Untitled
Abstract: No abstract text available
Text: Omni 2 Door Warning Alarm Annunciator Model C1190A Alarm Annunciator DATASHEET Features • Connects to multiple sensing instruments. • One/Two Channel Device. • Bright solid state LED Alarm Display. • Audible Alert internal and external . • High reliability, fully dual redundant alarm circuits.
|
Original
|
PDF
|
C1190A
IEC61508
85-264Vac
DSC1190AR07
|
UC625
Abstract: RTK Cables
Text: Technical Data October 2014 EPS RTK UC625 3 MTL Process Alarm Equipment RTK UC625 Programmable Alarm Annunciator • Alarm Sequence selectable to ISA S18.1-1979 • Available in a range of sizes from 12 to 40 ways • Expansion units available to create larger systems
|
Original
|
PDF
|
UC625
UC625
24VDC
264VDC
300VDC
RTK Cables
|
annunciator relay
Abstract: No abstract text available
Text: DRAFT 20 October 2014 Technical Data October 2014 EPS RTK Series 725 7 MTL Process Alarm Equipment RTK Series 725 Programmable Alarm Annunciator • Modular construction from 1 to 256 alarm channels • Multi-redundant design so there is no single point of failure
|
Original
|
PDF
|
RS485
annunciator relay
|
NFS-320-RBE
Abstract: NFS-320R DN-6933 DN-60054 NFC50 NFS-320
Text: DN-7112:K • A-14 NFS-320 Intelligent Addressable Fire Alarm System Intelligent Fire Alarm Control Panels General The NFS-320 intelligent Fire Alarm Control Panel is part of the ONYX Series of Fire Alarm Controls from NOTIFIER. In stand-alone or network configurations, ONYX Series products
|
Original
|
PDF
|
DN-7112
NFS-320
NFS-320
7112pho1
NFS-320â
NFS-320-RBE
NFS-320R
DN-6933
DN-60054
NFC50
|
din mount 35mm
Abstract: No abstract text available
Text: Loop-Powered Trip Alarm/ Current Loop Alarm ADTECH Analog-Digital Technology, Inc. The Adtech CLA 114 Loop-Powered Trip Alarm accepts 4-20 mA DC input and provides a relay contact output. The CLA loop-powered alarm does not require a separate DC or AC power supply source as conventional alarms
|
Original
|
PDF
|
ainc847401
AInc847401
A097A
din mount 35mm
|
Untitled
Abstract: No abstract text available
Text: SPA2 Programmable Current/Voltage and RTD/Thermocouple Limit Alarm Trips November 2013 Description The universal SPA2 Programmable Limit Alarm Trips provide on/off control, warn of unwanted process conditions, alarm on rate-of-change and provide emergency shutdown. Very versatile, they accept a
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: S3 SeriesTM Small Addressable Fire Alarm Control Panel The Gamewell-FCI S3 SeriesTM Fire Alarm System is an easy-touse, intelligent, fire alarm solution designed for small to mid-sized buildings. Analog technology delivers the benefits of a simple system installation, while a user-friendly touch-screen allows
|
Original
|
PDF
|
RS232
RS485
LCD-7100
ASM-16
ANU-48
|
CS2501
Abstract: No abstract text available
Text: GW-UDACT Universal Digital Alarm Communication Transmitter Description The Gamewell-FCI Universal Digital Alarm Communicator Transmitter GW-UDACT is designed for use with all Gamewell-FCI 600 Series Fire Alarm Control Panels. The GW-UDACT transmits the system status to UL-Listed Central Station Receivers via the public switched telephone
|
Original
|
PDF
|
RS-485
24-volt
CS-2501
CS2501
|
ANN-80
Abstract: GFANN-80
Text: GFANN-80 80-Character LCD Description The GFANN-80 annunciator is a compact, backlit 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel FACP display. It provides system Status indicators for AC power, Alarm, Trouble, Supervisory, and
|
Original
|
PDF
|
GFANN-80
80-Character
GFANN-80
GFANN-80-W)
GFANN-80-W
ANN-80
|
EOL-P1
Abstract: No abstract text available
Text: GE Security EST Fire & Life Safety Control Panels Overview Standard Features The FireShield fire alarm family consists of 3, 5 and 10 zone conventional fire alarm control panels, an integrated DACT/Dialer, serial annunciator modules, and serial remote relay modules. All of these
|
Original
|
PDF
|
12V4A
12V6A5
12V10A
12V17A
EOL-P1
|
Untitled
Abstract: No abstract text available
Text: RAN-400 Description Remote Annunciator The RAN-400 is the remote annunciator for the Flex 410 Fire Alarm Control Panel FACP . The RAN-400 performs all system operations. It also displays the trouble and the alarm information. In addition, you can use the RAN-400
|
Original
|
PDF
|
RAN-400
RAN-400
FLEX-410
CS-2486
|
cable centronics
Abstract: M1000
Text: H0300 Event Logger The SELCO H0300 Logger is a standalone logger system for the SELCO M1000C Alarm Annunciator, the M3000-30 Analog Alarm Annunciator, the SELCO M4780 Indicator and the SELCO H1500 Indicator Panel. • Stand-alone logger unit • Event log in display
|
Original
|
PDF
|
H0300
M1000C
M3000-30
M4780
H1500
M1000C,
M3000-30,
H1500
cable centronics
M1000
|
D8227
Abstract: D8203 D1260W D8128D
Text: Intrusion Alarm Systems | D7412GV2 Control Panel D7412GV2 Control Panel www.boschsecurity.com The D7412GV2 Control Panel provides an integrated solution for intrusion, access control, and fire alarm system applications. The control panel includes a communicator that sends event reports to selected
|
Original
|
PDF
|
D7412GV2
D5200
D9210BLC
D8227
D8203
D1260W
D8128D
|
Untitled
Abstract: No abstract text available
Text: Bulletin No. TLA-B Drawing No. LP0553 Released 06/13 Tel +1 717 767-6511 Fax +1 (717) 764-0839 www.redlion.net MODEL TLA - TEMPERATURE LIMIT ALARM FM APPROVED, UL RECOGNIZED 2-LINE BY 4-DIGIT DISPLAY EXCEED, OUTPUT, AND ALARM ANNUNCIATORS FOUR BUTTON SILICONE RUBBER KEYPAD
|
Original
|
PDF
|
LP0553
4X/IP65
E156876
201-B,
Sector-30
Gurgaon-122002
|
|
Untitled
Abstract: No abstract text available
Text: Alarm Monitoring Monitoring M3000 SERIES Analog Alarm Annunciator Description Simplified Circuit Diagram 11 IN 1 12 IN 2 101 INPUT GROUP 1 OPEN COLLECTOR OUTPUTS 13 IN 3 114 14 GND AL. OUT 115 SIREN 116 81 IN 1 82 IN 2 INPUT GROUP 8 83 IN 3 84 GND 120 + 121
|
Original
|
PDF
|
M3000
RS232
M3000
EN50081-1,
EN50082-1,
EN50081-2,
EN50082-2
EN61000-2-6
|
D5500C-USB
Abstract: No abstract text available
Text: Intrusion Alarm Systems | D9412GV3 Control Panel D9412GV3 Control Panel www.boschsecurity.com The D9412GV3 Control Panel delivers a powerful new solution for intrusion, access control, and fire alarm system applications. The control panel includes a communicator that sends events to selected public
|
Original
|
PDF
|
D9412GV3
D9210BLC
D5500C-USB
|
Untitled
Abstract: No abstract text available
Text: DIFFERENTIAL PRESSURE Room Pressure Monitors Model SRPM Room Pressure Monitor FEATURES • Touch Screen Display ■ BACnet Option ■ Password Enabled ■ Local Audible Alarm ■ Visual Red and Green Room Status Displays ■ SPST Alarm Relay ■ Door Status Monitor
|
Original
|
PDF
|
ANSI-Z540-1.
|
D5500
Abstract: No abstract text available
Text: Intrusion Alarm Systems | D7412GV3 Control Panel D7412GV3 Control Panel www.boschsecurity.com The D7412GV3 Control Panel delivers a powerful new solution for intrusion, access control, and fire alarm system applications. The control panel includes a communicator that sends event reports to selected
|
Original
|
PDF
|
D7412GV3
D9210BLC
D5500
|
Untitled
Abstract: No abstract text available
Text: 7200 Micro COMPACT ANALOG FIRE ALARM CONTROL PANEL DESCRIPTION The FCI 7200 Micro fire alarm control panel effectively combines multiprocessor analog system advantages with a compact design. Designed for commercial, industrial and institutional use, the 7200 Micro compact control panel is
|
Original
|
PDF
|
80-Column
|
Untitled
Abstract: No abstract text available
Text: RB7 Ultra Sensitive Relay Module Rev. DSRB7_11162012 Overview RB7 Multiple Relay Module incorporates seven 7 isolated form “C” relay outputs which can be activated via positive (+) low current trigger inputs. Typical applications include the switching of alarm devices (eg. annunciator, signals, etc.) from PGM outputs of alarm panels or from another source.
|
Original
|
PDF
|
12VDC
24VDC
120mA.
amp/120VACà
28VDCà
24VDC
|
Untitled
Abstract: No abstract text available
Text: Features Flex 404 Four-Zone Fire Alarm Control Panel g2404ph1.jpg Description The Gamewell Flex 404 Fire Alarm Control Panel brings the latest in microprocessor technology to conventional fire controls. The Flex 404 is compatible with the new i³ smoke
|
Original
|
PDF
|
g2404ph1
CS-2404
|
Untitled
Abstract: No abstract text available
Text: FC-5C FIVE ZONE PANEL Conventional Fire Alarm Control Description The FC-5C Fire Alarm Control panel is a proven, versatile, modular control with integral communicator and remotesite Upload/Download capability. It meets the requirements of NFPA Standard 72 for Central Station, Protected
|
Original
|
PDF
|
FC-10C:
ITI-CS-4000
CP220FB
3000R
|
fire alarm Gamewell Flex 300
Abstract: rj31x Ademco ademco express CP220FB Sescoa 3000R Radionics ademco 685 Gamewell fire alarm Gamewell Flex 300 manual
Text: Flex 405 Features Fire Alarm Control Panel with built-in DACT and remote-site upload/download capability Description g2405ph1.jpg The Gamewell Flex 405 is a 24-volt, five-zone Fire Alarm Control Panel FACP with built-in communicator and remote-site upload/download
|
Original
|
PDF
|
g2405ph1
24-volt,
CS-2405
fire alarm Gamewell Flex 300
rj31x
Ademco
ademco express
CP220FB
Sescoa 3000R
Radionics
ademco 685
Gamewell
fire alarm Gamewell Flex 300 manual
|
NEC Vacuum Fluorescent Display
Abstract: NEC FIP LD8164 FIP5E15S NEC LD8164 NEC FIP Vacuum display nec 1 x 40 vacuum fluorescent display digital clock with seconds and alarm time display fluorescent display nec led display alarm clock
Text: IC M 7223VF 3 - 1 /2 Digit Vacuum Fluorescent Clock Circuit With Snooze Timer and Sleep Timer GENERAL DESCRIPTION FEATURES • 3-1/2 digit display with AM/PM, sleep timer, and alarm flags • Direct alarm drive with complex cricket alarm tone plus radio enable for clock radio applications
|
OCR Scan
|
PDF
|
ICM7223VFIPL
ICM7223VF/D
ICM7223VF
300fi
100/jF
300ft
ICM7223VF
FIP5E15S)
NEC Vacuum Fluorescent Display
NEC FIP
LD8164
FIP5E15S
NEC LD8164
NEC FIP Vacuum display
nec 1 x 40 vacuum fluorescent display
digital clock with seconds and alarm time display
fluorescent display nec
led display alarm clock
|