gas detector
Abstract: gas leakage alarm gas leakage alarm applications BXC-02 gas detector datasheet gas detectors ICs gas leakage of gas leakage alarm
Text: BXC-02 Inflammable Gas Detector Applications ◆ Natural gas leakage in urban area ◆ Inflammable gas leakage in petrochemical industry ◆ Inflammable gas leakage in nautical industry ◆ Inflammable gas leakage in gas station, storage tanks & vessels ◆ Inflammable gas leakage in fire fighting
|
Original
|
BXC-02
BXC-02
CNEx02
gas detector
gas leakage alarm
gas leakage alarm applications
gas detector datasheet
gas detectors ICs
gas leakage
of gas leakage alarm
|
PDF
|
Untitled
Abstract: No abstract text available
Text: PRODUCT INFORMATION GAS 86xyB May/2012 GAS 86xyB Digital Gas Sensor Platform Micronas’ multi-parametric sensor platform GAS 86xyB includes two CCFET Capacitive-Coupled Field-Effect Transistor gas detection devices, a temperature sensor, and a relative humidity sensor. Each sensor
|
Original
|
86xyB
May/2012
86xyB
PI000141
002EN
D-79108
D-79008
|
PDF
|
SL1411A
Abstract: No abstract text available
Text: Gas Plasma Arrester GDT Products Heavy Duty Delta Range > SL1411A Series RoHS Pb SL1411A Series Two-terminal Gas Plasma Arrester Description The Greentube SL1411A (Delta) Series Gas Plasma Arrester (improved gas discharge tube (GDT) features is a
|
Original
|
SL1411A
SL1411A
00V/s
/series/SL1411A
SL1411AxxxA
SL1411
SL1411AxxxSM
SL1411AxxxC
|
PDF
|
GDT application
Abstract: marking code SM diode SL1411A DELTA SURGE SUPPRESSOR SL1411A Series SL1411 pb gas tube SL1411A090 plasma protection SL1411A075
Text: Gas Plasma Arrester GDT Products Heavy Duty Delta Range > SL1411A Series RoHS Pb SL1411A Series Two-terminal Gas Plasma Arrester Description The Greentube SL1411A (Delta) Series Gas Plasma Arrester (improved gas discharge tube (GDT) features is a
|
Original
|
SL1411A
SL1411A
00V/s
/series/SL1411A
SL1411AxxxA
SL1411
SL1411AxxxSM
SL1411AxxxC
GDT application
marking code SM diode
DELTA SURGE SUPPRESSOR
SL1411A Series
pb gas tube
SL1411A090
plasma protection
SL1411A075
|
PDF
|
4 pin gas sensor
Abstract: figaro TGS 2611 methane gas sensor TGS2611-E00 ethanol gas sensor TGS2611-C00 TGS 2611 methane gas detector gas detector engineering figaro TGS2611
Text: FIGARO PRODUCT INFORMATION TGS 2611 - for the detection of Methane Features: Applications: * Low power consumption * High sensitivity to methane * Long life and low cost * Uses simple electrical circuit * Domestic gas alarms * Portable gas detectors * Gas leak detector for gas appliances
|
Original
|
TGS2611
5000ppm
4 pin gas sensor
figaro TGS 2611
methane gas sensor
TGS2611-E00
ethanol gas sensor
TGS2611-C00
TGS 2611
methane gas detector
gas detector engineering
figaro TGS2611
|
PDF
|
NDIR gas analyzer cell
Abstract: Non-Dispersive InfraRed (NDIR) absorption sensor NDIR gas sensor RS232 for modulator EL6010 so2 Gas sensor ndir magnos106 EL6010-Uras infrared gas analyzer Non-Dispersive InfraRed NDIR absorption sensor
Text: EasyLine Continuous Gas Analyzers Model EL6010 Gas Analyzer in Category 2G Operator’s Manual 42/24 30 EN Rev. 3 EasyLine Continuous Gas Analyzers Model EL6010 Gas Analyzer in Category 2G Operator’s Manual Publication No. 42/24 30 EN Rev. 3 Edition June 2007
|
Original
|
EL6010
EL6010
NDIR gas analyzer cell
Non-Dispersive InfraRed (NDIR) absorption sensor
NDIR gas sensor
RS232 for modulator
so2 Gas sensor ndir
magnos106
EL6010-Uras
infrared gas analyzer
Non-Dispersive InfraRed NDIR absorption sensor
|
PDF
|
transorb
Abstract: transorb diode transorb 24v transorb capacitance transorb diode 400 w 150DC overvoltage shunt suppressor
Text: Overvoltage Protection Gas-filled surge arresters Gas Arresters/Diodes Gas arresters consist of a ceramic or glass tube designed with a specific diameter and length depending on the operating voltage. The cylinder is sealed with an inert gas inside and electrode caps and connection wire on
|
OCR Scan
|
150DC
230DC
350DC
470DC
360DC
470DC
600DC
115AC
transorb
transorb diode
transorb 24v
transorb capacitance
transorb diode 400 w
overvoltage shunt suppressor
|
PDF
|
gas discharge SL1411A
Abstract: PE-80 SL1411A SL1411A075 SL1411A090 SL1411A230 T-940
Text: Gas Discharge Tubes Heavy Duty Delta Range RoHS SL1411A Series Two-terminal Gas Plasma Arrester Pb The Greentube SL1411A Delta Series Gas Plasma Arrester (improved gas discharge tube (GDT) features is a highperformance transient voltage suppressor designed for heavyduty protection of telecom and industrial equipment.
|
Original
|
SL1411A
SL1411A
90VDC
gas discharge SL1411A
PE-80
SL1411A075
SL1411A090
SL1411A230
T-940
|
PDF
|
MQ4 GAS SENSOR
Abstract: water conductivity meter drive circuit water conductivity meter circuit CH4 gas detector lpg gas detector LPG GAS SENSOR working mq4 sensor Gas Detector MQ-4 MQ 5 gas sensor AND PIN CONFIGURATION
Text: Henan Hanwei Electronics Co., Ltd www.hwsensor.com MQ-4 Semiconductor Sensor for Natural Gas Sensitive material of MQ-4 gas sensor is SnO2, which with lower conductivity in clean air. When the target combustible gas exist, The sensor’s conductivity is more higher along with the gas concentration
|
Original
|
temperature100
temperature250
MQ4 GAS SENSOR
water conductivity meter drive circuit
water conductivity meter circuit
CH4 gas detector
lpg gas detector
LPG GAS SENSOR working
mq4 sensor
Gas Detector
MQ-4
MQ 5 gas sensor AND PIN CONFIGURATION
|
PDF
|
VDE0171
Abstract: EN50039 pellistor BS4683 UL698 EN50018 EN-50014 BS5345 UL913 chlorine dioxide
Text: Data Pack A Issued July 1998 302-1016 Portable Gas Monitors Data Sheet What is Gas? Figure 1 The name gas comes from the word chaos which neatly summarises the main feature of the simplest state of matter. A gas is a swarm of particles moving randomly and chaotically;
|
Original
|
|
PDF
|
gas leakage alarm
Abstract: of gas leakage alarm Buzzer 12v alarm 5. buzzer alarm circuit Buzzer 12v SG-021
Text: Natural Gas Alarm Product Information Model: SG-021 Description: Model SG-021 Rated Voltage AC220V/50Hz±10% or DC10-14V Object Gas Alarm Concentration Consumed Power Alarm Output Contact Capacity Operating Temperature Operating Humidity Application Natural Gas
|
Original
|
SG-021
AC220V/50Hz
DC10-14V
DC24V/1A
gas leakage alarm
of gas leakage alarm
Buzzer 12v
alarm
5. buzzer alarm
circuit Buzzer 12v
SG-021
|
PDF
|
MQ 6 gas sensor AND PIN CONFIGURATION
Abstract: mq5 sensor MQ 2 gas sensor AND PIN CONFIGURATION MQ 5 Smoke sensor MQ 5 gas sensor AND PIN CONFIGURATION MQ 06 SENSOR "GAS SENSOR" MQ 5 LPG GAS SENSOR MQ 6 gas sensor PIN CONFIGURATION MQ 6 gas sensor
Text: HANWEI ELECTRONICS CO.,LTD TECHNICAL MQ-5 http://www.hwsensor.com DATA MQ-5 GAS SENSOR FEATURES * High sensitivity to LPG, natural gas , town gas * Small sensitivity to alcohol, smoke. * Fast response . * Stable and long life * Simple drive circuit APPLICATION
|
Original
|
1000ppm
MQ 6 gas sensor AND PIN CONFIGURATION
mq5 sensor
MQ 2 gas sensor AND PIN CONFIGURATION
MQ 5 Smoke sensor
MQ 5 gas sensor AND PIN CONFIGURATION
MQ 06 SENSOR
"GAS SENSOR" MQ 5
LPG GAS SENSOR
MQ 6 gas sensor PIN CONFIGURATION
MQ 6 gas sensor
|
PDF
|
MQ 6 gas sensor AND PIN CONFIGURATION
Abstract: LPG GAS SENSOR mq5 sensor lpg gas detector MQ 2 gas sensor AND PIN CONFIGURATION Gas Detector MQ 5 gas sensor AND PIN CONFIGURATION MQ 6 gas sensor lpg leakage detector MQ 6 gas leakage alarm
Text: HANWEI ELECTRONICS CO.,LTD MQ-5 http://www.hwsensor.com TECHNICAL DATA MQ-5 GAS SENSOR FEATURES * High sensitivity to LPG, natural gas , town gas * Small sensitivity to alcohol, smoke. * Fast response . * Stable and long life * Simple drive circuit APPLICATION
|
Original
|
1000ppm
MQ 6 gas sensor AND PIN CONFIGURATION
LPG GAS SENSOR
mq5 sensor
lpg gas detector
MQ 2 gas sensor AND PIN CONFIGURATION
Gas Detector
MQ 5 gas sensor AND PIN CONFIGURATION
MQ 6 gas sensor
lpg leakage detector
MQ 6 gas leakage alarm
|
PDF
|
Untitled
Abstract: No abstract text available
Text: FLC10 Fire lighter circuit Datasheet − production data Description The FLC10 series has been especially developed for high power capacitance discharge operation. The main applications are gas lighters or ignitors such as cookers / gas boilers / gas hobs.
|
Original
|
FLC10
FLC10
DocID5202
|
PDF
|
|
LPG GAS SENSOR
Abstract: MQ 6 gas sensor AND PIN CONFIGURATION mq5 sensor lpg gas detector MQ 2 gas sensor AND PIN CONFIGURATION LPG GAS SENSOR data sheet MQ 5 gas sensor AND PIN CONFIGURATION MQ 6 gas sensor MQ 6 SENSOR MQ 5 Smoke sensor
Text: HANWEI ELECTRONICS CO.,LTD TECHNICAL MQ-5 http://www.hwsensor.com DATA MQ-5 GAS SENSOR FEATURES * High sensitivity to LPG, natural gas , town gas * Small sensitivity to alcohol, smoke. * Fast response . * Stable and long life * Simple drive circuit APPLICATION
|
Original
|
800mw
1000ppm
LPG GAS SENSOR
MQ 6 gas sensor AND PIN CONFIGURATION
mq5 sensor
lpg gas detector
MQ 2 gas sensor AND PIN CONFIGURATION
LPG GAS SENSOR data sheet
MQ 5 gas sensor AND PIN CONFIGURATION
MQ 6 gas sensor
MQ 6 SENSOR
MQ 5 Smoke sensor
|
PDF
|
D6F-01N2-000
Abstract: D6F-05N2-000
Text: MEMS Flow Sensor D6F-01N/02L/05N High Accuracy Mass Flow Sensing for Natural Gas and Propane Applications • Small size • Fast response • Applicable to air, non-corrosive gas, natural gas and propane • Applications include: analysis apparatus, combustion control
|
Original
|
D6F-01N/02L/05N
D6F-01N2-000
D6F-02L2-000
D6F-05N2-000
J01C-E-01
D6F-01N2-000
D6F-05N2-000
|
PDF
|
Untitled
Abstract: No abstract text available
Text: FLC01 Fire lighter circuit Datasheet − production data Description The FLC01 series has been especially developed for capacitance discharge operation. The main applications are gas lighters or ignitors such as cookers / gas boilers / gas hobs. TA B TA B
|
Original
|
FLC01
FLC01
DocID3616
|
PDF
|
MEMS flow sensor
Abstract: "Flow Sensor" D6F-01N2-000 D6F-05N2-000
Text: MEMS Flow Sensor D6F-01N, -02L, -05N High Accuracy Mass Flow Sensing for Natural Gas and Propane Applications • Small size • Fast response • Applicable to air, non-corrosive gas, natural gas and propane • Applications include: analysis apparatus, combustion control
|
Original
|
D6F-01N,
D6F-01N2-000
D6F-02L2-000
D6F-05N2-000
X305-E-1
MEMS flow sensor
"Flow Sensor"
D6F-01N2-000
D6F-05N2-000
|
PDF
|
motor operated valve
Abstract: water heater water level control circuit diagram water level control block diagram motor operated valve for gas HT46R48 water heater block diagram igniter transformer circuit diagram water level sensor water level controller circuit diagram
Text: Using the HT46R48 in a Gas Water Heater Application Using the HT46R48 in a Gas Water Heater Application D/N: HA0134E Introduction This forced exhaust gas water heater uses a Holtek HT46R48 MCU as the controlling device. It includes many safety features during fault conditions, such as flame
|
Original
|
HT46R48
HA0134E
motor operated valve
water heater
water level control circuit diagram
water level control block diagram
motor operated valve for gas
water heater block diagram
igniter transformer
circuit diagram water level sensor
water level controller circuit diagram
|
PDF
|
Untitled
Abstract: No abstract text available
Text: CONTACT ELECTRICAL CHARACTERISTICS TIGER EYE CONTACT TESTING A. Gas Tight 1. Purpose - To evaluate the integrity of the contact interface by assessment of the gas tight characteristics of the contacting surfaces. The gas tight characteristic is the ability of contacting surfaces to prevent harsh environment from penetrating between them
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: CONTACT ELECTRICAL CHARACTERISTICS BOX CONTACT TESTING A. Gas Tight 1.Purpose - To evaluate the integrity of the contact interface by assessment of the gas tight characteristics of the contacting surfaces. The gas tight characteristic is the ability of contacting surfaces to prevent harsh environment from penetrating between
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: CONTACT ELECTRICAL CHARACTERISTICS DUAL WIPE CONTACT TESTING A. Gas Tight 1. Purpose - To evaluate the integrity of the contact interface by assessment of the gas tight characteristics of the contacting surfaces. The gas tight characteristic is the ability of contacting surfaces to prevent harsh environment from penetrating between them
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: CONTACT ELECTRICAL CHARACTERISTICS TIGER CLAW CONTACT TESTING A. Gas Tight 1. Purpose - To evaluate the integrity of the contact interface by assessment of the gas tight characteristics of the contacting surfaces. The gas tight characteristic is the ability of contacting surfaces to prevent harsh environment from penetrating between them
|
Original
|
|
PDF
|
LPG GAS SENSOR
Abstract: HS-133 LPG GAS SENSOR application IC4-H10 isobutane gas sensor iC4H10 i-C4H10 hs 133 SUS316 PROPANE sensor
Text: LPG gas sensor HS-133 specifications ^Characteristics 1.1 High sensitive, good selectivity to fume and alcohol. 1.2 Long period using life and reliable stability. 2. Application 2.1 Gas leakage detecting in family and industry 2.2 Suitable for detecting equipments of LPG> isobutane> propane> methane.
|
OCR Scan
|
HS-133
SUS316)
300ppm-2000ppm
i-C4H10
LPG GAS SENSOR
LPG GAS SENSOR application
IC4-H10
isobutane gas sensor
iC4H10
i-C4H10
hs 133
SUS316
PROPANE sensor
|
PDF
|