TRIODE itl 12-1
Abstract: thales ITL 12-1 ITL 12-1 TRIODE itl ITL12-1 thales ITL 12 Thales Electron Devices ITL12-1 Forced-air cooled triode THALES tube TRIODE itl 12
Text: INDUSTRIAL RF HEATING ITL12-1 Forced-air cooled triode 33 kW Output power: 33 kW in CW mode Anode voltage: 12 kV Anode dissipation: 12 kW Frequency up to 120 MHz INDUSTRIAL RF HEATING T he ITL 12-1 is a RF power triode designed specifically for industrial
|
Original
|
PDF
|
ITL12-1
TRIODE itl 12-1
thales ITL 12-1
ITL 12-1
TRIODE itl
ITL12-1
thales ITL 12
Thales Electron Devices
ITL12-1 Forced-air cooled triode
THALES tube
TRIODE itl 12
|
thales itl 15-2
Abstract: ITL 15-2 Power Triode ITL 15-2 TRIODE itl ITL15-2 thales ITL 12 ITL 15-2 TRIODE TUBE thales TRIODE itl 5 "Power Triode"
Text: INDUSTRIAL RF HEATING ITL15-2 Forced-air cooled triode 45 kW Output power: 45 kW in CW mode Anode voltage: 13 kV Anode dissipation: 17 kW Frequency up to 120 MHz INDUSTRIAL RF HEATING T he ITL 15-2 is a RF power triode designed specifically for industrial
|
Original
|
PDF
|
ITL15-2
thales itl 15-2
ITL 15-2
Power Triode ITL 15-2
TRIODE itl
ITL15-2
thales ITL 12
ITL 15-2 TRIODE TUBE
thales
TRIODE itl 5
"Power Triode"
|
TRIODE itl 3-1
Abstract: TRIODE itl thales "Power Triode" INDUSTRIAL RF HEATING itl 2-1
Text: INDUSTRIAL RF HEATING ITL 3-1 Forced-air cooled triode 6.7 kW Output power: 6.7 kW in CW mode Anode voltage: 7.2 kV Anode dissipation: 3.5 kW Frequency up to 160 MHz INDUSTRIAL RF HEATING T he ITL 3-1 is a RF power triode designed specifically for industrial
|
Original
|
PDF
|
|
thales
Abstract: TRIODE itl thales ITL 12 THALES tube TRIODE itl 8-1 ITL 25.1 "Power Triode" ITL 9
Text: INDUSTRIAL RF HEATING ITL 25-1 Forced-air cooled triode 75 kW Output power: 75 kW in CW mode Anode voltage: 12 kV Anode dissipation: 30 kW Frequency up to 100 MHz INDUSTRIAL RF HEATING T he ITL 25-1 is a RF power triode designed specifically for industrial
|
Original
|
PDF
|
|
thales
Abstract: TRIODE itl thales ITL 12 "Power Triode"
Text: INDUSTRIAL RF HEATING ITL 25-3 Forced-air cooled triode 84 kW Output power: 84 kW in CW mode Anode voltage: 12 kV Anode dissipation: 30 kW Frequency up to 100 MHz INDUSTRIAL RF HEATING T he ITL 25-3 is a RF power triode designed specifically for industrial
|
Original
|
PDF
|
|
TRIODE itl
Abstract: TRIODE itl 9-1 thales ITL 12 TRIODE itl 9.1 thales TRIODE itl 5 ITL 9 industrial air cooler thales ITL 9-1
Text: INDUSTRIAL RF HEATING ITL 9-1 Forced-air cooled triode 25 kW Output power: 25 kW in CW mode Anode voltage: 12 kV Anode dissipation: 8.5 kW Frequency up to 120 MHz INDUSTRIAL RF HEATING T he ITL 9-1 is a RF power triode designed specifically for industrial
|
Original
|
PDF
|
|
TRIODE itl
Abstract: INDUSTRIAL RF HEATING itl 2-1 ELECTRON TUBE 10 thales TRIODE itl 5 itl 2-1 TRIODE itl 1-2 "Power Triode" TRIODE itl 5-1 K1-AT
Text: INDUSTRIAL RF HEATING ITL 2-1 Forced-air cooled triode 5 kW Output power: 5 kW in CW mode Anode voltage: 7.2 kV Anode dissipation: 1.5 kW Frequency up to 160 MHz INDUSTRIAL RF HEATING T he ITL 2-1 is a RF power triode designed specifically for industrial applications.
|
Original
|
PDF
|
|
TRIODE itl 5-1
Abstract: TRIODE itl itl 5-1 TRIODE itl 5.1 417a tube thales THALES tube P417A TRIODE itl 5 "Power Triode"
Text: INDUSTRIAL RF HEATING ITL 5-1 Forced-air cooled triode 13 kW Output power: 13 kW in CW mode Anode voltage: 7.2 kV Anode dissipation: 6 kW Frequency up to 150 MHz INDUSTRIAL RF HEATING T he ITL 5-1 is a RF power triode designed specifically for industrial applications.
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Master Model GT-70 Industrial Torch Instructions Mode d'emploi du chalumeau industriel modèle GT-70 Instrucciones para el uso del soplete industrial modelo GT-70 Air Control Ring Anneau de régulation d’air Anillo de control del aire Fuel Adjustment Knob
|
Original
|
PDF
|
GT-70
GT-70
|
40691
Abstract: 40693A wia 102 YD1170 YD1172 40690
Text: YD1170/8666 YD1172/8668 RF Power Triodes Triodes in metal-ceramic construction intended for use as industrial oscillators. The YD1170 is forced-air cooled. The YD1172 has an integral helical water cooler. GENERAL DATA Electrical: Filament-Thoriated TungstenNote 1
|
Original
|
PDF
|
YD1170/8666
YD1172/8668
YD1170
YD1172
Wat/8666
0692A
0693A
40691
40693A
wia 102
40690
|
YD1178FL
Abstract: YD1174FL YD1174 YD117 C4667 ABOVE50MHz
Text: YD1174FL YD1178FL RF Power Triodes The YD1174FL and YD1178FL are RF power triodes in metal-ceramic construction with flying leads intended for use as industrial oscillators. The YD1174FL is forced-air cooled. The YD1178FL has an integral water cooler. GENERAL DATA
|
Original
|
PDF
|
YD1174FL
YD1178FL
YD1174FL
YD1178FL
YD1174
YD117
C4667
ABOVE50MHz
|
YD1185
Abstract: 8935 8956 Amperex 40711 8936 v 3 Power Triode YD1187 YD1187 8936 amperex transmitting
Text: YD1185/8935 YD1187/8956 RF Power Triodes The YD1185/8935 and YD1187/8936 are RF power triodes in metal-ceramic construction intended for use as industrial oscillators. The YD1185 is forced-air cooled. The YD1187 has an integral water cooler. GENERAL DATA Electrical:
|
Original
|
PDF
|
YD1185/8935
YD1187/8956
YD1185/8935
YD1187/8936
YD1185
YD1187
0708A
0709A
8935
8956 Amperex
40711
8936 v 3
Power Triode YD1187
8936
amperex transmitting
|
40707
Abstract: YD1197 8937 YD1195 8913 40736
Text: YD1195/8913 YD1197/8937 RF Power Triodes The YD1195/8913 and YD1197/8937 are RF power triodes in metal-ceramic construction intended for use as industrial oscillators. The YD1195 is forced-air cooled. The YD1197 has an integral water cooler. GENERAL DATA Electrical:
|
Original
|
PDF
|
YD1195/8913
YD1197/8937
YD1195/8913
YD1197/8937
YD1195
YD1197
YD1195/89nnector
0705A
0706A
40707
8937
8913
40736
|
YD1175
Abstract: 8952 8958 amperex transmitting Amperex yd1175/8952 40693A YD1177 YD117 40693 40691
Text: YD1175/8952 YD1177/8958 RF Power Triodes The YD1175/8952 and YD1177/8958 are RF power triodes in metal-ceramic construction intended for use as industrial oscillators. The YD1175 is forced-air cooled. The YD1177 has an integral water cooler. GENERAL DATA Electrical:
|
Original
|
PDF
|
YD1175/8952
YD1177/8958
YD1175/8952
YD1177/8958
YD1175
YD1177
YD1177/8952
8952
8958
amperex transmitting
Amperex yd1175/8952
40693A
YD1177
YD117
40693
40691
|
|
Infineon technology roadmap for mosfet
Abstract: LFPAK88 Acbel schematic diagram switching power supply BLDC TRW schematic diagram inverter air conditioner schematic diagram for split air conditioner TRIAC 20A 600V inverter schematic ims 1600 triac 4A, 600V, 5mA triac 0,8A, 600V, 5mA
Text: NXP PowerMOS, BIPOLAR and Motor Control Smaller, Faster, Cooler June 05, 2014 Nicolas Rescanieres Field Application Engineer South of France NXP PowerMOS 1 Agenda MosFET in automotive and industrial Bipolar Motor Control Agenda MosFET in automotive and industrial
|
Original
|
PDF
|
KMZ60
KMA210
KMA215
Infineon technology roadmap for mosfet
LFPAK88
Acbel schematic diagram switching power supply
BLDC TRW
schematic diagram inverter air conditioner
schematic diagram for split air conditioner
TRIAC 20A 600V
inverter schematic ims 1600
triac 4A, 600V, 5mA
triac 0,8A, 600V, 5mA
|
Untitled
Abstract: No abstract text available
Text: PRODUCT DATASHEET SynJet Outdoor Electronics Cooler L100-90 SynJet cooling provides the most reliable thermal management solution available. This cooler has been developed by Nuventix for cooling Industrial, Telecom, and other electronic systems. •
|
Original
|
PDF
|
L100-90
600mm
L100-90,
MKTG-DOC-00179
|
YD1175
Abstract: YD1177
Text: YD1175 YD1177 8952 RF POWER TRIODE Triodes in metal-ceramic construction intended fo r use as industrial oscillators. The YD1175 is forced-air cooled. The YD 1177 has an integral water cooler. QUICK REFERENCE DATA Oscillator output power Wo—Wfeedb , typical
|
OCR Scan
|
PDF
|
YD1175
YD1177
YD1175
085max-
YD1175.
YD1177
|
YD1190
Abstract: No abstract text available
Text: YD1190 YD1192 8736 RF POWER TRIODE Triodes in metal-ceramic construction intended fo r use as industrial oscillators. The YD 1190 is forced-air cooled. The YD 1192 has an integral water cooler. QUICK REFERENCE DATA Oscillator ou tput power WQ—Wfeec|b , typical
|
OCR Scan
|
PDF
|
YD1190
YD1192
YD1192
YD1190
YD1190/YD1192
YD1190.
|
40689
Abstract: 40688
Text: YD1240 YD1244 RF POWER TRIODE Air-cooled triodes o f metal-ceramic construction w ith integral cooler intended fo r use as industrial oscillators. QUICK REFERENCE D A T A Oscillator ou tput power W0-W feec|b , typical Frequency fo r fu ll ratings 2,67 kW
|
OCR Scan
|
PDF
|
YD1240
YD1244
YD1240.
p-048Â
YD1244.
40689
40688
|
YD1150A
Abstract: No abstract text available
Text: YD1150A 8728 J v_ RF POWER TRIODE Triode in metal-ceramic construction, intended fo r use as industrial oscillator. The tube is forced-air cooled, w ith integral cooler. QUICK REFERENCE DATA Oscillator ou tput power W0 — Wfeec|b , typical W0SC f Frequency fo r fu ll ratings
|
OCR Scan
|
PDF
|
YD1150A
YD1150A
|
A01A
Abstract: No abstract text available
Text: YD1154 _ RF POWER TRIODE Forced air cooled triode o f metal-ceramic construction w ith integral cooler intended fo r use as an industrial oscillator. Q UICK REFERENCE D A T A Oscillator o u tp u t power W0 —Wfeetjt, , typical Wosc Frequency fo r fu ll ratings
|
OCR Scan
|
PDF
|
YD1154
A01A
|
YD1160
Abstract: YD1162
Text: YD1160 YD1162 8731 8733 RF POWER TRIODE Triodes in metal-ceramic construction intended fo r use as industrial oscillators. The YD1160 is forced-air cooled, w ith integral cooler. The Y D 1 162 has an integral water cooler. QUICK REFERENCE D A T A Oscillator ou tput power W0 - W feecjback ' typical
|
OCR Scan
|
PDF
|
YD1160
YD1162
YD1160
YD1160.
VD1162.
YD1162
|
YD1174
Abstract: No abstract text available
Text: YD1174 YD1178 RF POWER TRIODE Triodes in metal-ceramic construction w ith flyin g leads intended fo r use as industrial oscillators. The Y D 1 174 is forced-air cooled. The Y D 1 178 has an integral water cooler. Q UICK REFERENCE D A T A Oscillator ou tput power WQ — W feecjt>
|
OCR Scan
|
PDF
|
YD1174
YD1178
YD1174
YD1178
YD1174.
YD1178.
|
TY8-6000A
Abstract: 6000A 6000W 8-240-38 10kw power Triode water inlet valve "Power Triode" RECTIFIER GI TY8-6000H
Text: V.H.F. P O W E R T R IO D E TY8-6000A TY8-6000W TY8-6000H TENTATIVE DATA QUICK REFERENCE DATA External anode trio d e, intended for use as industrial Class 'C' oscillator The TY8-6000A is fo rced-air cooled. The TY8-6000W is w ater cooled by means of a w ater jacket.
|
OCR Scan
|
PDF
|
TY8-6000A
TY8-6000W
TY8-6000H
TY8-6000A
TY8-6000W
TY8-6000H
6000A
6000W
8-240-38
10kw power Triode
water inlet valve
"Power Triode"
RECTIFIER GI
|