Abstract: NPZ100-EX NPJ460-NO NPJ130-NO NFE100-NE 180884 NFE100-NE NGJ100-NE foundation field bus 877004 M12 connector 4pin
Text: Data Sheet 10/63-6.60 EN • FOUNDATION Fieldbus-H1 – Junctions – Connectors – Accessories FOUNDATION Fieldbus Junctions, Connectors, Accessories FOUNDATION Fieldbus Junctions, Connectors, Accessories FOUNDATION Fieldbus-H1 10/63-6.60 EN The FOUNDATION Fieldbus-H1 T-Connectors are available as Standard and Ex Haz. version. They are used for coupling
|
Original
|
3KXN622100L0002
3KXN622100L0004
3KXN622100L0006
kema 01 atex 1058
NPZ100-EX
NPJ460-NO
NPJ130-NO
NFE100-NE 180884
NFE100-NE
NGJ100-NE
foundation field bus
877004
M12 connector 4pin
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Data Sheet 10/63-6.67-EN Rev. D FOUNDATION fieldbus cable FOUNDATION fielbus-H1 cable — Non-Ex Hazardous applications — Ex (Hazardous) applications FOUNDATION fieldbus cable FOUNDATION fieldbus-H1 cable M10771 NFC080-NO, NFC080-EX Application NFC150-NO, NFC150-EX
|
Original
|
67-EN
M10771
NFC080-NO,
NFC080-EX
NFC150-NO,
NFC150-EX
NFC250-NO,
NFC250-EX
FB-02YS
M10772
|
PDF
|
Untitled
Abstract: No abstract text available
Text: FOUNDATION fieldbus Diagnostic module DPC-49-DU The DPC system Diagnostic Power Conditioner is a power supply system for the installation of FOUNDATION™ fieldbus H1 segments. It provides extensive diagnostic options for monitoring FOUNDATION™ fieldbus
|
Original
|
DPC-49-DU
2013-07-13T18
whichPC-49-DU
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: FOUNDATION fieldbus Diagnostic module DPC-49-ADU The DPC system Diagnostic Power Conditioner is a power supply system for the installation of FOUNDATION™ fieldbus H1 segments. It provides extensive diagnostic options for monitoring FOUNDATION™ fieldbus
|
Original
|
DPC-49-ADU
DPC-49-IPS1
DPC-49-ADU
DPC-49-DU
DPC-49-HSEFD/24VDC
2013-07-13T18
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: FOUNDATION fieldbus Power supply module DPC-49-IPS1 The DPC system Diagnostic Power Conditioner is a power supply system for the installation of FOUNDATION™ fieldbus H1 segments. It provides extensive diagnostic options for monitoring FOUNDATION™ fieldbus
|
Original
|
DPC-49-IPS1
DPC-49-IPS1
DPC-49-ADU
DPC-49-DU
DPC-49-HSEFD/24VDC
850mA
2013-07-13T18
D-45472
|
PDF
|
ControlLogix Foundation Fieldbus
Abstract: 1757-FFLDC2 1757-FFLDC4 1757-FFLDC Factorytalk view mark S88 ControlLogix 9308-RSFB1024ENE 1757-FFLD 1757
Text: Foundation Fieldbus Linking Device for ControlNet and RSFieldbus Software Technical Data Combine the Power of PlantPAx with Foundation Fieldbus Technology The Rockwell Automaton PlantPAx process automation system provides a single plant-wide control and information platform while the Foundation
|
Original
|
1757-TD004B-EN-P
1757-TD004A-EN-P-November
ControlLogix Foundation Fieldbus
1757-FFLDC2
1757-FFLDC4
1757-FFLDC
Factorytalk view
mark S88
ControlLogix
9308-RSFB1024ENE
1757-FFLD
1757
|
PDF
|
Untitled
Abstract: No abstract text available
Text: FOUNDATION fieldbus Backplane for the DPC system DPC-49-4RMB The DPC system Diagnostic Power Conditioner is a power supply system for the installation of FOUNDATION™ fieldbus H1 segments. It provides extensive diagnostic options for monitoring FOUNDATION™ fieldbus
|
Original
|
DPC-49-4RMB
DPC-49-IPS1
2013-07-13T18
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: FOUNDATION fieldbus HSE field device DPC-49-HSEFD/24VDC The DPC system Diagnostic Power Conditioner is a power supply system for the installation of FOUNDATION™ fieldbus H1 segments. It provides extensive diagnostic options for monitoring FOUNDATION™ fieldbus
|
Original
|
DPC-49-HSEFD/24VDC
DPC-49-IPS1
2013-07-13T18
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: FOUNDATION fieldbus Backplane for the DPC system DPC-49-4RMB/SY The DPC system Diagnostic Power Conditioner is a power supply system for the installation of FOUNDATION™ fieldbus H1 segments. It provides extensive diagnostic options for monitoring FOUNDATION™ fieldbus
|
Original
|
DPC-49-4RMB/SY
DPC-49-IPS1
DPC-49-ADU
DPC-49-DU
DPC-49-HSEFD/24VDC
2013-07-13T18
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: FOUNDATION fieldbus Backplane for the DPC system DPC-49-4RMB/YO The DPC system Diagnostic Power Conditioner is a power supply system for the installation of FOUNDATION™ fieldbus H1 segments. It provides extensive diagnostic options for monitoring FOUNDATION™ fieldbus
|
Original
|
DPC-49-4RMB/YO
DPC-49-IPS1
DPC-49-ADU
DPC-49-DU
DPC-49-HSEFD/24VDC
2013-07-13T18
D-45472
|
PDF
|
ABB flowmeter COPA-XE
Abstract: Yamatake ST3000 smart transmitter coriolis mass flow meter FMR130 ABB pressure transmitter series 2600T LD800HSE DVC5010f Foxboro IMT25 PMD230 PMD235
Text: IndustrialIT System 800xA Device Management FOUNDATION Fieldbus Data Sheet Integrated FOUNDATION Fieldbus Devices Revision: September 2010 Category Vendor Device Type 1 Application Device Description Device Type / Device Revision, DD Revision) Actuator AUMA
|
Original
|
800xA
0x01F8
0x0100
0x4D58
0x0001
TB82EC
0x0051
TB82PH
0x0050
ABB flowmeter COPA-XE
Yamatake ST3000 smart transmitter
coriolis mass flow meter
FMR130
ABB pressure transmitter series 2600T
LD800HSE
DVC5010f
Foxboro IMT25
PMD230
PMD235
|
PDF
|
fieldbus
Abstract: No abstract text available
Text: FOUNDATION Fieldbus Monitor Software FF Monitor Features 32-bit Windows 95 application for FOUNDATION Fieldbus monitoring Display live and logged data Fully configurable multiwindow display Flexible fieldbus packet filtering Bus statistics Easy-to-use menu-driven interface
|
Original
|
32-bit
fieldbus
|
PDF
|
FIO-100
Abstract: t0433 foundation field bus 810E 514.4 MIL-STD-810E 501.3 46D1 FF-941
Text: Data Sheet Fieldbus Linking Device FIO-100 TC03112A Description The FIO-100 block provides an intelligent communications gateway between a host system and FOUNDATION Fieldbus FF compatible devices. The block is a Foundation Fieldbus registered high-speed Ethernet™ linking device for up to four independent Foundation Fieldbus H1 segments. When coupled with a host system the pair create an exciting control system solution that
|
Original
|
FIO-100
TC03112A
FIO-100
D-68167
WBPEEUD270002B0
Aug2001
SE-721
t0433
foundation field bus
810E 514.4
MIL-STD-810E 501.3
46D1
FF-941
|
PDF
|
1757-FFLD
Abstract: 1757-FFLD4 1757-FFLD2 1757FFLD2 Factorytalk view 9308-RSFB64ENE ControlLogix Foundation Fieldbus logix 5000 rockwell RSLOGIX 5000 Foundation Fieldbus
Text: Foundation Fieldbus Linking Device and RSFieldbus Software Technical Data Combine the Power of PlantPAx with Foundation Fieldbus Technology The Rockwell Automaton PlantPAx process automation system provides a single plant-wide control and information platform while
|
Original
|
1757-TD003E-EN-P
1757-TD003D-EN-P-December
1757-FFLD
1757-FFLD4
1757-FFLD2
1757FFLD2
Factorytalk view
9308-RSFB64ENE
ControlLogix Foundation Fieldbus
logix 5000
rockwell RSLOGIX 5000
Foundation Fieldbus
|
PDF
|
|
YTZ420
Abstract: 80386EX 777335
Text: FOUNDATION Fieldbus Interfaces for PCMCIA PCMCIA-FBUS, PCMCIA-FBUS/2 Features NI-FBUS Software PCMCIA-FBUS Windows NT Included with board Application Software Overview The PCMCIA-FBUS is a FOUNDATION Fieldbus interface for computers with PC Card PCMCIA slots, especially laptop and
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: FOUNDATION fieldbus IP67 junction box, 4-channel JBBS-49SC-E413/3G The 4-channel Ex junction box JBBS-49SCE413/3G is designed for FOUNDATION™ fieldbus systems. The junction is equipped with an adjustable short-circuit limit. The following max. current
|
Original
|
JBBS-49SC-E413/3G
JBBS-49SCE413/3G
2013-07-13T14
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: FOUNDATION fieldbus IP67 junction box, 6-channel JBBS-49SC-M613/EX The 6-channel Ex junction box JBBS-49SCM613/EX is designed for FOUNDATION™ fieldbus systems. The junction is equipped with an adjustable short-circuit limit. The following max. current
|
Original
|
JBBS-49SC-M613/EX
JBBS-49SCM613/EX
2013-08-15T10
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: FOUNDATION fieldbus IP67 junction box, 6-channel JBBS-49SC-T615/3G The 6-channel Ex junction box JBBS-49SCT615/3G is designed for FOUNDATION™ fieldbus systems. The junction is equipped with an adjustable short-circuit limit. The following max. current
|
Original
|
JBBS-49SC-T615/3G
JBBS-49SCT615/3G
2013-07-13T14
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Accessories for fieldbus systems Flange connector RKFV49 • 7/8" female ■ 1/2’’14 NPT screw-in thread ■ Stainless steel flange housing ■ 4-pole, solderable ■ For use in FOUNDATION fieldbus applications FOUNDATION™ fieldbus connection Type code
|
Original
|
RKFV49
2013-07-13T13
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: FOUNDATION fieldbus IP67 junction box, 6-channel JBBS-49SC-E613/3G The 6-channel Ex junction box JBBS-49SCE613/3G is designed for FOUNDATION™ fieldbus systems. The junction is equipped with an adjustable short-circuit limit. The following max. current
|
Original
|
JBBS-49SC-E613/3G
JBBS-49SCE613/3G
2013-07-13T14
D-45472
|
PDF
|
DB9 Male
Abstract: ti101 80386EX YTZ420 db9 dimensions f-bus connector Foundation Fieldbus
Text: FOUNDATION Fieldbus Interfaces AT-FBUS Series, PCMCIA-FBUS Series AT-FBUS Series, PCMCIA-FBUS Series H1 31.25 kb/s interface 1 or 2 ports Intel 80386EX processor Yamaha YTZ420 fieldbus interface chip Embedded FOUNDATION Fieldbus communication-stack software
|
Original
|
80386EX
YTZ420
DB9 Male
ti101
db9 dimensions
f-bus connector
Foundation Fieldbus
|
PDF
|
LD800HSE
Abstract: CI860 800HSE CI860 HSE ABB 800xA 9 pole sub-d male
Text: FieldIT FOUNDATION Fieldbus Linking Device LD 800HSE Data Sheet Benefits The FOUNDATION Fieldbus Linking Device LD 800HSE is designed according to class 42c of the HSE profile, therefore providing the following functions: • Configuration of the connected H1
|
Original
|
800HSE
800HSE
3BDD011675R0401
LD800HSE
CI860
CI860 HSE
ABB 800xA
9 pole sub-d male
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Accessories for fieldbus systems T-junction RSCV-2RKCV49 • ■ T-piece, 4-pin, with M12 stainless steel flange connections For use in PROFIBUS-PA and FOUNDATION fieldbus applications FOUNDATION™ fieldbus connection Type code Ident no. RSCV-2RKCV49 6603431
|
Original
|
RSCV-2RKCV49
2013-07-13T13
D-45472
|
PDF
|
6fai
Abstract: ATT60 sensor S900 FF-891 eu100 IN128 0x80020AF0 Yamatake
Text: No. SS2-ATT10F-0001 Device Description and Capability File for Advanced Temperature Transmitter with FOUNDATION fieldbus Model ATT60/70 OVERVIEW The model ATT with FOUNDATION™ fieldbus is an accurate, stable, and reliable temperature transmitter, which fully complies with the
|
Original
|
SS2-ATT10F-0001
ATT60/70
25kbps
0x00000000000000
0x00000000
6fai
ATT60
sensor
S900
FF-891
eu100
IN128
0x80020AF0
Yamatake
|
PDF
|