Text: measuring Vane Flow Meter, Monitor, Counter, Batching System • monitoring • in modular design • for liquids analysing S 4 DF OO Measuring ranges: 0.08-0.50 . 40-160 l/min water OO Measuring accuracy: ± 2.5% f.s. OO pmax: 100 bar; tmax: 80 °C
|
Original
|
HUNGARYR06
DN152)
DN252)
DN402)
|
PDF
|
258-041
Abstract: RS 258-041 OEM24L 2N3706 AD636JH AD736JN digital power factor meter circuit diagram vr2, preset VR1 100K preset diode LMP
Text: Issued November 1993 016-207 Data Pack F Data Sheet Digital panel meter modules RS stock numbers 258-041, 313-479 backlit version These complete digital panel meters will measure and display up to ±199.9mV directly with an accuracy of ±1.0%. The small size and ultra-low power consumption, with their liquid crystal display make these
|
Original
|
|
PDF
|
258-041
Abstract: digital power factor meter circuit diagram CA 3140 OP AMP RS 258-041 AD736JN OEM24L 2N3706 AD636JH Analogue DC Ammeter circuit ac digital panel meter
Text: Issued March 1997 232-4263 Data Pack F Data Sheet Digital panel meter modules RS stock numbers 258-041, 313-479 backlit version These complete digital panel meters will measure and display up to ±199.9mV directly with an accuracy of ±1.0%. The small size and ultra-low power consumption, with their liquid crystal display make these
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Flow DS 400 Flow measurement for compressed air and gases New chart recorder DS 400 3.5“ graphic display with touch screen shows the progression of the measured values in graphic form VHQVRULQSXWVIRUÀRZVHQVRUVGHZSRLQW sensors USB interface for reading out the data
|
Original
|
|
PDF
|
077-08AA-LSSU-C6
Abstract: AC digital voltmeter diagram Analogue Meter diagram AC digital voltmeter and ammeter 077-16FU-LS
Text: 070 Series ANSI Switchboard Meters Approvals UL Approved File No: E87815 This high quality range of Switchboard instruments complies with the American specification ANSI-C39.1 1981 accuracy class 1. Available in two case sizes, their rugged design characteristics
|
Original
|
E87815
ANSI-C39
LR99712-1
077-DW9
77-14A,
077-14L,
077-14D,
077-14G,
077-14H
077-08AA-LSSU-C6
AC digital voltmeter diagram
Analogue Meter diagram
AC digital voltmeter and ammeter
077-16FU-LS
|
PDF
|
PowerLogic PM710
Abstract: A9MEM3255 PM800 PM820 schneider pm710 Benchmark RS232 RTU METSEPM1200
Text: Basic energy metering Power Meter Series PM9 Functions and characteristics cont. Electrical characteristics Type of measurement Measurement accuracy Input-voltage characteristics Input-current characteristics Control Power Pulse output (PM9P) Current and voltage
|
Original
|
61557-a
EN50160
PE86002
PLSED309005EN
PowerLogic PM710
A9MEM3255
PM800
PM820
schneider pm710
Benchmark RS232 RTU
METSEPM1200
|
PDF
|
dip switch function
Abstract: No abstract text available
Text: DPM 490 4½ Digit LED Panel Meter This high performance meter uses 10mm 0.39“ LED displays behind a red window. The meter is housed in a robust DIN case and uses a 0.1" pitch shrouded pin connector at the rear. A screw terminal block adaptor board is available. With the simple addition of scaling resistors
|
Original
|
200mV
4-20mA
October/1998
dip switch function
|
PDF
|
AZ511
Abstract: TC4800 TR4800 AZ51 230VAC RELAY Tempatron TR4801 TT4800
Text: ANALOGUE PROCESS CONTROLLERS TR4800 TACHOMETER RELAY Part Numbering Options : TR4801 - A - B A Range 5 - 100 rpm 50 - 1000 rpm 500 - 10000 rpm B Power supply 110/230Vac 24Vac/dc 01 02 03 110/230VAC CONNECTION DIAGRAM BROWN 15V + BLACK BLUE 0V (-) 6 + 7 5
|
Original
|
TR4800
TR4801
110/230Vac
24Vac/dc
30V/24V
15Vdc
TC4800
TT4800
AZ511
TC4800
AZ51
230VAC RELAY
Tempatron
|
PDF
|
KSZ8041 USER
Abstract: plc transceiver LCD Module 2x20 free computer hardware and networking notes 433 mhz rf module fat32 library ECOG1X1A5 "USB" peripheral micrel ethernet phy interoperability
Text: USB / Ethernet / Cy-Net3 Gateway The Cyan USB / Ethernet / Cy-Net3 Gateway is a compact unit offering access to a Cy-Net3 network through an Ethernet or USB connection. The Cy-Net3 protocol is handled by a Cyan eCOG1X microcontroller and using the Micrel MICRF6xx Radiowire RF transceiver, operating
|
Original
|
915MHz
eCOG1X14Z5
2002/95/EC,
KSZ8041 USER
plc transceiver
LCD Module 2x20
free computer hardware and networking notes
433 mhz rf module
fat32 library
ECOG1X1A5
"USB" peripheral
micrel ethernet phy interoperability
|
PDF
|
Untitled
Abstract: No abstract text available
Text: ANALOGUE INSTRUMENTS nalogue Analogue instruments ANALOGUE INSTRUMENTS ANALOGUE INSTRUMENTS Analogue instruments CONTENTS GENERAL FEATURES . AI-04
|
Original
|
AI-04
AI-05
AI-60
|
PDF
|
Untitled
Abstract: No abstract text available
Text: DESCRIPTION CPM-10 CPM-10 Multifunction meter product single phase, three phases high accuracy measurement of parameters such as voltage, current, active power, reactive power, apparent power, power factor, frequency, effective energy, with display and remote communication
|
Original
|
CPM-10
CPM-10
RS485
120mm
DC100
0V/60mA
RS485
A5-01-CPM-10-2013-12-13
A5-01-3/3
|
PDF
|
DPM 160
Abstract: DPM 2000 ICL 7129 Application Notes TA 7136 p DPM 343 DPM 50 zener DIODE 8069 DPM 702s 7129 digital multimeter diagram DPM951
Text: 4 ICl 7660 4 3 5 1M 13 7 AD5 95 11 8 12 3 9 1 14 0V Panel Instrument Application Notes Issue 2 V +10 10µ 10µ 10K 1M 10µ DPM COM REF REF LO 10K 10µ 10µ 10K 20K -5V VDD V + VSS (V-) IN H IN L I O +5V ICL 8069 ICL 8069 2k2 +5V Index INSTALLATION & OPERATION - Section A
|
Original
|
|
PDF
|
JJG667-97
Abstract: Flow meter
Text: LL-F Roots Flow Meter made of Stainless Steel Model LL-F Roots flow meter made of stainless steel is a volumetric measuring instruments. Its components used for measurement should be made of stainless steel material with better corrosion resistance ability. This flow meter
|
Original
|
LPJ-12D
LPJ-12D/FI
LPJ-12D,
420mA
JJG667-97
Flow meter
|
PDF
|
Analogue Meter diagram
Abstract: No abstract text available
Text: Issued March 1997 232-2475 Data Pack F Data Sheet 31/2 digit LCD digital panel meter RS stock number 258-170 The RS 3 1/2 digit LCD digital panel meter combines the low power requirements of a liquid crystal display and LSI semiconductor technology to provide a high performance digital panel meter within a DIN/NEMA standard case. Connections to the meter are made via a 24
|
Original
|
|
PDF
|
|
DPM 56
Abstract: No abstract text available
Text: Bandgap Reference ANALOGUE INPUTS IN HI and IN LO are true differential inputs. That is to say that they respond to the voltage across them and not their voltage with respect to the power supply. There is a limit to this however, known as the Common Mode range. Any input must be no higher than V+ -0.5V and no lower than V- +1.0V. Note that V- is derived
|
Original
|
200mA
DPM 56
|
PDF
|
,national semiconductor Linear brief lb-3
Abstract: No abstract text available
Text: Energie-Messtechnik Energie-Management Netzqualitäts-Lösungen Software & Zubehör Power Quality Monitoring Power Management Power Quality Solutions Software & Accessories You can find us everywhere. There must be a reason. Main catalogue 2010 ▼ “Quality is never an accident;
|
Original
|
D-35633
,national semiconductor Linear brief lb-3
|
PDF
|
transistor a708
Abstract: No abstract text available
Text: Electronic Flow Meter FM1 Description Micro controller operated Flow Meter to monitor and display flow rates and temperature. Once correctly adjusted it can also be used for mass flow measurements. Factory pre-set for air and water. rail-mounted version 1
|
Original
|
|
PDF
|
82c55 application note
Abstract: PPI 82C55 82C55 PCI230 PCI223
Text: ADIO32 LabVIEW Driver Software AMPLICON ADIO32 LabVIEW DRIVER SOFTWARE GUIDE TO AMPLICON ADIO32 LABVIEW DRIVER SOFTWARE This Instruction Manual is supplied with Amplicon ADIO32 LabVIEW Driver Software to provide the user with sufficient information to utilise the purchased product in a proper and efficient manner. The information contained has been
|
Original
|
ADIO32
ADIO32
82C55
82c55 application note
PPI 82C55
PCI230
PCI223
|
PDF
|
DPM 10
Abstract: No abstract text available
Text: B16 B1 ANALOGUE INPUTS Low Power IN HI and IN LO are differential inputs. They respond only to the voltage between them and not their voltage with respect to the power supply. There is a limit to this however, known as the Common Mode Range CMR . Any input must be no higher than V+ - 0.5V and no lower than V- +1.0V (or no lower than 1.0V above the
|
Original
|
200mA
DPM 10
|
PDF
|
product catalogue
Abstract: eltime.co Schrack RA 450 024 FE96MCA BS7626 FE72MIA
Text: >> moving iron >> rectified moving coil >> frequency meters >> phase sequence indicators >> null voltmeters >> wattmeters Product Catalogue >> varmeteers >> power factor meters Global Suppliers of Measurement and Protection Equipment for Industry >> electromechanical hourmeters
|
Original
|
|
PDF
|
PT100 connected principle
Abstract: No abstract text available
Text: last update December 1, 2010 reference dcptn page 1/2 In standard UTI applications, the Pt 100 excitation is a square wave voltage between E and F AC signal , via the series connection of Rbias and Rref (see UTI Data sheet). This works fine as long as the cables are short (under 0,5 meter). When
|
Original
|
APPUTI08
PT100 connected principle
|
PDF
|
4 DIGIT LCD DISPLAY 11 PIN voltmeter
Abstract: 3 digit voltmeter circuit diagram 4070BP high voltage voltmeter lcd Voltmeter "digital panel meters" 13 pin bp26 BC237
Text: V 600 3½ Digit LCD Voltmeter Module PRODUCT DESCRIPTION The V 600 features a 200mV d.c. measurement range with auto-zero and auto-polarity. Decimal points are user selectable. The display features a low battery warning annunciator, which can be driven by external circuitry. The
|
Original
|
200mV
November/2001
4 DIGIT LCD DISPLAY 11 PIN voltmeter
3 digit voltmeter circuit diagram
4070BP
high voltage voltmeter
lcd Voltmeter
"digital panel meters" 13 pin
bp26
BC237
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Data Sheet High Voltage Test Set PGK 150 / 5 HB The two-part test sets PGK HB generate variable AC test voltages of mains frequency or DC voltages of positive or negative polarity. The operating unit in 19“ design has a voltage and current display, safety control elements according to
|
Original
|
6832-Sulz/Austria
|
PDF
|
Carlo Gavazzi Group pt-100
Abstract: PT-100 carlo gavazzi EDM35 PT 100 sensor installation EDM 35 PT 100 sensor dupline channel generator fpd 1901 Carlo Gavazzi CHANNEL GENERATOR Carlo Carlo Gavazzi Group edm35 Pt 1000 sensor
Text: Du line AnaLink EDM35 Plug-in Card Type G 2139 1139 Fieldbus Installationbus • Enables displaying of AnaLink signals on EDM35 panel meters • Operates with standard Dupline® channel generator • Coding by two rotary switches • Easy to use • Built-in prog-lock for all settings
|
Original
|
EDM35
EDM35
Carlo Gavazzi Group pt-100
PT-100 carlo gavazzi
PT 100 sensor installation EDM 35
PT 100 sensor
dupline channel generator fpd 1901
Carlo Gavazzi CHANNEL GENERATOR
Carlo
Carlo Gavazzi Group edm35
Pt 1000 sensor
|