Untitled
Abstract: No abstract text available
Text: Current Probes Accurately Measure AC, DC and Impulse Currents Measure Currents in a Wide Range of Applications Measuring AC and DC Currents LeCroy current probes do not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current
|
Original
|
PDF
|
CP031
CP030
AP015
CP150
CP500
1-800-5-LeCroy
|
Untitled
Abstract: No abstract text available
Text: ACM3P Series www.murata-ps.com s Three-Phase AC Ammeters Actual size C US E156931 FEATURES PRODUCT OVERVIEW Measure and display the true-rms current of 3-phase power systems Universal 85-264Vac 47-63Hz operating supply range Three built-in current transformers measure up to
|
Original
|
PDF
|
E156931
85-264Vac
47-63Hz)
120Vac
|
71M6513
Abstract: 581 EL BAV99DW 3 phase energy meter
Text: 71M6513 3-Phase Energy Meter IC A Maxim Integrated Products Brand APPLICATION NOTE AN_6513_021 AUGUST 2005 71M6513 Neutral Current Measurement The ability to measure Neutral Currents is a key feature to enable the user to enhance tamper detection techniques. The current demo board firmware has the capability to measure Neutral Currents using the
|
Original
|
PDF
|
71M6513
71M6513
581 EL
BAV99DW
3 phase energy meter
|
5300-0005
Abstract: current transformers 5304 transformer
Text: Current Sensors/Transformers API Technologies offers a wide range of current sensors that measure electrical current AC&DC and can transform current from high to low measurable values. API series 5300 current sensors are available with current ranges from
|
Original
|
PDF
|
53FT01
53FT02
5300-0005
current transformers
5304 transformer
|
AC ammeter and ct diagram
Abstract: AC ammeter diagram DMS-20RM analog AC Ammeter ammeter ac analog AC ammeter diagram measure current toroid
Text: ACA5-20RM Series www.murata-ps.com True-rms-AC Ammeters with 5A CT Inputs FEATURES • Scales and displays the true-rms output of 5A current transformers ■ Accurately measure complex ac current waveforms ■ Perfect for measuring current in IT applications
|
Original
|
PDF
|
ACA5-20RM
85-140Vac
170-264Vac
50/60Hz)
AC ammeter and ct diagram
AC ammeter diagram
DMS-20RM
analog AC Ammeter
ammeter ac
analog AC ammeter diagram
measure current toroid
|
DIGITAL ammeter block diagram
Abstract: AC ammeter diagram AC ammeter and ct diagram ammeter analog AC ammeter diagram digital Ammeter circuit ACA5-20RM AC digital voltmeter and ammeter TRANSFORMER CT 5A ammeter DATA SHEET
Text: ACA5-20RM Series www.murata-ps.com True-rms-AC Ammeters with 5A CT Inputs FEATURES • Scales and displays the true-rms output of 5A current transformers ■ Accurately measure complex ac current waveforms ■ Perfect for measuring current in IT applications
|
Original
|
PDF
|
ACA5-20RM
85-140Vac
170-264Vac
50/60Hz)
DIGITAL ammeter block diagram
AC ammeter diagram
AC ammeter and ct diagram
ammeter
analog AC ammeter diagram
digital Ammeter circuit
AC digital voltmeter and ammeter
TRANSFORMER CT 5A
ammeter DATA SHEET
|
PR201ACV
Abstract: BSEN61010-1 BSEN61010-2-031 BSEN61010-2-032 PR 200 current probe
Text: Current Probe Model PR 201ACV The PR 201ACV current probe has been designed for use with multimeters, recorders, power analysers, safety testers etc. for accurate non intrusive measurement of AC current. Using the latest transformer technology, the PR 201ACV can measure currents
|
Original
|
PDF
|
201ACV
201ACV
10kHz.
100pF
BSEN61010-1:
BSEN61010-2-032:
BSEN61010-2-031:
PR201ACV
BSEN61010-1
BSEN61010-2-031
BSEN61010-2-032
PR 200 current probe
|
Untitled
Abstract: No abstract text available
Text: ACA5-20RM Series www.murata-ps.com True-rms-AC Ammeters with 5A CT Inputs C FEATURES Scales and displays the true-rms output of 5A current transformers Accurately measure complex ac current waveforms Perfect for measuring current in IT applications
|
Original
|
PDF
|
ACA5-20RM
85-140Vac
170-264Vac
50/60Hz)
E156931
|
PR230ACV
Abstract: PR230 lem current BSEN61010-1 BSEN61010-2-031 BSEN61010-2-032 LEM current transformer
Text: Current Probe Model PR230 ACV The PR230 ACV current probe has been designed for use with oscilloscopes for accurate non intrusive measurement of AC current. Using the latest transformer technology, the PR230 ACV can measure currents from 100mA to 300A over a frequency range of 40Hz to
|
Original
|
PDF
|
PR230
100mA
40kHz.
100pF
BSEN61010-1:
BSEN61010-2-032:
BSEN61010-2-031:
PR230ACV
lem current
BSEN61010-1
BSEN61010-2-031
BSEN61010-2-032
LEM current transformer
|
zero flux current sensor
Abstract: current sensor Open Loop hall sensor hall effect current sensor ic "Current Sensor" eddy current Sensor Current sensor and Hall sensor SENSOR CURRENT TRANSFORMER hall current sensor ic hall effect sensor 44
Text: Current Sensor Information Page Hall-Effect Current Sensor Features: w w w. t a m u r a c o r p . c o m Current Transformer Features: • Measure: DC, AC, and Pulsed waveforms • Measures AC only • Electrical Isolation • Galvanic Isolation • Fast Response
|
Original
|
PDF
|
|
AC ammeter and ct diagram
Abstract: AC ammeter diagram analog AC ammeter diagram SENSOR CURRENT TRANSFORMER 0-200 AC digital voltmeter and ammeter digital Ammeter circuit DIGITAL ammeter block diagram AC ammeter with Digital Display diagram measure current toroid digital AC Ammeter
Text: ACA5-20RM Series True-rms-AC Ammeters with 5A CT Inputs FEATURES N Scales and displays the true-rms output of 5A current transformers N Accurately measure complex ac current waveforms N Perfect for measuring current in IT applications N Available in three input ranges: 0-100A, 0 to 200A,
|
Original
|
PDF
|
ACA5-20RM
85-140Vac
170-264Vac
50/60Hz)
AC ammeter and ct diagram
AC ammeter diagram
analog AC ammeter diagram
SENSOR CURRENT TRANSFORMER 0-200
AC digital voltmeter and ammeter
digital Ammeter circuit
DIGITAL ammeter block diagram
AC ammeter with Digital Display diagram
measure current toroid
digital AC Ammeter
|
POTENTIAL TRANSFORMERS
Abstract: AAC current transducer
Text: Data Stream RS485 Digital Current Transducer The CRD4100 Series Data Stream Digital Current Transducers are designed for applications where AC current waveforms are not purely sinusoidal. The digital technology is used to measure voltage, current, power frequency and energy in single and three phase
|
Original
|
PDF
|
RS485
CRD4100
CRD4110
Applica50
CRD4110
CRD4170
CRD4150
POTENTIAL TRANSFORMERS
AAC current transducer
|
Untitled
Abstract: No abstract text available
Text: Isolated, Process Current Input 5B42 FEATURES Isolated Current Input. Interfaces with two-wire transmitters, providing an isolated, regulated 20 V supply voltage. Measure process-current input signal of 4-20 mA . Generates an output of +1 to +5V or +2 to 10V.
|
Original
|
PDF
|
D00258-0-9/04
|
5B01
Abstract: 5B42 5B42-01 5B42-02 EN50081-2 EN50082-1
Text: Isolated, Process Current Input 5B42 FEATURES Isolated Current Input. Interfaces with two-wire transmitters, providing an isolated, regulated 20 V supply voltage. Measure process-current input signal of 4-20 mA . Generates an output of +1 to +5V or +2 to 10V.
|
Original
|
PDF
|
D00258-0-9/04
5B01
5B42
5B42-01
5B42-02
EN50081-2
EN50082-1
|
|
Untitled
Abstract: No abstract text available
Text: Current Sense Resistors.qxd 21/1/02 9:44 am Page 3 Resistive Components Current Sense Resistors The need to measure the flow of current in electronic systems is becoming increasingly widespread. Reasons for this include the growth of battery-powered portable products, increasing concern to
|
Original
|
PDF
|
|
HMC1022
Abstract: Magnetic Field Sensor HMC1001 HMC1021Z magnetic sensor an-201 HMC1021 an-209 honeywell magnetic field measuring differential magnetoresistive sensor electrical field sensor
Text: Magnetic Products MAGNETIC CURRENT SENSING AN–209 OVERVIEW Conductor This application note describes the basic principles using magnetic sensors to measure current, offers several approaches to using MR technology, and lists the technical advantages and disadvantages to each approach. Since
|
Original
|
PDF
|
AN-201:
HMC1022
Magnetic Field Sensor
HMC1001
HMC1021Z
magnetic sensor an-201
HMC1021
an-209 honeywell
magnetic field measuring
differential magnetoresistive sensor
electrical field sensor
|
inductive loop sensor
Abstract: Hall-Effect-Sensor HCT-1000-SH PLC inductive sensor "Current Sensors" Current Sensors
Text: HIGH QUALITY INDUCTIVE COMPONENTS PREMO Current Sensors accurately measure up to 1000 Amps. Closed-loop Hall Effect sensors offer high performance and excellent linearity. PREMO enhances its current sensors product range with the newest HCT-1000-SH series, a high
|
Original
|
PDF
|
HCT-1000-SH
com/in/file/604
com/in/technology/sector/24/
inductive loop sensor
Hall-Effect-Sensor
PLC inductive sensor
"Current Sensors"
Current Sensors
|
Untitled
Abstract: No abstract text available
Text: Current-Sense_AN_C.qxd 5/11/04 10:29 AM Page 3 Resistive Components Current Sense Resistors The need to measure the flow of current in electronic systems is becoming increasingly widespread. Reasons for this include the growth of battery-powered portable products, increasing concern to
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Data Stream RS485 Digital Current Transducer DIN RAIL / PANEL MOUNT The CRD4100 Series Data Stream Digital Current Transducers are designed for applications where AC current waveforms are not purely sinusoidal. The digital technology is used to measure voltage, current, power frequency and energy in single and three phase
|
Original
|
PDF
|
RS485
CRD4100
CRD4110
CRD5170
|
Untitled
Abstract: No abstract text available
Text: Data Stream RS485 Digital Current Transducer DIN RAIL / PANEL MOUNT The CRD4100 Series Data Stream Digital Current Transducers are designed for applications where AC current waveforms are not purely sinusoidal. The digital technology is used to measure voltage, current, power frequency and energy in single and three phase
|
Original
|
PDF
|
RS485
CRD4100
CRD4110
|
M235A
Abstract: cm485a DWA01CM235A PWA01CM235A PWA01CM48 aSYNCHRONOUS MOTOR WIRING
Text: Monitoring Relays 3-Phase Load Guard Types DWA01, PWA01 DWA01 • Cos ϕ monitoring relays • Measuring if power factor is within set limits • Measure on own power supply voltage and current for balanced systems • Measuring ranges for current: 5A and MI current
|
Original
|
PDF
|
DWA01,
PWA01
DWA01
DWA01)
PWA01)
DWA01
PWA01
M235A
cm485a
DWA01CM235A
PWA01CM235A
PWA01CM48
aSYNCHRONOUS MOTOR WIRING
|
Untitled
Abstract: No abstract text available
Text: Document 134 50/60 Hz Current Sensors – CS60 Series The CS60 series is designed to measure current from 5 to 100 Arms. Applications include sensing branch circuit overload and detecting load drop or shutdown. The sensor functions as the encapsulated secondary of a current
|
Original
|
PDF
|
CS60-050L
CS60-
|
CS60-075L
Abstract: No abstract text available
Text: Document 134 50/60 Hz Current Sensors – CS60 Series The CS60 series is designed to measure current from 5 to 100 Arms. Applications include sensing branch circuit overload and detecting load drop or shutdown. The sensor functions as the encapsulated secondary of a current
|
Original
|
PDF
|
CS60-050L
CS60-075L
CS60-100L
|
Untitled
Abstract: No abstract text available
Text: Standard and Custom Designed Current-Sensing Transformers Our toroidal current-sensing transformers measure current flowing in power lines and busbars. Also called instrument transformers, they can be furnished with protective insulation by means of taping, resin dipping or epoxy potting. They can also be cast in
|
OCR Scan
|
PDF
|
|