG0165C MAPP0103E MAPP0021D MAPP0034C MAPP0208C MAPP0165C
    Text: Improve YOUR POWER QUALITY & ENERGY EFFICIENCY…WITH MTE’S PATENTED* Adaptive Passive Technology TO ACHIEVE BETTER THID PERFORMANCE OVER A WIDER LOAD RANGE. *PATENT PENDING Helps meet IEEE-519 Requirements 5% THID when used at lighter loads %THID Percent THID for Series AP (165A)


    Original
    IEEE-519 W13330 MAPP0786D MAPG0165C MAPP0103E MAPP0021D MAPP0034C MAPP0208C MAPP0165C PDF

    wiring diagram slip ring motor resistance starter

    Abstract: 3 phase motor soft starter circuit diagram wiring 3 phase dol starter with emergency stop 37 MTE powersoft 24v dc soft start motor control diagram wiring diagram slip ring motor BS4265 wiring diagram dol motor reversing starter how to install wiring DOL starter important principles of fault finding in thyristor
    Text: Issued July 1999 232-4572 Data Pack B Powersoft MN Series Data Sheet Supplied to RS by MTE Ltd Electronic Motor Controllers 4kW to 37kW RS stock numbers 279-4230, 279-4246, 279-4252, 279-4268 Contents 1. 2. 3. 4. 5. Introduction Technical specification Principles of operation


    Original
    PDF

    tyco 114-25026

    Abstract: 58342-1 6414 tube LR7189 SN60 SN62 408-7424 tube 6922 Alpha 611 RMA msds CRIMPING
    Text: Application Specification 114- 25026 AMPMODU* MTE Interconnection System NOTE i 15 FEB 10 Rev D All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.


    Original
    PDF

    tyco 114-25026

    Abstract: 856002 IPC-S-815 maintenance manual 565435-5 Tyco Electronics Instruction Sheet 408-7424 565435-5 108-25034 AMPMODU .100 crimp 408-7424 Flat Ribbon Connector 2x10 IDC male
    Text: Application Specification 114-25026 AMPMODU* MTE Interconnection System NOTE i 26 NOV 08 Rev C All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .


    Original
    PDF

    axc3

    Abstract: axc4 capacitor duty type contactor contactor coils 415v Ac contactor coils 415v MAX05 240V AC TO 12v DC CIRCUIT DIAGRAM DC 3 DUTY CONTACTOR axc4 coil MAX-03
    Text: Issued November 1991 012-384 Data Pack B Heating and lighting contactors Data Sheet Figure 1 Circuit diagram 240V 50/60Hz 415V supply coil supply L1 L2 L3 N A1 1 3 5 13 * A2 2 4 6 14 Neutral bar E General A range of contactors in ratings up to 100A for switching three phase heating and lighting loads. All contactors have a 240Vac coil and are fitted into an IP55


    Original
    50/60Hz 240Vac MAX03 MAX05 31mperature 660Vac 240Vdc axc3 axc4 capacitor duty type contactor contactor coils 415v Ac contactor coils 415v MAX05 240V AC TO 12v DC CIRCUIT DIAGRAM DC 3 DUTY CONTACTOR axc4 coil MAX-03 PDF

    BS4999

    Abstract: mte overload mte thermal overload relay MTE Entrelec automatic brake failure indicator brake failure indicator CETA164 CETA324 DCPM022 DCPM045
    Text: Technical Specification English } P3 P4 } DCPM heatsink temperature n.c. contact, opening when temperature is high P5 Thyristor fail detect (link to P3 to disable e.g. with old DCPM) P1 P2 Powerbrake DCBUA / DCPM D.C. Injection Brake System Issue 2 Thermistor connections


    Original
    PDF

    III-G AMPOMATOR

    Abstract: AMPOMATOR CLS IV 56787 general maintenance for applicators 114-25038 408-8547 567297-3 567296-3
    Text: Application Specification 114-25038 AMPMODU* Short Point Contacts and Housings NOTE i 26 AUG 08 Rev H All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .


    Original
    PDF

    magnetic Contactor wiring diagrams

    Abstract: PLUGGING BRAKING DIAGRAM PLUGGING OF INDUCTION MOTOR automatic brake failure indicator AC drives regenerative braking circuits mte thermal overload relay contactor wiring diagram with timer brake failure indicator 5.5KW induction motor wiring diagram dol motor starter
    Text: Technical Specification English Issue 2 Powerbrake Terminal functions DCB5A D.C. Injection Brake Unit A1 A2 N.B. The DCB5A is fully interchangeable with the former DCB5. The DCB5 was identified by a light grey enclosure with a black lid. The DCB5A is all light grey.


    Original
    PDF

    B1238

    Abstract: axc3 capacitor duty type contactor 240v 12v transformer 4560d axc1 mte contactor mte axc1
    Text: Issued November 1991 B12384 Heating and lighting contactors Features l Four ratings available, 25A, 45A, 80A and 100A AC1 , all with 240V, 50Hz coils l Suitable for switching heating and lighting loads l 25A and 45A contactors have 4 main poles, 80A and 100A contactors have 3 main poles


    Original
    B12384 660Vac 240Vdc B1238 axc3 capacitor duty type contactor 240v 12v transformer 4560d axc1 mte contactor mte axc1 PDF

    telemecanique contactor catalogue

    Abstract: telemecanique star delta starter bs88 zs levels HRC fuse gg GEC BS88-2 15KW motor telemecanique star delta starter table NIT16 gec mte axto overload BS88 fuse curve hbc
    Text: Issued March 1997 232-3608 Data Pack B Data Sheet BS88 HBC Fuselinks, type T HBC* fuselinks ASTA* certified to BS88: Part 2: 1975, suitable for general purpose industrial applications eg. heating and lighting circuits and for short circuit protection of motor control circuits.


    Original
    IEC269: RS20H RS32H RS63H RS100H telemecanique contactor catalogue telemecanique star delta starter bs88 zs levels HRC fuse gg GEC BS88-2 15KW motor telemecanique star delta starter table NIT16 gec mte axto overload BS88 fuse curve hbc PDF

    telemecanique contactor catalogue

    Abstract: telemecanique star delta starter HRC fuse gg GEC bs88 zs levels mte axto overload NIT16 gec gec switchgear TIA32 mte max0 TIS63M80 curve
    Text: Issued March 1992 012-659 Data Pack B Data Sheet BS88 HBC Fuselinks, type T HBC* fuselinks ASTA* certified to BS88: Part 2: 1975, suitable for general purpose industrial applications eg. heating and lighting circuits and for short circuit protection of motor control circuits.


    Original
    IEC269: RS20H RS32H RS63H RS100H telemecanique contactor catalogue telemecanique star delta starter HRC fuse gg GEC bs88 zs levels mte axto overload NIT16 gec gec switchgear TIA32 mte max0 TIS63M80 curve PDF

    MSDS 22AWG

    Abstract: maintenance manual 565435-5 585401 tyco 108-25034 plastic SN60 SN62 Tyco 408-8059 tube 6922 JO07 312522
    Text: ti/ca/Electronics A p p lica tio n S p e cificatio n AMPMODU*MTE Interconnection System 114-25026 1 3 J U N 00 Rev B A ll numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance o f+ 0 .13 [0 0 5 ] and angles have a tolerance o f ±2°


    OCR Scan
    13JUN00 MSDS 22AWG maintenance manual 565435-5 585401 tyco 108-25034 plastic SN60 SN62 Tyco 408-8059 tube 6922 JO07 312522 PDF

    Overload MTE

    Abstract: mte overload IEC 947-4-1 MAX072
    Text: E-Pack Installation Instructions Starters Type EXS1-D up to 15kW Issue 4 C€ IEC 947-4-1 METAL ENCLOSURE Installation Ratings 1. Remove cover from starter by releasing catches with a screwdriver, i Insert screwdriver into slot to release catch 2. Check operating coil voltage and


    OCR Scan
    15V/3PH 40V/1PH Overload MTE mte overload IEC 947-4-1 MAX072 PDF

    mte thermal overload relay

    Abstract: mte overload recommended star-delta control circuit Overload MTE mte relay MTE Contactor ESSEX ss9 5ls neutral links mte coil fuse/mte thermal overload relay
    Text: ce E-Pack installation Instructions Starters Type EXS2-S and EXS2-SI Issue 1 Installation ie c 947 4-1 - Ratings 1. Remove cover by releasing catches with a screwdriver. Star-Delta 22kW 415V max. Coil voltages 50Hz 240V 415V Recommended Approximate motor rating max. fuse


    OCR Scan
    PDF

    C947

    Abstract: HRC Fuse BASE ESSEX ss9 5ls
    Text: C€ E-Pack Installation Instructions Starters Type EXS2-DI Issue 6 Installation ie c 947 4-1 - Ratings 1. Remove cover from starter by releasing catches with a screwdriver. Direct-On-Line up to 15kW 415V max. 2. Check operating coil voltage and frequency.


    OCR Scan
    PDF

    C947

    Abstract: C-947
    Text: C€ E-Pack Installation Instructions Starters Type EXS2-DR Issue 6 Installation - Ratings 1. Remove cover by releasing catches with a screwdriver. 2. Check operating coil voltage and frequency. 3. Remove appropriate top/bottom conduit knockouts. 4. Mount base on a vertical surface using top


    OCR Scan
    32EXS2-DR C947 C-947 PDF

    ESSEX Contactor

    Abstract: 3 phase, 415v and 37 kw motor mte contactor coil 32EXS0-D mte overload MAX072 Overload MTE mte contactor 3 phase, 415v and 55 kw motor 3 phase, 415v and 12 kw motor
    Text: C€ Installation Instructions Starters Type: EXSO-D Issue 10 Im STB W^fPACK I EC 947-4-1 Ratings Full load current min. max. Approximate motor ratir g 415V/3PH 240V/1PH AC3 AC3 kW hp kW hp Recommended max. fuse size for short circuit protection A O rderreferences


    OCR Scan
    32EXS0-D 15V/3PH 40V/1PH ESSEX Contactor 3 phase, 415v and 37 kw motor mte contactor coil mte overload MAX072 Overload MTE mte contactor 3 phase, 415v and 55 kw motor 3 phase, 415v and 12 kw motor PDF

    ESSEX Contactor

    Abstract: LS 32 CONTACTOR LS Contactor ROTOR STAR 415 AC, 3 phase to 600V dc transformer CETA CETA25-32 120v AC to 12V dc transformer CETA12
    Text: In stallatio n - C E T A C o n tacto r General Data Contactor ratings 3-phase motor switching Contactor types CETA09-16 Max. ops/h 1200 75 a.c. 9 a.c. 100 a.c. 10 a.c. Operating times ms Closing Opening 11 - 22 a.c. 5 - 1 9 a.c. 22 - 29 a.c. 1 0- 15 a.c.


    OCR Scan
    CETA09-16 CETA25-32 CETA09 CETA12 CETA16 CETA25 CETA32 ESSEX Contactor LS 32 CONTACTOR LS Contactor ROTOR STAR 415 AC, 3 phase to 600V dc transformer CETA 120v AC to 12V dc transformer PDF

    ESSEX Contactor

    Abstract: HL25-240D MTE Contactor
    Text: C€ E-Pack Installation Instructions Enclosed Contactors issue 8 Features IEC 947-4-1 Typical Circuit Connections An extensive range of contactors, in ratings up to 200 Am ps, for switching three-phase heating and lighting loads. Available with d.c. coil and rectifier for


    OCR Scan
    1x10m 1x35m HL100 HL180 HL200 ESSEX Contactor HL25-240D MTE Contactor PDF