MF-0637A-60BL
Abstract: No abstract text available
Text: MF-0637A-60BL LINE Operating Voltage = 48 Vdc Operating Current = 60 Amperes Operating Temperature Range = -40 to 50 C Dielectric Withstanding Voltage Line to Line: 707 Vdc for 1 minute Line to Case: 2250 Vdc for 1.0 min Safety Agency Approval = TUV CSA Canada Y US
|
Original
|
MF-0637A-60BL
MM-0637A
-60BL
Caldwell100
MF-0637A-60BL
|
PDF
|
Untitled
Abstract: No abstract text available
Text: MM-0637A-50C This filter features a very small mechanical package with a very good common mode insertion loss and differential loss. LINE LOAD This filter has been designed to operate with severe unbalanced current loading and can withstand up to a 30% unbalance in line and return without degrading the
|
Original
|
MM-0637A-50C
|
PDF
|
Untitled
Abstract: No abstract text available
Text: MM-0637A-40D Operating Voltage = 48 Vdc Typical Operating Voltage Max. = 0—75Vdc Operating Current = 40 Amp Operating Temp Range = -40 to 50 C (see chart) Storage temperature = -55—100 C Dielectric Withstanding Voltage Line to Line: 707 Vdc for 1 minute
|
Original
|
MM-0637A-40D
0--75Vdc
|
PDF
|
Untitled
Abstract: No abstract text available
Text: MM-0637A-50C Operating Voltage = 48 Vdc Operating Current = 50 Amperes Operating Temperature Range = -40 to 50 C Dielectric Withstanding Voltage Line to Line: 707 Vdc for 1 minute Line to Case: 2250 Vdc for 1.0 min Order P/N: LOAD LINE MM-0637A-50C Safety Agency Approvals
|
Original
|
MM-0637A-50C
|
PDF
|
Untitled
Abstract: No abstract text available
Text: MM-0637A-60D Operating Voltage = 48 Vdc Typical Operating Voltage Max. = 0—75Vdc Operating Current = 60 Amp Operating Temp Range = -40 to 50 C (see chart) Storage temperature = -55—100 C Dielectric Withstanding Voltage Line to Line: 707 Vdc for 1 minute
|
Original
|
MM-0637A-60D
0--75Vdc
|
PDF
|
MM-0637A-40C
Abstract: MM-0637A-60C
Text: MM-0637A-40C, -50C, -60C Operating Voltage = 48 Vdc Operating Current = 40,50,60 Amperes Operating Temperature Range = -40 to 50 C Dielectric Withstanding Voltage Line to Line: 707 Vdc for 1 minute Line to Case: 2250 Vdc for 1.0 min 40 Amps Order P/N: MM-0637A-40C
|
Original
|
MM-0637A-40C,
MM-0637A-40C
MM-0637A-50C
MM-0637A-60C
MM-0637A
MM-0637A-40C
MM-0637A-60C
|
PDF
|
MF-0637A-60BR
Abstract: No abstract text available
Text: MF-0637A-60BR This EMI / RFI filter features a very small mechanical package. Even with this small size the common mode insertion loss and differential loss are more than is available in other similarly sized packages. LINE LOAD This filter has additionally been designed to operate with
|
Original
|
MF-0637A-60BR
MF-0637A-60BR
|
PDF
|
MF-0637A-50BL
Abstract: No abstract text available
Text: MF-0637A-50BL This EMI / RFI filter features a very small mechanical pack age. T he comm on m ode insertion loss and differential loss is more than is available in other similarly sized packages. This filter has additionally been designed to operate with severely unbalanced current loading. It can withstand up
|
Original
|
MF-0637A-50BL
MM-0637A-50BL
MF-0637A-50BL
|
PDF
|
Untitled
Abstract: No abstract text available
Text: MM-0637A-40D, 50D, 60D This filter features a very small mechanical package with excellent common mode and differential insertion loss. LINE LOAD This filter has been designed to operate with severely unbalanced current loading and can withstand up to a 30% unbalance in line and return without degrading the
|
Original
|
MM-0637A-40D,
MM-0637A-40D
MM-0637A-50D
MM-0637A-60D
MM-0637A
|
PDF
|
MM-0637A-100
Abstract: JMK Filters
Text: MM-0637A-100 Operating Voltage = 48 Vdc Operating Current Max = 100 Amp Temperature Range(Storage) = -55 TO 85 C Temperature Range(Operating) = -20 TO 50 C Diel. Withstand Voltage (Term - Case) = 1500 Vdc Diel. Withstand Voltage ( + to - ) = 707 Vdc This filter is the 100 amp version of our 637A
|
Original
|
MM-0637A-100
MM-0637A-100
JMK Filters
|
PDF
|
Untitled
Abstract: No abstract text available
Text: MF-0637A-50BL Operating Voltage = 48 Vdc Operating Current = 50 Amperes Operating Temperature Range = -40 to 50 C Dielectric Withstanding Voltage Line to Line: 707 Vdc for 1 minute Line to Case: 2250 Vdc for 1.0 min LINE LOAD Safety Agency Approval = TUV,
|
Original
|
MF-0637A-50BL
MM-0637A
-50BL
MF-0637A-50BL
|
PDF
|
Untitled
Abstract: No abstract text available
Text: MM-0637A-50B LOAD LINE Operating Voltage = 48 Vdc Operating Current = 50 Amperes Operating Temperature Range = -40 to 50 C Dielectric Withstanding Voltage Line to Line: 707 Vdc for 1 minute Line to Case: 2250 Vdc for 1.0 min Order P/N: MM-0637A-50B Safety Agency Approvals
|
Original
|
MM-0637A-50B
|
PDF
|
Untitled
Abstract: No abstract text available
Text: MM-0637A-40B, -50B, -60B Operating Voltage = 48 Vdc Operating Current = 40,50,60 Amperes Operating Temperature Range = -40 to 50 C Dielectric Withstanding Voltage Line to Line: 707 Vdc for 1 minute Line to Case: 2250 Vdc for 1.0 min 40 Amps Order P/N: MM-0637A-40B
|
Original
|
MM-0637A-40B,
MM-0637A-40B
MM-0637A-50B
MM-0637A-60B
MM-0637A
|
PDF
|
MF-0637A-50BR
Abstract: No abstract text available
Text: MF-0637A-50BR This EMI / RFI filter features a very small mechanical package. Even with this small size the common mode insertion loss and differential loss are more than is available in other similarly sized packages. LINE LOAD This filter has additionally been designed to operate with
|
Original
|
MF-0637A-50BR
MM-0637A-50BR
MF-0637A-50BL
MF-0637A-50BR
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: MF-0637A-50BR This EMI / RFI filter features a very small mechanical package. Even with this small size the common mode insertion loss and differential loss are more than is available in other similarly sized packages. This filter has additionally been designed to operate with
|
Original
|
MF-0637A-50BR
|
PDF
|
0-75VDC
Abstract: No abstract text available
Text: MM-0637A-50D Operating Voltage = 48 Vdc Typical Operating Voltage Max. = 0—75Vdc Operating Current = 50 Amp Operating Temp Range = -40 to 50 C (see chart) Storage temperature = -55—100 C Dielectric Withstanding Voltage Line to Line: 707 Vdc for 1 minute
|
Original
|
MM-0637A-50D
0--75Vdc
0-75VDC
|
PDF
|
Untitled
Abstract: No abstract text available
Text: MF-0637A-60BR LINE Operating Voltage = 48 Vdc Operating Current = 60 Amperes Operating Temperature Range = -40 to 50 C Dielectric Withstanding Voltage Line to Line: 707 Vdc for 1 minute Line to Case: 2250 Vdc for 1.0 min Safety Agency Approval = TUV CSA Canada Y US
|
Original
|
MF-0637A-60BR
MM-0637A-60BR
MM-0637A
|
PDF
|
Untitled
Abstract: No abstract text available
Text: MM-0637A-40B, -50B, -60B This EMI / RFI filter features a very small mechanical package with a very good common mode insertion loss and differential loss. LINE LOAD This filter has been designed to operate with severe unbalanced current loading and can withstand up to a
|
Original
|
MM-0637A-40B,
MM-0637A-40B
MM-0637A-50B
MM-0637A-60B
MM-0637A
|
PDF
|
tsop tray matrix outline
Abstract: tsop Shipping Trays JEDEC Matrix Tray outlines Atmel 918 EIA-481-x ATMEL Packing Methods and Quantities JEDEC Matrix Tray outlines soic ATMEL Tape and Reel PLCC JEDEC tray Shipping Trays
Text: Packages Available Packing Methods and Quantities Atmel provides four different packing methods to provide maximum protection for our product and to best suit our customer’s needs: 1 Shipping Tubes, 2) Shipping Trays, 3) Unit Packing, and 4) Tape and Reel. These first three methods are our standard pack, but we also
|
Original
|
|
PDF
|