Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    AUTOMATIC CURTAIN Search Results

    AUTOMATIC CURTAIN Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    Automatic-Liquid-Dispenser Renesas Electronics Corporation Automatic Liquid Dispenser Reference Design Visit Renesas Electronics Corporation
    Automatic-Liquid-Dispenser-Cap Renesas Electronics Corporation Automatic Liquid Dispenser with Proximity Capacitive Sensing Reference Design Visit Renesas Electronics Corporation
    Safety-Light-Curtain Renesas Electronics Corporation Safety Light Curtain Reference Design Visit Renesas Electronics Corporation
    ICL7673CBAZA-T Renesas Electronics Corporation Automatic Battery Back-Up Switch Visit Renesas Electronics Corporation
    ICL7673CPAZ Renesas Electronics Corporation Automatic Battery Back-Up Switch Visit Renesas Electronics Corporation

    AUTOMATIC CURTAIN Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    PNOZ M1P serial cable

    Abstract: PNOZmulti password pilz pnozmulti serial cable pilz PNOZ serial cable PILZ pnoz m1p error PILZ PNOZ M1P PNOZ MC1P PILZ PNOZ m2p pilz error list pnoz m1p
    Text: PNOZmulti Configurator Version 4 – Highlights Integration of press functions and a new special press base module Press functions for controlling and monitoring mechanical presses: Operating modes such as setup, single-stroke and automatic Safety light curtains in single-break and double-break mode


    Original
    PDF

    IEC-61496-2

    Abstract: No abstract text available
    Text: Safety Light Curtains Hand resolution series SB4-35/.-D15 • Safety Category 4 in conformity with EN 61496-1 and /-2 • Hand resolution • Test, start and override functions • On board DIP switch selectable functions: partial / total muting and manual / automatic restart


    Original
    SB4-35/. SB4-35 ProtecteD15 SB4-35/481-D15 SB4-35/628-D15 SB4-35/775-D15 SB4-35/922-D15 SB4-35/1069-D15 SB4-35/1216-D15 SB4-35/1363-D15 IEC-61496-2 PDF

    automatic curtain system

    Abstract: NL13D
    Text: Light curtain safety Module NL13D • • • • • • • • Safety Category 4 according to EN 954-1 3 NO safety outputs, with force guided relay contacts 24 VAC / VDC power supply Dual channel input Automatic or manual reset Self monitoring Failure diagnosis by LEDs


    Original
    NL13D NL13D automatic curtain system PDF

    AT3500

    Abstract: No abstract text available
    Text: AT3600 Automatic Transformer Tester User Manual  Voltech 2000-2008 Voltech Instruments VPN 98 - 024 V17 VOLTECH AT SERIES USER MANUAL Voltech Instruments are committed to a policy of continuous product development. Hence, product specification and the information given in this manual are subject to change without


    Original
    AT3600 75msec 150mm. AT3600 AT3500 PDF

    Untitled

    Abstract: No abstract text available
    Text: Conductive Level Controller 61F-GP-N2 Cat. No. N43I-E-01 Automatic Water Supply and Drainage Control • Ideal for level control of any conductive liquid. • Compact plug-in controller for single- or two-point control of conductive liquid level. • 24/110/120/220/230/240 VAC operation possible.


    Original
    61F-GP-N2 N43I-E-01 61F-GP-N2 PDF

    Infrared sensor TSOP 1738

    Abstract: automatic door infrared sensor proximity sensor faucet tsop sensor infrared sensor TSOP 38 TSOP4P38 automatic faucet TSAL6100 application tsop4038 TSAL6100
    Text: V i s h ay I n t e r t e c h n o l o g y, I n c . With D igital or A nalog O utput o p t o e l e c t r o n i cs mid-range infrared sensors p r o d uc t o v e r v i e w w w w. v i s h a y. c o m Mid-Range Infrared Sensors With Digital or Analog Output Vishay’s mid-range sensors enable a wide variety of safety mechanisms and automatic fixtures in


    Original
    VMN-PL0438-xxxx Infrared sensor TSOP 1738 automatic door infrared sensor proximity sensor faucet tsop sensor infrared sensor TSOP 38 TSOP4P38 automatic faucet TSAL6100 application tsop4038 TSAL6100 PDF

    XPS ar

    Abstract: AR351144P iso 14119 diagnost XPSAR371144 XPSar311144p xps-ar311144 XPSAR311144 en iso 13850 DC-13 emergency leds
    Text: Safety automation system solutions Operating principle, characteristics Preventa safety modules type XPS AR For Emergency stop, switch or safety light curtain monitoring Operating principle Safety modules XPS AR meet the requirements of category 4 of the standard


    Original
    954-1/EN/ISO 1088/ISO category34 S33-S34 Y31/Y32 Y31/Y35 Y31/Y64 Y31/Y74 XPS ar AR351144P iso 14119 diagnost XPSAR371144 XPSar311144p xps-ar311144 XPSAR311144 en iso 13850 DC-13 emergency leds PDF

    idec 7-segment display module

    Abstract: automatic curtain system x37mm
    Text: IDEC-DATASENSOR Safety Light Curtains Safety Light Curtains Type 2 SG2 Series Basic & Extended Models Hand Protection Type 4 SG4 Series Presence Protection Finger Protection • Integrated light curtain for Hand Protection or Presence Control • Operating distance up to 19m


    Original
    1800mm 800-262-IDEC SG9Y-DS100-0 idec 7-segment display module automatic curtain system x37mm PDF

    Schmersal scr 1r

    Abstract: SCR 1R wiring diagram contactor with push button Schmersal Y2 TRANSISTOR emergency light circuit SCR emergency light circuit using SCR DIN EN 954-1 Schmersal scM 3RQ start push button
    Text: 10. 10.8 10.8.8 Safety monitoring modules Safety monitoring modules for special applications Monitoring of safety light grids/curtains and safety laser scanners using SCR 1R Features Dimensions Part number Approvals SK4 • Control Category 4 to EN 954-1 • Feedback circuit to monitor


    Original
    PDF

    IEC 947-5-1 VDE0660

    Abstract: XPSAR371144 XPSAR311144 XPSar311144p XPS-AR371144 xps-ar311144 XPSAR371144P S11-S52 A115C DC-13
    Text: Safety automation system solutions Operating principle, characteristics Preventa safety relay modules type XPSAR For Emergency stop, switch or light curtain monitoring Operating principle Safety modules XPSAR meet the requirements of category 4 of the standard


    Original
    954-1/EN/ISO13849-1 EN/ISO13850 EN/IEC60204-1. EN1088/ISO14119. XPSAR311144 XPSAR351144 XPSAR371144 XPSAR311144P XPSAR351144P XPSAR371144P IEC 947-5-1 VDE0660 XPSAR371144 XPSAR311144 XPSar311144p XPS-AR371144 xps-ar311144 XPSAR371144P S11-S52 A115C DC-13 PDF

    SNO4062K

    Abstract: SNO4003K SNV4063KL SNZ4052K SNA4043K WIELAND SNA 4063K SNV4076SL SNV4063KL-A SNA4043K-C SNA4064K
    Text: safety Safety Products Safety for all applications 0152.5 E 03/07 Safety switching devices from Wieland Electric Wieland Electric provides safety switching devices for all daily industrial use applications. Requiring only little space they combine excellent performance features


    Original
    IP20/IP65. SNO4062K SNO4003K SNV4063KL SNZ4052K SNA4043K WIELAND SNA 4063K SNV4076SL SNV4063KL-A SNA4043K-C SNA4064K PDF

    F39-MDG

    Abstract: Safety bus EN954-1 GS-ET-15 NL-2132 EN 50041 IEC 60947-5-1 limit switch
    Text: Safety Total solutions for industrial safety Safety light curtains Emergency stop buttons Safety relay units General-purpose limit switches Safety network systems Services for machine safety Safety switches Advanced Industrial Automation Safety sensors Safety switches


    Original
    PDF

    relay 24v omron

    Abstract: hot air gun fan controller circuit carbon brush motor F3SN 485 omron IEC61496-1 key interlock solenoid magnetic contactors phase failure relay relay omron diagram
    Text: Safety Relay Unit Sensor Connector Type G9SA-300-SC Less Wiring Required with Safety Light Curtain • Sensor connector allows direct connection to OMRON F3SN-A/ F3SN-B/F3SH-A Safety Light Curtains with PNP outputs. ■ Reduces wiring and prevents incorrect connection.


    Original
    G9SA-300-SC relay 24v omron hot air gun fan controller circuit carbon brush motor F3SN 485 omron IEC61496-1 key interlock solenoid magnetic contactors phase failure relay relay omron diagram PDF

    Untitled

    Abstract: No abstract text available
    Text: ES-FA-6G 1-Channel Emergency Stop Safety Module 24V ac/dc operation E-Stop Safety Module Features • Monitors one single-channel normally closed Emergency Stop switch circuit for a contact failure or wiring fault • Three output switching channels for connection to control-reliable power


    Original
    UL991, EN418, EN954-1 EN418 PDF

    IEC61496

    Abstract: EN61496-1 led panel 1200mm x 600mm
    Text: Photo Electric Safety Systems Safety Approach Risk Assessment SELECTING PRODUCT When selecting the proper safety system for a potentially dangerous automated machine, the first area that must be examined is the machine’s control reliability and suitability


    Original
    PDF

    2455R

    Abstract: HIH-4030 HIH-6130 2455RVB landing gear proximity switches crane Proximity switch 2455Rc Potentiometric Pressure Transducer thin film rtds honeywell 3153
    Text: Thermal Sensors SENSING AND CONTROL Product Range Guide 1 For innovation that’s well apart, there’s only Honeywell Sensing and Control. With more than 50,000 products ranging from snap-action, limit, toggle, and pressure switches to position, speed, pressure, and airflow sensors, Honeywell Sensing and Control


    Original
    009015-7-EN 2455R HIH-4030 HIH-6130 2455RVB landing gear proximity switches crane Proximity switch 2455Rc Potentiometric Pressure Transducer thin film rtds honeywell 3153 PDF

    QXA2602

    Abstract: CM1Y9777 TRIAC ACS 12 QXA2604 cm1y9775 X2M ST
    Text: s Room thermostats with KNX communications 3 191 RDG100KN RDG160KN – For fan coil unit applications – For universal applications – For use with compressor in DX type equipment • • • • • • • • • • • • • • • • KNX bus communication S-mode and LTE mode


    Original
    RDG100KN RDG160KN RDG100KN, RDG160KN CE1N3191en QXA2602 CM1Y9777 TRIAC ACS 12 QXA2604 cm1y9775 X2M ST PDF

    D-73277

    Abstract: D-73277 leuze
    Text: MSI-SR4B EN 2013/10 - 50124419 We reserve the right to make technical changes Safety relays Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net 1 2 About this document. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4


    Original
    PDF

    telemecanique selector

    Abstract: telemecanique limit switch telemecanique push relay safety telemecanique XPS-MC32 XPS-MC16 off delay timer telemecanique TSXPCX1031 telemecanique hand switch telemecanique cam switch
    Text: XPS-MCWIN Configuration Software for XPS-MC16 and XPS-MC32, for MS-Windows All rights reserved, in particular the rights of reproduction and translation. Copying or reproduction in any form requires prior written permission from copyright owner. Changes due to technical improvement may be made.


    Original
    XPS-MC16 XPS-MC32, 26-GB 2GB/157/01 telemecanique selector telemecanique limit switch telemecanique push relay safety telemecanique XPS-MC32 off delay timer telemecanique TSXPCX1031 telemecanique hand switch telemecanique cam switch PDF

    Untitled

    Abstract: No abstract text available
    Text: 13.02.2013 22:52:39h Datasheet - PROTECT-PE-02-SK Input expander / PROTECT-PE • Input expander • Possibility to connect up to 4 sensors with non-isolated signals, e.g. the CSS products from Schmersal as well as AOPD’s only PROTECT-PE-02 • Input for up to 4 sensors per interface e.g.: magnetic safety switches type


    Original
    PROTECT-PE-02-SK PROTECT-PE-02) 4030661ng D-42279 PDF

    Schmersal AZM 160

    Abstract: Schmersal AZM 160 22 THERMAL Fuse m20 tf 115 c IEC 60947-5-1 limit switch EN 1088 schmersal interlock solenoid wiring diagram
    Text: Safety in system: Protection for man and machine Main catalogue | Safety technology | Version 8.1 K.A. Schmersal GmbH & Co. KG Safety control systems Möddinghofe 30 D-42279 Wuppertal Phone: +49- 0 2 02-64 74-0 Fax: +49-(0) 2 02-64 74-100 E-Mail: info@schmersal.com


    Original
    D-42279 Schmersal AZM 160 Schmersal AZM 160 22 THERMAL Fuse m20 tf 115 c IEC 60947-5-1 limit switch EN 1088 schmersal interlock solenoid wiring diagram PDF

    440R-N23132

    Abstract: 440rn23132 440R-N23130 MSR127TP MSR127RTP SR127TP 440R-N23I35 MSRI27RP power supply 24v WIRING DIAGRAM 440R-N23I33
    Text: specifications Safety Monitoring Relay Standards C_ Q_ C“ €^ c V V uy s 6IA954 i I MinotaurMSM27RPAP IEC/EN60204-I, ISOTRI2IOO, ISO 13849-1 EN 954-1 Safety Category Cat. 4 per EN 954-1 Approvals C E marked for all applicable directives, cULus and BG


    OCR Scan
    IEC/EN60204-I, 50/60Hz A/250V A/24V 10mA/10V 100ms 24-I2A 54lbin) SRI27RP SRI27TP 440R-N23132 440rn23132 440R-N23130 MSR127TP MSR127RTP SR127TP 440R-N23I35 MSRI27RP power supply 24v WIRING DIAGRAM 440R-N23I33 PDF

    440R-N23118

    Abstract: 440R-N23119 MSR126T 440R-N23114 sr1-26 440RN23114
    Text: specifications Safety Monitoring Relay Standards IE C 6 0 2 0 4 -I, IS O T R 12100 Safety Category Cat. 4 per E N 9 5 4 -I Approvals C E marked for all applicable directives, BG, and cU L u s except 4 2 V A C units Pow er Supply 24V A C / D C , 42/1 15/230V A C


    OCR Scan
    15/230V 50/60Hz A/250V A/24V 300ms 100ms MinotaurMSR126440R-N23I16 440R-N23115 440R-N23114 440R-N23113 440R-N23118 440R-N23119 MSR126T sr1-26 440RN23114 PDF

    TP20

    Abstract: No abstract text available
    Text: SIEMENS SFH420 GaAs Infrared Emitter SMT-TOP-LED Package Dimensions in Inches mm .083(2.1) .967 (1.7) (0-0.1) .094 124) „ 035(0.9) .021(0.7) 'h- .142 (3« ) .126(3 2 ) ik i _J .0*3 (1.1) .020(0.6) .024(0.6) .016 (0.4) • Fast Response Time • Matches with SFH320/SFH320F


    OCR Scan
    SFH420 SFH320/SFH320F SFH420 TP20 PDF