Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    5972RH Search Results

    5972RH Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    MSK5972

    Abstract: 5972RH
    Text: MIL-PRF-38534 CERTIFIED M.S.KENNEDY CORP. RAD HARD 1.5A, ADJUSTABLE LINEAR REGULATOR 5972RH 315 701-6751 4707 Dey Road Liverpool, N.Y. 13088 FEATURES: Manufactured using Space Qualified RH 117 Die Total Dose Tested to 150 Krads(Si) (Method 1019.7 Condition A)


    Original
    PDF MIL-PRF-38534 5972RH O-257 5972RH MSK5972

    Untitled

    Abstract: No abstract text available
    Text: MIL-PRF-38534 CERTIFIED M.S.KENNEDY CORP. RAD HARD 1.5A, ADJUSTABLE LINEAR REGULATOR 5972RH 315 701-6751 4707 Dey Road Liverpool, N.Y. 13088 FEATURES: Manufactured using Space Qualified RH 117 Die Total Dose Tested to TBD Krads(Si) (Method 1019.7 Condition A)


    Original
    PDF MIL-PRF-38534 5972RH O-257 5972RH

    5962R09213

    Abstract: voltage regulator 10V smd smd linear regulator
    Text: MIL-PRF-38534 CERTIFIED FACILITY M.S.KENNEDY CORP. RAD HARD 1.5A, ADJUSTABLE LINEAR REGULATOR 5972RH 315 701-6751 4707 Dey Road Liverpool, N.Y. 13088 FEATURES: Manufactured using Space Qualified RH 117 Die Total Dose Hardened to 100 Krads(Si) (Method 1019.7 Condition A)


    Original
    PDF MIL-PRF-38534 5972RH 5962R09213 O-257 5972RH MSK5972 5962R09213 voltage regulator 10V smd smd linear regulator

    Untitled

    Abstract: No abstract text available
    Text: MIL-PRF-38534 CERTIFIED M.S.KENNEDY CORP. RAD HARD 1.5A, ADJUSTABLE LINEAR REGULATOR 5972RH 315 701-6751 4707 Dey Road Liverpool, N.Y. 13088 FEATURES: Manufactured using Space Qualified RH 117 Die Total Dose Tested to TBD Krads(Si) (Method 1019.7 Condition A)


    Original
    PDF MIL-PRF-38534 5972RH O-257 5972RH

    Untitled

    Abstract: No abstract text available
    Text: MIL-PRF-38534 CERTIFIED M.S.KENNEDY CORP. RAD HARD 1.5A, ADJUSTABLE LINEAR REGULATOR 5972RH 4707 Dey Road Liverpool, N.Y. 13088 315 701-6751 FEATURES: Manufactured using Space Qualified RH 117 Die Total Dose Tested to TBD Krads(Si) (Method 1019.7 Condition A)


    Original
    PDF MIL-PRF-38534 5972RH 5972RH

    Untitled

    Abstract: No abstract text available
    Text: MIL-PRF-38534 CERTIFIED M.S.KENNEDY CORP. RAD HARD 1.5A, ADJUSTABLE LINEAR REGULATOR 5972RH 315 701-6751 4707 Dey Road Liverpool, N.Y. 13088 FEATURES: Manufactured using Space Qualified RH 117 Die Total Dose Hardened to 100 Krads(Si) (Method 1019.7 Condition A)


    Original
    PDF MIL-PRF-38534 5972RH O-257 5972RH MSK5972