Untitled
Abstract: No abstract text available
Text: Signal processor MS96 for flow sensors MS96-11EX0-R/115VAC • ATEX category II 1 G, Ex Zone 0 ■ ATEX category II (1) D, Ex Zone 20 ■ single-channel signal processor MS96 ■ ■ adjustment via potentiometer ■ 6 LEDs for display of the flow state ■
|
Original
|
MS96-11EX0-R/115VAC
2013-07-13T13
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Temperature measuring amplifier 1-channel IM34-11Ex-Ci/K70 The temperature measuring amplifier IM34-11EX-CI/K70 is designed to evaluate the temperature-dependent variations of resistance thermo detectors RTD Ni100/Pt100, thermoelement types B, E, J, K, L, N, R, S
|
Original
|
IM34-11Ex-Ci/K70
IM34-11EX-CI/K70
Ni100/Pt100,
Ni100/Pt100
2013-07-13T20
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Valve control module 1-channel IME-DO-11EX/L The one-channel valve drivers of series IME-DO-11Ex/L feature an intrinsically safe output with limited current and voltage. Thus making direct connection to loads in the Exarea possible. The switching status of the output is indicated
|
Original
|
IME-DO-11EX/L
IME-DO-11Ex/L
2013-07-13T20
94/9/EC
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Ex-HART Isolating transducer 1-channel IM33-11EX-HI The 1-channel HART isolating transducer IIM33-11EX-HI is designed to operate intrinsically safe HART 2-wire transducers III in the Ex area and to transfer the measured signal to the non-Ex area. In addition to analog
|
Original
|
IM33-11EX-HI
IIM33-11EX-HI
2013-07-13T20
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC • ATEX category II 1 G, Ex Zone 0 ■ ATEX category II (1) D, Ex Zone 20 ■ single-channel signal processor MS96 ■ ■ adjustment via potentiometer ■ 6 LEDs for display of the flow state ■
|
Original
|
MS96-11EX0-R/230VAC
2013-07-13T13
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Valve control module 1-channel IM72-11EX/L The solenoid drivers of series IM72-11EX/L feature an intrinsically safe output with limited current and voltage. Thus making direct connection to loads in the Ex-area possible. Within the area of applicability of the European directive 94/9/EC ATEX it is permitted
|
Original
|
IM72-11EX/L
94/9/EC
2013-07-13T20
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Temperature measuring amplifier 1-channel IME-TI-11Ex-Ci/24VDC The temperature measuring amplifier IMETI-11Ex-Ci/24VDC is designed to evaluate the temperature-dependent variations of resistance thermo detectors RTD Ni100/Pt100, thermoelement types B, E, J, K, L, N, R, S
|
Original
|
IME-TI-11Ex-Ci/24VDC
IMETI-11Ex-Ci/24VDC
Ni100/Pt100,
Ni100/Pt100
D-45472
2013-07-13T20
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Analog signal isolator 1-channel IM31-11EX-U The single-channel analog data transmitter IM31-11Ex-U transmits standard active voltage or current signals. The device is equipped with one input circuit of 0/2…10 V or 0/4…20 mA and one short-circuit proof output circuit of 0/2…10 V.
|
Original
|
IM31-11EX-U
IM31-11Ex-U
2013-07-13T20
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Ex-Temperature measuring amplifier 1-channel IM34-11EX-CI The 1-channel Ex-temperature measuring amplifier IM34-11EX-CI is designed to evaluate the temperature-dependent variations of resistance thermo detectors RTD Ni100/Pt100, thermoelement types B, E, J, K, L, N, R, S
|
Original
|
IM34-11EX-CI
IM34-11EX-CI
Ni100/Pt100,
Ni100/Pt100
2013-07-13T20
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Analog signal isolator 1-channel IME-Ai-11Ex-Hi/L Active current signals are galvanically isolated and transmitted via the 1-port analog data transmitter IME-Ai-11EX-i/L from the Ex area to the safe area. The device features one input circuit 0/4…20 mA and one short-circuit proof output circuit
|
Original
|
IME-Ai-11Ex-Hi/L
IME-Ai-11EX-i/L
2013-07-13T20
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Edition • 2013-07-13T20:14:14+02:00 Temperature measuring amplifier 1-channel IM34-11EX-CI/K60 1/4 Hans Turck GmbH & Co.KG ñD-45472 Mülheim an der Ruhr ñWitzlebenstraße 7 ñTel. 0208 4952-0 ñFax 0208 4952-264 ñmore@turck.com ñwww.turck.com Temperature measuring amplifier
|
Original
|
2013-07-13T20
IM34-11EX-CI/K60
D-45472
IM34-11Ex-Ci/K60
Ni100/Pt100,
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Potentiometer amplifier 1-channel IM36-11EX-U/24VDC The 1-channel potentiometer amplifier IM36-11EX-U/24VDC separates signals from 3-wire or 5-wire potentiometers and transfers these as standard 0…10 V analog signals from the Ex area to the non-Ex area. The
|
Original
|
IM36-11EX-U/24VDC
IM36-11EX-U/24VDC
2013-07-13T20
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Analog signal isolator 1-channel IMC-AO-11EX-I/L The 1-channel analog signal isolator IMCAO-11Ex-i/L features an intrinsically safe input circuit. The device can be mounted in zone 2. Intrinsically analog actuators like I/P converters e.g. at control valves or displays can be
|
Original
|
IMC-AO-11EX-I/L
IMCAO-11Ex-i/L
2013-07-13T20
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Potentiometer amplifier 1-channel IM36-11EX-I/24VDC The 1-channel potentiometer amplifier IM36-11EX-I/24VDC separates signals from 3-wire or 5-wire potentiometers and transfers these as standard 0…20 mA analog signals from the Ex area to the non-Ex area. The resistance value of the wiper contact is collected
|
Original
|
IM36-11EX-I/24VDC
IM36-11EX-I/24VDC
2013-0ection
2013-07-13T20
D-45472
|
PDF
|
|
MS96-11EX0-R
Abstract: No abstract text available
Text: Signal processor MS96 for flow sensors MS96-11EX0-R/24VDC • ATEX category II 1 G, Ex Zone 0 ■ ATEX category II (1) D, Ex Zone 20 ■ single-channel signal processor MS96 ■ ■ adjustment via potentiometer ■ 6 LEDs for display of the flow state ■
|
Original
|
MS96-11EX0-R/24VDC
28VDC
2013-07-13T13
D-45472
MS96-11EX0-R
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Valve control module 1-channel IMC-DO-11EX/L Typical applications are the control of Ex i pilot valves and pilot lights as well as the supply of transmitters. The device must be protected against mechanical load on connector and housing when mounted in zone 2 or 22. For this,
|
Original
|
IMC-DO-11EX/L
2013-07-13T20
IMCDO-11Ex/L
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Analog signal isolator 1-channel IM31-11EX-I Active voltage or current signals are galvanically isolated and transmitted via the 1-channel analog data transmitter IM31-11EX-I from the Ex area to the safe area. The device is equipped with one input circuit
|
Original
|
IM31-11EX-I
IM31-11EX-I
2013-07-13T20
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Analog signal isolator 1-channel IM35-11EX-HI The standard current signal is galvanically separated and transferred via the 1-channel isolating transducer IM35-11EX-HI from the non-Ex area to the Ex-area without attenuation 1:1 . In addition to analog signals,
|
Original
|
IM35-11EX-HI
IM35-11EX-HI
D-45472
2013-07-13T20
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Ex-HART Isolating transducer 1-channel IM33-11EX-HI/24VDC The 1-channel HART isolating transducer IM33-11EX-HI/24VDC is designed to operate intrinsically safe HART 2-wire transducers III in the Ex area and to transfer the measured signal to the non-Ex area. In addition to
|
Original
|
IM33-11EX-HI/24VDC
IM33-11EX-HI/24VDC
2013-07-13T20
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Isolating transducer 1-channel IMC-AIA-11EX-I/24VDC The 1-channel isolating transducer IMCAIA-11Ex-i/24VDC features an intrinsically safe input circuit. The device can be mounted in zone 2. In case of unprotected mounting in zone 2 resp. zone 22 the devices must be protected
|
Original
|
IMC-AIA-11EX-I/24VDC
IMCAIA-11Ex-i/24VDC
2013-07-13T20
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Temperature measuring amplifier 1-channel IM34-11Ex-Ci/24VDC The temperature measuring amplifier M34-11Ex-Ci/24VDC is designed to evaluate the temperature-dependent variations of resistance thermo detectors RTD Ni100/Pt100, thermoelement types B, E, J, K, L, N, R, S
|
Original
|
IM34-11Ex-Ci/24VDC
M34-11Ex-Ci/24VDC
Ni100/Pt100,
Ni100/Pt100
2013-07-13T20
D-45472
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Analog signal isolator 1-channel IMC-AI-11EX-I/L The 1-channel analog signal isolator IMCAI-11EX-I/L features an intrinsically safe input circuit. The device can be mounted in zone 2. In case of unprotected mounting in zone 2 resp. zone 22 the devices must be protected
|
Original
|
IMC-AI-11EX-I/L
IMCAI-11EX-I/L
2013-07-13DA
2013-07-13T20
D-45472
|
PDF
|
MC68HC811E2FN2
Abstract: MC68HC811E2FN MC68HC811E2VFN2 MC68HC711E9CFS2 mc68hc811e2cp2 MC68HC811E2P MC68HC811E2CFN2 MC68HC711E9CFN3 MC68HC811E2MFN2 mc68hc811
Text: APPENDIX A ELECTRICAL CHARACTERISTICS Table A-1 Maximum Ratings Rating Symbol Value Unit V Supply Voltage VDD —0.3 to + 7.0 Input Voltage Vin -0.3 to + 7.0 V Operating Temperature Range MC68HC 7 11Ex MC68HC(7) 11 ExC MC68HC(7) 11 ExV MC68HC(7)11ExM MC68HC811E2
|
OCR Scan
|
MC68HC
11ExM
MC68HC811E2
MC68HC811E2C
MC68HC811E2V
MC68HC811E2M
MC68L11Ex
MC68HC811E2FN2
MC68HC811E2FN
MC68HC811E2VFN2
MC68HC711E9CFS2
mc68hc811e2cp2
MC68HC811E2P
MC68HC811E2CFN2
MC68HC711E9CFN3
MC68HC811E2MFN2
mc68hc811
|
PDF
|
D1274
Abstract: M68HC11 MC68HC MC68HC811E2 MC68HC811E2C MC68HC811E2M MC68L11E9 ci 7445
Text: APPENDIX A E LE C TR IC A L CH A R A CTER ISTICS Table A -1 . Maximum Ratings R a tin g Sym bol V a lu e U n it i Supply Voltage Vdd - 0.3 to «•7.0 V Input Voltage Vm - 0.3 to ♦ 7.0 V Operating Temperature Range MC68HC 7 11Ex MC68HC|7)11ExC MC68HC(7)11ExV
|
OCR Scan
|
MC68HC
MC68HC811E2
MC68HC811E2C
MC68HCS11E2V
MC68HC811E2M
MC68L11E9
-40to
D1274
M68HC11
ci 7445
|
PDF
|