TM0030 Search Results
TM0030 Datasheets Context Search
Catalog Datasheet | Type | Document Tags | |
---|---|---|---|
1G04Contextual Info: POWER LINE CHOKES TM0030 Space and Creepage distance between coil and coil is 3.2 mm minimum. M E C H A N I Space and creepage distance between coil and core is 2.0mm minimum. Max bel lltt irnn DateCode 0 571-0013-XX 1.10 27.94 Max f 0.394(10.01) 0.75(19.05) |
OCR Scan |
TM0030 571-0013-XX 1G-04 2000Vrms 1G04 | |
Contextual Info: ADSL Magnetics For Fujitsu IC MB86670 Keywave • Operating temperature range: -40° C to +85° C • Meets IEC 695, 2-2 flammability requirements TM00308 • PWB Process Capability: standard printed wiring board assembly techniques, total-immersion cleaning |
Original |
MB86670 TM00308 S560-6600-L7 T3-30 | |
smd a7
Abstract: Globespan S560-6600-A7 smd fuse
|
Original |
TM00309 UL1950 IEC950 S560-6600-A7 T3-32 smd a7 Globespan S560-6600-A7 smd fuse | |
Contextual Info: defining a degree of excellence POWER LINE CHOKES TM0030 * Space and Creepage distance between coil and coil is 3.2 mm minimum. M E C H A N I C A L S * Space and creepage distance between coil and core is 2.0mm minimum. 0.90 22.86 Max 1 1.10(27.94) Max Date Code |
Original |
TM0030 0571-0013-XX 2000Vrms | |
smd k8
Abstract: a6 smd EP10 equivalent t34 smd MTK20130 MTK-20150 S560-6600-A6 RM8 fuse SMD fuse 110 bel isolation
|
Original |
TM00300 T3-12 smd k8 a6 smd EP10 equivalent t34 smd MTK20130 MTK-20150 S560-6600-A6 RM8 fuse SMD fuse 110 bel isolation | |
S560-6600-L7
Abstract: BT8973 0560-6600-J6 BT8970 S560-6600-68 T3-27
|
Original |
BT8970 BT8973 TM00307 Ratio0-60 T3-28 S560-6600-L7 BT8973 0560-6600-J6 S560-6600-68 T3-27 | |
t3.15 a fuse
Abstract: t3.15 250v TM00301 0560-6600-C7 0560-6600-H6 0560-6600-J4 0560-6600-M3 S560-6600-A6 S560-6600-D6 S560-6600-G1
|
Original |
AMDSL134 TM00301 T3-16 t3.15 a fuse t3.15 250v TM00301 0560-6600-C7 0560-6600-H6 0560-6600-J4 0560-6600-M3 S560-6600-A6 S560-6600-D6 S560-6600-G1 | |
0560-6600-A5
Abstract: 0560-6600-H2 S560-6600-L8 S560-6600-P5 smd fuse 15 t3-25 p5 smd
|
Original |
TM00306 S560-6600-L8 600-H2 T3-26 0560-6600-A5 0560-6600-H2 S560-6600-L8 S560-6600-P5 smd fuse 15 t3-25 p5 smd | |
B3 smd
Abstract: u 741 0560-6600-A1 AD20MSP918 S560-6600-B3
|
Original |
AD20MSP918 TM00304 T3-22 B3 smd u 741 0560-6600-A1 AD20MSP918 S560-6600-B3 | |
t317
Abstract: "analog devices" 8F h d 2001 u 741 AD20MSP910 S560-6600-30 T318
|
Original |
AD20MSP910 EN60950 E150991 S560-6600-30 TM00302 T3-18 t317 "analog devices" 8F h d 2001 u 741 AD20MSP910 T318 | |
tm003Contextual Info: ADSL Magnetics For Analog Devices AD20MSP918 • Designed to meet IEC 950 safety requirements for supplementary insulation at 250V • Minimum interwinding breakdown voltage of 1500 Vrms • A CO application using the AD20MSP918 requires one each of the S560-6600-30 or 0560-6600-63 and S5606600-35 or 0560-6600-62 to complete the design |
Original |
AD20MSP918 AD20MSP918 S560-6600-30 S5606600-35 TM00303 T3-20 tm003 | |
Contextual Info: ADSL Magnetics For Analog Devices AD20MSP910 • Designed to meet IEC 950 safety requirements for supplementary insulation at 250V • Minimum interwinding breakdown voltage of 1500 Vrms CO and CPE applications require two each of the S560-6600-30 or 0560-6600-63 |
Original |
AD20MSP910 S560-6600-30 TM00302 T3-20 | |
fuse F4 250V
Abstract: T324 S560-6600-F5 TM00305 0560-6600-E5 "analog devices" 8F AD20MSP930 S560-6600-F3 S560-6600-F4 S560-6600-F6
|
Original |
AD20MSP930 TM00305 S560-6600-F3 0560-6600-E4 S560-6600-F4 0560-6600-E5 S560-6600-E7 T3-24 fuse F4 250V T324 S560-6600-F5 TM00305 0560-6600-E5 "analog devices" 8F AD20MSP930 S560-6600-F3 S560-6600-F4 S560-6600-F6 |