centre tapped Transformer
Abstract: iron core transformer schematic balun transformer 75 ohm FERRITE TOROIDAL CORE DATA transformer winding reference center tap transformer ferrite core transformer transformer centre tap transformer with centre tapped secondary winding 50 Ohm transformer
Text: RF Transformers RF transformers are widely used in low-power electronic circuits for impedance matching to achieve maximum power transfer, for voltage step-up or step-down, and for isolating dc from two circuits while maintaining ac continuity. They are also used for common mode rejection and as baluns.
|
Original
|
|
PDF
|
balun transformer 75 ohm
Abstract: centertapped transformer three phase autotransformer iron core transformer schematic FERRITE TOROIDAL CORE DATA balun transformer 50ohm ferrite core transformer construction ISOLATION TRANSFORMER WINDING CONSTRUCTION transformer winding reference
Text: RF Transformers RF transformers are widely used in low-power electronic circuits for impedance matching to achieve maximum power transfer, for voltage step-up or step-down, and for isolating dc from two circuits while maintaining ac continuity. They are also used for common mode rejection and as baluns.
|
Original
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Test Procedure for the NCP1351 Adapter Evaluation Board 8/1/2007 1 Be careful when manipulating the boards in operation, lethal voltages up to 400V are present on the primary side. An isolation transformer is also recommended for safer manipulations. Necessary Equipment:
|
Original
|
NCP1351
265Vrms
380VDC
6060B)
|
PDF
|
transformer winding formula step down
Abstract: ac 2092 transformer calculation formula transformer winding formula Prem Magnetics line interactive transformer spw -055 transformer SPW-2100 spw transformer step down transformer design formula
Text: INCHES Power Transformer Specification Formulae Prem Magnetics, Inc. • 3521 North Chapel Hill Road • McHenry, IL 60050 • Tel: 815-385-2700 • Fax: 815-385-8578 • E-Mail: sales@premmag.com • Website: http://www.premmag.com ENGINEERS’ GUIDE TO INDUCTIVE COMPONENTS
|
Original
|
|
PDF
|
AN-41
Abstract: Power Integrations diode B25 NB b6 smd transistor b17 zener diode ALG B7 smd transistor transistor smd po3 transistor smd ALG pks606 PX 1N4007
Text: Application Note AN-41 PeakSwitch Design Guide modulated jitter to reduce EMI. In addition, the ICs have integrated functions that provide system-level protection. The auto-restart function limits the dissipation in the MOSFET, the transformer and the output diode during overload, output shortcircuit and open-loop conditions, while the auto-recovering
|
Original
|
AN-41
AN-41
Power Integrations
diode B25
NB b6 smd transistor
b17 zener diode
ALG B7 smd transistor
transistor smd po3
transistor smd ALG
pks606
PX 1N4007
|
PDF
|
Untitled
Abstract: No abstract text available
Text: T57 NA Dual Cord 35-40VA Transformer Series Features • • • • • • • • • • • 120 VAC Input NA Dual Cord Style Rated for Continuous Duty AC outputs up to 42VA Meets Safety Agency Requirements Complies with EMI/RFI Regulations Impact Resistant Polycarbonate Enclosure
|
Original
|
35-40VA
T57-094450-K000G
T57-123500-K000G
T57-152500-K000G
T57-241458-K000G
T57-241667-K000G
|
PDF
|
Untitled
Abstract: No abstract text available
Text: A57 Universal Desktop 30VA Transformer Series Features • • • • • • • • • • • • 230 VAC Input Euro Wall Plug Style Rated for Continuous Duty AC outputs up to 30VA Meets Safety Agency Requirements Complies with EMI/RFI Regulations CE Compliant
|
Original
|
EN60950
|
PDF
|
Untitled
Abstract: No abstract text available
Text: A57 Euro Dual Cord 30VA Transformer Series Features • • • • • • • • • • • • 230 VAC Input Euro Dual Cord Style Rated for Continuous Duty AC outputs up to 30VA Meets Safety Agency Requirements Complies with EMI/RFI Regulations CE Compliant
|
Original
|
EN60950
|
PDF
|
Untitled
Abstract: No abstract text available
Text: C48 UK Wall Mount 16-20VA Transformer Series Features • • • • • • • • • • • • 230 VAC Input UK Wall Plug Style Rated for Continuous Duty AC outputs up to 20VA Meets Safety Agency Requirements Complies with EMI/RFI Regulations CE Compliant
|
Original
|
16-20VA
EN60950
|
PDF
|
Untitled
Abstract: No abstract text available
Text: C57 UK Dual Cord 30VA Transformer Series Features • • • • • • • • • • • • 230 VAC Input UK Dual Cord Style Rated for Continuous Duty AC outputs up to 30VA Meets Safety Agency Requirements Complies with EMI/RFI Regulations CE Compliant
|
Original
|
C57ating
EN60950
|
PDF
|
Untitled
Abstract: No abstract text available
Text: C41 UK Wall Mount 8VA Transformer Series Features • • • • • • • • • • • • 230 VAC Input UK Wall Plug Style Rated for Continuous Duty AC outputs up to 8VA Meets Safety Agency Requirements Complies with EMI/RFI Regulations CE Compliant
|
Original
|
C41-061333-A000G
C41-071140-A000rating
EN60950
|
PDF
|
ict TRANSFORMER
Abstract: ADM1041 ADM1041A 1N4148 680R V068
Text: Secondary-Side Controller with Current Share and Housekeeping ADM1041A INTERFACE AND INTERNAL FEATURES FEATURES SMBus interface I2C-compatible Voltage-error amplifier Differential current sense Sense resistor or current transformer option Overvoltage protection
|
Original
|
ADM1041A
352-byte
160-byte
24-Lead
RQ-24
ict TRANSFORMER
ADM1041
ADM1041A
1N4148
680R
V068
|
PDF
|
RC115S
Abstract: RC-115S relay 3 legs
Text: Data Sheet RC-115S Momentary switch type relay 3 wire Each Remcon relay, unlike any other low voltage relay, has a built-in transformer for unit control. Each relay in the system operates independently from and has no effect upon other relays. You can economically install as little as one relay and
|
Original
|
RC-115S
877-AMPROBE
RC115S
RC-115S
relay 3 legs
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Data Sheet RC-120S Closet-light type relay 2 wire Each Remcon relay, unlike any other low voltage relay, has a built-in transformer for unit control. Each relay in the system operates independently from and has no effect upon other relays. You can economically install as little as one relay and
|
Original
|
RC-120S
877-AMPROBE
|
PDF
|
|
RC-120S
Abstract: No abstract text available
Text: Data Sheet RC-120S Closet-light type relay 2 wire Each Remcon relay, unlike any other low voltage relay, has a built-in transformer for unit control. Each relay in the system operates independently from and has no effect upon other relays. You can economically install as little as one relay and
|
Original
|
RC-120S
877-AMPROBE
RC-120S
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Secondary-Side Controller with Current Share and Housekeeping ADM1041A INTERFACE AND INTERNAL FEATURES FEATURES SMBus interface I2C-compatible Voltage-error amplifier Differential current sense Sense resistor or current transformer option Overvoltage protection
|
Original
|
ADM1041A
352-byte
160-byte
24-Lead
RQ-24
|
PDF
|
SLAA122
Abstract: msp430 for energy power factor measurement Indian Standards MSP430 SLAA075 SLAA024 digital phase shift
Text: Application Report SLAA122 – February 2001 Current-Transformer Phase-Shift Compensation and Calibration Kes Tam Mixed Signal Products ABSTRACT This application report demonstrates a digital technique to compensate and calibrate the phase shift of a current or voltage transformer used in electric power or energy
|
Original
|
SLAA122
16-bit
MSP430
SLAA122
msp430 for energy power factor measurement
Indian Standards
SLAA075
SLAA024
digital phase shift
|
PDF
|
750311880
Abstract: SLVU459 wurth max inverter 160 JESD22-A114A push pull converter TPS55010EVM-009
Text: TPS55010 SLVSAV0A – APRIL 2011 – REVISED JUNE 2011 www.ti.com 2.95V To 6V Input, 2W, Isolated DC/DC Converter with Integrated FETs Check for Samples: TPS55010 FEATURES DESCRIPTION • • • • • • • • • • The TPS55010 is a transformer driver designed to
|
Original
|
TPS55010
TPS55010
RS-485
RS-232,
750311880
SLVU459
wurth max inverter 160
JESD22-A114A
push pull converter
TPS55010EVM-009
|
PDF
|
pwm INVERTER 3 phase 400 hz vfd
Abstract: 75031 750311880
Text: TPS55010 SLVSAV0A – APRIL 2011 – REVISED JUNE 2011 www.ti.com 2.95V To 6V Input, 2W, Isolated DC/DC Converter with Integrated FETs Check for Samples: TPS55010 FEATURES DESCRIPTION • • • • • • • • • • The TPS55010 is a transformer driver designed to
|
Original
|
TPS55010
TPS55010
RS-485
RS-232,
pwm INVERTER 3 phase 400 hz vfd
75031
750311880
|
PDF
|
Untitled
Abstract: No abstract text available
Text: TPS55010 SLVSAV0A – APRIL 2011 – REVISED JUNE 2011 www.ti.com 2.95V To 6V Input, 2W, Isolated DC/DC Converter with Integrated FETs Check for Samples: TPS55010 FEATURES DESCRIPTION • • • • • • • • • • The TPS55010 is a transformer driver designed to
|
Original
|
TPS55010
TPS55010
RS-485
RS-232,
|
PDF
|
smd diode K10
Abstract: switching transformer 300w fuse 6.3A 250v IR1150 800V dc to dc boost converter 019-4119-00 C8100 10BQ040N SIL-PAD to-247 330uf 450v
Text: Computing & Communications SBU - AC-DC APPLICATIONS GROUP 101 N.Sepulveda Blvd., EL Segundo 90245 CALIFORNIA, USA IRAC1150-300W Demo Board User’s Guide Rev.2.2 3/29/2005 Rev. 2.2 3/29/2005 International Rectifier Page 1 of 17 Table of Contents 1
|
Original
|
IRAC1150-300W
CISPR-22
115VAC
smd diode K10
switching transformer 300w
fuse 6.3A 250v
IR1150
800V dc to dc boost converter
019-4119-00
C8100
10BQ040N
SIL-PAD to-247
330uf 450v
|
PDF
|
Untitled
Abstract: No abstract text available
Text: RF Transformers RF transformers are widely used in low-power elec tronic circuits for impedance matching to achieve maximum power transfer, for voltage step-up or step-down, and for isolating dc from tw o circuits while maintaining ac continuity. They are also used
|
OCR Scan
|
|
PDF
|
Untitled
Abstract: No abstract text available
Text: 001 DTC-19300 ILC DATA DEVICE CORPORATION _ _ LVDT/RVDT-TO-DIGITAL CONVERTER FEATURES DESCRIPTION The DTC-19300 is a 12- or 14-bit LVDT Linear Variable D ifferential Transform er - or RVDT (R otary Variable Differential Transformer)-todigital converter which also supplies
|
OCR Scan
|
DTC-19300
DTC-19300
14-bit
36-pin
MIL-STD-883
|
PDF
|
motor resolver
Abstract: AD2S80 motor gearbox 2S80 RSCT1621 AD2S82A tap control transformer AD2S80A microprocessor in ROBOT SYSTEMS sinusoidal motors
Text: r « ANALOG DEVICES AN-203 APPLICATION NOTE Li ONE TECHNOLOGY WAY • P.O. BOX 9106 • NORWOOD, MASSACHUSETTS 02062-9106 • 617/329-4700 Using the AD2S80A Series Resolver-to-Digital Converters As a Control Transformer By John Christacopoulos INTRODUCTION
|
OCR Scan
|
AN-203
AD2S80A
AD2S80A,
AD2S81A
AD2S82A
8-/16-Bit
AD2S80A
motor resolver
AD2S80
motor gearbox
2S80
RSCT1621
tap control transformer
microprocessor in ROBOT SYSTEMS
sinusoidal motors
|
PDF
|