Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    "Z CURVE" MCB Search Results

    "Z CURVE" MCB Result Highlights (1)

    Part ECAD Model Manufacturer Description Download Buy
    RTK0EMA270C00000BJ Renesas Electronics Corporation MCB-RA6T2 CPU Board for RA6T2 MCU Group Visit Renesas Electronics Corporation

    "Z CURVE" MCB Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    SINGLE POLE MCB

    Abstract: 110v double POLE MCB MZ203 MZ206 NCN100A NCN206A NBN463A NDN104A NCN106A NCN116A
    Text: Miniature Circuit Breakers Curve B,C & D : EN 60898 : 10000 and EN 60947-2 : 15kA NBNxxxA : “B” Curve NCNxxxA : “C” Curve NDNxxxA : “D” Curve In 0.5 to 63A Un : 230V-400V Will accept accessories See page XX Description These MCBs allow you to ensure


    Original
    PDF 30V-400V 415Vac 130Vdc 48Vac 48Vdc MZ203 MZ204 230Vac MZ206 SINGLE POLE MCB 110v double POLE MCB MZ203 MZ206 NCN100A NCN206A NBN463A NDN104A NCN106A NCN116A

    mcb tripping curves

    Abstract: S2H11 S2-H11 ABB SHUNT TRIP IEC60947-2 IEC60898 mcb B CURVE TRIPPING VOLTAGE S2-H02 ABB MCB s260 ABB MCB
    Text: Line Protection Devices MCB- S270 & S260 series Conforms to IEC60898, IS8828-10kA and IEC60947-2 ABB- the pioneer in MCB technology brings to you the S270 range based on system pro M, a modular system developed by ABB. The S270 range of MCBs are designed and constructed to


    Original
    PDF IEC60898, IS8828-10kA IEC60947-2 IS8828 IEC60898 IEC60947/2 90x17 12-64AC 12-110DC 125-415AC mcb tripping curves S2H11 S2-H11 ABB SHUNT TRIP IEC60947-2 mcb B CURVE TRIPPING VOLTAGE S2-H02 ABB MCB s260 ABB MCB

    Untitled

    Abstract: No abstract text available
    Text: VNPC www.vishay.com Vishay MCB Vitreous Wirewound Power Resistor, Flat FEATURES • High dissipation • Reduced space • Embedded collars • Insulated mounting • Material categorization: for definitions of compliance please see www.vishay.com/doc?99912


    Original
    PDF MIL-R-26-D 2002/95/EC. 2002/95/EC 2011/65/EU. JS709A 02-Oct-12

    mcb with z curve

    Abstract: F202A F204A F202AC F204AC type 2 mcb mcb with K curve en 60947-2 "en 61008" mcb rating 10
    Text: 1271-2012.qxp:QuarkCatalogTempNew 8/31/12 9:17 AM Page 1271 14 Miniature Circuit Breakers and Ground Fault Equipment Protector Continued RoHS All MCBs of the product range S200U are current limiting with two tripping mechanisms (delayed thermal and electromechanic). They are available in different characteristics (K, Z), configurations (1P, 2P, 3P, 4P), breaking capacities


    Original
    PDF S200U S200U MfS200UP F202AC-25/0 F202AC-40/0 F202AC-63/0 F202AC-80/0 F202AC-100/0 F204AC-25/0 mcb with z curve F202A F204A F202AC F204AC type 2 mcb mcb with K curve en 60947-2 "en 61008" mcb rating 10

    faulhaber wire

    Abstract: K1855 MCBL3003 din 58400 W1 3003
    Text: Brushless DC-Servomotors 2,2 mNm For combination with Gearheads: 10/1, 12/3, 12/4, 12/5 Drive electronics: SC 1801, BLD 4803, MCBL . Series 1226 . B 1 2 3 4 Nominal voltage Terminal resistance, phase-phase Output power 1 Efficiency 1226 S UN R P2 max.


    Original
    PDF

    UL1077

    Abstract: No abstract text available
    Text: Altech UL1077 11/14/13 10:50 AM Page 10 Typical UL1077 Application Control Circuit of a UL508A Panel Disclaimer: This is an example application. Installation should be done by a qualified electrician under the guidance of UL/NEC specifications.


    Original
    PDF UL1077 UL1077 UL508A E301611 480Y/277V 50/60Hz With14 TR-11

    rc 3866

    Abstract: abl sursum mcb type b 160A mccb curve 2CU8 2DNU6 3C63 zytel fr 72 3E63 ABL SURSUM 24V 0.5A ROYAL FUSE
    Text: MINIATURE CIRCUIT BREAKERS MCBs UL Recognized Supplementar y Pr otectors vs. UL Listed Manual Motor Contr ollers D4A D 16A I 277V AC 277V AC 10000 1D4.0 1DU16 I 10kA LISTED 4C87 UL Recognized UL Listed UL Recognized one pole supplementary protector UL Listed one pole manual motor controller


    Original
    PDF 1DU16 3P18U3H/6 3P18U3H/9 3P18U3H/12 3P18U3H/18 3P25U3H/6 3P25U3H/9 3P25U3H/12 3P25U3H/18 3P18U3H/24 rc 3866 abl sursum mcb type b 160A mccb curve 2CU8 2DNU6 3C63 zytel fr 72 3E63 ABL SURSUM 24V 0.5A ROYAL FUSE

    S282-UC

    Abstract: S261-b16 IEC-898 S281-UC S261-C2 S262-C10 S272-K10 S261-C16 S261-C10 S261-B6
    Text: Pro M Miniature circuit breakers General information General information CSA C22.2 Miniature circuit breakers MCBs are used throughout the world in all types of electrical installations. ABB MCBs are recognized for use by Underwriters Laboratories Standard


    Original
    PDF UL1077 240VAC, 480VAC 600VAC. IEC-898 IEC-947 415VAC 690VAC 400Hz E240/270 S282-UC S261-b16 S281-UC S261-C2 S262-C10 S272-K10 S261-C16 S261-C10 S261-B6

    ABB RD2 earth leakage relay

    Abstract: DS651 RD2 earth leakage relay E251-230 E76126 S272C10 S272C6 ABB DC Main Circuit breaker 2POLE ABB MCCB SHUNT TRIP S273-K32
    Text: Line Protection Contents Miniature Circuit Breakers MCB’s . 3-2 Protecta Type B Pan Assemblies . 3-12 High Performance MCB’s.


    Original
    PDF ESB20 ESB24 ESB40 ESB63 ABB RD2 earth leakage relay DS651 RD2 earth leakage relay E251-230 E76126 S272C10 S272C6 ABB DC Main Circuit breaker 2POLE ABB MCCB SHUNT TRIP S273-K32

    EPC60

    Abstract: gps1bh FK1250H GE MCB B16 IEC 60898 category C mcb tripping curves 64c04 mcb C16 630 mcb c CURVE TRIPPING VOLTAGE 20 A FG400N
    Text: GE Consumer & Industrial Power Protection New ElfaPlus Unibis Compact MCB’s Saving up to 50% space in distribution boards GE imagination at work ElfaPlus Unibis™ 2 Advantages 6 Miniature circuit breakers - Series EPC 31N 7 Miniature circuit breakers - Series EPC 451N


    Original
    PDF R/2362/E/E EPC60 gps1bh FK1250H GE MCB B16 IEC 60898 category C mcb tripping curves 64c04 mcb C16 630 mcb c CURVE TRIPPING VOLTAGE 20 A FG400N

    Ka 2535

    Abstract: time current curve type c mcb mcb B CURVE TRIPPING VOLTAGE mcb c CURVE TRIPPING VOLTAGE 20 A mcb with z curve S202-C10 S201B10 mcb with K curve S201C10 S202-B6
    Text: 1270-2012.qxp:QuarkCatalogTempNew 8/31/12 9:15 AM Page 1270 Miniature Circuit Breakers S200 Miniature Circuit Breakers for Branch Protection RoHS System pro M compact S200 miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for


    Original
    PDF 0Y/277 S202-B6 S202-C10 S202-K1 S202-K2 S202-K3 S202-K4 S202-K5 S202-K6 S202P-K8* Ka 2535 time current curve type c mcb mcb B CURVE TRIPPING VOLTAGE mcb c CURVE TRIPPING VOLTAGE 20 A mcb with z curve S201B10 mcb with K curve S201C10

    calculation of transformer differential relay setting for RET615

    Abstract: ref 615 abb interposing CT transistor A968 PCM600 IDMT characteristic of REM - 615 ABB 1MAC050144-MB vn-240 pc znyn11 IDMT relay
    Text: Relion Protection and Control 615 series ANSI Technical Manual Document ID: 1MAC050144-MB Issued: 01/20/2010 Revision: A Product version: 2.0 Copyright 2010 ABB. All rights reserved Copyright This document and parts thereof must not be reproduced or copied without written


    Original
    PDF 1MAC050144-MB PCM600 1MAC050144-MB calculation of transformer differential relay setting for RET615 ref 615 abb interposing CT transistor A968 PCM600 IDMT characteristic of REM - 615 ABB vn-240 pc znyn11 IDMT relay

    mccb 60947-2 max zs

    Abstract: 60947-2 MAX EARTH LOOP IMPEDANCE wiring diagram of rccb hager mcb 3 phase MCB installation drawing hager HD149U rcbo circuit diagram HMF280T ADA925U
    Text: Auxiliaries and accessories 3.5 RCCB add-on blocks 3.6 Miniature cicruit breakers 80-125A 3.8 Single pole & switch neutral devices 3.15 2 & 4 pole RCCBs 3.16 RCCB auxiliaries 3.17 RCBO single pole 3.18 RCBO single pole and switched neutral 3.19 HRC fuse carriers and


    Original
    PDF 0-125A 630ples mccb 60947-2 max zs 60947-2 MAX EARTH LOOP IMPEDANCE wiring diagram of rccb hager mcb 3 phase MCB installation drawing hager HD149U rcbo circuit diagram HMF280T ADA925U

    mccb 60947-2 max zs

    Abstract: 60947-2 MAX EARTH LOOP IMPEDANCE hager 3 phase MCB installation drawing hager mcb HD149U MCCB wiring diagram HD148U IEC 60947-2 max zs HN204
    Text: Auxiliaries and accessories 3.5 RCCB add-on blocks 3.6 Miniature cicruit breakers 80-125A 3.8 Single pole & switch neutral devices 3.15 2 & 4 pole RCCBs 3.16 RCCB auxiliaries 3.17 RCBO single pole 3.18 RCBO single pole and switched neutral 3.19 HRC fuse carriers and


    Original
    PDF 0-125A 630ples mccb 60947-2 max zs 60947-2 MAX EARTH LOOP IMPEDANCE hager 3 phase MCB installation drawing hager mcb HD149U MCCB wiring diagram HD148U IEC 60947-2 max zs HN204

    24V lead acid battery charger circuit

    Abstract: No abstract text available
    Text: DIN Rail Power Supplies Since 1984, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff of engineering, manufacturing and sales personnel to provide the highest quality


    Original
    PDF 5150A 24V lead acid battery charger circuit

    calculation of transformer differential relay setting for RET615

    Abstract: RM1- 4616 motor 1MRS756887 ABB make REC 670 REU615 PCM600 abb ref615 ltc 3588 siemens s5 plc RED615
    Text: Relion Protection and Control 615 series Technical Manual Document ID: 1MRS756887 Issued: 2010-09-24 Revision: E Product version: 3.0 Copyright 2010 ABB. All rights reserved Copyright This document and parts thereof must not be reproduced or copied without written


    Original
    PDF 1MRS756887 FI-65101 1MRS756887 calculation of transformer differential relay setting for RET615 RM1- 4616 motor ABB make REC 670 REU615 PCM600 abb ref615 ltc 3588 siemens s5 plc RED615

    IC60H

    Abstract: CA907021 IC60N C CURVE A9F44220 IC60N 1P N SEA9BN24TN A9C32811 merlin gerin RCBO A9C64216 telemecanique contactor catalogue
    Text: Low voltage Acti 9 the efficiency you deserve Catalogue 2013 Acti 9 The safest, simplest and most efficient system for power distribution solutions Protection devices > Miniature circuit breaker > Residual current circuit breaker > Vigi residual current devices


    Original
    PDF SE7856 IC60H CA907021 IC60N C CURVE A9F44220 IC60N 1P N SEA9BN24TN A9C32811 merlin gerin RCBO A9C64216 telemecanique contactor catalogue

    REF630

    Abstract: calculation of transformer differential relay RET 670 star delta FORWARD REVERSE STARTER 1MRS756508 ABB HCA BREAKER OF INN 9182 wind turbine mini project abb 630 PROJECT REPORT ON 220 kv substation inn 9182
    Text: Relion Protection and Control 630 series Technical Manual Document ID: 1MRS756508 Issued: 15.09.2009 Revision: A Product version: 1.0 Copyright 2009 ABB. All rights reserved Copyright This document and parts thereof must not be reproduced or copied without written


    Original
    PDF 1MRS756508 RS485 FI-65101 1MRS756508 REF630 calculation of transformer differential relay RET 670 star delta FORWARD REVERSE STARTER ABB HCA BREAKER OF INN 9182 wind turbine mini project abb 630 PROJECT REPORT ON 220 kv substation inn 9182

    sb339

    Abstract: BAU10
    Text: Datasheet BR & SU Series UL489/CSA C22.2 No.5-02 Branch rated Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors NEW Compared to traditional fuse installation, the UL489/CSA C22.2 No.5-02, UL1077/CSA C22.2 No.235 compliant circuit breakers


    Original
    PDF UL489/CSA UL1077/CSA 4x10-2 LIT1221 sb339 BAU10

    Untitled

    Abstract: No abstract text available
    Text: D E V E LO P M E N T D ATA TEA1064A T h is d a ta sheet co n ta in s advance in fo r m a tio n and s p e c ific a tio n s are su b je c t to change w it h o u t n o tic e . - A _ LOW VOLTAGE VERSATILE TELEPHONE TRANSMISSION CIRCUIT WITH DIALLER INTERFACE AND


    OCR Scan
    PDF TEA1064A TEA1064A PCD332X A1064A F8577 PCD3344

    TDA3410

    Abstract: stereo Preamplifier
    Text: SGS-mOMSON TDA3410 DUAL LOW NOISE TAPE PREAMPLIFIER WITH AUTOREVERSE • ■ ■ ■ ■ ■ ■ ■ ■ VERY LOW NOISE HIGH GAIN LOW DISTORTION SINGLE SUPPLY OPERATION WIDE SUPPLY RANGE SVR = 120 dB LARGE OUTPUT VOLTAGE SWING TAPE AUTOREVERSE FACILITY SHORT-CIRCUIT PROTECTION


    OCR Scan
    PDF TDA3410 TDA3410 16-lead stereo Preamplifier

    tea 1061 ic pin configuration

    Abstract: DTMF13 5.1 amplifier circuits diagram
    Text: TEA1064A _ LOW VOLTAGE VERSATILE TELEPHONE TRANSMISSION CIRCUIT WITH DIALLER INTERFACE AND TRANSMIT LEVEL DYNAMIC LIMITING G EN ER A L DESCRIPTION The TEA 106 4A is a bipolar integrated circuit that performs all the speech and line interface functions


    OCR Scan
    PDF TEA1064A TEA1064A PCD3310; PCD332X PCD3344 tea 1061 ic pin configuration DTMF13 5.1 amplifier circuits diagram

    Untitled

    Abstract: No abstract text available
    Text: Philips Semiconductors Product specification Low voltage versatile telephone transmission circuit with dialler interface and transmit level dynamic limiting TEA1064A GENERAL DESCRIPTION The TEA1064A is a bipolar integrated circuit that performs all the speech and line interface functions


    OCR Scan
    PDF TEA1064A TEA1064A PCD3310; PCD332X 7Z26S11 PCD3344

    piezo electric microphone

    Abstract: Automatic Voltage stabilizer tea 1061 ic pin configuration tea 1633 PCD332x audio automatic gain control circuit diagram for automatic voltage regulator Piezo electric Microphones RVA-33 TEA1064A
    Text: D E V E L O P M E N T D A TA TEA1064A T h is data sheer co n ta in s advance in fo r m a tio n and s p e c ific a tio n s are su b je ct to change w it h o u t n o tic e . LO W VO LTAG E VERSATILE TELEPHONE TR A N SM ISSIO N CIRCUIT W ITH DIALLER INTERFACE AND


    OCR Scan
    PDF TEA1064A TEA1064A A1064A piezo electric microphone Automatic Voltage stabilizer tea 1061 ic pin configuration tea 1633 PCD332x audio automatic gain control circuit diagram for automatic voltage regulator Piezo electric Microphones RVA-33