FLOW SENSOR WATER Search Results
FLOW SENSOR WATER Result Highlights (5)
Part | ECAD Model | Manufacturer | Description | Download | Buy |
---|---|---|---|---|---|
MRUS74SK-001 | Murata Manufacturing Co Ltd | Magnetic Sensor |
![]() |
||
MRUS74SD-001 | Murata Manufacturing Co Ltd | Magnetic Sensor |
![]() |
||
MRMS581P | Murata Manufacturing Co Ltd | Magnetic Sensor |
![]() |
||
MRMS591P | Murata Manufacturing Co Ltd | Magnetic Sensor |
![]() |
||
MRMS791B | Murata Manufacturing Co Ltd | Magnetic Sensor |
![]() |
FLOW SENSOR WATER Datasheets Context Search
Catalog Datasheet | Type | Document Tags | |
---|---|---|---|
Contextual Info: Water Flow sensor Water flow sensor consists of a plastic valve body, a water rotor, and a hall-effect sensor. When water flows through the rotor, rotor rolls. Its speed changes with different rate of flow. The hall-effect sensor outputs the corresponding pulse |
Original |
V-24V 10L/min) | |
D6F-W
Abstract: Omron
|
Original |
D6F-W01A1 D6F-W10A1 D6F-W04A1 A184-E1-02 D6F-W Omron | |
Contextual Info: D6F-W MEMS Flow Rate Sensor A Compact Sensor That Uses OMRON’s Unique Flow Path Structure for High-performance Flow Rate Measurement. • Anti-dust performance enhanced by OMRON’s unique three-dimensional flow path structure. • High accuracy of ±5% FS. |
Original |
D6F-W01A1 D6F-W04A1 D6F-W10A1 A184-E1-02 | |
Contextual Info: Flow sensor Immersion sensor with integrated processor FCS-68A4-AP8X-H1141/D003 • Flow sensor for liquid media ■ Calorimetric principle ■ Adjustment via potentiometer ■ LED band ■ Sensor, stainless steel A4 1.4404 ■ Mechanical Connection: Varivent |
Original |
FCS-68A4-AP8X-H1141/D003 150cm/s 2013-07-13T18 D-45472 | |
Contextual Info: Flow sensor Immersion sensor with integrated processor FCS-50A4-AP8X-H1141/D014 • Flow sensor for liquid media ■ Calorimetric principle ■ Adjustment via potentiometer ■ LED band ■ Sensor, stainless steel A4 1.4404 ■ Mechanical Connection: Tri-Clamp |
Original |
FCS-50A4-AP8X-H1141/D014 150cm/s 2013-07-13T18 D-45472 | |
Contextual Info: Flow sensor Immersion sensor without integrated processor FCS-G1/2A4-NA/L120 • Flow sensor for liquid media ■ Calorimetric principle ■ ■ Adjustment via potentiometer on processor Status indicated via LED chain on signal processor ■ Sensor length 120 mm |
Original |
FCS-G1/2A4-NA/L120 150cm/s 2013-07-13T18 D-45472 | |
Contextual Info: Flow sensor Immersion sensor without integrated processor FCS-G1/2HB2-NA • Flow sensor for liquid media ■ Calorimetric principle ■ ■ Adjustment via potentiometer on processor Status indicated via LED chain on signal processor ■ Sensor made of Hastelloy B2 |
Original |
150cm/s 2013-07-13T18 D-45472 | |
Contextual Info: Flow sensor Immersion sensor with integrated processor FCS-G1/2A4-AP8X-H1141/D030 • Flow sensor for liquid media ■ Calorimetric principle ■ Adjustment via potentiometer ■ LED band ■ FCS-G1/2A4-AP8X-H1141/D030 6870019 Operating range water Oil operating range |
Original |
FCS-G1/2A4-AP8X-H1141/D030 150cm/s 2013-07-13T18 D-45472 | |
Contextual Info: Flow sensor Immersion sensor without integrated processor FCS-N1/2T-NA • Flow sensor for liquid media ■ Calorimetric principle ■ ■ Adjustment via potentiometer on processor Status indicated via LED chain on signal processor ■ Sensor made of PTFE |
Original |
70cm/s 2013-07-13T18 D-45472 | |
Contextual Info: Flow sensor Immersion sensor without integrated processor FCS-50A4-NA/D014 • Flow sensor for liquid media ■ Calorimetric principle ■ ■ Type code Ident no. FCS-50A4-NA/D014 6872009 Operating range water Oil operating range Stand-by time Switch-on time |
Original |
FCS-50A4-NA/D014 prob-13T18 150cm/s D-45472 | |
Contextual Info: Flow sensor Immersion sensor without integrated processor FCS-DN25A4-NA/D100 • Flow sensor for liquid media ■ Calorimetric principle ■ ■ ■ ■ Type code Ident no. FCS-DN25A4-NA/D100 6872017 Operating range water Oil operating range Stand-by time |
Original |
FCS-DN25A4-NA/D100 150cm/s 2013-07-13T18 D-45472 | |
Contextual Info: Flow sensor Immersion sensor without integrated processor FCS-G1/2A4-NA/L080 • Flow sensor for liquid media ■ Calorimetric principle ■ ■ Adjustment via potentiometer on processor Status indicated via LED chain on signal processor ■ Sensor length 80 mm |
Original |
FCS-G1/2A4-NA/L080 150cm/s 2013-07-13T18 D-45472 | |
Contextual Info: Flow sensor Immersion sensor without integrated processor FCS-GL1/2T-NA • Flow sensor for liquid media ■ Calorimetric principle ■ ■ Adjustment via potentiometer on processor Status indicated via LED chain on signal processor ■ Sensor made of PTFE |
Original |
70cm/s 2013-07-13T18 D-45472 | |
Contextual Info: Flow sensor Immersion sensor without integrated processor FCS-GL3/4T-NA • Flow sensor for liquid media ■ Calorimetric principle ■ ■ Adjustment via potentiometer on processor Status indicated via LED chain on signal processor ■ Sensor made of PTFE |
Original |
70cm/s 2013-07-13T18 D-45472 | |
|
|||
Contextual Info: Flow sensor Immersion sensor without integrated processor FCS-G1/2HC22-NA • Flow sensor for liquid media ■ Calorimetric principle ■ ■ Adjustment via potentiometer on processor Status indicated via LED chain on signal processor ■ Sensor made of Hastelloy C22 |
Original |
FCS-G1/2HC22-NA 150cm/s 2013-07-13T18 D-45472 | |
Contextual Info: Flow sensor Immersion sensor without integrated processor FCS-G1/4T-NA • Flow sensor for liquid media ■ Calorimetric principle ■ ■ Adjustment via potentiometer on processor Status indicated via LED chain on signal processor ■ Sensor made of PTFE |
Original |
70cm/s 2013-07-13T18 D-45472 | |
Contextual Info: Flow sensor Immersion sensor without integrated processor FCS-G1/2A4-NA/L200 • Flow sensor for liquid media ■ Calorimetric principle ■ ■ Adjustment via potentiometer on processor Status indicated via LED chain on signal processor ■ Sensor length 200 mm |
Original |
FCS-G1/2A4-NA/L200 150cm/s 2013-07-13T18 D-45472 | |
Contextual Info: Flow sensor Immersion sensor without integrated processor FCS-G1/2HB2-NA-H1141 • Flow sensor for liquid media ■ Calorimetric principle ■ ■ Adjustment via potentiometer on processor Status indicated via LED chain on signal processor ■ Sensor made of Hastelloy B2 |
Original |
FCS-G1/2HB2-NA-H1141 150cm/s 2013-07-13T18 D-45472 | |
Contextual Info: Flow sensor Immersion sensor without integrated processor FCS-G1/2A4-NA-H1141/L120 • Flow sensor for liquid media ■ Calorimetric principle ■ ■ Adjustment via potentiometer on processor Status indicated via LED chain on signal processor ■ Sensor length 120 mm |
Original |
FCS-G1/2A4-NA-H1141/L120 150cm/s 2013-07-13T18 D-45472 | |
Contextual Info: Flow sensor Immersion sensor without integrated processor FCS-G1/2HC4-NA-H1141 • Flow sensor for liquid media ■ Calorimetric principle ■ ■ Adjustment via potentiometer on processor Status indicated via LED chain on signal processor ■ Sensor made of Hastelloy C4 |
Original |
FCS-G1/2HC4-NA-H1141 150cm/s 2013-07-13T18 D-45472 | |
Contextual Info: Flow sensor Immersion sensor without integrated processor FCS-G1/2A4-NA-H1141/L200 • Flow sensor for liquid media ■ Calorimetric principle ■ ■ Adjustment via potentiometer on processor Status indicated via LED chain on signal processor ■ Sensor length 200 mm |
Original |
FCS-G1/2A4-NA-H1141/L200 150cm/s 2013-07-13T18 D-45472 | |
Contextual Info: PADDLEWHEEL FLOW SENSOR SYSTEMS Model FP7000 $ 200 MADE IN USA ߜ Very Economical ߜ Wide Chemical Compatibility ߜ High Level Pulse Output - No Amplifier Needed PADDLEWHEEL SENSOR LOCKNUT FLOW Shown Smaller Than Actual Size OMEGA FP7000 paddlewheel flow |
Original |
FP7000 FP7000 FPW-15 FP7007 FP7010 FP7012 FP7015 FP7020 FP7025 | |
Contextual Info: Flow sensor Immersion sensor without integrated processor FCS-G1/2A4-NA-H1141/L080 • Flow sensor for liquid media ■ Calorimetric principle ■ ■ Adjustment via potentiometer on processor Status indicated via LED chain on signal processor ■ Sensor length 80 mm |
Original |
FCS-G1/2A4-NA-H1141/L080 150cm/s 2013-07-13T18 D-45472 | |
Contextual Info: Remote Systems Machinery Protection Flow Sensors • Sensor does not impede media flow • Totally solid-state— no mechanical parts to wear out • Monitors both flow and temperature of media • Rugged, stainless steel sensor Special Application Solutions |
Original |
300mA 1-800-NAMTECH |