Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    IMPULSE COUNTER Search Results

    IMPULSE COUNTER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    SN74HC393ANSR
    Texas Instruments Dual 4-Bit Binary Counters Visit Texas Instruments Buy
    SN74HC4040ANSR
    Texas Instruments 12-Bit Asynchronous Binary Counters Visit Texas Instruments Buy
    SN74HC161APWR
    Texas Instruments 4-Bit Synchronous Binary Counters Visit Texas Instruments Buy
    SN74HC161ANSR
    Texas Instruments 4-Bit Synchronous Binary Counters Visit Texas Instruments Buy
    SN74HC163ANSR
    Texas Instruments 4-Bit Synchronous Binary Counters Visit Texas Instruments Buy

    IMPULSE COUNTER Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    impulse encoder 250

    Abstract: pg9 gland Baumer 10A101
    Contextual Info: Special Encoders & Sensors Contact encoder, surface mount housing Impulse ratio 1 rev. = 15 impulses up to 5 rev. = 1 impulse G 080 Features –– Encoder with mechanical contact –– As trigger for electromechanical counters –– Impulse voltage 12.230 VAC/VDC


    Original
    PDF

    Contextual Info: Totalizers electronic Small impulse counters and position displays Display LCD, 8-digits ISI30, ISI31, ISI32, ISI33 Features – ISI30 - Impulse counterISI31 - Up/down, difference counter – ISI32 - Up/down counter – ISI33 - Position display ISI30 - Totalizer


    Original
    ISI30, ISI31, ISI32, ISI33 ISI30 ISI31 ISI32 ISI33 PDF

    Contextual Info: Type W17.50 dimensions 34x23.49.3 supplied to by Kübler - 7 digit miniature adding counter without reset - power consumption min. 50mW - impulse length of 50ms = 2.5mWs/impulse - long service life - flush mount counter with spring clip - cut out 48x24mm applications:


    Original
    34x23 48x24mm 130mW 150mm 50x106 12VDC 24VDC 230VAC PDF

    74HCT00 HARRIS

    Abstract: AN9740 HARRIS 74HCT123 transistor 9740 diode 1334 74HCT00 74HCT193 74HCT32 HA4600
    Contextual Info: Harris Semiconductor No. AN9740 Harris Linear July 1997 Digital Control Selects The Number of Analog Cycles and Burst Frequency Authors: Alan Erzinger and Ron Mancini Introduction Repetitive pulse bursts are required for impulse testing and for burst data transmission schemes. Impulse testing subjects the device under test to a unit impulse or doublet, and


    Original
    AN9740 1-800-4-HARRIS 74HCT00 HARRIS AN9740 HARRIS 74HCT123 transistor 9740 diode 1334 74HCT00 74HCT193 74HCT32 HA4600 PDF

    optocoupler pnp

    Abstract: optocoupler pnp or npn 4 DIGIT LCD DISPLAY 40 PIN 4 digit up counter diagram 8 Digit count down counting 013AB01 ISI310
    Contextual Info: Totalizers electronic Small impulse counters and position displays Display LCD, 8-digits ISI30, ISI31, ISI32, ISI33 Features –– ISI30 - Impulse counter –– ISI31 - Up/down, difference counter –– ISI32 - Up/down counter –– ISI33 - Position display


    Original
    ISI30, ISI31, ISI32, ISI33 ISI30 ISI31 ISI32 ISI33 optocoupler pnp optocoupler pnp or npn 4 DIGIT LCD DISPLAY 40 PIN 4 digit up counter diagram 8 Digit count down counting 013AB01 ISI310 PDF

    Contextual Info: Electromechanical impulse countersImpulse counters - CIM 36 x 37 • 5 or 6 digits, height of digits 4 mm ■ With or without manual reset ■ White digits on a black background Part numbers Type Without manual reset With manual reset Number of digits


    Original
    PDF

    99776711

    Abstract: 99776707
    Contextual Info: Electromechanical impulse countersImpulse counters - CIM 36 x 48 • 5 or 6 digits, height of digits 4 mm ■ With or without manual reset ■ White digits on a black background Part numbers Type Without manual reset With manual reset Number of digits


    Original
    PDF

    Contextual Info: Totalizers electromechanic Impulse counters adding, modular system Display 6- or 8-digits, with/without reset button F 304, F 314, F 324, F 364 Features – Impulse counter – Adding – Display 6- or 8-digits – With or without reset button – Socket box


    Original
    PDF

    Contextual Info: Electromechanical impulse countersImpulse counters 24 x 48 - CIM24 • 5 or 6 digits, height of digits 4 mm ■ With or without manual reset ■ White digits on a black background Part numbers Type Without manual reset With manual reset Number of digits


    Original
    CIM24 26mited 25X50 PDF

    Contextual Info: Totalizers electromechanic Impulse counters, front panel mount Display 6- or 8-digits, with/without reset button F 504, F 514, F 524 Features – Impulse counter – Adding – Display 6- or 8-digits – With or without reset button / key reset F 504 - Socket box


    Original
    PDF

    impulse counter

    Contextual Info: Dual-function electromechanical counters ➜ Dual-function counters hour counter and impulse counter 48 x 48 • Dual-function counter (hour counter and impulse ■ ■ ■ ■ ■ ■ ■ counter) Va : capacity 100.000 hrs (99.999.99 hrs) Vc : capacity 1.000.000 hrs (999.999.99 hrs)


    Original
    CMM48 fo/100 VA/187 impulse counter PDF

    MW50X

    Abstract: CIM15
    Contextual Info: Electromechanical impulse countersImpulse counters with built-in fixing clip - 15 x 32 - CIM15 • ■ ■ ■ ■ ■ 7 digits, height of digits 4 mm Without manual reset White digits on a black background Compact size Built-in fixing clip IP65 panel only


    Original
    CIM15 MW50X CIM15 PDF

    Contextual Info: Totalizers electromechanic Small impulse counters, adding Display 4- or 6-digits, with/without reset button F 102, F 112, F 122 Features – Small impulse counter – Adding – Display 4- or 6-digits – With or without reset button F 102 - Center screw mount at rear


    Original
    PDF

    Contextual Info: Electromechanical impulse counters ➜ Screw-fixing impulse counters - CIM 24 x 48 • 5 or 6 digits, height of digits 4 mm ■ With or without manual reset ■ White digits on a black background Part numbers Type Without manual reset With manual reset Number of digits


    Original
    PDF

    reset button switches

    Abstract: 100-01A f 324 f364 F-364 reset button 800B
    Contextual Info: Totalizers electromechanic Impulse counters adding, modular system Display 6- or 8-digits, with/without reset button F 304, F 314, F 324, F 364 Features –– Impulse counter –– Adding –– Display 6- or 8-digits –– With or without reset button


    Original
    PDF

    QED1000

    Abstract: digital FIR Filter using frequency sampling method circuit diagram for iir and fir filters adsp 21xx processor advantages VLSI implementation of FIR filters c code for interpolation and decimation filter chebyshev 0.01dB AD1892 iir filter diagrams FIGURE 9 CIRCUIT DIAGRAM OF FIR AND IIR FILTERS
    Contextual Info: DIGITAL FILTERS SECTION 6 DIGITAL FILTERS • Finite Impulse Response FIR Filters ■ Infinite Impulse Response (IIR) Filters ■ Multirate Filters ■ Adaptive Filters 6.a DIGITAL FILTERS 6.b DIGITAL FILTERS SECTION 6 DIGITAL FILTERS Walt Kester INTRODUCTION


    Original
    ADSP-21000 QED1000 digital FIR Filter using frequency sampling method circuit diagram for iir and fir filters adsp 21xx processor advantages VLSI implementation of FIR filters c code for interpolation and decimation filter chebyshev 0.01dB AD1892 iir filter diagrams FIGURE 9 CIRCUIT DIAGRAM OF FIR AND IIR FILTERS PDF

    Contextual Info: Totalizers electromechanic Small impulse counters, adding Display 5- or 7-digits, with/without reset button F 503, F 513, F 523 Features – Small impulse counter – Adding – Display 5- or 7-digits – With or without reset button F 503 - Center screw mount at rear


    Original
    PDF

    4 Digit counter

    Abstract: f 102 reset button reset button switches
    Contextual Info: Totalizers electromechanic Small impulse counters, adding Display 4- or 6-digits, with/without reset button F 102, F 112, F 122 Features –– Small impulse counter –– Adding –– Display 4- or 6-digits –– With or without reset button F 102 - Center screw mount at rear


    Original
    PDF

    reset button switches

    Abstract: 8 digit counter PPO NORYL 100-01A F 514 F 524 reset button 600B 650D
    Contextual Info: Totalizers electromechanic Impulse counters, front panel mount Display 6- or 8-digits, with/without reset button F 504, F 514, F 518, F 524 Features –– Impulse counter –– Adding –– Display 6- or 8-digits –– With or without reset button / key reset


    Original
    PDF

    reset button

    Abstract: button pin diagram x 300 f F523 impulse counter
    Contextual Info: Totalizers electromechanic Small impulse counters, adding Display 5- or 7-digits, with/without reset button F 503, F 513, F 523 Features –– Small impulse counter –– Adding –– Display 5- or 7-digits –– With or without reset button F 503 - Center screw mount at rear


    Original
    PDF

    80286 microprocessor features

    Abstract: 80286 Microprocessor x-band filter x band radar transmitters digital filter calculus how dsp is used in radar microprocessor 80286 Spectrum Signal Processing x band radar c code for convolution
    Contextual Info: CHAPTER 7 Properties of Convolution A linear system's characteristics are completely specified by the system's impulse response, as governed by the mathematics of convolution. This is the basis of many signal processing techniques. For example: Digital filters are created by designing an appropriate impulse


    Original
    PDF

    fixed point IIR Filter

    Abstract: FIR FILTER implementation in ARM instruction ARM966E-S STR910-EVAL ARM966E-S microcontroller 265-1051 STMicroelectronics DFT Library 4101-062
    Contextual Info: UM0304 User manual STR91x DSP library DSPLIB Introduction This manual presents a library of ARM assembly source code modules for digital signal processing (DSP) applications such as infinite impulse response (IIR) filter, finite impulse response (FIR) filter and fast Fourier transform (FFT) applicable for a range of DSP


    Original
    UM0304 STR91x fixed point IIR Filter FIR FILTER implementation in ARM instruction ARM966E-S STR910-EVAL ARM966E-S microcontroller 265-1051 STMicroelectronics DFT Library 4101-062 PDF

    small capacitive oil level sensor

    Abstract: DOL-1208-G05M DOL-1208-G10M LFT1100-01B1A20 m12x1 female connector LFT1000-01B1A20 m12x1.5 female connector DOL-1205-W10MA DOL-1208-G02M LFT0700-01B1A20
    Contextual Info: S H E E T LFT level sensor the all-round talent with TDR technology A T A the impulse is reflected there and runs along the probe back to the D electronics, which then calculates the fill level from the time difference between the impulse sent out and the received on. The sensor can


    Original
    DOL-1208-W05MC DOL-1208W10MC M12x1 AC/24 small capacitive oil level sensor DOL-1208-G05M DOL-1208-G10M LFT1100-01B1A20 m12x1 female connector LFT1000-01B1A20 m12x1.5 female connector DOL-1205-W10MA DOL-1208-G02M LFT0700-01B1A20 PDF

    kwh meter IC

    Abstract: energy meter circuit diagram tz76 kwh meter circuit diagram 3phase ct kwh meter 3 phase kwh meter LED LEVEL METER DRIVER pot meter 100k pin configuration clamp current transformer ct3 "current sensor"
    Contextual Info: Programmable Three Phase Power / Energy Metering IC for Stepper Motor / Impulse Counter Applications sames SA2005P FEATURES + Direct drive for + + + + electro-mechanical counters or stepper + motors Calibration and setup stored on external EEPROM - no trim-pots required


    Original
    SA2005P kwh meter IC energy meter circuit diagram tz76 kwh meter circuit diagram 3phase ct kwh meter 3 phase kwh meter LED LEVEL METER DRIVER pot meter 100k pin configuration clamp current transformer ct3 "current sensor" PDF