    10106133-2000002LF Amphenol Communications Solutions PwrBlade+® , Power Connectors, 2HP PF, Right Angle, Header. Visit Amphenol Communications Solutions
    10106133-2000004LF Amphenol Communications Solutions PwrBlade+® , Power Connectors, 2HP PF, Right Angle, Header. Visit Amphenol Communications Solutions
    10106133-2000401LF Amphenol Communications Solutions PwrBlade+® , Power Connectors, 2HDP, Right Angle, Header. Visit Amphenol Communications Solutions
    10106133-2000005LF Amphenol Communications Solutions PwrBlade+® , Power Connectors, 2HDP PF, Right Angle, Header. Visit Amphenol Communications Solutions
    10106133-2000A02LF Amphenol Communications Solutions PwrBlade+® Connector, Power Connectors, 2HP PF, Right Angle, Header. Visit Amphenol Communications Solutions

    EN 133200 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    133016F

    Abstract: No abstract text available
    Text: Amphenol Serie ECTA 133 Connecteurs testés et certifiés selons EN 61984 per VDE N. 6908 Steckerbaureihe geprüft und zertifiziert nach DIN EN 61984 unter VDE Reg.Nr. 6908 Connectors tested and certified according to EN 61984 per VDE registration number 6908


    Original
    PDF D-66740 133016F

    7610

    Abstract: EN 133200
    Text: AC feedthrough filters • • • • EN 133200 approval 10 to 300A current ratings 5kV pulse test capability Class Y2 capacitors • • • • nach EN 133200 geprüft Nennströme von 10 bis 300A für 5kV-Pulsprüfungen geeignet Kondensator der Klasse Y2


    Original
    PDF 7612-100/M867 7612-10/M3 7612-16/M4 7612-32/M4 7612-63/M6 7612-63/M6A 7612-63/M6B 7612-100/M8 7612-100/M8A 7612-100/M8B 7610 EN 133200

    capacitor 104 m30

    Abstract: No abstract text available
    Text: AC feedthrough filters • • • • EN 133200 approval 10 to 250A current ratings 5kV pulse test capability Class Y2 capacitors • • • • nach EN 133200 geprüft Nennströme von 10 bis 250A für 5kV-Pulsprüfungen geeignet Kondensator der Klasse Y2


    Original
    PDF 7612-100/M8 feedth10/M3 7612-16/M4 7612-32/M4 7612-63/M6 7612-63/M6A 7612-63/M6B 7612-100/M8A 7612-100/M8B capacitor 104 m30

    EN 133200

    Abstract: No abstract text available
    Text: DC feedthrough filters • • • • EN 133200 approval 10 to 200A current ratings 2.5kV pulse test capability Class Y4 capacitors • • • • nach EN 133200 geprüft Nennströme von 10 bis 200A für 2,5kV-Pulsprüfungen geeignet Kondensator der Klasse Y4


    Original
    PDF 7661-32/M4 feedthro-100/M8 7660-200/M10 7661-10/M3 7661-16/M4 7661-63/M6 7661-100/M8 7661-200/M10 7661-200/M10A EN 133200

    7660

    Abstract: EN 133200 7660 datasheet 201010K 766010 766063
    Text: DC feedthrough filters • • • • EN 133200 approval 10 to 200A current ratings 2.5kV pulse test capability Class Y4 capacitors • • • • nach EN 133200 geprüft Nennströme von 10 bis 200A für 2,5kV-Pulsprüfungen geeignet Kondensator der Klasse Y4


    Original
    PDF 7661-3260-32/M4 7660-63/M6 7660-100/M8 7660-200/M10 7661-10/M3 7661-16/M4 7661-32/M4 7661-63/M6 7661-100/M8 7661-200/M10 7660 EN 133200 7660 datasheet 201010K 766010 766063

    EN 133200

    Abstract: No abstract text available
    Text: AC feedthrough filters • • • • EN 133200 approval 10 to 250A current ratings 5kV pulse test capability Class Y2 capacitors • • • • Nach EN 133200 geprüft Nennströme von 10 bis 250A Für 5kV-Pulsprüfungen geeignet Kondensator der Klasse Y2


    Original
    PDF 7612-100/M8 7611-10/M3 7611-16/M4 7611-32/M4 7611-63/M6 7611-250/M12 7612-10/M3 7612-16/M4 7612-32/M4 7612-63/M6 EN 133200

    Untitled

    Abstract: No abstract text available
    Text: DC feedthrough filters • • • • EN 133200 approval 10 to 200A current ratings 2.5kV pulse test capability Class Y4 capacitors • • • • Nach EN 133200 geprüft Nennströme von 10 bis 200A Für 2,5kV-Pulsprüfungen geeignet Kondensator der Klasse Y4


    Original
    PDF 7661-32/M4 7660-10/M3 7660-32/M4 7660-63/M6 7660-100/M8 7660-200/M10 7661-10/M3 7661-16/M4 7661-63/M6

    EN 133200 fmw2

    Abstract: fmw2-41 znrvaristor znr-varistor fmw241 FMW2413I
    Text: EMC Interference Suppression Filters for 1-phase systems FMW2-41 Series, all-purpose filters to Protection Class I, conform to EN 133200, UL 1283 and IEC 950 Nominal current: Nominal voltage max. : Attenuation: Leakage current: Test voltage: Climatic category:


    Original
    PDF FMW2-41 MIL-HB-217 FMW2-41-1/I FMW2-41-3/I FMW2-41-6/I FMW2-41-10/I EN 133200 fmw2 znrvaristor znr-varistor fmw241 FMW2413I

    timonta fmad

    Abstract: timonta timonta fmbc 0932-2510 EN 133200 FMAD-0937-8010 m-927 circuit diagram of stepper FMAD-0953-6410 FMAD-0934-3610 FMAD-0931-0810
    Text: High Current Line Filters for 3-phase + neutral systems FMAD Series, all-purpose filters to Protection Class I, conform to EN 133200, UL 1283 and IEC 60950 Nominal current: Rated voltage UR Umax. : Attenuation: Leakage current: Test voltages: Climatic category:


    Original
    PDF 25kVDC, MIL-HB-217 timonta fmad timonta timonta fmbc 0932-2510 EN 133200 FMAD-0937-8010 m-927 circuit diagram of stepper FMAD-0953-6410 FMAD-0934-3610 FMAD-0931-0810

    EN 133200

    Abstract: FMW4-95-6 IT mains FMW4
    Text: EMC-RFI Suppression Filters for 3-phase + neutral systems FMW4-65 Series, all-purpose filters to Protection Class I, for standard requirements, conform to EN 133200, UL 1283 and IEC 60950 Nominal current: Rated voltage UR Umax. : Attenuation: Leakage current:


    Original
    PDF FMW4-65 MIL-HB-217 100-a EN 133200 FMW4-95-6 IT mains FMW4

    3 phase EMI filter

    Abstract: No abstract text available
    Text: Seite 1 HLD 110-500/55 Radio interference suppression filter Errors and omissions excepted. Please note that product illustrations do not resemple all product variants. Three-phase For increased requirements Radio interference suppr. filter to DIN EN 133200, UL 1283


    Original
    PDF

    timonta

    Abstract: FMAD-0924-0610 FMAD-0931-0810 FMAD-0931-1610 FMAD-0932-2510 FMAD-0934-3610 FMAD-0934-5010 FMAD-0937-8010 FMAD-0953-6410 timonta FMAD-0932-2510
    Text: High Current Line Filters for 3-phase + neutral systems FMAD Series, all-purpose filters to Protection Class I, conform to EN 133200, UL 1283 and IEC 950 Nominal current: Nominal voltage max. : Attenuation: Leakage current: Test voltage: Climatic category:


    Original
    PDF MIL-HB-217 timonta FMAD-0924-0610 FMAD-0931-0810 FMAD-0931-1610 FMAD-0932-2510 FMAD-0934-3610 FMAD-0934-5010 FMAD-0937-8010 FMAD-0953-6410 timonta FMAD-0932-2510

    3 phase EMI filter

    Abstract: EN 133200
    Text: Seite 1 HLD 110-500/8 Radio interference suppression filter Errors and omissions excepted. Please note that product illustrations do not resemple all product variants. Three-phase For increased requirements Radio interference suppr. filter to DIN EN 133200, UL 1283


    Original
    PDF

    l 5010 mh

    Abstract: fuse 5x20 506 k
    Text: EMC-RFI Suppression Filters 1-phase systems FKHD/FKID Series, combi-filters to Protection Class I, conform to EN 133200, UL 1283 and IEC 950 Nominal current: Nominal voltage max. : Attenuation: Leakage current: Test voltage: Climatic category: 50% saturation typ.:


    Original
    PDF MIL-HB-217 FKXD2-50-x-/I-A FKHD2-50-1/I FKHD2-50-2/I FKHD2-50-4/I FKHD2-50-6/I FKHD2-50-10/I l 5010 mh fuse 5x20 506 k

    timonta fmac 0932-2510

    Abstract: timonta 240 110 voltage converter timonta 35 EN 138100 FMAC-0955-H210
    Text: High Current Line Filters for 3-phase systems FMAC Series, all-purpose filters to Protection Class I, conform to EN 133200, UL 1283 and IEC 950 Nominal current: Nominal voltage max. : Attenuation: Leakage current: Test voltage: Climatic category: 50% saturation typ.:


    Original
    PDF MIL-HB-217 timonta fmac 0932-2510 timonta 240 110 voltage converter timonta 35 EN 138100 FMAC-0955-H210

    EN 133200

    Abstract: No abstract text available
    Text: Seite 1 HLD 110-500/30 Radio interference suppression filter Errors and omissions excepted. Please note that product illustrations do not resemple all product variants. Three-phase For increased requirements Radio interference suppr. filter to DIN EN 133200, UL 1283


    Original
    PDF

    FPP2

    Abstract: FPF2-48-1 fpp2-45 FPF2 FPP2-45-4 FPP2-45-1 FPP2-45-6 EN 133200 A 4510 D 271p
    Text: EMC-Power Line Filters FP Series, industrial-mains-filters to Protection Class I, in plastic case, conform to EN 133200, UL 1283 and IEC 950 Nominal current: Nominal voltage max. : Attenuation: Leakage current: Test voltage: (1) Climatic category: 50% saturation typ.:


    Original
    PDF MIL-HB-217 27-1P FPP2 FPF2-48-1 fpp2-45 FPF2 FPP2-45-4 FPP2-45-1 FPP2-45-6 EN 133200 A 4510 D 271p

    Timonta

    Abstract: FMAB-0924-2010 FMAB-0924-1210 EN 133200 FMAB-0924-3010
    Text: High Current Line Filters for 1-phase systems FMAB Series, all-purpose filters to Protection Class I, conform to EN 133200, UL 1283 and IEC 950 Nominal current: Nominal voltage max. : Attenuation: Leakage current: Test voltage: Climatic category: 50% saturation typ.:


    Original
    PDF MIL-HB-217 FMAB-0924-1210 FMAB-0924-2010 50/60Hz FMAB-0924-3010 100-a Timonta FMAB-0924-2010 FMAB-0924-1210 EN 133200 FMAB-0924-3010

    iec 38

    Abstract: No abstract text available
    Text: Seite 1 HLD 110-500/42 Radio interference suppression filter Errors and omissions excepted. Please note that product illustrations do not resemple all product variants. Three-phase For increased requirements Radio interference suppr. filter to DIN EN 133200, UL 1283


    Original
    PDF

    110500

    Abstract: 133200
    Text: Seite 1 HLD 110-500/16 Radio interference suppression filter Errors and omissions excepted. Please note that product illustrations do not resemple all product variants. Three-phase For increased requirements Radio interference suppr. filter to DIN EN 133200, UL 1283


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: EMC-Power Line Filters for 1-Phase Systems FSW2 Series, 2-stage all-purpose filters to Protection Class I, with high asymmetrical insertion loss, conform to EN 133200, UL 1283 and IEC 60950 Nominal current: Rated voltage UR Umax : Attenuation: Leakage current:


    Original
    PDF MIL-HB-217 100-a

    EN 133200

    Abstract: No abstract text available
    Text: EMC-Power Line Filters for 1-Phase Systems FMAB Series, all-purpose filters to Protection Class I, conform to EN 133200, UL 1283 and IEC 60950 Nominal current: Rated voltage UR Umax : Attenuation: Leakage current: Test voltages: Climatic category: 50% saturation typ.:


    Original
    PDF MIL-HB-217 100-a EN 133200

    EN 133200

    Abstract: emcp
    Text: EMC-Power Line Filters for 1-Phase Systems FMLB Series, all-purpose filters to Protection Class I, conform to EN 133200, UL 1283 and IEC 60950 Nominal current: Rated voltage UR Umax : Attenuation: Leakage current: Test voltages: Climatic category: 50% saturation typ.:


    Original
    PDF MIL-HB-217 100-a EN 133200 emcp

    EN 133200

    Abstract: No abstract text available
    Text: EMC-Power Line Filters for 1-Phase Systems FSS2 Series, 2-stage all-purpose filters to Protection Class I, with high symmetrical insertion loss, conform to EN 133200, UL 1283 and IEC 60950 Nominal current: Rated voltage UR Umax : Attenuation: Leakage current:


    Original
    PDF MIL-HB-217 100-a EN 133200