B84320-Z10-H35
Abstract: B84320-Z10-H33
Text: EMP Protection Units B84320-Z10-H33 Analog Communication and Control Lines B84320-Z10-H35 EMP-Schutzeinheiten General The EMP protection unit is sequenced, i.e. to use simultaneously the benefits of inert-gas-filled surge arresters extremely high surge capability and of varistors (fast response). They are isolated
|
Original
|
PDF
|
B84320-Z10-H33
B84320-Z10-H35
B84320-Z10sent
B84320-Z10-H35
|
B4-A350X
Abstract: B88069X3980C102
Text: Surge Arrester 2-Electrode-Arrester DC spark-over voltage B4-A350X Ordering code: B88069X3980C102 1 2) 350 ± 20 V % Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution < 800 < 700 V V Nominal impulse discharge current wave 8/20 µs)
|
Original
|
PDF
|
B4-A350X
B88069X3980C102
B4-A350X
B88069X3980C102
|
Epcos 1000 12 O
Abstract: din 2859 ES1000XN IEC 60068-1 SURGE ARRESTER
Text: Surge Arrester 2-Electrode-Arrester ES1000XN Ordering code: B88069X4391T103 DC spark-over voltage 1 2) 3) 1000 ± 20 V % Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution < 1400 < 1200 V V Single impulse discharge current
|
Original
|
PDF
|
ES1000XN
B88069X4391T103
57845/VDE0845
Epcos 1000 12 O
din 2859
ES1000XN
IEC 60068-1
SURGE ARRESTER
|
EPCOS 350 03
Abstract: surge arrester diode B4 B4-A350X B88069X3980C102
Text: Surge Arrester 2-Electrode-Arrester B4-A350X Ordering code: B88069X3980C102 DC spark-over voltage 1 2) 350 ± 20 V % Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution < 800 < 700 V V Nominal impulse discharge current wave 8/20 µs)
|
Original
|
PDF
|
B4-A350X
B88069X3980C102
EPCOS 350 03
surge arrester
diode B4
B4-A350X
B88069X3980C102
|
din 2859
Abstract: SM350XT
Text: Surge Arrester 2-Electrode-Arrester SM350XT Ordering code: B88069X4271B103 DC spark-over voltage 1 2) 340 … 440 V Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution < 650 < 550 V V < 750 < 650 V V Nominal impulse discharge current wave 8/20 µs)
|
Original
|
PDF
|
SM350XT
B88069X4271B103
57845/VDE0845
din 2859
SM350XT
|
ES260XP
Abstract: No abstract text available
Text: Surge Arrester 2-Electrode-Arrester ES260XP Ordering code: B88069X5920B502 DC spark-over voltage 1 2) 220 … 320 V Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution < 500 < 450 V V < 600 < 550 V V Nominal impulse discharge current wave 8/20 µs)
|
Original
|
PDF
|
ES260XP
B88069X5920B502
57845/VDE0845
ES260XP
|
SM300XN
Abstract: marking code SM diode
Text: Surge Arrester 2-Electrode-Arrester SM300XN Ordering code: B88069X3821B103 DC spark-over voltage 1 2) 250 … 345 V Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution < 500 < 450 V V < 600 < 580 V V Nominal impulse discharge current wave 8/20 µs)
|
Original
|
PDF
|
SM300XN
B88069X3821B103
57845/VDE0845
SM300XN
marking code SM diode
|
DISTRIBUTION
Abstract: ES260XP
Text: Surge Arrester 2-Electrode-Arrester ES260XP Ordering code: B88069X5920B502 DC spark-over voltage 1 2) 220 … 320 V Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution < 500 < 450 V V < 600 < 550 V V Nominal impulse discharge current wave 8/20 µs)
|
Original
|
PDF
|
ES260XP
B88069X5920B502
57845/VDE0845
DISTRIBUTION
ES260XP
|
marking code SM diode
Abstract: SM350XN
Text: Surge Arrester 2-Electrode-Arrester SM350XN Ordering code: B88069X3811B103 DC spark-over voltage 1 2) 340 … 440 V Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution < 550 < 480 V V < 650 < 580 V V Nominal impulse discharge current wave 8/20 µs)
|
Original
|
PDF
|
SM350XN
B88069X3811B103
57845/VDE0845
marking code SM diode
SM350XN
|
ES90XP
Abstract: No abstract text available
Text: Surge Arrester 2-Electrode-Arrester ES90XP Ordering code: T. B. D. Preliminary data DC spark-over voltage 1 2) 90 ± 20 V % < 450 < 300 V V < 600 < 550 V V Nominal impulse discharge current wave 8/20 µs) Single impulse discharge current (wave 8/20 µs)
|
Original
|
PDF
|
ES90XP
57845/VDE0845
ES90XP
|
B88069X4350C102
Abstract: B88069 EPCOS 800 A83-A150X
Text: Surge Arrester 2-Electrode-Arrester A83-A150X Ordering code: B88069X4350C102 DC spark-over voltage 1 2) 150 ± 20 V % < 600 < 450 V V < 800 < 600 V V Nominal impulse discharge current wave 8/20 µs) Single impulse discharge current (wave 8/20 µs) 20 20
|
Original
|
PDF
|
A83-A150X
B88069X4350C102
57845/VDE0845
B88069X4350C102
B88069
EPCOS 800
A83-A150X
|
PM 3000
Abstract: Arrester EM3000XB em epcos
Text: Surge Arrester 2-Electrode-Arrester EM3000XB Ordering code: B88069X6140B502 DC spark-over voltage 1 2) 3000 ± 20 V % < 4200 < 3800 V V < 5000 < 4200 V V 2 100 1 kA A A Insulation resistance at 100 Vdc >1 GΩ Capacitance at 1 MHz <1 pF Arc voltage at 1 A
|
Original
|
PDF
|
EM3000XB
B88069X6140B502
57845/VDE0845
B88069X60140B502
PM 3000
Arrester
EM3000XB
em epcos
|
Untitled
Abstract: No abstract text available
Text: Surge Arrester 2-Electrode-Arrester A83-A150X Ordering code: B88069X4350C102 DC spark-over voltage 1 2) 150 ± 20 V % < 600 < 450 V V < 800 < 600 V V Nominal impulse discharge current wave 8/20 µs) Single impulse discharge current (wave 8/20 µs) 20 20
|
Original
|
PDF
|
A83-A150X
B88069X4350C102
57845/VDE0845
|
EPCOS 350 09
Abstract: ES350XPA
Text: Surge Arrester 2-Electrode-Arrester ES350XPA Ordering code: B88069X4261B502 DC spark-over voltage 1 2) 300 … 400 V Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution < 550 < 500 V V < 650 < 600 V V Nominal impulse discharge current wave 8/20 µs)
|
Original
|
PDF
|
ES350XPA
B88069X4261B502
57845/VDE0845
EPCOS 350 09
ES350XPA
|
|
ES450XP
Abstract: No abstract text available
Text: Surge Arrester 2-Electrode-Arrester ES450XP Ordering code: T. B. D. Preliminary data DC spark-over voltage 1 2) 400 … 500 V Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution < 700 < 600 V V < 800 < 650
|
Original
|
PDF
|
ES450XP
57845/VDE0845
ES450XP
|
SURGE ARRESTER
Abstract: A83-C90X B88069X1450C102
Text: Surge Arrester 2-Electrode-Arrester A83-C90X Ordering code: B88069X1450C102 DC spark-over voltage 1 2) 90 ± 20 V % < 500 < 450 V V < 600 < 550 V V Nominal impulse discharge current wave 8/20 µs) Single impulse discharge current (wave 8/20 µs) 20 25 kA
|
Original
|
PDF
|
A83-C90X
B88069X1450C102
57845/VDE0845
SURGE ARRESTER
A83-C90X
B88069X1450C102
|
epcos 800 08 o
Abstract: No abstract text available
Text: Surge Arrester 2-Electrode-Arrester M51-A350XG Ordering code: B88069X5040T103 DC spark-over voltage 1 2) 350 ± 20 V % < 800 < 750 V V < 900 < 800 V V Nominal impulse discharge current wave 8/20 µs) Single impulse discharge current (wave 8/20 µs) 5 10
|
Original
|
PDF
|
M51-A350XG
B88069X5040T103
57845/VDE0845
epcos 800 08 o
|
EPCOS 230 05 O
Abstract: EPCOS 230 IEC 60068-1 Arrester diode a61 epcos 500 05 A61-A230XF
Text: Surge Arrester 2-Electrode-Arrester A61-A230XF Ordering code: B88069X2540C102 DC spark-over voltage 1 2) 230 ± 20 V % < 500 < 450 V V < 800 < 700 V V Nominal impulse discharge current wave 8/20 µs) Single impulse discharge current (wave 8/20 µs) 10 12
|
Original
|
PDF
|
A61-A230XF
B88069X2540C102
57845/VDE0845
EPCOS 230 05 O
EPCOS 230
IEC 60068-1
Arrester
diode a61
epcos 500 05
A61-A230XF
|
IEC 60068-1
Abstract: A81-A250XSMD B88069X1520T352
Text: Surge Arrester 2-Electrode-Arrester A81-A250XSMD Ordering code: B88069X1520T352 DC spark-over voltage 1 250 ± 20 V % < 550 < 500 V V < 700 < 650 V V Nominal impulse discharge current wave 8/20 µs) Single impulse discharge current (wave 8/20 µs) 20 25
|
Original
|
PDF
|
A81-A250XSMD
B88069X1520T352
57845/VDE0845
IEC 60068-1
A81-A250XSMD
B88069X1520T352
|
Untitled
Abstract: No abstract text available
Text: Surge Arrester 2-Electrode-Arrester A83-A170X Ordering code: B88069X4360C102 DC spark-over voltage 1 2) 170 ± 20 V % < 650 < 500 V V < 800 < 600 V V Nominal impulse discharge current wave 8/20 µs) Single impulse discharge current (wave 8/20 µs) 10 20
|
Original
|
PDF
|
A83-A170X
B88069X4360C102
57845/VDE0845
|
M51-A900XG
Abstract: M51-A90
Text: Surge Arrester 2-Electrode-Arrester DC spark-over voltage M51-A900XG Ordering code: B88069X6390T103 1 2) 900 ± 20 V % < 1700 < 1450 V V < 1850 < 1600 V V Nominal impulse discharge current wave 8/20 µs) Single impulse discharge current (wave 8/20 µs) Single impulse discharge current
|
Original
|
PDF
|
M51-A900XG
B88069X6390T103
57845/VDE0845
M51-A900XG
M51-A90
|
EM3500XP6
Abstract: No abstract text available
Text: Surge Arrester 2-Electrode-Arrester EM3500XP6 Ordering code: B88069X4221B502 DC spark-over voltage 1 2) 3500 ± 20 V % < 5000 < 4800 V V < 6000 < 5800 V V 2 100 1 kA A A Insulation resistance at 100 Vdc >1 GΩ Capacitance at 1 MHz <1 pF Arc voltage at 1 A
|
Original
|
PDF
|
EM3500XP6
B88069X4221B502
57845/VDE0845
EM3500XP6
|
em epcos 3000
Abstract: em3000xs PM 3000 surge arrester Ac S102 T502 b88069x4231xxxx
Text: Surge Arrester 2-Electrode-Arrester EM3000XS Ordering code: B88069X4231xxxx a DC spark-over voltage 1) 2) 3000 ± 20 V % < 3800 < 3400 V V < 4000 < 3500 V V 2 100 kA A Insulation resistance at 100 Vdc >1 GΩ Capacitance at 1 MHz <1 pF Arc voltage at 1 A
|
Original
|
PDF
|
EM3000XS
B88069X4231xxxx
57845/VDE0845
em epcos 3000
em3000xs
PM 3000
surge arrester Ac
S102
T502
|
b88069x41
Abstract: EF270X S102 T502
Text: Surge Arrester 2-Electrode-Arrester EF270X Ordering code: B88069X4131xxxx a DC spark-over voltage 1) 2) 230 … 338 V Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution < 500 < 450 V V < 550 < 500 V V Nominal impulse discharge current wave 8/20 µs)
|
Original
|
PDF
|
EF270X
B88069X4131xxxx
57845/VDE0845
b88069x41
EF270X
S102
T502
|