glucose
Abstract: No abstract text available
Text: Handheld Electrochemical Blood Glucose Meter Table of Contents DATA INTERFACE, IrDA. 3 DATA INTERFACE, USB. 4
|
Original
|
Si3812DV
125mOhms
CRCW0402
1000h
CRCW0603
glucose
|
PDF
|
Untitled
Abstract: No abstract text available
Text: sales@ioxus.com Electrochemical Double Layer Capacitor SERIES: PRISMATIC ULTRACAPACITOR FEATURES Made in the USA High energy density High power density Low internal resistance ESR 10 year life High cycle life (+500K cycles) RoHS compliant APPLICATIONS Back-up power
|
Original
|
RSC2R7108SP
|
PDF
|
ARALDITE 2023
Abstract: butyrolactone corrosion inhibitor araldite Z. Dou, R. Xu, A. Berduque, CARTS Europe 2008 Berduque bhc capacitor WEY450-1 ammonium phosphoric acid
Text: Electrochemical Studies for Aluminium Electrolytic Capacitor Applications: Corrosion Analysis of Aluminium in Ethylene Glycol-Based Electrolytes Alfonso Berduque, Zongli Dou, Rong Xu Electrolytic Innovation Centre BHC Components Ltd KEMET 20 Cumberland Drive, Granby Industrial Estate
|
Original
|
di2004.
org/CARTSEurope/2009/virtual/index
ARALDITE 2023
butyrolactone
corrosion inhibitor
araldite
Z. Dou, R. Xu, A. Berduque, CARTS Europe 2008
Berduque
bhc capacitor
WEY450-1
ammonium
phosphoric acid
|
PDF
|
Untitled
Abstract: No abstract text available
Text: TSU101 Nanopower, rail-to-rail input and output, 5 V CMOS operational amplifier Datasheet - production data Applications • Ultra long life battery-powered applications • Power metering • UV and photo sensors • Electrochemical and Gas sensors SC70-5
|
Original
|
TSU101
SC70-5
OT23-5
TSU101
DocID024317
|
PDF
|
marking code avx label
Abstract: BZ015A503ZAB35 thin supercapacitor 4.2V
Text: BestCap Ultra-low ESR High Power Pulse Supercapacitors GENERAL DESCRIPTION The BestCap™ series of electrochemical supercapacitors offer excellent high power pulse characteristics based upon the combination of very high capacitance and ultra low ESR in the milliOhm region.
|
Original
|
560mF
marking code avx label
BZ015A503ZAB35
thin supercapacitor 4.2V
|
PDF
|
biosensor
Abstract: No abstract text available
Text: DATA SHEET D LND-BA1K ADDRESSABLE BIOSENSOR ARRAYS GENERAL DESCRIPTION FEATURES The custom oligonucleotide microarray is synthesized using a semiconductor-based electrochemical-synthesis process. Each oligonucleotide probe is synthesized via a platinum electrode that is independently controlled
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: 19-4252; Rev 1; 10/08 12-/16-Bit DASs with ADC, DACs, DPIOs, APIOs, Reference, Voltage Monitors, and Temp Sensor Applications Battery-Powered and Portable Devices Electrochemical and Optical Sensors Medical Instruments Industrial Control Data Acquisition Systems
|
Original
|
12-/16-Bit
12-Bit
312ksps,
1000sps,
16-Word
20-Bit
16-Input
52-/16-Bit
|
PDF
|
MAX1330
Abstract: APIO tDA 2053
Text: 19-4252; Rev 0; 8/08 12-/16-Bit DASs with ADC, DACs, DPIOs, APIOs, Reference, Voltage Monitors, and Temp Sensor Applications Battery-Powered and Portable Devices Electrochemical and Optical Sensors Medical Instruments Industrial Control Data Acquisition Systems
|
Original
|
12-/16-Bit
MAX1329/MAX1330
312ksps.
MAX1329/MAX1330
T4066-5
MAX1330
APIO
tDA 2053
|
PDF
|
potentiostat
Abstract: max13301 8474D dpio2 SPDT2 maxim adc 16 bit power suply tl 494 tDA 2045 TDA 6200 circuit board VM1 2505
Text: 19-4252; Rev 1; 10/08 12-/16-Bit DASs with ADC, DACs, DPIOs, APIOs, Reference, Voltage Monitors, and Temp Sensor Applications Battery-Powered and Portable Devices Electrochemical and Optical Sensors Medical Instruments Industrial Control Data Acquisition Systems
|
Original
|
12-/16-Bit
12-Bit
312ksps,
1000sps,
16-Word
20-Bit
16-Input
Ref12-/16-Bit
potentiostat
max13301
8474D
dpio2
SPDT2
maxim adc 16 bit
power suply tl 494
tDA 2045
TDA 6200 circuit board
VM1 2505
|
PDF
|
Untitled
Abstract: No abstract text available
Text: sales@ioxus.com Electrochemical Double Layer Capacitor SERIES: PRISMATIC ULTRACAPACITOR FEATURES Made in the USA High energy density High power density Low internal resistance ESR 10 year life High cycle life (+500K cycles) RoHS compliant APPLICATIONS Utility energy storage
|
Original
|
RSC2R7208SP
|
PDF
|
Untitled
Abstract: No abstract text available
Text: sales@ioxus.com Electrochemical Double Layer Capacitor SERIES: PRISMATIC ULTRACAPACITOR FEATURES Made in the USA High energy density High power density Low internal resistance ESR 10 year life High cycle life (+500K cycles) RoHS compliant APPLICATIONS Utility energy storage
|
Original
|
RSC2R7308SP
|
PDF
|
potentiostat
Abstract: Carbon Monoxide SENSOR CIRCUIT DIAGRAM L9100 simple blood glucose meter circuit diagram L91000 op amp in potentiostat gas Smart meter chemical sensor circuit diagram of blood glucose meter LMP9100
Text: LMP91000 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications General Description Features The LMP91000 is a programmable Analog Front End AFE for use in micro-power electrochemical sensing applications. It provides a complete signal path solution between a sensor
|
Original
|
LMP91000
LMP91000
potentiostat
Carbon Monoxide SENSOR CIRCUIT DIAGRAM
L9100
simple blood glucose meter circuit diagram
L91000
op amp in potentiostat
gas Smart meter
chemical sensor
circuit diagram of blood glucose meter
LMP9100
|
PDF
|
op amp in potentiostat
Abstract: gas module sensor based blood glucose sensor block diagram L91000 Model 275K simple blood glucose meter circuit diagram circuit diagram of blood glucose meter
Text: LMP91000 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications General Description Features The LMP91000 is a programmable Analog Front End AFE for use in micro-power electrochemical sensing applications. It provides a complete signal path solution between a sensor
|
Original
|
LMP91000
op amp in potentiostat
gas module sensor
based blood glucose sensor block diagram
L91000
Model 275K
simple blood glucose meter circuit diagram
circuit diagram of blood glucose meter
|
PDF
|
Carbon Monoxide SENSOR CIRCUIT DIAGRAM
Abstract: circuit diagram of blood glucose meter potentiostat l9100 Amperometric medical sensor LMP9100 L91000 op amp in potentiostat carbon monoxide sensor electrochemical oxygen gas sensor
Text: LMP91000 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications General Description Features The LMP91000 is a programmable Analog Front End AFE for use in micro-power electrochemical sensing applications. It provides a complete signal path solution between a sensor
|
Original
|
LMP91000
LMP91000
Carbon Monoxide SENSOR CIRCUIT DIAGRAM
circuit diagram of blood glucose meter
potentiostat
l9100
Amperometric medical sensor
LMP9100
L91000
op amp in potentiostat
carbon monoxide sensor electrochemical
oxygen gas sensor
|
PDF
|
|
RSC2R7357
Abstract: ultracapacitor
Text: Electrochemical Double Layer Capacitor sales@ioxus.com SERIES: SNAP-IN ULTRACAPACITOR FEATURES Made in the USA High energy density High power density Low internal resistance ESR 10 year life High cycle life (+500K cycles) RoHS compliant APPLICATIONS Back-Up Power
|
Original
|
RSC2R7357SR
RSC2R7357
ultracapacitor
|
PDF
|
Untitled
Abstract: No abstract text available
Text: UC10.241, UC10.242 24V, 15A, CAPACITOR-BASED BUFFER MODULES UC-Series CAPACITOR-BASED BUFFER MODULES ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ ̇ Built-in Capacitors as Energy Source EDLC Electrochemical Double Layer Capacitors Wide Temperature Range from -40°C to +60°C
|
Original
|
DS-UC10
241-EN
|
PDF
|
Untitled
Abstract: No abstract text available
Text: sales@ioxus.com Electrochemical Double Layer Capacitor SERIES: SNAP-IN ULTRACAPACITOR FEATURES Made in the USA High energy density High power density Low internal resistance ESR 10 year life High cycle life (+500K cycles) RoHS compliant APPLICATIONS Back-Up Power
|
Original
|
RSC2R7357ST
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Electrochemical Double Layer Capacitor info@ioxus.com SERIES: SCREW TERMINAL EDLC FEATURES Made in the USA High energy density High power density Low internal resistance ESR 10 year life High cycle life (+500K cycles) RoHS compliant APPLICATIONS Back-Up Power
|
Original
|
RSC2R7407LR
|
PDF
|
0829A
Abstract: No abstract text available
Text: Philips Components Product specification A.C. Motor Start Capacitor Series 3500 A.C. Motor Start Capacitor D escription Features Philips Components Series 3500 A.C. motor-start capac itor is an electrochemical device consisting of compactly wound aluminum foils separated by layers of paper, which
|
OCR Scan
|
|
PDF
|
potentiostat* glucose 2 electrodes 3
Abstract: Carbon Monoxide SENSOR CIRCUIT DIAGRAM op amp in potentiostat based blood glucose sensor block diagram carbon monoxide sensor Model 275K equivalent
Text: LMP91000 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications General Description Features The LMP91000 is a programmable Analog Front End AFE for use in micro-power electrochemical sensing applications. It provides a complete signal path solution between a sensor
|
Original
|
LMP91000
potentiostat* glucose 2 electrodes 3
Carbon Monoxide SENSOR CIRCUIT DIAGRAM
op amp in potentiostat
based blood glucose sensor block diagram
carbon monoxide sensor
Model 275K equivalent
|
PDF
|
3534b
Abstract: 189-227 mfd EIA-463 3535B 161-193 mfd 3534B4 3535B1a0064a125 Motor Start Capacitor, 72-88 MFD 3534B5A0540A110 start capacitor 3534
Text: BCcomponents, Inc. SERIES 3500 DESCRIPTION BCcomponents Series 3500 AC motor start Capacitor is an electrochemical device consisting of compactly wound aluminum foil separated by layers of paper impregnated with a conducting electrolyte. Etching of the foil prior to formation and winding increases
|
Original
|
3534B7A0088A330
3534B8A0108A330
3534B8A0124A330
3534B8A0145A330
3534b
189-227 mfd
EIA-463
3535B
161-193 mfd
3534B4
3535B1a0064a125
Motor Start Capacitor, 72-88 MFD
3534B5A0540A110
start capacitor 3534
|
PDF
|
LT3973-3.3
Abstract: 0829A LT3971-3.3
Text: SERIES 3 5 0 0 i i DESCRIPTION FEATURES Philips Components Series 3500 A.C. motor-start capacitor is an electrochemical device consisting of compactly wound aluminum foil separated by layers of paper, which are impregnated with a conducting electrolyte. Etching of the foil prior to
|
OCR Scan
|
|
PDF
|
dielectric constant of tantalum capacitor
Abstract: manganese oxide cathode for tantalum capacity "Reliability failure rate of solid tantalum electrolytic capacitors is"
Text: Technical Note Tantalum Chip Capacitors Structure of a tantalum chip capacitor To manufacture a tantalum chip capacitor, metallic tantalum Ta powder is pressed and formed with a tantalum lead wire, and then sintered in a vacuum; by the electrochemical anodic oxidation, tantalum oxide film
|
Original
|
2005/2006E
dielectric constant of tantalum capacitor
manganese oxide cathode for tantalum capacity
"Reliability failure rate of solid tantalum electrolytic capacitors is"
|
PDF
|
Carbon Monoxide SENSOR CIRCUIT DIAGRAM
Abstract: op amp in potentiostat Amperometric medical sensor circuit diagram of blood glucose meter based on 8 potentiostat potentiostat* glucose 2 electrodes 3 circuit diagram of blood glucose meter carbon monoxide sensor circuit diagram glucose meter 106 35K 011
Text: LMP91002 Sensor AFE System: Configurable AFE Potentiostat for Low-Power Chemical Sensing Applications General Description Features The LMP91002 is a programmable Analog Front End AFE for use in micro-power electrochemical sensing applications. It provides a complete signal path solution between a not biased gas sensor and a microcontroller generating an output
|
Original
|
LMP91002
Carbon Monoxide SENSOR CIRCUIT DIAGRAM
op amp in potentiostat
Amperometric medical sensor
circuit diagram of blood glucose meter based on 8
potentiostat
potentiostat* glucose 2 electrodes 3
circuit diagram of blood glucose meter
carbon monoxide sensor
circuit diagram glucose meter
106 35K 011
|
PDF
|