Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    INTERNATIONAL PROTECTION (IP) RATINGS TO IEC 529 Search Results

    INTERNATIONAL PROTECTION (IP) RATINGS TO IEC 529 Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    PQU650M-F-COVER Murata Manufacturing Co Ltd PQU650M Series - 3x5 Fan Cover Kit, RoHs Medical Visit Murata Manufacturing Co Ltd
    DF3D36FU Toshiba Electronic Devices & Storage Corporation TVS Diode (ESD Protection Diode), Bidirectional, +/-28 V, SOT-323 (USM), 2 protected lines, AEC-Q101 Visit Toshiba Electronic Devices & Storage Corporation
    DF3D18FU Toshiba Electronic Devices & Storage Corporation TVS Diode (ESD Protection Diode), Bidirectional, +/-12 V, SOT-323 (USM), 2 protected lines, AEC-Q101 Visit Toshiba Electronic Devices & Storage Corporation
    DF3D29FU Toshiba Electronic Devices & Storage Corporation TVS Diode (ESD Protection Diode), Bidirectional, +/-24 V, SOT-323 (USM), 2 protected lines, AEC-Q101 Visit Toshiba Electronic Devices & Storage Corporation
    TCKE712BNL Toshiba Electronic Devices & Storage Corporation eFuse IC (electronic Fuse), 4.4 to 13.2 V, 3.65 A, Latch, Adjustable Over Voltage Protection, WSON10 Visit Toshiba Electronic Devices & Storage Corporation

    INTERNATIONAL PROTECTION (IP) RATINGS TO IEC 529 Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    TK 2518

    Abstract: No abstract text available
    Text: Technical Annex CHART I International Protection IP Ratings to IEC 529 Second Digit – Degree of Water Protection Protection Modes to EN 60529 DIN VDE 0470 Part 1 IP X0 IP X1 No Protection Protection against dripping Protection water falling against penetravertically


    Original
    M20/M25 M32/M40 M25/M32 TK 2518 PDF

    DIN VDE 470, DIN EN 60529, IEC 529

    Abstract: ip 66, IEC 529 106010 120-404 121-407 150009 741-402 740402 150002, relay tk 69
    Text: CHART I International Protection IP Ratings to IEC 529 Technical Annex Second Digit – Degree of Water Protection Protection Modes to EN 60529 DIN VDE 0470 Part 1 IP X0 IP X1 No Protection Protection against dripping Protection water falling against penetravertically


    Original
    5-150A 370-122006-5M DIN VDE 470, DIN EN 60529, IEC 529 ip 66, IEC 529 106010 120-404 121-407 150009 741-402 740402 150002, relay tk 69 PDF

    International Protection (IP) Ratings to IEC 529

    Abstract: No abstract text available
    Text: Technical Annex CHART I International Protection IP Ratings to IEC 529 Second Digit – Degree of Water Protection Protection Modes to EN 60529 DIN VDE 0470 Part 1 IP X0 IP X1 No Protection Protection against dripping Protection water falling against penetravertically


    Original
    PDF

    OGD 0031-8231

    Abstract: schurter fuse holder MXT 8211 7170.0430 31-0175 3101.8511 MXT 8211 A FEC 031.1631 LR38456 3101.0120
    Text: Selector Chart For Fuseholders Panel Mount Snap-in NEW Rear mount captive fuse carrier recessed fuse carrier Series / page FPG / 74 FPG / 76 FPG / 77 FBS / 86 Panel mount • • • rear mount • • Solder/quick terminals • • • • • • • •


    Original
    5x20mm OGD 0031-8231 schurter fuse holder MXT 8211 7170.0430 31-0175 3101.8511 MXT 8211 A FEC 031.1631 LR38456 3101.0120 PDF

    EN 50041 IEC 60947-5-1 limit switch

    Abstract: A600 GLCB01C Q300 glz1aa IEC-947-5-1 AC15 B300
    Text: Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog. Use the Interactive Catalog to access the most complete and up-to-date information available.


    Original
    PDF

    MXT 8211 A

    Abstract: MXT 8211 FEC 031.1631 FUSE 3A 125V SMT KEA 10A 250V 3 pole power entry modules E41871 C934 fek 0031 value insulation resistance between main 231014
    Text: Selector Chart For Fuseholders Panel Mount Snap-in NEW NEW Rear mount captive fuse carrier recessed fuse carrier Press fit version Series / page FPG / 74 FPG / 76 FPG / 77 FBS / 86 Panel mount • • • rear mount • • Solder/quick terminals • • •


    Original
    5x20mm E41871) MXT 8211 A MXT 8211 FEC 031.1631 FUSE 3A 125V SMT KEA 10A 250V 3 pole power entry modules E41871 C934 fek 0031 value insulation resistance between main 231014 PDF

    A600

    Abstract: GLCB01C Q300 glz1aa GLZ30 IEC-947-5-1 AC15 B300 EN 50041 IEC 60947-5-1 limit switch
    Text: Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog. Use the Interactive Catalog to access the most complete and up-to-date information available.


    Original
    PDF

    IEC-947-5-1 AC15 B300

    Abstract: EN 50041 IEC 60947-5-1 limit switch A600 GLCB01C Q300 glz1aa EN 50041
    Text: Limit and Enclosed Switches Global Limit Switches GLS Series Limit/Enclosed GENERAL INFORMATION The GLS series is specifically designed for world-wide applications and is supported by Honeywell global resources for sales and after sales service. Over 300 versions designed to the newest


    Original
    EN50041 EN50047 EN50041 IEC-947-5-1 AC15 B300 EN 50041 IEC 60947-5-1 limit switch A600 GLCB01C Q300 glz1aa EN 50041 PDF

    IEC 947 EN60947

    Abstract: EN 50041 IEC 60947-5-1 limit switch GLAB01E7B GLCB01C ICE 947/ EN60947 limit switch cam type GLZ301 IEC 60947-5-1 limit switch ex d EN 50041 A600
    Text: Limit and Enclosed Switches Global Limit Switches GLS Series Limit/Enclosed GENERAL INFORMATION The GLS series is specifically designed for world-wide applications and is supported by Honeywell global resources for sales and after sales service. Over 300 versions designed to the newest


    Original
    EN50041 EN50047 EN50041 IEC 947 EN60947 EN 50041 IEC 60947-5-1 limit switch GLAB01E7B GLCB01C ICE 947/ EN60947 limit switch cam type GLZ301 IEC 60947-5-1 limit switch ex d EN 50041 A600 PDF

    Untitled

    Abstract: No abstract text available
    Text: Standards CE and IEC Classifications CE Applicable European Directives The CE Mark is a European Union EU compliance symbol and acronym for Conformité Européenne. The CE Mark indicates that a product complies with all European directives and essential


    Original
    73/23/EEC Z-196 PDF

    DIN 40050 Part 9 IEC 529

    Abstract: din 46244-A6.3-0.8 din 46244-A6 din IEC 68-2-11 DIN VDE-0660 Part 303 RBS 200 VDE 0660, PART 101 DIN 46244 46244-A6
    Text: Thermal Overcurrent Circuit Breaker 1658-. Description Very cost effective design to meet international requirements. No exposed metal parts which are, or could become, current-carrying except for terminals. ● Manual reset, trip free mechanism ● Extremely small and lightweight


    Original
    730-1/DIN 46244-A6 S83-P10 DIN 40050 Part 9 IEC 529 din 46244-A6.3-0.8 din 46244-A6 din IEC 68-2-11 DIN VDE-0660 Part 303 RBS 200 VDE 0660, PART 101 DIN 46244 PDF

    IEC-664 insulation distances

    Abstract: 106m1 DIN 40050 Part 9 IEC 529 IEC 68-2-11 1658G 106 M1 circuit-breakers 1-36 UNS-2B GERMANY 106-P10
    Text: Thermal Overcurrent Circuit Breakers 104/105/106-. Description Miniaturised single pole thermal circuit breaker with push-to-reset tease free, trip-free, snap action mechanism R-type TO CBE to EN 60934 . Available in versions for PCB or panel mounting, snap-in or


    Original
    106-M1 28-thread, 27-thread, 28UNEF-2B 27-thread 28-thread IEC-664 insulation distances 106m1 DIN 40050 Part 9 IEC 529 IEC 68-2-11 1658G 106 M1 circuit-breakers 1-36 UNS-2B GERMANY 106-P10 PDF

    RUST

    Abstract: NEMA Level IV
    Text: ON THE BUTTON A reference guide to environmental ratings used for push button enclosures A REFERENCE GUIDE TO KEY TOPICS IN PUSH BUTTON SELECTION AND SAFETY CONTENTS I. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 II. ENCLOSURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


    Original
    PDF

    Ericsson bts installation guide

    Abstract: ericsson BTS and antenna installation ericsson BTS GSM 1800 Nokia BTS ericsson bts Technical specification BTS Base Terminal alcatel indoor BTS of ericsson siemens 230 gas discharge tube TNC PROTECTIVE CAP BTS 6000 ericsson
    Text: Lightning Protectors Edition 2008/2009 Excellence in Connectivity Solutions Introduction content Introduction page 6 Definitions and terms page 27 Quick selection page 37 Products page 53 Accessories page 129 Application notes page 143 General information


    Original
    PDF

    Ericsson bts installation guide

    Abstract: ericsson BTS and antenna installation Ericsson tma for gsm 900 Ericsson tma ericsson bts Technical specification ericsson BTS GSM 1800 TMA ericsson 1800 BTS 6000 ericsson BTS Base Terminal alcatel SCHEMATIC DIAGRAM OF 2.4 GHZ WIFI RF POWER
    Text: General, detailed selection flow chart for HUBER+SUHNER lightning protectors HUBER+SUHNER – Excellence in Connectivity Solutions HUBER+SUHNER is a leading global supplier of components and systems for electrical and optical connectivity in communications, industrial and transportation markets.


    Original
    prot061 BNC-0-0-15 Ericsson bts installation guide ericsson BTS and antenna installation Ericsson tma for gsm 900 Ericsson tma ericsson bts Technical specification ericsson BTS GSM 1800 TMA ericsson 1800 BTS 6000 ericsson BTS Base Terminal alcatel SCHEMATIC DIAGRAM OF 2.4 GHZ WIFI RF POWER PDF

    EN 50205 dold

    Abstract: DPDT 12V 5A DC Relay 06081 24VDC relay pcb mount dold OA 5669 12V RELAY 2NO 2NC RELAY PCB mount DPDT 12V 15 amp 14 pin bd 5987 OA-11 solid state relay 240v 10a pcb
    Text: Altech Corporation Since 1984, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff of engineering, manufacturing and sales personnel to provide the highest quality products with superior service. This is the Altech


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Safety_Relays_2008.QXD_SafetyRelays2005.QXD 1/8/13 9:29 AM Page 2 Altech Corporation Since 1984, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff of engineering, manufacturing


    Original
    SafetyRelays2005 PDF

    OA 5621

    Abstract: dold OA 5621 solid state relay 240v 10a pcb OA56 1500VA bd5987 RELAY PCB mount DPDT 12V 15 amp 14 pin bd 5987 OA70 56.OW70.2431C
    Text: Altech Corporation Since 1984, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff of engineering, manufacturing and sales personnel to provide the highest quality products with superior service. This is the Altech


    Original
    PDF

    relay 5 pin 12v 6a

    Abstract: normal relay for controlling 230v ac by using 5v dold OA 5669 DPDT relay 12v 12V RELAY 2NO 2NC 5 pin relay 12vdc OA 5669 RELAY PCB DPDT 12V relay 12v 10a relay 24v 10a
    Text: Altech Corporation Since 1984, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff of engineering, manufacturing and sales personnel to provide the highest quality products with superior service. This is the Altech


    Original
    PDF

    smd 3528 led strip

    Abstract: led lamp 230v circuit diagram SMD marking code GEM 3524 smd strip Lr 47016 3014 LED smd 1W HIGH BRIGHT LED 230V CIRCUITS SMD CAPACITORS grey color code touch plate piezo 3014 LED
    Text: Switches and Indicators – Panel and Pcb Mount ISO 9001 / ISO 14001 Board mount switches. Keytop styles available in various shapes, sizes, heights and colors. Momentary action Pcb mounting SMT mounting 1 pole switching N.C. contact function Series SMS / PMS / PMK 1/2"


    Original
    PDF

    capacitive touch sensor pcb guideline

    Abstract: ticomel transformer electronic passive components catalog EN132400 znr 10k varistor s241000 5500.206 "SCHURTER" "Catalogue"
    Text: Product Group Catalog EMC Products www.schurter.com/emc 1-Phase Line Filters  www.schurter.com > summary Intro Information 4 1-phase line filters Keyword Index Product Datasheets 6 6 12 General Product Information Product Standard / Definitions / CE-Marking / Conformity


    Original
    PDF

    design of earth busbar for 50kA fault level system

    Abstract: BUSBAR calculation free 400a mccb Switchboard BUSBAR calculation of lv switchboard earth BUSBAR calculation traffolyte ral 7035 paint EN60439-1 raychem arresters
    Text: Energy Division http://energy.tycoelectronics.com Loadframe 25/63 LV Switchboard System Loadframe 25/63 LV Switchboard System The Loadframe family of factory-assembled switchboards comprehensively covers all LV switchboard requirements up to 6300A 4.5MVA . This range of Type Tested


    Original
    PDF

    ZO 607 TRIAC

    Abstract: RTCA DO-160 iso 7137 TRIAC zo 607 MA NAS 1149 MS3320 EN3155 Cross Reference Full Line Condensed Catalogue 1977 DIN 72585 a1 4.1 RBS 6302 NAS1149
    Text: Contents Introduction Thermal Overcurrent Circuit Breakers Thermal-Magnetic Overcurrent Circuit Breakers Hydraulic-Magnetic and Magnetic Overcurrent Circuit Breakers High Performance Circuit Breakers and Battery Switches Door Locking, Time Delay and Motor Protection Controls


    Original
    PDF

    inductive proximity sensor npn

    Abstract: pulsotronic symbol inductive proximity sensor inductive sensor oscillator circuit INDUCTIVE PROXIMITY SENSOR analogue proximity-Sensor circuit "inductive Proximity Sensors" eddy Proximity Sensor inductive speed sensor interface proximity sensor
    Text: NEXT FIND IT Table of Contents CLICK FOR PDF FILE CLICK FOR PDF FILE OVERVIEW – Inductive Proximity Sensors CYLINDRICAL Inductive Proximity Sensors LIMIT STYLE Inductive Proximity Sensors Introduction .4 Operation .5


    Original
    PDF