Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    EW90 ANDREW WAVEGUIDE Search Results

    EW90 ANDREW WAVEGUIDE Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    APXV9R20B-C

    Abstract: Andrew dm65b-2x2 IEC-332-1 Andrew DB499-K-896-960 MHz ldf4-50a belden Kathrein Antennas SBNH-1D4545A lmr-400 uf APXV9
    Text: Where Technology Meets Innovation Wireless Products Mobile Switching Center Tower Distributed Antenna Systems DAS Mobile Backhaul Antennas and Accessories Coax Cables, Connectors and Support www.kgplogistics.com 800.755.1950 Helping you build the top of the tower from the ground up…


    Original
    PDF AD-107860-EN US07/3791 APXV9R20B-C Andrew dm65b-2x2 IEC-332-1 Andrew DB499-K-896-960 MHz ldf4-50a belden Kathrein Antennas SBNH-1D4545A lmr-400 uf APXV9

    190DET

    Abstract: EWP90S EWP90-107 F090PC0240CB andrew ew90 EWP90 andrew ewp90 190DEMT CPR-90G 190DE
    Text: Characteristics Type Numbers Super Premium Waveguide, Standard Jacket Premium Waveguide, Standard Jacket Standard Waveguide, Standard Jacket Premium Waveguide, Fire Retardant, Non-Halogenated Jacket Premium Waveguide Type CATVP EWP90S EWP90 EW90 35409-16*


    OCR Scan
    PDF ns/100 190DZ 5849A-15 1108A-1 1108A-2 1108A-3 190DET EWP90S EWP90-107 F090PC0240CB andrew ew90 EWP90 andrew ewp90 190DEMT CPR-90G 190DE

    WC166

    Abstract: p-5 RELAY WC281 WC109 EWP52 coaxial cable group chart microwave waveguide EW240 EW20 elliptical waveguide
    Text: Transmission Lines Widest Selection of microwave transmission lines in the industry. Andrew offers sizes and types that are optimized for nearly every application. HELIAX Coaxial Cables and Elliptical Waveguides have been, for many years, the standard transmission


    OCR Scan
    PDF sR137, WR112 WC281, WC166 WC166 p-5 RELAY WC281 WC109 EWP52 coaxial cable group chart microwave waveguide EW240 EW20 elliptical waveguide

    EW63 waveguide

    Abstract: EWP37 EWFTK-52 EWP63 ew52 waveguide elliptical EW77 P127A
    Text: Grounding Kits Easy Installation A well designed system uses grounding kits to provide a bond between the elliptical waveguide and the tower/earth ground system. One grounding kit is recom­ mended at tower top, tower bottom, at 200 ft 60 m intervals (where applicable), and at the entrance to the


    OCR Scan
    PDF EWP37, EWP43 EWP52, EWP63, EWP90, EW127A, P127A EW180, EW220, EWFTK-43 EW63 waveguide EWP37 EWFTK-52 EWP63 ew52 waveguide elliptical EW77

    EWP43

    Abstract: EWP63 EW17 EW132 EW34
    Text: M ic ro w a v e T ra n s m is s io n Lines H anger Spacing fo r h e l ia x Elliptical waveguide Recommended maximum hanger spacings are tabulated below for various wind speed and ice conditions. The recommendations are based on guidelines stated in EIA


    OCR Scan
    PDF RS-222 EWP34 EWP37 EWP43 EWP52 EWP63 EWP64 EWP77 EWP90 EWP127A EW17 EW132 EW34

    EWP34

    Abstract: EWP63 andrew ewp90 ew52 EWP43 EWP180
    Text: Hanger Spacing for HELIAX Elliptical Waveguide Recommended maximum hanger spacings are tabulated Installations in Typical Climates. Use the 125 mph 200 km/h , below for various wind speed and ice conditions. The 1/2" ice conditions, highlighted in red in the table.


    OCR Scan
    PDF RS-222 EIA-222 EWP34 EWP63 andrew ewp90 ew52 EWP43 EWP180

    reflectometer

    Abstract: WR112 PDR84 UBR84 waveguide R120 WR75 PDR26 37260 CBR120 CBR220 UBR220 PDR48 Waveguide EW63 waveguide
    Text: Hybrid T Reflectometer The Andrew hybrid T reflectometer is a unique and highly directive test component useful for measuring return loss or VSW R in waveguide systems. The reflectometer utilizes a precision hybrid T junction to separate the incident and reflected waves at the input of the system under test.


    OCR Scan
    PDF terminate137G CPR137G UG-344/U CPR112G CPR90G PDR22 PDR26 PDR32 reflectometer WR112 PDR84 UBR84 waveguide R120 WR75 37260 CBR120 CBR220 UBR220 PDR48 Waveguide EW63 waveguide

    EW34

    Abstract: EW180 EWP34
    Text: Grounding Kits A well designed system uses grounding kits to provide a bond between the elliptical waveguide and the tower/earth ground system. One grounding kit is recommended at tower top, tower bottom, at 200 ft 60 m intervals (where applicable), and at the entrance to the equipment shelter.


    OCR Scan
    PDF MIL-STD-188-124A. elim36 EWP17 EWP34 EWP37, EWP37S EWP43 EWP52, EWP52S EWP63, EW34 EW180

    reflectometer

    Abstract: CPR340G PDR26 CPR-430G CPR430G WR112 PDR84 UBR84 CPR-284G PDR32 UAR70 CBR220
    Text: M ic ro w a v e T ra n s m is s io n Lines Hybrid T Reflectometer The Andrew hybrid T reflectometer is a unique and high­ ly directive test component useful for measuring return loss or VSWR in waveguide systems. The reflectometer utilizes a precision hybrid T junction to separate the


    OCR Scan
    PDF wCPR137G CPR137G CPR112G CPR90G PDR22 PDR26 PDR32 PDR40 reflectometer CPR340G CPR-430G CPR430G WR112 PDR84 UBR84 CPR-284G UAR70 CBR220

    EWP90-105

    Abstract: No abstract text available
    Text: Ordering Information fo r HELIAX Elliptical Waveguide Assemblies Frequency' GHz Flange T y p e tt Waveguide Type Tunable C o nn ectort Pre-Tuned Fixed-Tuned Super Premium Waveguide Assemblies 10.7-11.7 EWP90S Flex-Twist 2 ft 0.6 m Pressure W indow VSWR 1.05 (32.3)*


    OCR Scan
    PDF EWP90S CPR90G PDR100 190DET 190DEMT F090PC0240CB F090MH0600HB EWP90-105

    EWP90-105

    Abstract: WGB4-90 190DEMT 190SE 55000A F090PC0240CA 223306-100 EWP90 EWP90-107 andrew ewp90
    Text: Ordering Information for Waveguide Assem blies Frequency* GHz Waveguide Type Connector* Tunable Fixed-Tuned Flange Typett Super Premium Waveguide Assemblies 10.7-11.7 EWP90S VSW R 1.05 32.3 * CPR90G PDR100 190DET 190DEMT 190SE 190SEM 55001-90 223306-100


    OCR Scan
    PDF CPR90G PDR100 190DET 190DEMT 190SE 190SEM F090PC0240CB F090MH0600HB EWP90-105 WGB4-90 55000A F090PC0240CA 223306-100 EWP90 EWP90-107 andrew ewp90

    EWP77

    Abstract: EW77 ew52 stainless steel bolt and galvanized andrew ew90
    Text: Elliptical W aveguide Hangers A , B W a ve g u id e H a n g e r K it of 10 stainless steel hangers. Mount with 3/8" hardware or adapters. R ec om m en d ed M a xim u m F o r W avegu ide W ave gu ide Photo Type Nu m be rs H a n g e r Kit R e f. ft m 3 17 6 6 A -9


    OCR Scan
    PDF Hanger/45° EWP77 EW77 ew52 stainless steel bolt and galvanized andrew ew90

    EWP90S

    Abstract: No abstract text available
    Text: M icrow ave Tran sm issio n Lines 42396A Series Gripping Tabs Prevent waveguide slippage without the need for a hoisting grip. Pre-Assem bled and C aptivated Hardw are Eliminates the need for field assembly. Springlike Flexibility Makes it easy to form the hanger around the waveguide


    OCR Scan
    PDF 2396A EWP17 EWP34 EWP37, EWP37S EWP43 EWP52, EWP52S EWP90S

    EW90 andrew waveguide

    Abstract: ew52 EW52 waveguide EW132 waveguide elliptical EWFTK-52 EW63 waveguide EWFTK-63
    Text: Grounding Kits / Flaring Tools Kits Include Standard Grounding Kits for Ellip tical W aveguide. Series 204989 and 241088 kits include a solid copper strap riveted to the grounding wire, a coil tool for proper tightening, tower attachment hardware, and a two-part


    OCR Scan
    PDF EWP37, EWP37S EWP52, EWP63, EWP64 EWP77 EWP90, EW127A, P127A EW132, EW90 andrew waveguide ew52 EW52 waveguide EW132 waveguide elliptical EWFTK-52 EW63 waveguide EWFTK-63

    Untitled

    Abstract: No abstract text available
    Text: W aveguide fo r 10.5 - 10.7 GHZ & 1 0 .7 - 1 1 .7 GHz Bands Refer to pages 10 and 11 for Antenna information Characteristics Type N u m b e rs S uper Prem ium W aveguide, Standard Jacket Prem ium W aveguide. Standard Jacket Standard W aveguide, S tandard Jacket


    OCR Scan
    PDF ns/100 190DZ 5849A 08A-1 1108A

    CPR-90G

    Abstract: EW90 andrew waveguide
    Text: Elliptical W aveguide Types EWP90S, EWP90 and EW90 Characteristics T yp e N u m be rs Super Premium Waveguide, Standard Jacket Premium Waveguide, Standard Jacket Standard Waveguide, Standard Jacket Premium Waveguide, Fire Retardant, Non-Halogenated Jacket


    OCR Scan
    PDF EWP90S, EWP90 ns/100 CPR-90G EW90 andrew waveguide

    WR75 waveguide switch

    Abstract: UHX-34 SD-002A andrew pressurization monitor type 40004 heliax MTH-050 MT050 mr05 WC281 GLW1700
    Text: Dehydrator Selection Considerations • Total System Volume • System Pressure Rating • Availability of Maintenance • Availability o f Electric Power Total System Volume. System volume is determined by totaling the volume of each air dielectric transmission line


    OCR Scan
    PDF 2813A WR75 waveguide switch UHX-34 SD-002A andrew pressurization monitor type 40004 heliax MTH-050 MT050 mr05 WC281 GLW1700