ABB AO2020
Abstract: uras26 gas module sensor abb ao2040 Magnos206 Uras26 AO2000 ABB AO2000 AO2040 Caldos25 AO2020 AO2040
Text: Advance Optima Continuous Gas Analyzers AO2000 Series with Uras26, Magnos206, Caldos25, Caldos27 Designed per Category 3G for Measurement of Flammable Gases “Safety Concept” and Non flammable Gases Supplementary Operator’s Manual 42/24 14 EN Rev. 3
|
Original
|
AO2000
Uras26,
Magnos206,
Caldos25,
Caldos27
Caldos27,
Magnos206
Uras26
ABB AO2020
uras26 gas module sensor
abb ao2040
Magnos206
Uras26
ABB AO2000 AO2040
Caldos25
AO2020
AO2040
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Zareba Sensepoint Pro Comprehensive monitoring of flammable, toxic and oxygen gas hazards in potentially explosive atmospheres Sensepoint Pro One-Stop Shop • • • Flammable, toxic and oxygen versions available Suitable for indoor or outdoor use IP65 as standard
|
Original
|
DS0328
|
PDF
|
D2TW600
Abstract: D2TW600VC class 1 div 2 relay ETW401 relay ul 1604 ETC232 nec reed relay door bell telephone relay RS-470
Text: D2TW600 Telephone for Hazardous Areas Applications: These single-line, fully functional electronic telephones are used: • For communication in locations which may be hazardous due to the presence of flammable gases or vapors Division 2 , and/or combustible dusts or fibers
|
Original
|
D2TW600
115VAC
ETC232
ETW40
D2TW600
D2TW600VC
class 1 div 2 relay
ETW401
relay ul 1604
ETC232
nec reed relay
door bell
telephone relay
RS-470
|
PDF
|
UL1203
Abstract: EBMBB FD W30361 CROUSE-HINDS RE crouse-hinds 60 Amp EBMBB W30360 W60360 W30361 W60361 enclosure
Text: 2A EBM Disconnect Switches and Enclosures 600 VAC Heavy Duty Applications: EBM series hinged cover disconnect switches are used: • To disconnect motor, lighting and other circuits. • In locations made hazardous by the presence of flammable gases or vapors
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Applications: ENP plugs are used: • With portable electrical equipment such as compressors, tools, lighting systems, and similar devices • In areas made hazardous by the presence of flammable vapors and gases or combustible dusts • Wherever portable electrical equipment is
|
Original
|
ENP5151
ENP6152
ENP5201
ENP6202
|
PDF
|
Untitled
Abstract: No abstract text available
Text: XAL - 53 Description Explosion-Proof Pull Station Applications The KILLARK , XAL-53 fire alarm stations are suitable for use in the following conditions: • Hazardous areas due to the presence of flammable gases or vapors, combustible dusts or easily ignitable
|
Original
|
XAL-53
XAL-53
SBA-10
CS-2506
|
PDF
|
EN60947-3
Abstract: Panasonic circuit breaker IEC61010-1 EN60947-1 EN609473
Text: PRECAUTIONS IN USING Eco-POWER METER Common PRECAUTIONS IN USING Eco-POWER METER (Common) Ⅵ Avoid locations subject to flammable or corrosive gases, excessive dust, oil, vibrations, or excessive shocks. Ⅵ Although the case is made from fireproof resin, do not
|
Original
|
|
PDF
|
PS1200
Abstract: No abstract text available
Text: New Air Checker: Electronic Pressure Switch RoHS [Option] Applicable fluid: Air, Non-corrosive gas, Non-flammable gas PS1000 For Positive Pressure PS1100 Compact/lightweight electronic pressure switch New For Vacuum, Residual Pressure New Easy adjustment of pressure setting trimmer
|
Original
|
PS1000
PS1100
PS1000-R06L
PS1200
KQ2H/L/T/S/Y06-M5
KQ2H/L07-M5
PS1200
|
PDF
|
D2PB1512-20
Abstract: D2PB2524 D2PB1512 D2PB2412 crouse-hinds D2PB D2PB2424 D2PB D2PB2520 D2CB12 D2PB1410
Text: D2PB Division 2 Circuit Breaker Panelboards Factory Sealed, Single & Two-Pole Circuit Breakers Applications: Standard Materials: D2PB panelboards are designed specifically for use: • In Class I, Division 2, Groups C, D hazardous areas where flammable vapors
|
Original
|
|
PDF
|
CALDOS 17
Abstract: CALDOS 15 magnos 16 CALDOS magnos 106 magnos abb caldos 27 uras 14 MAGNOS 17 Caldos 17, Magnos 16, Magnos 17
Text: Explosion Protected Model Descriptions and Design Notes Technical Information 30/24-100-2 EN Table of Contents Page Examples of Applications 4 Part A Descriptions Chapter 1 Chapter 2 Chapter 3 Ex Analyzer Modules for Zone 1 and Zone 2 Flammable Sample Gas
|
Original
|
24-VDC
Con46610
CALDOS 17
CALDOS 15
magnos 16
CALDOS
magnos 106
magnos
abb caldos 27
uras 14
MAGNOS 17
Caldos 17, Magnos 16, Magnos 17
|
PDF
|
ZSE40AF
Abstract: ZSE40A smc zse 40 ISE30A ZSE80F EMERGENCY OFF PUSH BUTTON PIN DETAILS SMC zse40 ISE40A ZSE30 ISE40
Text: 2-Colour Display High Precision Digital Pressure Switch RoHS compliant IP65 compliant Applicable fluid Air, Non-corrosive gas, Non-flammable gas Can copy to up to 10 switches simultaneously. The settings of the master pressure switch source of copy can be copied
|
Original
|
SI-8210
ZSE40AF
ZSE40A
smc zse 40
ISE30A
ZSE80F
EMERGENCY OFF PUSH BUTTON PIN DETAILS
SMC zse40
ISE40A
ZSE30
ISE40
|
PDF
|
koa speer resistors
Abstract: a/KOA RESISTORS
Text: KOA SPEER ELECTRONICS, INC. SS-02 R3 Fixed Ceramic Composition Resistors Type PCF 1. Scope of Application This specification relates to non-flammable coated, insulated type, fixed ceramic resistors type PCF manufactured by KOA T&T Corporation. 2. Rating
|
Original
|
SS-02
koa speer resistors
a/KOA RESISTORS
|
PDF
|
XDT3C15X
Abstract: XDT3B15X
Text: PRODUCT UPDATE Eaton’s Crouse-Hinds Business XDT Series Hazardous Location Transformers Resin Encapsulated Dry-Type Applications: Features and Benefits: Eaton’s Crouse-Hinds Hazardous Location Dry-Type Transformers are designed to operate where volatile flammable liquids or
|
Original
|
enclT3E30X
XDT3B45
XDT3B45X
XDT3C45
XDT3C45X
XDT3F45
XDT3F45X
XDT3D45
XDT3D45X
XDT3E45
XDT3C15X
XDT3B15X
|
PDF
|
EIA-172
Abstract: No abstract text available
Text: KOA SPEER ELECTRONICS, INC. SS-02 R4 AHA 8/30/02 Fixed Ceramic Composition Resistors Type PCF 1. Scope of Application This specification relates to non-flammable coated, insulated type, fixed ceramic resistors type PCF manufactured by KOA T&T Corporation.
|
Original
|
SS-02
UL-94
EIA-172.
EIA-172
|
PDF
|
|
CROUSE-HINDS EPC
Abstract: Cutler-Hammer 6-1-3 EPC813 Cutler-Hammer type m RELAY EPC871 100FB Cutler-Hammer 643 RELAY Cutler-Hammer contactor Cutler-Hammer current transformer integral 32 square d contactor
Text: 1C EPC Combination Line Starters and Enclosures Applications: 1C • For across-the-line starting of polyphase AC induction motors • In locations which are hazardous due to the presence of flammable vapors, gases or highly combustible dusts • In damp, wet or corrosive locations
|
Original
|
15HMCP
EPC871
30HMCP
15HMCP
CROUSE-HINDS EPC
Cutler-Hammer 6-1-3
EPC813
Cutler-Hammer type m RELAY
EPC871
100FB
Cutler-Hammer 643 RELAY
Cutler-Hammer contactor
Cutler-Hammer current transformer
integral 32 square d contactor
|
PDF
|
NMO500S
Abstract: NMO500
Text: Metal Oxide Film Resistors NMO Series FEATURES • NON-FLAMMABLE RESIN INSULATION • HIGH STABILITY AND RELIABILITY • LOW NOISE • LOW COST ALTERNATIVE TO CARBON COMPOSITION AND .WIREWOUND APPLICATIONS • NEW REDUCED SIZES includes all homogeneous materials
|
Original
|
NMO100
NMO500S
NMO500
|
PDF
|
ABB katharometer 6518
Abstract: 6539-960K GALVANOMETER DATA SHEET thermal conductivity detector amplifier C3H60 flow control valve 6539960 C5H12 GALVANOMETER methane
Text: Data Sheet Katharometers SS/6517_4 Series 6517 • Designed for continuous industrial use ■ Long working life ■ Suitable for flammable gases ■ CENELEC certified ATEX – to EExia IIC T4.Tamb –20 to 55°C (–4 to 131°F) ■ Robust – no moving parts
|
Original
|
SS/6517
SS/6517
ABB katharometer 6518
6539-960K
GALVANOMETER DATA SHEET
thermal conductivity detector amplifier
C3H60
flow control valve
6539960
C5H12
GALVANOMETER
methane
|
PDF
|
XH414H IV01E
Abstract: xh414h ms614s MATERIAL SAFETY SHEET SR927W SR421SW XH414H-IV01E MS621F-FL11E ms621f 3.1V MS412F XH414H-IV02E
Text: Precautions for Your Safety SII Micro Parts Ltd. Lithium rechargeable batteries MS, HB, TS contain flammable organic solvents. For your safety, please follow the following prohibitions. WARNING! • Do not charge by high current or high voltage. Doing so may generate gas inside the battery, resulting
|
Original
|
|
PDF
|
NMO100
Abstract: NMO100S NMO200 NMO200S NMO500 NMO700 Resistors color coding
Text: Metal Oxide Film Resistors NMO Series FEATURES • NON-FLAMMABLE RESIN INSULATION • HIGH STABILITY AND RELIABILITY • LOW NOISE • LOW COST ALTERNATIVE TO CARBON COMPOSITION AND .WIREWOUND APPLICATIONS • NEW REDUCED SIZES • EIA COLOR CODING AND ALPHA-NUMERICAL CODING
|
Original
|
NMO100
NMO200m
NMO100
NMO100S
NMO200
NMO200S
NMO500
NMO700
Resistors color coding
|
PDF
|
EIA-172
Abstract: No abstract text available
Text: KOA SPEER ELECTRONICS, INC. SS-02 R5 AHA 3/07/05 Fixed Ceramic Composition Resistors Type PCF CERTIFIED CERTIFIED 1. Scope of Application This specification relates to non-flammable coated, insulated type, fixed ceramic resistors type PCF manufactured by KOA T&T Corporation.
|
Original
|
SS-02
EIA-172.
EIA-172
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Metal Oxide Film Resistors NMO Series FEATURES • NON-FLAMMABLE RESIN INSULATION • HIGH STABILITY AND RELIABILITY • LOW NOISE • LOW COST ALTERNATIVE TO CARBON COMPOSITION AND .WIREWOUND APPLICATIONS • NEW REDUCED SIZES • EIA COLOR CODING AND ALPHA-NUMERICAL CODING
|
Original
|
NMO100
|
PDF
|
japan 8709
Abstract: Logic PROBE diagram circuit oil pressure sensor generator TL 8709 LM1042 LM1042N automotive oil pressure electronic sensor fluid level circuit oil level circuit national "fluid level detector"
Text: LM1042 Fluid Level Detector General Description Features The LM1042 uses the thermal-resistive probe technique to measure the level of non-flammable fluids An output is provided proportional to fluid level and single shot or repeating measurements may be made All supervisory requirements
|
Original
|
LM1042
japan 8709
Logic PROBE diagram circuit
oil pressure sensor generator
TL 8709
LM1042N
automotive oil pressure electronic sensor
fluid level circuit
oil level circuit national
"fluid level detector"
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Metal Oxide Film Resistors NMO Series FEATURES • NON-FLAMMABLE RESIN INSULATION • HIGH STABILITY AND RELIABILITY • LOW NOISE • LOW COST ALTERNATIVE TO CARBON COMPOSITION AND .WIREWOUND APPLICATIONS • NEW REDUCED SIZES • EIA COLOR CODING AND ALPHA-NUMERICAL CODING
|
Original
|
NMO100
NMO200
NMO300
NMO500
|
PDF
|
ST 8709
Abstract: No abstract text available
Text: Semiconductor February 1995 LM1042 Fluid Level Detector General Description Features The LM1042 uses the thermal-resistive probe technique to measure the level of non-flammable fluids. An output is pro vided proportional to fluid level and single shot or repeating
|
OCR Scan
|
LM1042
ST 8709
|
PDF
|