Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    HVAC DAMPER Search Results

    HVAC DAMPER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    10120260-111-202LF Amphenol Communications Solutions Plug, 4 Pair, 5 Column, 6mm Height, 85Ω, With Damper, Lead Free Visit Amphenol Communications Solutions
    10120300-131-202LF Amphenol Communications Solutions Receptacle, 4 Pair, 15 Column, 9mm Height, 85Ω, With Damper, Lead Free Visit Amphenol Communications Solutions
    10120260-110-102LF Amphenol Communications Solutions Plug, 4 Pair, 5 Column, 6mm Height, 85Ω, Without Damper, Lead Free Visit Amphenol Communications Solutions
    10120300-130-102LF Amphenol Communications Solutions Receptacle, 4 Pair, 15 Column, 9mm Height, 85Ω, Without Damper, Lead Free Visit Amphenol Communications Solutions
    10120260-131-102LF Amphenol Communications Solutions Plug, 4 Pair, 15 Column, 6mm Height, 85Ω, With Damper, Lead Free Visit Amphenol Communications Solutions

    HVAC DAMPER Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    HVAC damper

    Abstract: HVAC lin bus HVAC KIT33880DWBEVB MC33880 "DC Drive" control RD68HC908
    Text: STATE MACHINE HVAC DAMPER DOORS APPLICATION LIN SPI Regulator LSR Configurable Octal Switch (MC33880) Application Features The LIN-controlled HVAC damper door slave application was developed to show multiple integrated LIN node components in a cost-effective system.


    Original
    PDF MC33880) MC33880 54-pin APDHVACD880LSRFS RD68HC908QY4LKS HVAC damper HVAC lin bus HVAC KIT33880DWBEVB "DC Drive" control RD68HC908

    ABB inverter motor fault code

    Abstract: 3 phase squirrel cage ABB motor star delta vlt 2900 FC102 abb variable frequency drive wiring diagram PT100 temperature sensor ABB motor ABB inverter motor fault MG16C102 DANFOSS ps 9 b DANFOSS ps 4 b
    Text: MAKING MODERN LIVING POSSIBLE Design Guide VLT HVAC Drive FC 102 110-1400 kW www.danfoss.com/drives Contents VLT® HVAC Drive FC 102 Design Guide Contents 1 How to Read this Design Guide 2 Introduction 8 14 2.1 Safety 14 2.2 CE Labelling 15 2.2.1 CE Conformity and Labelling


    Original
    PDF 2004/108/EC MG16C102 130R0278 MG16C102 MG16C102* ABB inverter motor fault code 3 phase squirrel cage ABB motor star delta vlt 2900 FC102 abb variable frequency drive wiring diagram PT100 temperature sensor ABB motor ABB inverter motor fault DANFOSS ps 9 b DANFOSS ps 4 b

    1414-CTZ03PBRAA

    Abstract: 1414-ITZ02GBRAA 1414-CTX03PDDAA pcb split hvac 1414-CHZ30PKRAA 1414-CHD30PKRAA rtd sensor Allen-Bradley 1414-ITZ02FAOAA in007
    Text: Selection Guide Power and Energy Management Solutions Heating, Ventilating and Air Conditioning Bulletin 1414 Selection Guide 2 HVAC Selection Guide Instrumentation Selection Checklist Use the following checklist as a guide to completing your own system


    Original
    PDF 1414-SG001A-EN-P 1414-CTZ03PBRAA 1414-ITZ02GBRAA 1414-CTX03PDDAA pcb split hvac 1414-CHZ30PKRAA 1414-CHD30PKRAA rtd sensor Allen-Bradley 1414-ITZ02FAOAA in007

    SRSF-61T-250A

    Abstract: DC24 E41643 G2RL-14 G2RL-14-E G2RL-24 LR31928 VDE0435 rsfp omron g2rl-1
    Text: PCB Relay G2RL High Capacity, Low Profile Relay D D D D D D Designed for cooking and HVAC controls: blower motor, damper, active air purification, duct flow boost fans, etc. 10 kV impulse surge withstand. Available in traditional full PCB mounting or with PCB


    Original
    PDF J01C-E-01 SRSF-61T-250A DC24 E41643 G2RL-14 G2RL-14-E G2RL-24 LR31928 VDE0435 rsfp omron g2rl-1

    g2rl

    Abstract: RELAY OMRON G2RL-112VDC
    Text: PCB Relay G2RL A Power Relay with Various Models • High-sensitivity 250 mW and High-capacity (16 A) versions. • Designed for cooking and HVAC controls: blower motor, damper, active air purification, duct flow boost fans, etc. • Conforms to VDE (EN61810-1). UL recognized/ CSA certiified


    Original
    PDF EN61810-1) EN60335-1 mm/10 G2RL-14 G2RL-24 X301-E-1b g2rl RELAY OMRON G2RL-112VDC

    Untitled

    Abstract: No abstract text available
    Text: PCB Relay G2RL A Power Relay with Various Models • High-sensitivity 250 mW and High-capacity (16 A) versions. • Designed for cooking and HVAC controls: blower motor, damper, active air purification, dusct flow boost fans, etc. • Conforms to VDE (EN61810-1), UL508 and CSA22.2.


    Original
    PDF EN61810-1) UL508 CSA22 EN60335-1 mm/10 UL1446) G2RL-14 J01C-E-01a

    G2RL-24

    Abstract: RELAY OMRON G2RL-1-E
    Text: PCB Relay G2RL A Power Relay with Various Models • High-sensitivity 250 mW and High-capacity (16 A) versions. • Designed for cooking and HVAC controls: blower motor, damper, active air purification, duct flow boost fans, etc. • Conforms to VDE (EN61810-1). UL recognized/ CSA certiified


    Original
    PDF EN61810-1) EN60335-1 mm/10 G2RL-14 X301-E-1b G2RL-24 RELAY OMRON G2RL-1-E

    g2rl-24 dc12

    Abstract: HVAC damper g2rl-1a-e E41643 EN60335-1 EN61810-1 G2RL-14 G2RL-14-E G2RL-24 LR31928
    Text: PCB Relay G2RL A Power Relay with Various Models • High-sensitivity 250 mW and High-capacity (16 A) versions. • Designed for cooking and HVAC controls: blower motor, damper, active air purification, duct flow boost fans, etc. • Conforms to VDE (EN61810-1). UL recognized/ CSA certiified


    Original
    PDF EN61810-1) EN60335-1 mm/10 G2RL-14 G2RL-24 X301-E-1 g2rl-24 dc12 HVAC damper g2rl-1a-e E41643 EN61810-1 G2RL-14 G2RL-14-E G2RL-24 LR31928

    AUTOMATIC cooling fan control

    Abstract: 380V-415V 380V 415v motor ac drives dc 230v DC motor control circuit speed drive
    Text: E3 Adjustable Speed Drive Engineering Specification 1 General 1-1 This specification covers AC adjustable frequency drives for HVAC applications The drive should be a PWM Pulse Width Modulated transistorized inverter using IGBTs (Insulated Gate Bipolar Transistors) and must be


    Original
    PDF ISO-9001 12-pulse 3-15psi) AUTOMATIC cooling fan control 380V-415V 380V 415v motor ac drives dc 230v DC motor control circuit speed drive

    7805 internal circuit diagram

    Abstract: 7805 12v to 5v 7805 internal block diagram simple PWM circuit maxim 233 circuit Thermistor interface with adc maxim 7805 pin diagram of 7805 HVAC damper PIC12C508
    Text: SIMPLE CIRCUIT Simple Closed Loop HVAC Zone Control Author: Depending on the system mode heating or cooling the PIC12C508 will open or close the forced air vent in the room. Steve Swam ADC Telecommunications Minneapolis, Minnesota email: Swam@adc.com The advantage to this system is that it allows discrete


    Original
    PDF PIC12C508 PIC12C508 DS40160A/MP 069-page 7805 internal circuit diagram 7805 12v to 5v 7805 internal block diagram simple PWM circuit maxim 233 circuit Thermistor interface with adc maxim 7805 pin diagram of 7805 HVAC damper

    HM506

    Abstract: honeywell hm509 HE365 sensor 3414 HM512 HM509 Humidifier wireless water pressure sensor Airflow Sensor Breathing
    Text: TrueSTEAM Humidification Reference Guide 2 What's Inside SECTION PAGE Operating


    Original
    PDF

    D-71101

    Abstract: 3KW INDUCTION HEATING POWER SUPPLY centrifugal fans 10 kw control valve air pump variable frequency drive for ac motors variable frequency speed control "variable frequency drive" circuit Centrifugal Pump centrifugal pump data sheet energy saving
    Text: Energy efficiency . . through Variable Frequency Drives 08 I 2008 Tomi Ristimäki Produkt Manager Constantly increasing energy prices have substantially heightened interest among business owners who want to save energy and money. While discussion usually revolves around alternative energy sources and


    Original
    PDF D-71101 3KW INDUCTION HEATING POWER SUPPLY centrifugal fans 10 kw control valve air pump variable frequency drive for ac motors variable frequency speed control "variable frequency drive" circuit Centrifugal Pump centrifugal pump data sheet energy saving

    Untitled

    Abstract: No abstract text available
    Text: 6100 Series AC Hysteresis Motors Larger external rear output bearing Designed with stall torque performance Ultra smooth, ultra quiet operation Rotation direction: CW and CCW Lifetime lubrication UL Approved, Class F Rating Model 6100 with optional shafts


    Original
    PDF C-6100-AC

    Untitled

    Abstract: No abstract text available
    Text: 100 Series AC Permanent Magnet Motors Larger external rear output bearing Designed with stall torque performance Model 113 Quiet operation and back drive capability Rotation direction: CW and CCW Lifetime lubrication Model 107 UL Approved, Class F Rating Model 105


    Original
    PDF C-100-AC

    MEMS flow sensor

    Abstract: mems Flow Sensor in cpap "Flow Sensor" HVAC damper omron pressure sensor cpap SICK DSS sick sensor medical mems spirometer
    Text: PRESS RELEASE For Immediate Release New Dust Resistant MEMS Flow Sensors Deliver Advantages Over Differential Pressure Sensors November 2007—Schaumburg, IL USA—Omron Electronic Components LLC announces the release of the D6F-P MEMS flow sensor that incorporates a unique double cyclone patented Dust Segregation


    Original
    PDF 2007--Schaumburg, MEMS flow sensor mems Flow Sensor in cpap "Flow Sensor" HVAC damper omron pressure sensor cpap SICK DSS sick sensor medical mems spirometer

    Humidifier

    Abstract: 69-2414EF-01 HE200 he250 HE100 transformer humidifiers HE300 HVAC damper regulateur de temperature what size duct work
    Text: Humidifier HOMEOWNER’S OPERATING MANUAL 69-2414EF-01 Humidifier INTRODUCTION INTRODUCTION Safety Definitions and Precautions. . . . . . . . . . . . . . . Welcome . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . How is the humidifier different from other


    Original
    PDF 69-2414EF-01 ON15-02H, 69-2414EF--01 Humidifier 69-2414EF-01 HE200 he250 HE100 transformer humidifiers HE300 HVAC damper regulateur de temperature what size duct work

    Siemens Ni1000 temperature sensor

    Abstract: n531 QAC22 N9292 LG-Ni1000 QFM3100 triac BT 317 DATASHEET
    Text: System Catalog 2014 The information in this document contains general descriptions of technical options available, which do not always have to be present in individual cases. The required features should therefore be specified in each individual case at the time of closing the contract.


    Original
    PDF

    LVDT Signal Conditioner techniques

    Abstract: linear variable displacement transformer schematic air conditioner when lvdt sensor piezoelectric actuator hepatitis b r-type transformer lvdt ML2264 ML2375
    Text: November 1995 Application Note 42003 by James C. Mutzabaugh Data Conversion Design Techniques for Process Control Applications INTRODUCTION Process control technology has developed and adapted from its earliest form of single channel, analog control loops, to enormously complex, multiple parameter control


    Original
    PDF

    polygyr

    Abstract: polygyr RWF 32 SM220-SR SM24S Motor Control Center wiring diagram abb SM24-SR90 SM24-SR rwf 61.3 polygyr RWF 1-14 staefa RS
    Text: B C Actuators for heating, ventilation, air-conditioning Product Information Damper actuators SM i0028811 2. SM-4 B C LM NM SM AM GM LF AF R 4 Nm 8 Nm 15 Nm 18 Nm 30 Nm 4 Nm 15 Nm – – – – – 0.8 m2 1.5 m2 3 m2 3.6 m2 6 m2 0.8 m2 3 m2 For dampers Spring return


    Original
    PDF i0028811 i0099805 TR-80060 ENG-93001-93223-04 02-1M polygyr polygyr RWF 32 SM220-SR SM24S Motor Control Center wiring diagram abb SM24-SR90 SM24-SR rwf 61.3 polygyr RWF 1-14 staefa RS

    LM24-5P0

    Abstract: LM24-SR LM24 M00067 staefa SGE24 SGF24 landis and staefa wiring diagram of universal motor M0004
    Text: B C Actuators for heating, ventilation, air-conditioning -CD Product Information Damper actuators LM i0026809 2. LM-4 B C NM SM AM GM LF AF 4 Nm 8 Nm 15 Nm 18 Nm 30 Nm 4 Nm 15 Nm – – – – – 0.8 m2 1.5 m2 3 m2 3.6 m2 6 m2 0.8 m2 3 m2 i0084803 LM For dampers Spring return


    Original
    PDF i0026809 i0084803 LM24-SR LM24-SR ENG-93001-93221-01 LM24-5P0 LM24 M00067 staefa SGE24 SGF24 landis and staefa wiring diagram of universal motor M0004

    Untitled

    Abstract: No abstract text available
    Text: W H I T E P A P E R Choosing Close-Coupled IT Cooling Solutions Smart Strategies for Small to Mid-Size Data Centers Executive Summary As high-density IT equipment becomes the new normal, the amount of heat generated continues to grow substantially – as does the challenge of efficiently cooling


    Original
    PDF

    NM24-SRS

    Abstract: SGF24 NM230 HVAC damper landis and staefa controller AEG motor danfoss ZSD 100 NM24-SR
    Text: B C Actuators for heating, ventilation, air-conditioning -CD Product Information Damper actuators NM i0027811 2. NM-3 B C LM NM SM AM GM LF AF 4 Nm 8 Nm 15 Nm 18 Nm 30 Nm 4 Nm 15 Nm – – – – – 0.8 m2 1.5 m2 3 m2 3.6 m2 6 m2 0.8 m2 3 m2 For dampers Spring return


    Original
    PDF i0027811 i0098805 m0008707 w0009707 ENG-93001-93222-01 m0009807 m0010707 NM24-SRS SGF24 NM230 HVAC damper landis and staefa controller AEG motor danfoss ZSD 100 NM24-SR

    Honeywell M6531A1007

    Abstract: honeywell M7535A1001 TP939B1002 honeywell ml7420a3006 T7412A1018 C7085A1006 MT4-230-NC T7460B1009 Delta Electronics dps 730 T7414A1019
    Text: Field Devices A L L Y O U N E E D I N H VAC C ON TR OL INCLUDED Product Catalog 2013 Documentation on CD QR Codes Actuators 13 Valves linear 33 Valves rotary 86 Frequency inverters 99 Sensors 110 Thermostats 152 Pneumatic Products 162 Miscellaneous 174 Old products


    Original
    PDF 20/38mm Honeywell M6531A1007 honeywell M7535A1001 TP939B1002 honeywell ml7420a3006 T7412A1018 C7085A1006 MT4-230-NC T7460B1009 Delta Electronics dps 730 T7414A1019

    175417

    Abstract: No abstract text available
    Text: National Semiconductor LM45B/LM45C SOT-23 Precision Centigrade Temperature Sensors • Portable Medical Instruments ■ HVAC General Description The LM45 series are precision integrated-circuit tempera­ ture sensors, whose output voltage is linearly proportional to


    OCR Scan
    PDF LM45B/LM45C LM45B/LM45C OT-23 175417