pressure safety valves
Abstract: ISO pneumatic standards symbols R1219 hydraulic solenoid valve switch power supply control 5304 double acting hydraulic cylinder solenoid block valve Pressure switch Users Manual control valve
Text: Issued March 1997 232-3434 Data Pack G Data Sheet Compressed air safety and pneumatic Cetop symbols Compressed air safety Compressed air Compressed air, whilst generally considered a safe source of energy, must always be treated with caution and under no circumstances used for any other purposes than that for which it is intended.
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: ODU-MAC Materials: Insulation Body: Module for compressed air valve Glass-filled thermoplastic Polyester UL-94 V0 rated Cu-Alloy blank 6 bar Compressed Air Valve: Contact Finish: Air Pressure: Socket Module, 2 Pos. Pin Module, 2 Pos. Plugging Direction 13
|
Original
|
PDF
|
UL-94
18ging
D-84453
|
norgren pressure gauge
Abstract: NORGREN -HERION vacuum pump Norgren 5811
Text: M/58112/09 Vacuum Pump - 0,85 bar ● Compact dimensions ● Compressed air driven ● Low sound level ● Easy installation Technical Data Ordering Information Medium: Compressed air, filtered and non-lubricated Operation: Single stage ejector Operating Pressure:
|
Original
|
PDF
|
M/58112/09
norgren pressure gauge
NORGREN -HERION
vacuum pump
Norgren
5811
|
M-58102-60
Abstract: norgren pressure gauge norgren silencer silence NORGREN -HERION pneumatic pumps norgren 110 M-58102-20 NORGREN -HERION 58102 60 vacuum tube 80
Text: M/58102 Vacuum Pumps - 0,87 bar ● Small, compact units ● Compressed air driven ● Simple to install Technical Data Ordering Information Medium: Compressed air, filtered and non-lubricated Operation: Multi ejector system Operating Pressure: 6 bar maximum
|
Original
|
PDF
|
M/58102
M/58102/10
M/58102/30
M/58102/60
M/58102/120
M-58102-60
norgren pressure gauge
norgren silencer
silence
NORGREN -HERION
pneumatic pumps
norgren 110
M-58102-20
NORGREN -HERION 58102 60
vacuum tube 80
|
rexroth
Abstract: frl 263 Bosch pressure air bosch bosch air flow
Text: Bosch Rexroth AG | Pneumatics Preparation of compressed air - FRL ¬ Filter, series NL1 Qn = 1000 l/min, filter porosity: 5 µm Ambient temperature min. / max. Version Filter reservoir volume Medium compressed air acc. to ISO 8573-1:2001 materials: Housing
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Conduit Systems M24758/1 EMI/EMP Shielding Conduit M24758/1-16-F Standard Brass, Compressed Brass and FEP Core Designator: See Note 1 Omit for uncomprssed brass F = FEP C = Compressed Brass Basic Part No. Conduit Size Code Wire Overbraid Weather Jacket Core
|
Original
|
PDF
|
M24758/1
M24758/1-16-F
|
Untitled
Abstract: No abstract text available
Text: WDD 81V - Desoldering Station Set Bestellnr.:0053256699 Desoldering station diigital 95 W, 230 V compressed air or inert gas operated Top Attributes • 1 channel • Digital controlled electronic for soldering or desoldering tools up to 80 W • Compressed air converter provides vacuum for the desoldering iron
|
Original
|
PDF
|
|
AC491-CB
Abstract: AC491064-CB AC491 AC491030-CB AC491064 voice activity detection G.711, G.723.1, G.726, G.728 AUDIOCODES
Text: AudioCodes Enabling Technology Products AC491xxx High Density Voice over Packet Processor Family The AC491xxx family of DSPs is an ideal solution for high density, carrier class Voice over IP gateways. Featuring high channel density up to 240 channels of non-compressed voice, or 120 channels of compressed voice ,
|
Original
|
PDF
|
AC491xxx
AC491xxx
16x16
AC491-CB
AC491064-CB
AC491
AC491030-CB
AC491064
voice activity detection
G.711, G.723.1, G.726, G.728
AUDIOCODES
|
NORGREN -HERION
Abstract: Norgren 58022 pneumatic component Vacuum Switch 4310-101
Text: M/58021, M/58022 Pneumatic Vacuum Switches ● Quick, easy installation ● Converts vacuum signal into compressed air output Technical Data Ordering Information Medium: Air filtered and non-lubricated Operation: M/58021 Normally open M/58022 Normally closed
|
Original
|
PDF
|
M/58021,
M/58022
M/58021
NORGREN -HERION
Norgren
58022
pneumatic component
Vacuum Switch
4310-101
|
solenoid valve electro-pneumatic
Abstract: No abstract text available
Text: Pneumatic logic components www.crouzet.com 41 General characteristics Operating fluid - Compressed air or inert gas. flow graphs Conditions of use - Operating pressure 2 at 8 bars except for special conditions . - Fluid: Filtered air to 50 microns - non lubricated.
|
Original
|
PDF
|
|
rexroth
Abstract: pressure air bosch pressure regulator Bosch 30076 bosch air flow rexroth regulator Bosch air pressure BOSCH 0 2 semi-automatic
Text: Bosch Rexroth AG | Pneumatics Preparation of compressed air - FRL ¬ Filter pressure regulator, series NL1 Qn = 950 l/min, filter porosity: 5 µm Controller version Ambient temperature min. / max. Controller version Filter version Filter reservoir volume
|
Original
|
PDF
|
M30x1
rexroth
pressure air bosch
pressure regulator
Bosch
30076
bosch air flow
rexroth regulator
Bosch air pressure
BOSCH 0 2
semi-automatic
|
manometer
Abstract: Q 371 Transistor 50.880.00.20.00 pressure signal with knock pressure regulator 914G1
Text: Druckluftaufbereitung Conditioning of Compressed Air Druckregler mit Gewindeanschluß G1/8 Pressure Regulator with G1/8 Connection Der universal einsetzbare Druckregler zeichnet sich durch eine sehr gute Regelcharakteristik aus und ermöglicht einen großen Volumenstrom. Die rechteckige
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Weller Digital 700W Hot Air Station For Operation With Compressed Air Product Details Catalog No. UPC Code Wattage Desoldering Pencil s Temperature Range Voltage Supplied Tip(s) Air Flow Volume Pump Type Packaging Literature Low Res. Image High Res. Image
|
Original
|
PDF
|
WHA3000V
WHA3000V
WHA3000P
AKT30
|
manometer
Abstract: KUHNKE kuhnke 114 G1-8 50686 CM335 fluid manometer 50738 33-/33-/P110
Text: Druckluftaufbereitung Conditioning of Compressed Air Wartungseinheiten G1/8, G1/4, G3/8, G1/2, G1 Die Wartungseinheiten dienen zur Aufbereitung der Luft und gewährleisten zuverlässiges Arbeiten aller nachgeschalteten pneumatischen Geräte. Sie haben wesentlichen Anteil an der Lebensdauer von
|
Original
|
PDF
|
wirtschaftlich1/50
manometer
KUHNKE
kuhnke 114
G1-8
50686
CM335
fluid manometer
50738
33-/33-/P110
|
|
Untitled
Abstract: No abstract text available
Text: DPC-30 Pneumatic Calibration System Specifications Small, lightweight, and accurate — take your test bench to the field! Pressure Ranges Accuracy Engineering Units Modes Electrical Ranges Features Works with compressed plant air 0.001 PSI resolution, ±0.035% accuracy
|
Original
|
PDF
|
DPC-30
DPC-30
A/10-50
Temper12
021202R0/OEMM/1M
|
TC94A60MFG
Abstract: TC94A60MFG-301 tc94a5 TC94A54MFG TC94A54MFG-001 tc94a54mf
Text: Product Brief TC94A54MFG/TC94A60MFG Single-chip CD-MP3 Solution Highlights Description • Highly integrated TC94A54MFG and TC94A60MFG are highly integrated, high-performance CDMP3 solutions that enable playback of CD and multiple compressed audio formats
|
Original
|
PDF
|
TC94A54MFG/TC94A60MFG
TC94A54MFG
TC94A60MFG
VDD15
VSS15
TC94A60MFG-301
tc94a5
TC94A54MFG-001
tc94a54mf
|
bosch torque sensor
Abstract: rexroth temperature sensor rexroth R4800 R480052300 R480052298 R480052297 R412003617 M22X1 integrated circuit BOSCH
Text: Bosch Rexroth AG | Pneumatics Piston rod cylinders ¬ Mini cylinder, series OCT Ø 10 - 25 mm, double-acting, magnetic piston, cushioning rings, piston rod: rotatable Working pressure min/max Ambient temperature min. / max. Medium compressed air acc. to ISO 8573-1:2001
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Weller Compressed Air - Cleaning Filter Product Details Catalog No. T0058735757 UPC Code 037103237057 Fits Tool s WFE Description Exhaust Filter Packaging Industrial Box/Carton Stock Item Made to Order-Call for Lead Time Package Details (Dimensions) Product Features:
|
Original
|
PDF
|
T0058735757
|
Untitled
Abstract: No abstract text available
Text: MANUAL AND AUTOMATED PLASTIC VALVES Ball and Diaphragm Versions From $ 19 MADE IN USA OMEGA offers a wide selection of plastic valves suitable for liquid service not for use in compressed air service . SPECIFICATIONS Fluid Temperature/Pressure Range: NOTE: All pressure/temperature ratings
|
Original
|
PDF
|
FVL5305-CLC
FVL5307-CLC
FVL5310-CLC
FVL5312-CLC
FVL5315-CLC
FVL5320-CLC
FVL5312-CLC,
|
cushion
Abstract: HCM Series stk 018 STK 027 STK 040 1 4 wire proximity cma* relay double acting cylinder MDC2
Text: High energy absorption cylinder, double acting/single rod type HCM Series • Bore size: 20, 25, 32, 40, 50, 63 mm JIS symbol Specifications Descriptions Bore size HCM mm 20 dia. 25 dia. 32 dia. 40 dia. Double acting Compressed air Actuation Working fluid
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: “SNAP-IN” FITTINGS FOR FLEXIBLE AND COPPER TUBING OMEGA Connectors For Use In… ◆ Food Service ◆ Research and Industrial Laboratories ◆ Fluid Applications ◆ Compressed Air ◆ Plastic and Copper Tubing Applications OMEGA® fittings and color-coded caps are
|
Original
|
PDF
|
mod32"
10/PK)
FT-138120-S
L-126
|
BOSCH 0821302727
Abstract: rexroth compressed air pressure air bosch Bosch 5.4 0821302 Bosch bosch air flow 30272 rexroth regulator
Text: Bosch Rexroth AG | Pneumatics Preparation of compressed air - FRL ¬ Pressure regulator, series NL1 Qn = 600 l/min 00107353 Version Diaphragm-type pressure regulator Working pressure min/max Ambient temperature min. / max. Medium - / 16 bar -10°C / +50°C
|
Original
|
PDF
|
082130273al
M30x1
BOSCH 0821302727
rexroth
compressed air
pressure air bosch
Bosch 5.4
0821302
Bosch
bosch air flow
30272
rexroth regulator
|
Norgren
Abstract: No abstract text available
Text: SP HJ NORGREN M/58102 Vacuum Pumps - 0,87 bar • Small, compact units • Compressed air driven • Simple to install Technical Data Ordering Information Medium: Compressed air, filtered and non-lubricated To order a vacuum pump with 80 Nl/min induced air at 6 bar operating pressure
|
OCR Scan
|
PDF
|
M/58102
M/58102/10
M/58102/30
M/58102/60
M/58102/120
M/58102/30
Norgren
|
Untitled
Abstract: No abstract text available
Text: HJSP NORGREN M/58021, M/58022 Pneumatic Vacuum Switches • Quick, easy installation • Converts vacuum signal into compressed air output Technical Data Ordering Information Medium: Air filtered and non-lubricated To order a pneumatic vacuum switch normally open
|
OCR Scan
|
PDF
|
M/58021,
M/58022
M/58021
M/58022
M/58021
|