Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    37KW MOTOR Search Results

    37KW MOTOR Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TB67H451AFNG Toshiba Electronic Devices & Storage Corporation Brushed Motor Driver/1ch/Vout(V)=50/Iout(A)=3.5 Visit Toshiba Electronic Devices & Storage Corporation
    TB67H450AFNG Toshiba Electronic Devices & Storage Corporation Brushed Motor Driver/1ch/Vout(V)=50/Iout(A)=3.5 Visit Toshiba Electronic Devices & Storage Corporation
    TB67S580FNG Toshiba Electronic Devices & Storage Corporation Stepping Motor Driver/Unipolar Type/Vout(V)=50/Iout(A)=1.6 Visit Toshiba Electronic Devices & Storage Corporation
    TB67S581FNG Toshiba Electronic Devices & Storage Corporation Stepping Motor Driver/Unipolar Type/Vout(V)=50/Iout(A)=2.5 Visit Toshiba Electronic Devices & Storage Corporation
    TB67Z833SFTG Toshiba Electronic Devices & Storage Corporation Brushed Motor Driver / 3-Phase Brushless Motor Gate Driver / VVM(V)=-0.3~80 / P-WQFN40-0606-0.50-003 Visit Toshiba Electronic Devices & Storage Corporation

    37KW MOTOR Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    wiring diagram slip ring motor resistance starter

    Abstract: fuse 9 BJE 69 testing soft starter 37 MTE powersoft 37 MTE soft starter wiring diagram to hold contactor with NO, NC AC 240V Motor Speed Controller wiring diagram slip ring motor 415V AC slip ring motor characteristics curve 3 phase motor soft starter diagram
    Text: POWERSOFT MN SERIES ELECTRONIC MOTOR CONTROLLERS 4kW to 37kW TECHNICAL MANUAL 1E February 1997 2 Contents 1. Introduction 1. Introduction Page 2 2. T echnical sp ecification Page 3 3. Principles of o peration Page 3 4. Selection guide Page 5 PowerSoft MN Series is a low cost soft starter and controller for 3phase m otors up to 37kW. Each phase of the m otor is fully controlled


    OCR Scan
    PDF

    moeller DILM80

    Abstract: DILM115 DILM15 DILM150 DILM170 DILM32 DILM80 150 KW motor 37 KW motor DC 3 DUTY CONTACTOR
    Text: Type: DILM80 24V50HZ Article No.: 235904 Sales text Contactor,37kW/400V,AC operated Ordering information Connection technique Screw terminals Description 3 pole Description Springloaded terminals on the auxiliary and control circuit terminals Rated operational current


    Original
    DILM80 24V50HZ) 37kW/400V D-53115 HPL-C2007G moeller DILM80 DILM115 DILM15 DILM150 DILM170 DILM32 150 KW motor 37 KW motor DC 3 DUTY CONTACTOR PDF

    wiring diagram slip ring motor resistance starter

    Abstract: 3 phase motor soft starter circuit diagram wiring 3 phase dol starter with emergency stop 37 MTE powersoft 24v dc soft start motor control diagram wiring diagram slip ring motor BS4265 wiring diagram dol motor reversing starter how to install wiring DOL starter important principles of fault finding in thyristor
    Text: Issued July 1999 232-4572 Data Pack B Powersoft MN Series Data Sheet Supplied to RS by MTE Ltd Electronic Motor Controllers 4kW to 37kW RS stock numbers 279-4230, 279-4246, 279-4252, 279-4268 Contents 1. 2. 3. 4. 5. Introduction Technical specification Principles of operation


    Original
    PDF

    wiring diagram dol motor starter

    Abstract: 3phase winding data 3.7 kw to 110 kw DOL wiring diagram motor 5.5KW motor wiring diagram DOL starter wiring diagram motor dol motor starter wiring diagram 400v 3KW motor circuit 11KW 3 phase motor 5.5KW motor 7.5KW motor resistance
    Text: PBP3-400 Description 3.0 kW complete dc injection brake unit without starter, for production braking PBP is a range of self-contained D.C. Injection Production Brakes for use with an existing DOL Starter. It is suitable for 400V three-phase motors from 3.0 to 75 kW.


    Original
    PBP3-400 100FE 140FE 180FE 225FE wiring diagram dol motor starter 3phase winding data 3.7 kw to 110 kw DOL wiring diagram motor 5.5KW motor wiring diagram DOL starter wiring diagram motor dol motor starter wiring diagram 400v 3KW motor circuit 11KW 3 phase motor 5.5KW motor 7.5KW motor resistance PDF

    wiring diagram dol motor starter

    Abstract: wiring 3 phase dol starter with overload diagram wiring diagram dol starter DOL wiring diagram motor DOL starter wiring diagram wiring start dol DOL starter wiring diagram motor dol motor starter wiring diagram wiring diagram start dol three-phase 3kw ac motor speed control circuit diagram
    Text: Technical Specification English Powerbrake PBP Range DC Injection Production Brakes for existing DOL Starters Powerbrake PBP is a range of self-contained D.C. Injection Production Brakes for use with an existing DOL Starter. It is suitable for 400V three-phase motors from 3.0 to 75 kW.


    Original
    012263/3E/302 wiring diagram dol motor starter wiring 3 phase dol starter with overload diagram wiring diagram dol starter DOL wiring diagram motor DOL starter wiring diagram wiring start dol DOL starter wiring diagram motor dol motor starter wiring diagram wiring diagram start dol three-phase 3kw ac motor speed control circuit diagram PDF

    wiring 3 phase dol starter with emergency stop

    Abstract: wiring diagram dol motor starter 55Kw motor wiring diagram dol starter mte powerbrake 5.5KW motor wiring diagram 37Kw motor 15KW motor wiring diagram 110v dc motor control circuit 400v 3KW motor circuit
    Text: Technical Specification English Issue 4 Panel hardware: Fault indicator lamp amber START button (I) STOP/RESET button (O) (overload reset) Powerbrake PBPS Range DC Injection Production Brakes Powerbrake PBPS is a range of self-contained D.C. Injection


    Original
    012262/4E/502 wiring 3 phase dol starter with emergency stop wiring diagram dol motor starter 55Kw motor wiring diagram dol starter mte powerbrake 5.5KW motor wiring diagram 37Kw motor 15KW motor wiring diagram 110v dc motor control circuit 400v 3KW motor circuit PDF

    nais inverter vf c operation manual

    Abstract: nais VF-8X regenerative braking manual vf-8x inverter nais VF-8X 37KW motor wiring diagram FORWARD REVERSE 3 PHASE MOTOR 3 wiring control diagram with run and jog features 3 phase regenerative braking nais inverter VF-8X
    Text: VF-8X Series Extremely reliable, powerful and quiet inverters • Frequency Skip Feature: Vibrations resulting from resonance with associated facilities are prevented by skipping resonant frequencies. Up to three frequencies can be skipped, and the skip frequency span can be adjusted by the user.


    Original
    11-37kw nais inverter vf c operation manual nais VF-8X regenerative braking manual vf-8x inverter nais VF-8X 37KW motor wiring diagram FORWARD REVERSE 3 PHASE MOTOR 3 wiring control diagram with run and jog features 3 phase regenerative braking nais inverter VF-8X PDF

    5.5KW motor FUSE RATING

    Abstract: wiring diagram dol motor starter 5.5KW motor wiring diagram wiring diagram dol starter 7.5KW motor resistance DOL starter wiring diagram motor DOL wiring diagram motor 37KW motor wiring diagram dol motor starter wiring diagram 55Kw motor
    Text: Technical Specification English Powerbrake Issue 3 PBC Range DC Injection Critical Brakes Panel hardware: Fault indicator lamp amber RESET button Powerbrake PBC is a range of self-contained D.C. Injection Critical


    Original
    012261/3E/302 5.5KW motor FUSE RATING wiring diagram dol motor starter 5.5KW motor wiring diagram wiring diagram dol starter 7.5KW motor resistance DOL starter wiring diagram motor DOL wiring diagram motor 37KW motor wiring diagram dol motor starter wiring diagram 55Kw motor PDF

    37KW

    Abstract: RPH-500 power supply 350W
    Text: POWER SOLUTIONS - WILLOW TECHNOLOGIES LTD Lead Free 500W WATER COOLING NON-INDUCTIVE HIGH POWER RESISTORS RPH-500 Features and Applications Small size 500W water-cooled non-inductive resistor with very low resistor temperature under operation. Flat plate resistance and twisted pair leads and special terminal structure patent have shown excellent


    Original
    RPH-500 /-250ppm/K 37KW RPH-500 power supply 350W PDF

    inverter+500w+project+report

    Abstract: No abstract text available
    Text: POWER - NIKKOHM 500W WATER COOLING NON-INDUCTIVE HIGH POWER RESISTORS RPH500 Features and Applications Small sized 500W water-cooled non-inductive resistor with a very low resistor temperature under operation. Flat plate resistance and twisted pair leads and special terminal structure patent are shown excellent


    Original
    RPH500 RPH500 inverter+500w+project+report PDF

    IEC408

    Abstract: IEC947-3 iec 947 - 3 VDE 0660 -107 IEC408- AC22 690v Electrical motor ,690V NH00 125A IEC947 nh00 fuse 125A AC22 IEC-947
    Text: Bussmann Unenclosed Fused Switch 63 and 125A Suitable for NH style Fuse Links BDNHP Conforms to IEC 947 Regulations and Standards for NH square bodied Fuse Links or equivalent. VDE 0113, IEC204, IEC408 VDE 0660, Part 107 IEC 947-1 and 3 EN 60947-1 and 3


    Original
    IEC204, IEC408 70mm2 215mm) IEC947-3 iec 947 - 3 VDE 0660 -107 IEC408- AC22 690v Electrical motor ,690V NH00 125A IEC947 nh00 fuse 125A AC22 IEC-947 PDF

    dil3m

    Abstract: 3 phase, 415v and 270 kw motor DIL0M DIL00M wiring diagram contactor 7.5KW 3 phase motor 440v star delta wiring diagram motor dil2m DIL2AM DIL1M
    Text: Issued July 1993 B15333 Controlgear components ÔDIL M range The RS ÔDIL MÕ range of control gear components has been designed to meet modern requirements for heating, lighting and motor control. The components are manufactured to exceed the highest standards required in Europe and North America. They are suitable


    Original
    B15333 A-11kW dil3m 3 phase, 415v and 270 kw motor DIL0M DIL00M wiring diagram contactor 7.5KW 3 phase motor 440v star delta wiring diagram motor dil2m DIL2AM DIL1M PDF

    telemecanique LR2-D13

    Abstract: LR2-D13 LR2-D13 Telemecanique VDE 0660 - 107 telemecanique lr2d13 overload contactor LR2-D13 IEC 158-1 VDE 0660 LR2D13 telemecanique thermal overload relay trip test solid state timer relays telemecanique
    Text: Issued March 1999 291-9855 Data Pack B Data Sheet The Telemecanique ‘d2’ range of motor control gear The RS ‘d2’ range is a broad and versatile range of motor control gear for the many and varied control applications demanded in a world of increasing


    Original
    1970s. co237 telemecanique LR2-D13 LR2-D13 LR2-D13 Telemecanique VDE 0660 - 107 telemecanique lr2d13 overload contactor LR2-D13 IEC 158-1 VDE 0660 LR2D13 telemecanique thermal overload relay trip test solid state timer relays telemecanique PDF

    power window motor 12v

    Abstract: wiper motor 12v dc PWM generator for IGBT 12v dc driver motor control mosfet ELECTRONIC BALLAST 12v window lift motor rain sensor "rain sensor" 12v dc motor igbt control motor power window hall sensor
    Text: HIGH INTENSITY DISCHARGE H.I.D. LAMPS 100V Power MOSFET: STB50NE10 4 High voltage (breakdown at 500V) power transistor. Switch selection: IGBT: STGD3NB60SD Power MOSFET: STB9NB50 DC/DC Converter 12V 70V 12V B.C.C. 450 Hz / 50% duty cicle Transformer + Clamping


    Original
    STB50NE10 STGD3NB60SD STB9NB50 O-220 STP80NE03L-06 STB80o STB80NF55L-06 OT-223 PowerSO-10TM O-220 power window motor 12v wiper motor 12v dc PWM generator for IGBT 12v dc driver motor control mosfet ELECTRONIC BALLAST 12v window lift motor rain sensor "rain sensor" 12v dc motor igbt control motor power window hall sensor PDF

    Untitled

    Abstract: No abstract text available
    Text: HIGH POWER RESISTOR – Water Cooling, Non-Inductive HOW TO ORDER RWC 50 - 102 K B Packaging B = bulk FEATURES Tolerance K= +10% Small size 500W, 1Kw, and 2Kw water-cooled non-inductive resistor with very low resistor temperature while in operation Flat plate resistance and twisted pair leads and special terminal


    Original
    RWC50A) RWC50A RWC50B RWC100 RWC200 PDF

    3 phase motor soft starter circuit diagram

    Abstract: induction motor soft starter 3 phase motor soft starter diagram soft start motor control diagram AC Motor soft start AC53a 170M3116 3 phase motor soft starter circuit RSMR4072 stop start ac motors
    Text: Motor Controllers AC Semiconductor Motor Controller Type RSMR • Soft starting and stopping of 3-phase squirrel cage motors • 2 Phase controlled without bypass relay • Reliable microprocessor control • 10 pre-programmed ramping profiles • Rated operational voltage up to 480VAC, 50/60 Hz


    Original
    480VAC, AC-53a 3 phase motor soft starter circuit diagram induction motor soft starter 3 phase motor soft starter diagram soft start motor control diagram AC Motor soft start AC53a 170M3116 3 phase motor soft starter circuit RSMR4072 stop start ac motors PDF

    5.5KW SIEMENS motor

    Abstract: silcovert vlt 2800 yaskawa inverter 3.7KW SIEMENS motor toshiba electric motor data sheet 90kW toshiba electric motor 90kW 5.5KW induction motor abb servo motor drive AC servo motor controlled by inverter
    Text: 1 I N D U S T R I A L P O W E R Motor DRIVES Meet Changing Demands by Tara Lynn Macdonald M OTION CONTROL has recently emerged as a dynamic technology in manufacturing, partly because of the ongoing shift from mechanical control systems toward electronic servo control


    Original
    380kW, 450kW 600kW 5.5KW SIEMENS motor silcovert vlt 2800 yaskawa inverter 3.7KW SIEMENS motor toshiba electric motor data sheet 90kW toshiba electric motor 90kW 5.5KW induction motor abb servo motor drive AC servo motor controlled by inverter PDF

    VDE 0660 kraus and Naimer

    Abstract: kraus and naimer C42 VDE 0660 -107 kraus and Naimer VDE 0660. 107 slip ring motor IEC EN 60947- 3 VDE 0660 107 18.5KW motor 1KW 3 phase ac motor VDE 0660 - 107 VDE 0660 3 phase switch
    Text: KRAUS & NAIMER C42 - Electrical Data 1.12.2006 Switch features: - S1 64x64mm Front element size (can be changed by mountings and optional extras) - Terminal screws accessible laterally (resp. from above and below for -V mountings) - Designed for vertical wiring (resp. horizontal for -V mountings: e.g. VE-V, FS1-V)


    Original
    64x64mm) 2x16mm2 2x10mm2 VDE 0660 kraus and Naimer kraus and naimer C42 VDE 0660 -107 kraus and Naimer VDE 0660. 107 slip ring motor IEC EN 60947- 3 VDE 0660 107 18.5KW motor 1KW 3 phase ac motor VDE 0660 - 107 VDE 0660 3 phase switch PDF

    3 phase motor auto starter circuit diagram

    Abstract: wiring diagram single phase dol starter AT66A single phase DOL starter wiring soft starter wiring integral starter is 2000 diagram dol starter 3 phase motor auto DOL starter circuit diagram wiring diagram dol starter
    Text: C€ Technical Specification PAIR Motor Protection Relay Response characteristics Overload trip characteristic PAIR is designed for use with motors which require protection against both overtoad and underload conditions. Pump motors, for example, require normal overload protection, but the pump itself can be damaged


    OCR Scan
    PDF

    telemecanique LR2-D13

    Abstract: VDE 0660 iec 158-1 LR2-D13 Telemecanique Contactor JEM AC3 telemecanique IEC 158-1 IEC 158-1 VDE 0660 overload contactor LR2-D13 lr2d13 OVERLOAD lr2-d13 VDE 0660 BS 5424
    Text: Issued November 1991 B12564 The Telemecanique Ôd2Õ range of motor control gear The RS Ôd2Õ range is a broad and versatile range of motor control gear for the many and varied control applications demanded in a world of increasing automation complexity and improvements in reliability. Ôd2Õ is the first complete range to have been


    Original
    B12564 24Vdc 400Hz 50/60Hz A-32A 4-48V 0-127V 10-240V 0A-80A telemecanique LR2-D13 VDE 0660 iec 158-1 LR2-D13 Telemecanique Contactor JEM AC3 telemecanique IEC 158-1 IEC 158-1 VDE 0660 overload contactor LR2-D13 lr2d13 OVERLOAD lr2-d13 VDE 0660 BS 5424 PDF

    PM400DVA060

    Abstract: 37KW E80276 Servo Motor forward revers control
    Text: MITSUBISHI MITSUBISHI <INTELLIGENT <INTELLIGENT POWER POWER MODULES> MODULES> PM400DVA060 PM400DVA060 FLAT-BASE FLAT-BASE TYPE TYPE INSULATED INSULATED PACKAGE PACKAGE PM400DVA060 FEATURE • 1φ 400A, 600V Current-sense IGBT for 20kHz switching • Monolithic gate drive & protection logic


    Original
    PM400DVA060 20kHz E80276 E80271 PM400DVA060 37KW Servo Motor forward revers control PDF

    37KW

    Abstract: PM200DVA120 E80276
    Text: MITSUBISHI MITSUBISHI <INTELLIGENT <INTELLIGENT POWER POWER MODULES> MODULES> PM200DVA120 PM200DVA120 FLAT-BASE FLAT-BASE TYPE TYPE INSULATED INSULATED PACKAGE PACKAGE PM200DVA120 FEATURE • 3φ 200A, 1200V Current-sense IGBT for 20kHz switching • Monolithic gate drive & protection logic


    Original
    PM200DVA120 20kHz E80276 E80271 37KW PM200DVA120 PDF

    PM200DVA120

    Abstract: 37KW E80276
    Text: MITSUBISHI MITSUBISHI <INTELLIGENT <INTELLIGENT POWER POWER MODULES> MODULES> PM200DVA120 PM200DVA120 FLAT-BASE FLAT-BASE TYPE TYPE INSULATED INSULATED PACKAGE PACKAGE PM200DVA120 FEATURE • 1φ 200A, 1200V Current-sense IGBT for 20kHz switching • Monolithic gate drive & protection logic


    Original
    PM200DVA120 20kHz E80276 E80271 PM200DVA120 37KW PDF

    Untitled

    Abstract: No abstract text available
    Text: MITSUBISHI MITSUBISHI <INTELLIGENT <INTELLIGENT POWER POWER MODULES> MODULES> PM200DVA120 PM200DVA120 FLAT-BASE FLAT-BASE TYPE TYPE INSULATED INSULATED PACKAGE PACKAGE PM200DVA120 FEATURE • 1φ 200A, 1200V Current-sense IGBT for 20kHz switching • Monolithic gate drive & protection logic


    Original
    PM200DVA120 20kHz E80276 E80271 PDF