Untitled
Abstract: No abstract text available
Text: MRC300,DH2,HT,DV Re-circulating Chiller Heating Option Innovative Technology for a Connected World The MRC Series is a bench top re-circulating chiller that offers dependable, compact performance by controlling the temperature of a coolant in a liquid circuit. The coolant
|
Original
|
MRC300
A16311-00
|
PDF
|
Untitled
Abstract: No abstract text available
Text: WL 1500 Liquid to Air Heat Exchanger System Innovative Technology for a Connected World WATER COOLED HEAT EXCHANGER UNITS FOR MEDICAL AND INDUSTRIAL SYSTEMS The WL1500 is a re-circulating liquid to air heat exchanger that offers dependable, compact performance by removing large amounts of heat from a liquid circuit. The coolant is
|
Original
|
WL1500
|
PDF
|
Untitled
Abstract: No abstract text available
Text: WL 500 Liquid to Air Heat Exchanger System Innovative Technology for a Connected World WATER COOLED HEAT EXCHANGER UNITS FOR MEDICAL AND INDUSTRIAL SYSTEMS The WL500 is a re-circulating liquid to air heat exchanger that offers dependable, compact performance by removing large amounts of heat from a liquid circuit. The coolant is
|
Original
|
WL500
|
PDF
|
Untitled
Abstract: No abstract text available
Text: 2429 FLUID DETECTOR OUTPUT OUTPUT NO CONNECTION SUPPLY GROUND DECOUPLING GROUND DECOUPLING OSCILLATOR DECOUPLING DET. INPUT OSC. OUTPUT OSCILLATOR RREF D w g. No. PS Primarily designed for use as an automotive low coolant detector, the ULN2429A monolithic bipolar integrated circuit is ideal for detecting
|
OCR Scan
|
ULN2429A
|
PDF
|
4CPL1000A
Abstract: No abstract text available
Text: This tube is designed for immersion in cooling a liquid dielectric and can dissipate 1,000 watts. In air with proper cooling, plate dissipation is 300watts. The 4CPL1000A mounting is optional. This tube is rated to operate at an anode potential up to 15 kVdc when immersed in the recommended coolant. When immersed, the rating is not
|
Original
|
300watts.
4CPL1000A
CPL1000A
4CPL1000A
|
PDF
|
CF78-UL-15-12
Abstract: eplan
Text: CF78.UL PUR 6.8-7.5xd Fine-wire stranded conductor PUR Control cable Chainflex CF78.UL l for high load requirements l PUR outer jacket l oil-resistant and coolant-resistant l flame-retardant l notch-resistant l PVC-free/halogen-free [°C] R [°C] R v R a
|
Original
|
eu/en/CF78
CF78-UL-15-12
eplan
|
PDF
|
EN60228
Abstract: CF77-UL DIN 47100
Text: EU-CHAINFLEX-INHALT 06-09 CF77.UL.D PUR 6.8-7.5xd 21.05.2009 19:09 Uhr Seite 70 PUR Control cable Chainflex CF77.UL.D l for high load requirements l PUR outer jacket l oil-resistant and coolant-resistant l flame-retardant l notch-resistant l PVC-free/halogen-free
|
Original
|
2006/95/EG
EN60228
CF77-UL
DIN 47100
|
PDF
|
ntc 2251
Abstract: 097k AB Elektronik 94097 coolant temperature sensor
Text: Temperature Sensor Type 94097.K Technical data Type 94 097.K Application: Coolant water, motor oil Installation: Screw on sensor with thread M 12,5 x 1,5 or M 14,5 x 1,5 Sensor: NTC Resistance acc. to nominal line: R 25°C = 2251,0 ž; R(100°C) = 153,1 ž ± 1%
|
Original
|
|
PDF
|
12162193
Abstract: PBT 30 gf black
Text: COOLANT/FLUID Sensors L E A ED S S S B E AL E D 8.3 Dia. A C H: 22.2 28.8 Probe Length 27.4 Exposed Length W: 21.3 L: 29.0 Total Mated Length: 67.87mm A PART NO: B PART NO: 15336004 Shrouded 15336024 (Unshrouded) DESCRIPTION: 150 GT Connector Assembly 2F
|
Original
|
25mW/Ë
1-800-PACKARD
12162193
PBT 30 gf black
|
PDF
|
FLUID DETECTOR
Abstract: No abstract text available
Text: FLUID DETECTOR Primarily designed for use as an automotive low coolant detector, the ULN2429A monolithic bipolar integrated circuit is ideal for detect ing the presence or absence of many different types of liquids in automotive, home, or industrial applications. Especially useful in harsh
|
OCR Scan
|
ULN2429A
FLUID DETECTOR
|
PDF
|
Untitled
Abstract: No abstract text available
Text: LUBE/COOLANT FLOW MONITORS CAPACITY: 1 to 20 GPM ߜ ±5% Full Scale Accuracy ߜ ±1% Reading Repeatability ߜ Built-in Signal Switch ߜ Stainless Steel and Teflon and Aluminum Wetted Parts ߜ For Coolants or Lubricants with 0.84 Specific Gravity ߜ Designed for Use
|
Original
|
FL-O10
FL-O15
FL-O20
FL-O15,
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Advantages Applications Typical applications that benefit from using current sense resistors include: • General Use • Power Supplies Disk Drives Battery Power Management • Transportation Speed Sensor Parking Sensor Engine coolant temperature sensor
|
Original
|
UR010
CSR2010/RMCF2010
PR1206
LRC-LRF2010
RCWL0201/CRCW0201
WSC2010/WSL2010
CNSL1206
RCWE2010
MCR50
LRC-LR2010
|
PDF
|
Untitled
Abstract: No abstract text available
Text: WL 2000 Liquid to Air Heat Exchanger System Innovative Technology for a Connected World WATER COOLED HEAT EXCHANGER UNITS FOR MEDICAL AND INDUSTRIAL SYSTEMS The WL2000 is a re-circulating liquid to air heat exchanger that offers dependable, compact performance by removing large amounts of heat from a liquid circuit. The coolant is recirculated using a high pressure pump to assure maximum flow rate. Heat from coolant is
|
Original
|
WL2000
|
PDF
|
4040PC250G5D
Abstract: 4040PC250G4D 4040PC150G4D packard 12078090 12078090 4000PC 4040PC015G5D 4040PC100G4D 4040PC015G4D 4040PC100G5D
Text: Pressure Sensors 4000PC Series M onolithic Signal Conditioned N Eur^r FEATURES • Operating tem perature range - 4 5 ° to +125°C - 4 9 ° to +257°F • M onolithic design • C om patible with media fro m d ry airand water to refrigerant coolants and en
|
OCR Scan
|
4000PC
PC-15191
4040PC250G5D
4040PC250G4D
4040PC150G4D
packard 12078090
12078090
4040PC015G5D
4040PC100G4D
4040PC015G4D
4040PC100G5D
|
PDF
|
|
PC-15191
Abstract: 4040PC015G4D 4040PC150G5D
Text: Pressure Sensors Monolithic Signal Conditioned 4000PC Series FEATURES ɀ Operating temperature range – −45° to +125°C −49° to +257°F ɀ Monolithic design ɀ Compatible with media from dry air and water to refrigerant coolants and engine fuels ɀ 0.2% accuracy
|
Original
|
4000PC
PC-15191
4040PC015G4D
4040PC150G5D
|
PDF
|
15366022
Abstract: 121463 12162193
Text: COOLANT/FLUID Sensors L E A ED S S S E AL E D DESCRIPTION Coolant/Fluid temperature sensors are continuous function devices that change resistance inversely proportional to temperature. These brass sensors consist of five major components: the brass shell, thermal grease,
|
Original
|
1-800-PACKARD
15366022
121463
12162193
|
PDF
|
coolant temperature sensor
Abstract: No abstract text available
Text: Temperature Sensor Type 94097 With connecting tube 12; 15 or 19 mm Technical data Type 94 097 Application: Coolant water Installation: Plug in sensor with fixed catching Sensor: NTC Resistance acc. to nominal line: R 25°C = 2252,0 ž; R(20°C) = 2813,0 ž; R(80°C) = 282,9 ž
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: FLUID DETECTOR Primarily designed for use as an automotive low coolant detector, the ULN2429A monolithic bipolar integrated circuit is ideal for detecting the presence or absence of many different types of liquids in automo tive, home, or industrial applications. Especially useful in harsh environ
|
OCR Scan
|
ULN2429A
18ki2
|
PDF
|
a1347
Abstract: Switches A1341 7400
Text: Switches and Pushbuttons Coolants Page ftn lM w i and pushbuttons for printed circuits S8de switches A88 SWe switches A80 DuaMn-Rne switches A1341 DuaWn-line switches A3000 Stngie-deck rotary switches/Rotary pulse generator A1353 Pushbutton switches A60 DIP-FIX linka/Switches A1347
|
OCR Scan
|
A1341
A3000
A1353
A1347
A23001-G23-D009-X-7400
Switches
7400
|
PDF
|
Untitled
Abstract: No abstract text available
Text: WL 5000 Liquid to Air Heat Exchanger System Innovative Technology for a Connected World WATER COOLED HEAT EXCHANGER UNITS FOR MEDICAL AND INDUSTRIAL SYSTEMS The WL 5000 is a re-circulating liquid to air heat exchanger that offers dependable, compact performance by removing large amounts of heat from a liquid circuit. The coolant is recirculated using a high pressure pump to assure maximum flow rate. Heat from coolant is
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: MRC150,DH2,DV Re-circulating Chiller Innovative Technology for a Connected World The MRC Series is a bench top re-circulating chiller that offers dependable, compact performance by controlling the temperature of a coolant in a liquid circuit. The coolant is re-circulated using a pump with high MTBF. Heat from coolant is absorbed by a heat
|
Original
|
MRC150
A16311-00
|
PDF
|
SID10ADBFPKG
Abstract: SI1010 nbr shore 80 PBT-GF20 nbr shore a 80 D-45127
Text: Flow monitors SI1010 SID10ADBFPKG/US Compact type for adapter Plug and socket 1: internal thread M18x1.5, 2: setting push buttons, 3: LED display Application Electrical design Output Setting range [cm/s] coolant / oils in machine tools DC PNP normally open / closed programmable
|
Original
|
SI1010
SID10ADBFPKG/US
M18x1
316S12)
SI1010
SID10ADBFPKG
nbr shore 80
PBT-GF20
nbr shore a 80
D-45127
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Quality Products. Service Excellence. Water Chillers EB-RACK Series Description Designed to provide recirculated coolant for most industrial applications air/water heat exhangers, process cooling, machine hydraulics or motor cooling. Standards Rack Series - UL,cUL, CE
|
Original
|
EB30-50
EB190-400
RAL7035
Gra34
|
PDF
|
LO-706
Abstract: ULN2429A fluid sensing circuit inductive sensor oscillator circuit ULN2429A-1
Text: FLUID DETECTOR OUTPUT OUTPUT NO CONNECTION SUPPLY GROUND DECOUPLING GROUND DECOUPLING OSCILLATOR DECOUPLING OSC. OUTPUT DET. INPUT OSCILLATOR D w g. P S - 0 1 7 Prim arily designed for use as a n autom otive low coolant detector, the ULN2429A m onolithic bipolar integrated circuit is ideal for detecting
|
OCR Scan
|
ULN2429A)
ULN2429A
10ki2
LO-706
fluid sensing circuit
inductive sensor oscillator circuit
ULN2429A-1
|
PDF
|