Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    CANADIAN GENERAL ELECTRIC COMPANY Search Results

    CANADIAN GENERAL ELECTRIC COMPANY Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    CRG09A Toshiba Electronic Devices & Storage Corporation General-purpose diode, 400 V, 1 A , Rectifier Diode, S-FLAT Visit Toshiba Electronic Devices & Storage Corporation
    CMG03A Toshiba Electronic Devices & Storage Corporation General-purpose diode, 600 V, 2 A , Rectifier Diode, M-FLAT Visit Toshiba Electronic Devices & Storage Corporation
    CRG11B Toshiba Electronic Devices & Storage Corporation General-purpose diode, 400 V, 0.4 A , Rectifier Diode, S-FLAT Visit Toshiba Electronic Devices & Storage Corporation
    CRG10A Toshiba Electronic Devices & Storage Corporation General-purpose diode, 600 V, 0.7 A , Rectifier Diode, S-FLAT Visit Toshiba Electronic Devices & Storage Corporation
    CRG09B Toshiba Electronic Devices & Storage Corporation General-purpose diode, 400 V, 1 A , Rectifier Diode, S-FLAT Visit Toshiba Electronic Devices & Storage Corporation

    CANADIAN GENERAL ELECTRIC COMPANY Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    plc based automatic car parking system

    Abstract: denso map sensor Denso radar common rail denso 1 928 403 095 bosch denso ford visteon Bosch radar BOSCH 1 928 403 192 ic mitsubishi 4271 denso mass air flow
    Text: 2000 Annual Report 1 Business Overview Dynex is a research based technology company focused on the supply of products and services in the field of power semiconductors and microwave sensors. Dynex continues to do business in other areas related to the semiconductor and integrated circuit markets.


    Original
    LF5442-1 plc based automatic car parking system denso map sensor Denso radar common rail denso 1 928 403 095 bosch denso ford visteon Bosch radar BOSCH 1 928 403 192 ic mitsubishi 4271 denso mass air flow PDF

    thyristor t 558 f eupec

    Abstract: thyristor testing electrical power system circuits boomer 281 eupec thyristor testing method wind turbine 100kw induction furnace using igbt EUPEC T 558 F reliance thyristor airbus A380 IGBT inverter wind turbine
    Text: Driving The Future Table of Contents 2 Annual Report 2001 Business Overview 3 Fiscal Highlights 2001 4 Letter to Shareholders 5-6 Description of Operations 7 Products 8 Power Research and Development 9 Management Discussion and Analysis 10-12 Management’s Responsibility for Financial Reporting


    Original
    LF5522-1 thyristor t 558 f eupec thyristor testing electrical power system circuits boomer 281 eupec thyristor testing method wind turbine 100kw induction furnace using igbt EUPEC T 558 F reliance thyristor airbus A380 IGBT inverter wind turbine PDF

    DR-6

    Abstract: Canadian General Electric Company
    Text: LED Signals Technical Data LED Traffic Signal Modules DR4 / DR6 • Full Ball 1 Dimensions DR6 • Arrow 52 300 2.44" (11.8") Dimensions = mm (inches) 47 61.7 210 Dimensions (11.0") (2.43") (8.24") 1 194 2 Dimensions = mm (inches) Pe r fo r m a n c e S t a n d a rd s


    Original
    MIL-STD-883 DR-6 Canadian General Electric Company PDF

    CFC8

    Abstract: PS6-PFD2-01A CFC-4 CCC4
    Text: LED Signals Technical Data LED Traffic Signal Modules PR6 / PS6 • Pedestrian 1 Dimensions 304 11.89" PS7 • Pedestrian 1 Dimensions = mm (inches) 121 (4.75") 86 (3.37") 304 (11.89") Dimensions 480 (17.17") 82 (3.25") 40 (1.68") 2 Dimensions = mm (inches)


    Original
    MIL-STD-883 CFC8 PS6-PFD2-01A CFC-4 CCC4 PDF

    ascom

    Abstract: kearfott SUPERMAC Pratt Whitney alps labeling Raytheon MCT daikin Dolphin honeywell Ericsson Marconi carl zeiss
    Text: Systems in Silicon 3_bU\Yc9^S 8@<_WYS1^Q\ijUbCe``_bd 3_bU\Yc9^S !"& '8YTTU^SbUU[GQi3UbbYd_c31 ' # %&")"&&'"'cQ\Uc0S_bU\YcS_] gggS_bU\YcS_] 1 Company Overview • Privately held • Founded 1991


    Original
    PDF

    DQ65033QMB06NNS

    Abstract: tdk pc95 RM6 ferrite core PQ48033HTB50NKS PQ48033qga25nns pq48033qgb25 PQ48033QGB25NNS pq48018qga25nns TDK RM6 PQ60033EMM15NNS
    Text: File E194341 Project 99ME33731 Issued: May 12, 1999 Revised: October 28, 2005 REPORT on COMPONENT - POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT SynQor Corp. Boxborough , MA Copyright 1999 Underwriters Laboratories Inc.


    Original
    E194341 99ME33731 PQ60033SGL20NNS PQ60033SGL20NNS, PQ60XSYZA 34-XXXXXXX, PS2911-1, DQ65033QMB06NNS tdk pc95 RM6 ferrite core PQ48033HTB50NKS PQ48033qga25nns pq48033qgb25 PQ48033QGB25NNS pq48018qga25nns TDK RM6 PQ60033EMM15NNS PDF

    FETEX-150

    Abstract: biosensor Palm Vein Technology WX300 "CMOS GATE ARRAY" fuji graphene SHINKO pharma suite riken fujitsu optical module
    Text: Corporate Data History of Fujitsu ● Business 1935 ~ Developments ● Jun 20, 1935 ⿟Fuji Tsushinki Manufacturing Corporation, the company that later becomes Fujitsu Limited, is born as an offshoot of the communications division of Fuji Electric. The new company is


    Original
    PDF

    STR 6757 OF equivalent

    Abstract: Johnson motor 2 607 022 013 Barber-Colman CP AT-1163 ms-517
    Text: Electric/Electronic Products Catalog Make the most of your energy General Information TAC TAC is a Schneider Electric Company with a long tradition of global leadership in building controls technology. We offer the most extensive line of controls and components available to today's market, including: valve bodies, valve assemblies, actuation devices and sensors, as well as interfaces, and automated systems that link these products and other building systems


    Original
    F-27382-2 STR 6757 OF equivalent Johnson motor 2 607 022 013 Barber-Colman CP AT-1163 ms-517 PDF

    Untitled

    Abstract: No abstract text available
    Text: Scotchlok Insulation Displacement Electrical Pigtail Connector 557 Data Sheet Application Engineering Specification Use Scotchlok Pigtail 557 to electrically connect two wire ends and insulate the connection. ™ Wire Range 22-16 AWG solid or stranded, 0,5-1,0 mm2 solid or


    Original
    8-8126-5928-8-A PDF

    tettex

    Abstract: BIDDLE
    Text: Marshall Technology Center Putting tomorrow’s materials and cable designs to the test Since its inception in 1968, Marshall Technology Center MTC in Marshall, Texas, has been a World Class Testing and Analytical Center with the market focus of energy cable technology. With over three


    Original
    PDF

    saa 7321 datasheet

    Abstract: eaton T85 MS35058 Eaton switches 61120 7818k1 8370K150 MS35059 ms25125 8980K1 8370K
    Text: 59-01 Cover/Intro. 1/26/99 3:25 PM Page I TABLE OF CONTENTS Page Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I-VIII Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Over land, over sea, overcoming solar, wind power transmission challenges Q&A with General Cable • Cables used to transmit solar generation must be designed for sunlight resistance and a broad operating temperature range. • Wind cables are constructed with excellent flexibility, as well as


    Original
    PDF

    IEC 1010-1 General Safety Requirements

    Abstract: nema 23 stepping motor 3-DIGIT 7-SEGMENT LED DISPLAY nema 23 wiring datasheet emi line filter IEC 61000-4-3 IEC-1010-1 loss of neutral monitor block diagram of power meter Corcom
    Text: Bulletin No. PAXLHV-A Drawing No. LP0568 Released 10/03 Tel +1 717 767-6511 Fax +1 (717) 764-0839 www.redlion-controls.com MODEL PAXLHV - PAX LITE AC VOLTAGE MONITOR C UL R ! 3-DIGIT, 0.56" (14.2 mm) HIGH LED DISPLAY ! AUTO ZEROING CIRCUIT ! NEMA 4X/IP65 SEALED FRONT BEZEL


    Original
    LP0568 4X/IP65 IEC 1010-1 General Safety Requirements nema 23 stepping motor 3-DIGIT 7-SEGMENT LED DISPLAY nema 23 wiring datasheet emi line filter IEC 61000-4-3 IEC-1010-1 loss of neutral monitor block diagram of power meter Corcom PDF

    wiring diagram auto switch over panel

    Abstract: air core meter 51EB UL61010A-1 schaffner IT 101
    Text: Bulletin No. PAXLHV-C Drawing No. LP0568 Released 12/09 Tel +1 717 767-6511 Fax +1 (717) 764-0839 www.redlion.net MODEL PAXLHV - PAX LITE AC VOLTAGE MONITOR C UL R  3-DIGIT, 0.56" (14.2 mm) HIGH RED LED DISPLAY  AUTO ZEROING CIRCUIT  NEMA 4X/IP65 SEALED FRONT BEZEL


    Original
    LP0568 4X/IP65 Ahmedabad-382480 wiring diagram auto switch over panel air core meter 51EB UL61010A-1 schaffner IT 101 PDF

    E66903

    Abstract: No abstract text available
    Text: BUILDING WIRE COPPER BUILDING WIRE & CABLE FOR COMMERCIAL AND RESIDENTIAL APPLICATIONS O C T O B E R 2 012 Building Wire Servicing Commercial and Residential Applications This catalog contains in-depth information on our full line of building wire power cables


    Original
    INS-0132-R1012 E66903 PDF

    BNC 1553

    Abstract: Trompeter twin bnc twin bnc RG-108A twin bnc tyco TWC-124-2 MIL-P-19 Tool-69710-1 TWC-124 Trompeter Electronics
    Text: RF Coax Connectors Twin BNC Connectors Product Facts • Crimp connectors require only one-stroke crimping of both conductors, plus braid and cable support ■ Lower installed cost with one-stroke crimp ■ Reduced noise levels because of Tyco Electronics


    Original
    E81956 Connect35 BNC 1553 Trompeter twin bnc twin bnc RG-108A twin bnc tyco TWC-124-2 MIL-P-19 Tool-69710-1 TWC-124 Trompeter Electronics PDF

    Untitled

    Abstract: No abstract text available
    Text: GE Energy Data Sheet CP2500DC54-PE Compact Power Line DC/DC Converter Input: -40 to -72Vdc; Outputs: ±54 Vdc @ 2500W; 5 Vdc @ 4W Features • Compact 1-RU form factor providing 22 W/in3  Input Current < 75A at 40 Vdc input  Programmable output voltage from 44V to 58 Vdc,


    Original
    CP2500DC54-PE -72Vdc; RS4851 IEEE802 48Vdc CP2500DC54-PEZ CC109170528 PDF

    Untitled

    Abstract: No abstract text available
    Text: File E135803 Vol. 2 Sec. 2 and Report Page 1 Issued: Revised: 2000-01-11 2006-02-14 DESCRIPTION PRODUCT COVERED: Component - Switching Power Supplies for Use in Information Technology Equipment, Models GPM40A, GPM40B, GPM40D, GPC40A, GPC40B, GPC40D, GPC40-X and


    Original
    E135803 GPM40A, GPM40B, GPM40D, GPC40A, GPC40B, GPC40D, GPC40-X GPM40-X PDF

    CLP0212FP

    Abstract: CLP0212FPXX3Z01A CLP0212FPEX5Z01A CLP0212 normal diode 3 phase rectifier diode load 200w iphone circuit diagram iphone connect iphone AC connector 230v 12Vdc 5a 200W OUTPUT
    Text: PRODUCT OVERVIEW CLP0212 Open Frame Power Supply High-efficiency, Compact, Cost-effective • 200W,12Vdc stand-alone power system • 80 PLUS Gold efficiency • Maximum power in small space – 18W/in³ • No load power consumption less than 0.5 watts.


    Original
    CLP0212 12Vdc CLP0212FP CLP0212FPXX3Z01A CLP0212FPEX5Z01A normal diode 3 phase rectifier diode load 200w iphone circuit diagram iphone connect iphone AC connector 230v 12Vdc 5a 200W OUTPUT PDF

    CHN 920 diode

    Abstract: CHN 920
    Text: PRODUCT OVERVIEW CLP0212 Open Frame Power Supply High-e ciency, Compact, Cost-e ective • 200W,12Vdc stand-alone power system • 80 PLUS Gold e ciency • Maximum power in small space – 18W/in³ • No load power consumption less than 0.5 watts. • Powering communications, computing,


    Original
    CLP0212 12Vdc CHN 920 diode CHN 920 PDF

    2-DIGIT 7-SEGMENT LED DISPLAY datasheet

    Abstract: FERRITE core TRANSFORMER 2-DIGIT 7-SEGMENT LED DISPLAY high power FERRITE TRANSFORMER IEC 1010-1 General Safety Requirements ac amp meter clamp current transformer "AC Motor" rating value of transformer 2 digit ac amp meter ct
    Text: Bulletin No. PAXLIT-B Drawing No. LP0569 Released 10/03 Tel +1 717 767-6511 Fax +1 (717) 764-0839 www.redlion-controls.com MODEL PAXLIT - PAX LITE 5 AMP AC CURRENT METER C UL R US LISTED IND. CONT. EQ. ! 5 AMP AC CURRENT INPUT* ! 3 1/2-DIGIT, 0.56" (14.2 mm) HIGH LED DISPLAY


    Original
    LP0569 4X/IP65 2-DIGIT 7-SEGMENT LED DISPLAY datasheet FERRITE core TRANSFORMER 2-DIGIT 7-SEGMENT LED DISPLAY high power FERRITE TRANSFORMER IEC 1010-1 General Safety Requirements ac amp meter clamp current transformer "AC Motor" rating value of transformer 2 digit ac amp meter ct PDF

    dc welding machine circuit diagram rohs ct 416

    Abstract: KEMA KEUR thermostat submersible motor winding formula
    Text: Cord & Cordset Products FO R INDU STRIAL, COMME RCI AL AN D SP ECI ALT Y AP P L I CAT I O N S Cord & Cordset This catalog contains in-depth information on the most comprehensive line of cord and cordset products. General Cable’s flexible cord products are available


    Original
    CAR-0084-R0115 dc welding machine circuit diagram rohs ct 416 KEMA KEUR thermostat submersible motor winding formula PDF

    Untitled

    Abstract: No abstract text available
    Text: GE Data Sheet CP2725AC48TEZ-FB Compact Power Line High Efficiency Rectifier Input: 100-120/220-240 Vac; Output: 2725W1 @ 52Vdc; 5 Vdc @ 4W Features Applications • Wide band power amplifiers        Efficiency 95%      


    Original
    CP2725AC48TEZ-FB 2725W1 52Vdc; 240Vac 120Vac 42Vdc) 53Vdc RS485 CP2725AC48TEZ-FB 48Vdc PDF

    RDHX223K302HKT

    Abstract: 202S48W334KT RDHX333K302HKT
    Text: GE Data Sheet KHHD004A2S8R0 Hammerhead Series; DC-DC Converter Power Modules 18-60Vdc Input; 8Vdc, 4.2A, 34W Output Features RoHS Compliant Applications • Compliant to RoHS EU Directive 2002/95/EC -Z versions • Input Voltage Range, 18Vdc to 60Vdc


    Original
    KHHD004A2S8R0 18-60Vdc 48Vdc) 1/16th 18Vdc 60Vdc 2002/95/EC KHHD004A2S8R0841Z 4V/48V 18-60Vdc) RDHX223K302HKT 202S48W334KT RDHX333K302HKT PDF