NNC25X37LG2
Abstract: Wiring Duct NNC100X100LG2 NNC25X25LG2
Text: ELECTRICAL SOLUTIONS A. System Overview Panduct Type NNC Halogen-Free Metric Wiring Duct • Material: Halogen-free modified polyphenylene oxide mPPO material as verified with IEC 60754-2 test method (test on gases evolved during combustion of electric cables)
|
Original
|
NNC25X25LG2
NNC25X37LG2
NNC25X50LG2
NNC25X75LG2
NNC37X37LG2
NNC50DWH2
NNC75DWH2
Wiring Duct
NNC100X100LG2
|
PDF
|
HF625
Abstract: No abstract text available
Text: 3M Round Conductor Flat Cable 1 mm 28 AWG Stranded, Halogen Free PO HF625 Series • Low Smoke Zero Halogen LSZH . Insulation Advantages of LSZH insulation are the low smoke (IEC 61034-2:2005), and low toxicity of combustion gases (NF X 70-100-2:2006), reducing the
|
Original
|
HF625
RIA-2217B-E
|
PDF
|
Untitled
Abstract: No abstract text available
Text: 3M Twisted Pair Flat Cable .050" 28 AWG Stranded, Mass Terminable, Halogen Free Polyolefin 2100 Series H F1 Se r ie s • Advantage of this halogen free insulation are low smoke BSS 7238 and low toxicity of combustion gases (NES 713) reducing the risk to firefighters and
|
Original
|
RIA-2217B-E
|
PDF
|
diesel injector bosch
Abstract: common rail injector test Common rail injector Technical data peak and hold diesel bosch injectors Common rail injector peak and hold gasoline direct injection TLE6240 bosch diesel injector common rail pressure sensor bosch
Text: Application Note, V 2.0, Sept. 2001 AP3229 TC1775 Pe ak & H old Curr en t Shape g ene ra te d by TriC ore der iva tive TC17 75 This application note focuses on the generation of a Peak&Hold current shape for Direct Injection Combustion Engines by using the 32-bit TriCore derivative TC1775.
|
Original
|
AP3229
TC1775
32-bit
TC1775.
diesel injector bosch
common rail injector test
Common rail injector Technical data
peak and hold diesel
bosch injectors
Common rail injector
peak and hold gasoline direct injection
TLE6240
bosch diesel injector
common rail pressure sensor bosch
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Photocells B 1060, V 1060 Metal housing TO types Street Light control Combustion control This range of Photocells includes metal housings in 2 different sizes, TO8 and TO-5. Operating Temperature Range: -20.+70 °C non continuous Storage Temperature Range:
|
Original
|
|
PDF
|
D1160-12
Abstract: BURNER oil burner D1160
Text: | Sensors | D A T A S H E E T Sensor systems Lighting p Oil Burner Control Applications Photocells D 1160, D 1172, W 5560 Glass encapsulated housing Combustion Control Applications This Data show two different glass encapsulated photocells in various selections.
|
Original
|
W5560
D1160-12
BURNER
oil burner
D1160
|
PDF
|
ultracapacitor Charger
Abstract: boostcap internal combustion engine BCAP0007 bosch dc dc converter HTA 200-S maxwell diagram bosch capacitor car starter motor ultracapacitor
Text: APPLICATION NOTE Document 1007240 Rev 2 1 of 6, 07/03 BOOSTCAPs Start Internal Combustion Engine Since original publication of this document, further enhancements have been made to ultracapacitor technology enabling improved performance over that listed within
|
Original
|
CH1728
ultracapacitor Charger
boostcap
internal combustion engine
BCAP0007
bosch dc dc converter
HTA 200-S
maxwell diagram
bosch capacitor
car starter motor
ultracapacitor
|
PDF
|
The Next Big Thing For Discrete RF Semiconductors: Health Care
Abstract: blood pressure sensors glucose
Text: The Next Big Thing For Discrete RF Semiconductors: Health Care By Rick Cory, Skyworks Solutions, Inc. Literature and popular culture abound with predictions: “voice recognition software will make computer keyboards obsolete by 2009,” “vehicles with internal combustion engines will be obsolete by 2012,” and
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: 3M Round Conductor Flat Cable .025" 30 AWG Solid, Halogen Free Insulation 2049 Series • Advantages of this halogen free insulation are low smoke BSS 7238 and low toxicity of combustion gases (NES 713) reducing risk to firefighters and low corrosivity of combustion gases (pH≈6.0) reducing
|
Original
|
TS-0886-B
RIA-2217B-D
|
PDF
|
keko
Abstract: No abstract text available
Text: AV / AVY Series Stackpole Electronics, Inc. Automotive Leaded Varistor Resistive Product Solutions Description: Almost all electronic systems in internal-combustion powered vehicles, e.g., anti-lock brakes, direct ignition, airbag control, wiper motors, etc. are
|
Original
|
|
PDF
|
smd code avy
Abstract: AV30K2220
Text: Stackpole Electronics, Inc. AV / AVY Series Resistive Product Solutions Automotive SMD Varistor Description: Almost all electronic systems in internal-combustion powered vehicles, e.g., anti-lock brakes, direct ignition, airbag control, wiper motors, etc. are
|
Original
|
180mm
330mm
smd code avy
AV30K2220
|
PDF
|
Untitled
Abstract: No abstract text available
Text: AV / AVY Series Stackpole Electronics, Inc. Automotive Leaded Varistors Resistive Product Solutions Description: Almost all electronic systems in internal-combustion powered vehicles, e.g., anti-lock brakes, direct ignition, airbag control, wiper motors, etc. are
|
Original
|
|
PDF
|
AV14K1210
Abstract: AV30K1206 AV20K AV30K1210 AV30K2220
Text: AV / AVY Series Stackpole Electronics, Inc. Resistive Product Solutions Automotive SMD Varistor Description: Almost all electronic systems in internal-combustion powered vehicles, e.g., anti-lock brakes, direct ignition, airbag control, wiper motors, etc. are susceptible to damage from destructive
|
Original
|
|
PDF
|
REC 670
Abstract: 1411D
Text: Quality is our message Z-TRAP FUJI Ceramic Surge Absorbers ENF series 220 to 680V Varistor voltage Features • Flame-resistant Suppress combustion and smoking after a malfunction caused by larger surge than the specified value · Environment-friendly materials
|
Original
|
50Hz/60Hz
ENF221D05A
ENF241D05A
ENF271D05A
ENF471D05A
ENF221D07A
ENF241D07A
ENF271D07A
ENF471D07A
ENF221D10A
REC 670
1411D
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: 3M Round, Jacketed, Flat Cable .050" 28 AWG Stranded, Mass-Term, Halogen Free PO/PO HF759 Series • Low Smoke Zero Halogen LSZH Insulation. Advantages of LSZH insulation are the low smoke (IEC 61034-2:2005), and low toxicity of combustion gases (NF X 70-100-2:2006), reducing the
|
Original
|
HF759
RIA-2217B-E
|
PDF
|
Untitled
Abstract: No abstract text available
Text: 3M Round Conductor Flat Cable .050" 28 AWG Stranded, Halogen-Free Insulation 2010 Series • Advantage of this halogen free insulation are low smoke BSS 7238 and low toxicity of combustion gases (NES 713) reducing the risk to firefighters and low corrosivity of combustion gases (pH
|
Original
|
RIA-2217B-E
|
PDF
|
2220 smd
Abstract: airbag
Text: AV Series – Automotive SMD Varistors Multilayer Technology Varistor Plus Description Almost all electronic systems in internal-combustion powered vehicles, e.g, anti-lock brakes, direct ignition, airbag control, wiper motors, etc. are susceptible to damage from destructive voltage
|
Original
|
|
PDF
|
varistor Z 500 ps
Abstract: K 1206 airbag v 14 k 320 varistor
Text: $9 6HULHV ± $XWRPRWLYH 60' 9DULVWRUV Multilayer Technology Varistor Plus Description Almost all electronic systems in internal-combustion powered vehicles, e.g, anti-lock brakes, direct ignition, airbag control, wiper motors, etc. are susceptible to damage from destructive voltage
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: AV Series – Automotive Leaded Varistors Multilayer Technology Varistor Plus Description Almost all electronic systems in internal-combustion powered vehicles, e.g., anti-lock brakes, direct ignition, airbag control, wiper motors, etc. are susceptible to damage from destructive
|
Original
|
|
PDF
|
flame detector burner
Abstract: FAU810 safe flame dfs flame detector SF810 relay failure analysis DETECTOR FLAME flame scanner BURNER UVISOR
Text: System 800xA for Power Generation UvisorTM FAU 810 – Flame Analysis Unit 800 Series Combustion Instruments Flexible and Reliable Device for use with all ABB Flame Detectors The Flame Analysis Unit, or FAU810, is ABB’s latest leading-edge flame analysis device.
|
Original
|
800xA
FAU810,
FAU810
9AKK101130D9837-D
flame detector burner
safe flame dfs
flame detector
SF810
relay failure analysis
DETECTOR FLAME
flame scanner
BURNER
UVISOR
|
PDF
|
K 1206
Abstract: av tvs http no smd code 201 K1210 smd code avy airbag
Text: AV / AVY Series — Automotive SMD Varistors Description Almost all electronic systems in internal-combustion powered vehicles, e.g, anti-lock brakes, direct ignition, airbag control, wiper motors, etc. are susceptible to damage from destructive voltage transients.
|
Original
|
Rev10/07
K 1206
av tvs http no
smd code 201
K1210
smd code avy
airbag
|
PDF
|
Untitled
Abstract: No abstract text available
Text: 12343125367897A3 Stackpole Electronics, Inc. Automotive SMD Varistor Resistive Product Solutions Description: Almost all electronic systems in internal-combustion powered vehicles, e.g., anti-lock brakes, direct ignition, airbag control, wiper motors, etc. are
|
Original
|
12343125367897A3
180mm
330mm
|
PDF
|
SF810
Abstract: safe flame dfs uv flame sensor 9AKK101130D4742 UV LED 280NM SF810I SF810-FO-Q-XXXX-mm C99-94510 EN854 steam boiler ignitor
Text: System 800xA for Power Generation Uvisor SF810i Multi Fuel Integrated Safe Flame Scanner 800 Series Combustion Instruments ABB has combined the two highly successful flame scanner product lines, Uvisor™ and Safe Flame DFS, into a new advanced Flame Scanner, the Uvisor™
|
Original
|
800xA
SF810i
SF810i.
SF810i
EN854
84410-S-0400000
84410-S-0400001
84410-S-0400002
9AKK101130D4742-M-
SF810
safe flame dfs
uv flame sensor
9AKK101130D4742
UV LED 280NM
SF810-FO-Q-XXXX-mm
C99-94510
steam boiler ignitor
|
PDF
|
Untitled
Abstract: No abstract text available
Text: HIP9011 HARRIS S E M I C O N D U C T O R Engine Knock Signal Processor January 1998 Features Description • Two Sensor Inputs The HIP9011 is used to provide a method of detecting pre mature detonation often referred to as “Knock or Ping” in internal combustion engines.
|
OCR Scan
|
HIP9011
HIP9011
1-800-4-HARRIS
|
PDF
|