Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    ETS150T Search Results

    ETS150T Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    DIN 2248

    Abstract: No abstract text available
    Text: HELIAX Connector P R O D U C T S P E C I F I C A T I O N T1PDF-ABPM 7-16 Din Female Panel Mount Connector for ETS1-50T and FSJ1-50 CHARACTERISTICS Electrical Recommended maximum operating frequency, GHz 7.50 Peak power, max, kW 6.40 Average power, max, kW @ 900 MHz


    Original
    PDF ETS1-50T FSJ1-50 DIN 2248

    HJ7RN-50A

    Abstract: LDF5RN-50A HJ5RN-50 Andrew fsj4rn-50b UL-910 FSJ175 HJ5RP-50 fsj1 ldf4.5-50 EFX2RN-50
    Text: Ü-aaJLtal Calilas Coaxial Cable Selection Guide KIELIAT H ELIA X Coaxial Cable Selection Guide - 50 -ohm , Foam Dielectric Superflexible, F S J Series Extraflexible, Foam Dielectric, EFX Series VXL Series Nominal Size 1/4" 3/8" 1/2" 3/8" 7/8" Catalog Pages


    OCR Scan
    PDF UL1581, UL1666 FSJ1P-50A-C* FSJ2P-50-C* FSJ4P-50B-( HJ7RN-50A LDF5RN-50A HJ5RN-50 Andrew fsj4rn-50b UL-910 FSJ175 HJ5RP-50 fsj1 ldf4.5-50 EFX2RN-50

    Andrew Rxl5-1RNT

    Abstract: Andrew RADIAx Andrew Rxl4 RXL5 - 1RNT RXL4 - 1RNT RXL4 RXL4-2RNT Andrew RXL2-2RNT RXL6 LDF4RN-50A
    Text: HELIAX Coaxial Cables Fire Retardant Cables and Waveguides Fire R etardance Requirem ents Cable and waveguide installed inside a building usually must meet fire retardance requirements. In the United States, the National Electrical Code NEC ’ sets the standard for coaxial cable used within buildings and


    OCR Scan
    PDF

    Andrew FSJ4-50B

    Abstract: ETS2-50T delay line ldf ft-450 RG214/RG142 velocity factor Andrew 7/LDF1-50 HELIAX
    Text: Phase Measured Cable Assem blies Phase Stabilized Cable HELIAX phase measured cable assemblies are excellent fo r applications where signals arrive in phase such as phased array radar, or fo r delay lines cut to precision electrical length. Both phase matched and delay lines are


    OCR Scan
    PDF

    UL-910

    Abstract: No abstract text available
    Text: Attenuation and Average Power Ratings Frequency MHz ETS1-50T Cable Ordering Information High Power, Plenum Cables 1/4" Fire Retardant Jacket CATVP, UL910 1/4" Unjacketed, Fire Retardant (CATVP, UL910) ETS1-50T ETS1-50 Jum per Cable A sse m blies - See page 584


    OCR Scan
    PDF dB/100 ETS1-50T1 04679A-17 UL-910

    ldf4 cable

    Abstract: HJ5-50 ETS1-50 ETS2-50T RG214/FSJ1-50A Andrew 7/LDF1-50 HELIAX
    Text: Phase Measured Cable Assemblies HELI AX phase measured cable assemblies are excellent for applications where signals arrive in phase such as phased array radar, or for delay lines cut to precision electrical length. Both phase matched and delay lines are available with precision or standard length tolerances and


    OCR Scan
    PDF ETS2-50T HJ4-50 HJ5-50 ldf4 cable HJ5-50 ETS1-50 RG214/FSJ1-50A Andrew 7/LDF1-50 HELIAX

    VP2A-130

    Abstract: pl1537 3AX6 2261A EBLOK-00005 VHP2-220A 143DET RxL4-1rn FPA5250D24-N VHP2-180B
    Text: N u m erical Index Type Number Page 100845-11 .211 10


    OCR Scan
    PDF XH-1-711 XH-4A-101. XH-4A-102. XH-4A-11 XH-4A-701 -4A-702. VP2A-130 pl1537 3AX6 2261A EBLOK-00005 VHP2-220A 143DET RxL4-1rn FPA5250D24-N VHP2-180B

    c41swb

    Abstract: C41ASW-RA
    Text: ETS1-50T Cable Ordering Information D escription Attenuation and Average Power Ratings Type No. Frequency MHz High Power, Plenum Cables 1/4" Fire Retardant Jacket CATVP, UL910 1/4" Unjacketed, Fire Retardant (CATVP, UL910) ETS1-50T ETS1-50 Jumper Cable Assemblies


    OCR Scan
    PDF ETS1-50T UL910) ETS1-50T ETS1-50 dB/100 dB/100m CT-K350 VCT8-10 VCT8-50 c41swb C41ASW-RA

    RXL7 connector

    Abstract: RXL4 - 1RNT RXL6 Andrew Rxl6 CONNECTOR RxL4-1rn RXL4-2RNT LDF5RN-50A VXL5RN-50 Andrew RADIAX RXL-4 EFX2RN-50
    Text: Fire Retardant Cables and Waveguides Fire Retardance Requirements Cable and waveguide installed inside a building usually must meet fire retardance requirements. In the United States, the National Electrical Code NEC 1 sets the stan­ dard for coaxial cable used within buildings and normally


    OCR Scan
    PDF