Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    CHANGE OVER RELAY Search Results

    CHANGE OVER RELAY Result Highlights (2)

    Part ECAD Model Manufacturer Description Download Buy
    PQU650M-F-COVER
    Murata Manufacturing Co Ltd PQU650M Series - 3x5 Fan Cover Kit, RoHs Medical Visit Murata Manufacturing Co Ltd
    GRM-KIT-OVER100-DE-D
    Murata Manufacturing Co Ltd 0805-1210 over100uF Cap Kit Visit Murata Manufacturing Co Ltd

    CHANGE OVER RELAY Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    Contextual Info: Datasheet SCO-1421 Intelligent ASI Change-Over with Probing Space-saving, modular platform for advanced signal processing. The SCO-1421 from Grass Valley, a Belden Brand, is a 2x1 intelligent ASI change-over with built-in MPEG-TS probing. Change-overs are performed


    Original
    SCO-1421 SCO-1421 SCO-1421â RCP-200 SCO-1421-DRP-R GVB-1-0404A-EN-DS PDF

    TSC44

    Abstract: automatic change over switch circuit relay POTENTIAL FREE CONTACT tsc44.22
    Contextual Info: Digital time switches - Front panel mounting TSC44 Functions ON/OFF, IMPULS and MANUAL Daily- and weekly program Automatic summertime change over Unrestricted block-programming 30 memory locations 1 or 2 change-over contacts Width 71.5mm Installation design


    Original
    TSC44 TSC44 4000VA automatic change over switch circuit relay POTENTIAL FREE CONTACT tsc44.22 PDF

    automatic change over switch circuit relay

    Abstract: TSC28 230Vac changeover relay 230VAC RELAY
    Contextual Info: Digital time switches - DIN-Rail mounting Functions ON/OFF IMPULS, MANUAL Sealable Daily-, weekly and holiday program Width 38,5mm TSC28 1 or 2 change-over contacts Installation design Automatic summertime change over Unrestricted block-programming 30 memory locations


    Original
    TSC28 KA-TSC28: automatic change over switch circuit relay TSC28 230Vac changeover relay 230VAC RELAY PDF

    relais reed 108 r12

    Abstract: 108 R12 celduc reed 108 R12 celduc 200 R05 celduc 108 R12 celduc 100 R05 celduc 108 133R12720 Celduc Relais R0721
    Contextual Info: R/MER/R072.P0./B/28/08/2001 page 1 / 2 F/GB RELAIS REED A 2 CONTACTS INVERSEURS MERCURE / REED RELAY / 2 CHANGE OVER MERCURY CONTACTS R072 . P00 R0866 P . . Pour circuit imprimé/ For printed circuit board 2 contacts inverseurs mercure/ 2 change over mercury contacts


    Original
    R/MER/R072 /B/28/08/2001 R0866 R0720P00 R0721P00 R0866P06 R0866P15 relais reed 108 r12 108 R12 celduc reed 108 R12 celduc 200 R05 celduc 108 R12 celduc 100 R05 celduc 108 133R12720 Celduc Relais R0721 PDF

    108 R12 celduc

    Abstract: relais reed 108 r12 celduc 108 R12 hAUT 133 R24 761 reed 108 R12 133 r24 761 celduc 200 R24 celduc 108 relais reed celduc RELAIS REED
    Contextual Info: R/MER/R076.P./A/5/10/2000 page 1 / 2 F/GB RELAIS REED A 1 CONTACT INVERSEUR MERCURE REED RELAY / 1 CHANGE OVER MERCURY CONTACT R0861 P12 R076 . P00 Pour circuit imprimé/ For printed circuit board 1 contact inverseur mercure/ 1 change over mercury contact


    Original
    R/MER/R076 /A/5/10/2000 R0861 R0861P12 R0760P00 R0761P00 108 R12 celduc relais reed 108 r12 celduc 108 R12 hAUT 133 R24 761 reed 108 R12 133 r24 761 celduc 200 R24 celduc 108 relais reed celduc RELAIS REED PDF

    r025

    Abstract: celduc 200 R12 252 celduc 200 R24 R0250 celduc 200 R12 R0251 R0253 R24 marking celduc 150 R12 celduc 100 R12
    Contextual Info: R/SEC/R025.W00/A/3/10/2000 page 1 / 2 F/GB RELAIS REED A CONTACT SEC INVERSEUR REED RELAY / CHANGE OVER DRY CONTACT R025 . W00 Pour circuit imprimé/ For printed circuit board Un contact normalement ouvert/ One change over contact sous capot métal/ In metal cover


    Original
    R/SEC/R025 W00/A/3/10/2000 R0250W00 R0251W00 R0252W00 R0253W00 r025 celduc 200 R12 252 celduc 200 R24 R0250 celduc 200 R12 R0251 R0253 R24 marking celduc 150 R12 celduc 100 R12 PDF

    F72C5500

    Contextual Info: R/MER/F72C.500/A/12/10/2000 RELAIS REED A 2 CONTACTS INVERSEUR MERCURE / REED RELAY / 2 CHANGE OVER MERCURY CONTACTS page 1 / 2 F/GB F72C . 500 Pour circuit imprimé/ For printed circuit board 2 contacts inverseurs mercure/ 2 change over mercury contacts Sous capot métal/ In metal cover


    Original
    R/MER/F72C 500/A/12/10/2000 F72C2500 F72C5500 F72C7500 F72C75ancy 10-9physical F72C5500 PDF

    celduc 150 R12

    Abstract: R058 583d celduc 100 R05 relais reed celduc celduc 200 R12
    Contextual Info: R/SEC/R058-002/B/1/03/2004 RELAIS REED A CONTACT SEC INVERSEUR BISTABLE REED RELAY / BISTABLE CHANGE OVER DRY CONTACT page 1 / 2 F/GB R0583 W01 Pour circuit imprimé / For printed circuit board Un contact inverseur bistable / bistable change over contact sous capot métal/ In metal cover


    Original
    R/SEC/R058-002/B/1/03/2004 R0583 R0583W01 R0584W01 celduc 150 R12 R058 583d celduc 100 R05 relais reed celduc celduc 200 R12 PDF

    tele odq1

    Abstract: odq1 Tele Control tele RELAY fuse 8A 1000VA led flasher diagrams free a1151 D-82069
    Contextual Info: ODQ1 Timer - OCTO series Installation design Width 17.5 mm 4 functions, 6 time ranges 1 change-over contact Technical data: 1. Functions 6. Output circuit E R Wu Bp 1 potential free change-over contact Switching capacity distance < 5mm : 750VA (3A / 250V AC)


    Original
    750VA 1000VA 60/min 100VA D-82069 tele odq1 odq1 Tele Control tele RELAY fuse 8A led flasher diagrams free a1151 PDF

    Contextual Info: Datasheet MCO-5211 Master Sync Change-Over Cost-efficient performance and versatility. The MCO-5211 master sync change-over from Grass Valley, a Belden Brand, is designed for use in both serial digital and analog television environment, including AES3 digital audio signals. The use


    Original
    MCO-5211 MCO-5211 MSG-5300 GVB-1-0402A-EN-DS PDF

    Contextual Info: Datasheet HCO-1822 HD/SD/ASI Change-Over with Clean Switch and ALC Space-saving, modular platform for advanced signal processing. The HCO-1822 from Grass Valley, a Belden Brand, is a 2x1 HD/SD/ASI change-over which supports 16 channels of embedded audio and metadata.


    Original
    HCO-1822 HCO-1822 HCO-1822â RCP-200 GVB-1-0383B-EN-DS PDF

    Contextual Info: Datasheet DCO-1741-1781 2/4 AES Audio Change-over with Silent Switch Option Space-saving, modular platform for advanced signal processing. The DCO-1741/1781 from Grass Valley, a Belden Brand, is a 2/4 AES change-over. The switch is performed electronically by an internal router. In the event of a power failure, the signal is protected by the relays fitted


    Original
    DCO-1741-1781 DCO-1741/1781 ADC-1101, XVP-3901 RCP-200 GVB-1-0355A-EN-DS PDF

    Contextual Info: Datasheet HCO-3901 3G/HD/SD/ASI Change-Over with Clean Switch and ALC Space-saving, modular platform for advanced signal processing. The HCO-3901 from Grass Valley, a Belden Brand, is a 3x1 3G/HD/SD/ASI change-over which support 16 channels of embedded audio and metadata. The


    Original
    HCO-3901 HCO-3901 NSH15M HD-15 GVB-1-0384C-EN-DS PDF

    star delta connection circuit diagrams

    Abstract: relay vde 0435 VDE 0110 off delay timer vde 0435 timer vde 0110 AC12 R0100 95F2
    Contextual Info: Electronic timer CT-SDS.22 2CDC 251 083 F0t06 Star-delta change-over with 2 n/o contacts Data sheet Features ᕃ ᕅ ᕆ ᕄ ᕇ ᕈ ½ ½ ½ ½ ½ ½ ½ Rated control supply voltage 24-48 V DC, 24-240 V AC Single-function timer with star-delta change-over


    Original
    F0t06 F0005 D0201 star delta connection circuit diagrams relay vde 0435 VDE 0110 off delay timer vde 0435 timer vde 0110 AC12 R0100 95F2 PDF

    1MRK 514 001-BEN

    Abstract: 1mrk 002 080-AN IEC 60255-5 ABB Air Circuit breaker circuit diagram VOLTAGE SUPERVISION RELAY 1MRK 507 004-UEN 001-BEN 080AD 080-AN trip circuit supervision relay
    Contextual Info: Supervision relay RXEM 1 1MRK 508 024-BEN Page 1 Issued: January 2004 Revision: Data subject to change without notice Features • Two independent supervision circuits in one module • Undervoltage operation • Operation delayed 2.2 s or 1.1 s 24V • Two change-over contacts per circuit


    Original
    024-BEN 080-AH 080-AN 080-AS 004-UEN 003-BEN 001-BEN SE-721 1MRK 514 001-BEN 1mrk 002 080-AN IEC 60255-5 ABB Air Circuit breaker circuit diagram VOLTAGE SUPERVISION RELAY 1MRK 507 004-UEN 001-BEN 080AD 080-AN trip circuit supervision relay PDF

    relay vde 0435 VDE 0110 off delay timer

    Abstract: star delta connection circuit diagrams K 1718 AC12 R0100 power circuit diagram R2300
    Contextual Info: Electronic timer CT-SDS.23 2CDC 251 083 F0t06 Star-delta change-over with 2 n/o contacts Data sheet Features ᕃ ᕅ ᕆ ᕄ ᕇ ᕈ ½ ½ ½ ½ ½ ½ ½ Rated control supply voltage 380-440 V AC/DC Single-function timer with star-delta change-over One device includes 7 time ranges 0.05 s - 10 min


    Original
    F0t06 F0005 D0201 relay vde 0435 VDE 0110 off delay timer star delta connection circuit diagrams K 1718 AC12 R0100 power circuit diagram R2300 PDF

    G2JM5AL20

    Abstract: 1000VA
    Contextual Info: G2JM5AL20 Monitoring relays - GAMMA series 3-phase current monitoring Multifunction Fault latch Supply voltage selectable via power modules 2 change-over contacts 1 Width 22.5mm Industrial design Subject to alterations and errors Technical data 1. Functions


    Original
    G2JM5AL20 G2JM5AL20 1000VA PDF

    RBS-2601

    Abstract: RBS-2604 RBS-2605 RBS-2603 RBS-2602 RBS 620 DC-13 RBS-2613
    Contextual Info: Sicherheitsrelais RBS Safety Relay RBS MERKMALE FEATURES Zwangsgeführter Kontaktsatz mit 2 Kontakten, unterschiedliche Kontaktkonfigurationen, auch mit Wechsler erhältlich. Forced guided contact set with 2 contacts, different contact configurations, also available with change-over contact.


    Original
    PDF

    1000VA

    Contextual Info: OPLR3 Monitoring relays - OCTO series Voltage monitoring in 3-phase mains Undervoltage monitoring Connection of neutral wire necessary Tripping delay adjustable 2 change-over contacts Width 35mm Installation design Technical data 1. Functions 6. Output circuit


    Original
    750VA 1250VA 1000VA 60/on 400/230V PDF

    1000VA

    Contextual Info: G2TF01 Monitoring relays - GAMMA series Temperature monitoring of the motor winding Supply voltage selectable via power modules 1 change-over contact External reset key connectable Width 22.5mm Industrial design Technical data 1. Functions 6. Output circuit


    Original
    G2TF01 750VA 1250VA 1000VA PDF

    2.5V RELAY

    Abstract: 1000VA
    Contextual Info: G2TF02 Monitoring relays - GAMMA series Temperature monitoring of the motor winding Supply voltage selectable via power modules 2 change-over contacts External reset key connectable Width 22.5mm Industrial design Technical data 6. Output circuit 1. Functions


    Original
    G2TF02 2.5V RELAY 1000VA PDF

    1000VA

    Contextual Info: OPLE3 Monitoring relays - OCTO series Voltage monitoring in 3-phase mains Undervoltage monitoring Connection of neutral wire necessary Tripping delay adjustable 2 change-over contacts Width 35mm Installation design Technical data 1. Functions 6. Output circuit


    Original
    750VA 1250VA 1000VA 60/min 400/230V PDF

    "red led" 5mm

    Abstract: 44081 Thermistor 15k 20 degree c 1000VA G2TFKN02
    Contextual Info: G2TFKN02 Monitoring relays - GAMMA series Temperature monitoring of the motor winding Short circuit monitoring of thermistor line Zero-voltage latch Supply voltage selectable via power modules 2 change-over contacts External reset key connectable Width 22.5mm


    Original
    G2TFKN02 "red led" 5mm 44081 Thermistor 15k 20 degree c 1000VA G2TFKN02 PDF

    11-POL

    Abstract: 1000VA 230v 3 phase relay
    Contextual Info: K3PF400VSY02 Monitoring relays - KAPPA series Voltage monitoring in 3-phase mains Monitoring of phase sequence and phase failure Monitoring of asymmetry Optional connection of neutral wire Supply voltage = measuring voltage 2 change over contacts Plug-in housing


    Original
    K3PF400VSY02 100ms 400/230V 11-POL 1000VA 230v 3 phase relay PDF